Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 356
Filtrar
1.
Transl Psychiatry ; 11(1): 169, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33723233

RESUMO

Lack of established knowledge and treatment strategies, and change in work environment, may altogether critically affect the mental health and functioning of physicians treating COVID-19 patients. Thus, we examined whether treating COVID-19 patients affect the physicians' mental health differently compared with physicians treating non-COVID-19 patients. In this cohort study, an association was blindly computed between physiologically measured anxiety and attention vigilance (collected from 1 May 2014 to 31 May 31 2016) and self-reports of anxiety, mental health aspects, and sleep quality (collected from 20 April to 30 June 2020, and analyzed from 1 July to 1 September 2020), of 91 physicians treating COVID-19 or non-COVID-19 patients. As a priori hypothesized, physicians treating COVID-19 patients showed a relative elevation in both physiological measures of anxiety (95% CI: 2317.69-2453.44 versus 1982.32-2068.46; P < 0.001) and attention vigilance (95% CI: 29.85-34.97 versus 22.84-26.61; P < 0.001), compared with their colleagues treating non-COVID-19 patients. At least 3 months into the pandemic, physicians treating COVID-19 patients reported high anxiety and low quality of sleep. Machine learning showed clustering to the COVID-19 and non-COVID-19 subgroups with a high correlation mainly between physiological and self-reported anxiety, and between physiologically measured anxiety and sleep duration. To conclude, the pattern of attention vigilance, heightened anxiety, and reduced sleep quality findings point the need for mental intervention aimed at those physicians susceptible to develop post-traumatic stress symptoms, owing to the consequences of fighting at the forefront of the COVID-19 pandemic.


Assuntos
Ansiedade/psicologia , Atenção , COVID-19/terapia , Estresse Ocupacional/psicologia , Médicos/psicologia , Reflexo de Sobressalto , Sono , Transtornos de Estresse Pós-Traumáticos/psicologia , Adulto , Análise por Conglomerados , Feminino , Humanos , Aprendizado de Máquina , Masculino , Saúde Mental , Pessoa de Meia-Idade , SARS-CoV-2
2.
Knee ; 27(5): 1593-1600, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33010778

RESUMO

BACKGROUND: Revision knee replacement (KR) is technically challenging, expensive, and outcomes can be poor. It is well established that increasing surgeon and unit volumes results in improved outcomes and cost-effectiveness for complex procedures. The aim of this study was to 1) describe the current provision of revision KR in England, Wales and Northern Ireland at the individual surgeon and unit level and 2) investigate the effect on workload of case distribution in a network model. METHODS: Current practice was mapped using NJR summary statistics containing all revision KR procedures performed over a three-year period (2016-2018). Units were identified as revision centres based on threshold volumes. Units undertaking <20 revisions per year were classified as Primary Arthroplasty Units (PAUs) in calculations on the effect of workload centralisation. RESULTS: Revision KR was performed by 1353 surgeons at 232 NHS sites. The majority of surgeons and units were low-volume; >1000 surgeons performed <7 and 125 sites performed <20 procedures per year. Reallocation of work from these 125 PAUs (1235 cases, 21% of total workload) to a network model with even redistribution of cases between centres undertaking revision surgery would result in an additional average annual case increase of 11 per unit per year (range six to 14). CONCLUSIONS: Revision KR workload re-allocation would lift all revision centres above a 30 per year threshold and would appear to be a manageable increase in workload for specialist revision KR centres. Case complexity and local referral agreements will significantly affect the real increase in workload; these factors were not incorporated here.


Assuntos
Artroplastia do Joelho/métodos , Sistema de Registros , Cirurgiões/estatística & dados numéricos , Carga de Trabalho/estatística & dados numéricos , Inglaterra , Humanos , Irlanda do Norte , Reoperação/estatística & dados numéricos , País de Gales
3.
Knee ; 27(5): 1690-1692, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32883561
4.
J Med Imaging (Bellingham) ; 6(2): 024502, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31259199

RESUMO

Recent advances in the field of radiomics have enabled the development of a number of prognostic and predictive imaging-based tools for a variety of diseases. However, wider clinical adoption of these tools is contingent on their generalizability across multiple sites and scanners. This may be particularly relevant in the context of radiomic features derived from T1- or T2-weighted magnetic resonance images (MRIs), where signal intensity values are known to lack tissue-specific meaning and vary based on differing acquisition protocols between institutions. We present the first empirical study of benchmarking five different radiomic feature families in terms of both reproducibility and discriminability in a multisite setting, specifically, for identifying prostate tumors in the peripheral zone on MRI. Our cohort comprised 147 patient T2-weighted MRI datasets from four different sites, all of which are first preprocessed to correct for acquisition-related artifacts such as bias field, differing voxel resolutions, and intensity drift (nonstandardness). About 406 three-dimensional voxel-wise radiomic features from five different families (gray, Haralick, gradient, Laws, and Gabor) were evaluated in a cross-site setting to determine (a) how reproducible they are within a relatively homogeneous nontumor tissue region and (b) how well they could discriminate tumor regions from nontumor regions. Our results demonstrate that a majority of the popular Haralick features are reproducible in over 99% of all cross-site comparisons, as well as achieve excellent cross-site discriminability (classification accuracy of ≈ 0.8 ). By contrast, a majority of Laws features are highly variable across sites (reproducible in < 75 % of all cross-site comparisons) as well as resulting in low cross-site classifier accuracies ( < 0.6 ), likely due to a large number of noisy filter responses that can be extracted. These trends suggest that only a subset of radiomic features and associated parameters may be both reproducible and discriminable enough for use within machine learning classifier schemes.

