2.
Heart Rhythm ; 18(1): 50-56, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32853778

RESUMO

BACKGROUND: Alcohol septal ablation (ASA) in patients with hypertrophic cardiomyopathy (HCM) can lead to heart rhythm disturbances including complete heart block (CHB) and atrial and ventricular arrhythmias. OBJECTIVE: We aimed to evaluate the utility of long-term arrhythmia monitoring with an implantable cardiac monitor (ICM) after ASA. METHODS: Between February 2014 and March 2019, 56 patients with HCM undergoing ASA were enrolled in a prospective study and underwent ICM implantation. Kaplan-Meier survival analysis was used to assess the rate of ICM-detected arrhythmic events. RESULTS: The mean age was 59 ± 11 years, and 20 (36%) were women. The median (25th, 75th percentile) resting left ventricular outflow tract gradient obtained by echocardiography was 43 (22, 81) mm Hg. Greater than 1 septal perforating artery was injected in 48 patients (86%). The Kaplan-Meier cumulative rate of ICM-detected arrhythmic events at 18 months of follow-up was 71%, with an event rate of 43% occurring within 3 months of ASA. The cumulative rate of the ICM-detected first atrial fibrillation event at 18 months was 37%, and the corresponding rate of CHB was 19%. All atrial fibrillation and CHB events were actionable, leading to the initiation of anticoagulation and pacemaker implantation, respectively. No baseline demographic or procedural variables were identified as independent predictors of an increased risk of developing ICM-detected arrhythmic events. CONCLUSION: After ASA, ICM is effective in capturing clinically actionable arrhythmic events in patients with HCM regardless of patient's baseline risk factors.


Assuntos
Técnicas de Ablação/efeitos adversos , Arritmias Cardíacas/etiologia , Cardiomiopatia Hipertrófica/terapia , Eletrodos Implantados , Etanol/efeitos adversos , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Feminino , Seguimentos , Septos Cardíacos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
3.
ASAIO J ; 62(6): 639-645, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27442857

RESUMO

There is a large population of patients with end-stage congestive heart failure who cannot be treated by means of conventional cardiac surgery, cardiac transplantation, or chronic catecholamine infusions. Implantable cardiac devices, many designated as destination therapy, have revolutionized patient care and outcomes, although infection and complications related to external power sources or routine battery exchange remain a substantial risk. Complications from repeat battery replacement, power failure, and infections ultimately endanger the original objectives of implantable biomedical device therapy - eliminating the intended patient autonomy, affecting patient quality of life and survival. We sought to review the limitations of current cardiac biomedical device energy sources and discuss the current state and trends of future potential energy sources in pursuit of a lifelong fully implantable biomedical device.


Assuntos
Fontes de Energia Elétrica , Coração Auxiliar , Fenômenos Eletromagnéticos , Insuficiência Cardíaca/terapia , Coração Auxiliar/tendências , Humanos , Qualidade de Vida