5.
JAMA Netw Open ; 2(4): e192561, 2019 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-31002322

RESUMO

Importance: There has been significant recent interest in understanding the utility of quantitative imaging to delineate breast cancer intrinsic biological factors and therapeutic response. No clinically accepted biomarkers are as yet available for estimation of response to human epidermal growth factor receptor 2 (currently known as ERBB2, but referred to as HER2 in this study)-targeted therapy in breast cancer. Objective: To determine whether imaging signatures on clinical breast magnetic resonance imaging (MRI) could noninvasively characterize HER2-positive tumor biological factors and estimate response to HER2-targeted neoadjuvant therapy. Design, Setting, and Participants: In a retrospective diagnostic study encompassing 209 patients with breast cancer, textural imaging features extracted within the tumor and annular peritumoral tissue regions on MRI were examined as a means to identify increasingly granular breast cancer subgroups relevant to therapeutic approach and response. First, among a cohort of 117 patients who received an MRI prior to neoadjuvant chemotherapy (NAC) at a single institution from April 27, 2012, through September 4, 2015, imaging features that distinguished HER2+ tumors from other receptor subtypes were identified. Next, among a cohort of 42 patients with HER2+ breast cancers with available MRI and RNaseq data accumulated from a multicenter, preoperative clinical trial (BrUOG 211B), a signature of the response-associated HER2-enriched (HER2-E) molecular subtype within HER2+ tumors (n = 42) was identified. The association of this signature with pathologic complete response was explored in 2 patient cohorts from different institutions, where all patients received HER2-targeted NAC (n = 28, n = 50). Finally, the association between significant peritumoral features and lymphocyte distribution was explored in patients within the BrUOG 211B trial who had corresponding biopsy hematoxylin-eosin-stained slide images. Data analysis was conducted from January 15, 2017, to February 14, 2019. Main Outcomes and Measures: Evaluation of imaging signatures by the area under the receiver operating characteristic curve (AUC) in identifying HER2+ molecular subtypes and distinguishing pathologic complete response (ypT0/is) to NAC with HER2-targeting. Results: In the 209 patients included (mean [SD] age, 51.1 [11.7] years), features from the peritumoral regions better discriminated HER2-E tumors (maximum AUC, 0.85; 95% CI, 0.79-0.90; 9-12 mm from the tumor) compared with intratumoral features (AUC, 0.76; 95% CI, 0.69-0.84). A classifier combining peritumoral and intratumoral features identified the HER2-E subtype (AUC, 0.89; 95% CI, 0.84-0.93) and was significantly associated with response to HER2-targeted therapy in both validation cohorts (AUC, 0.80; 95% CI, 0.61-0.98 and AUC, 0.69; 95% CI, 0.53-0.84). Features from the 0- to 3-mm peritumoral region were significantly associated with the density of tumor-infiltrating lymphocytes (R2 = 0.57; 95% CI, 0.39-0.75; P = .002). Conclusions and Relevance: A combination of peritumoral and intratumoral characteristics appears to identify intrinsic molecular subtypes of HER2+ breast cancers from imaging, offering insights into immune response within the peritumoral environment and suggesting potential benefit for treatment guidance.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Imageamento por Ressonância Magnética/estatística & dados numéricos , Radiometria/estatística & dados numéricos , Receptor ErbB-2/metabolismo , Adulto , Biomarcadores Tumorais/análise , Neoplasias da Mama/metabolismo , Feminino , Humanos , Linfócitos do Interstício Tumoral/patologia , Pessoa de Meia-Idade , Terapia Neoadjuvante , Período Pré-Operatório , Estudos Retrospectivos , Resultado do Tratamento
6.
BMC Med Imaging ; 19(1): 22, 2019 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-30819131

RESUMO

BACKGROUND: For most computer-aided diagnosis (CAD) problems involving prostate cancer detection via medical imaging data, the choice of classifier has been largely ad hoc, or been motivated by classifier comparison studies that have involved large synthetic datasets. More significantly, it is currently unknown how classifier choices and trends generalize across multiple institutions, due to heterogeneous acquisition and intensity characteristics (especially when considering MR imaging data). In this work, we empirically evaluate and compare a number of different classifiers and classifier ensembles in a multi-site setting, for voxel-wise detection of prostate cancer (PCa) using radiomic texture features derived from high-resolution in vivo T2-weighted (T2w) MRI. METHODS: Twelve different supervised classifier schemes: Quadratic Discriminant Analysis (QDA), Support Vector Machines (SVMs), naïve Bayes, Decision Trees (DTs), and their ensemble variants (bagging, boosting), were compared in terms of classification accuracy as well as execution time. Our study utilized 85 prostate cancer T2w MRI datasets acquired from across 3 different institutions (1 for discovery, 2 for independent validation), from patients who later underwent radical prostatectomy. Surrogate ground truth for disease extent on MRI was established by expert annotation of pre-operative MRI through spatial correlation with corresponding ex vivo whole-mount histology sections. Classifier accuracy in detecting PCa extent on MRI on a per-voxel basis was evaluated via area under the ROC curve. RESULTS: The boosted DT classifier yielded the highest cross-validated AUC (= 0.744) for detecting PCa in the discovery cohort. However, in independent validation, the boosted QDA classifier was identified as the most accurate and robust for voxel-wise detection of PCa extent (AUCs of 0.735, 0.683, 0.768 across the 3 sites). The next most accurate and robust classifier was the single QDA classifier, which also enjoyed the advantage of significantly lower computation times compared to any of the other methods. CONCLUSIONS: Our results therefore suggest that simpler classifiers (such as QDA and its ensemble variants) may be more robust, accurate, and efficient for prostate cancer CAD problems, especially in the context of multi-site validation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Diagnóstico por Computador , Análise Discriminante , Humanos , Bloqueio Interatrial , Masculino , Reconhecimento Automatizado de Padrão , Neoplasias da Próstata/patologia , Curva ROC , Sensibilidade e Especificidade , Máquina de Vetores de Suporte
7.
Adv Radiat Oncol ; 3(2): 181-189, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29904743

RESUMO

OBJECTIVES: Understanding the drivers of delays from diagnosis to treatment can elucidate how to reduce the time to treatment (TTT) in patients with prostate cancer. In addition, the available treatments depending on the stage of cancer can vary widely for many reasons. This study investigated the relationship of TTT and treatment choice with sociodemographic factors in patients with prostate cancer who underwent external beam radiation therapy (RT), radical prostatectomy (RP), androgen deprivation therapy (ADT), or active surveillance (AS) at a safety-net academic medical center. METHODS AND MATERIALS: A retrospective review was performed on 1088 patients who were diagnosed with nonmetastatic prostate cancer between January 2005 and December 2013. Demographic data as well as data on TTT, initial treatment choice, American Joint Committee on Cancer stage, and National Comprehensive Cancer Network risk categories were collected. Analyses of variance and multivariable logistic regression models were performed to analyze the relationship of these factors with treatment choice and TTT. RESULTS: Age, race, and marital status were significantly related to treatment choice. Patients who were nonwhite and older than 60 years were less likely to undergo RP. Black patients were 3.8 times more likely to undergo RT compared with white patients. The median TTT was 75 days. Longer time delays were significant in patients of older age, nonwhite race/ethnicity, non-English speakers, those with noncommercial insurance, and those with non-married status. The average TTT of high-risk patients was 25 days longer than that of low-risk patients. Patients who underwent RT had an average TTT that was 34 days longer than that of RP patients. CONCLUSIONS: The treatment choice and TTT of patients with prostate cancer are affected by demographic factors such as age, race, marital status, and insurance, as well as clinical factors including stage and risk category of disease.

8.
Artigo em Inglês | MEDLINE | ID: mdl-30775692

RESUMO

This paper presents the design evolution, fabrication, and testing of a novel patient and organ-specific, 3D printed phantom for external beam radiation therapy of prostate cancer. In contrast to those found in current practice, this phantom can be used to plan and validate treatment tailored to an individual patient. It contains a model of the prostate gland with a dominant intraprostatic lesion, seminal vesicles, urethra, ejaculatory duct, neurovascular bundles, rectal wall, and penile bulb generated from a series of combined T2-weighted/dynamic contrast-enhanced magnetic resonance images. The iterative process for designing the phantom based on user interaction and evaluation is described. Using the CyberKnife System at Boston Medical Center a treatment plan was successfully created and delivered. Dosage delivery results were validated through gamma index calculations based on radiochromic film measurements which yielded a 99.8% passing rate. This phantom is a demonstration of a methodology for incorporating high-contrast magnetic resonance imaging into computed-tomography-based radiotherapy treatment planning; moreover, it can be used to perform quality assurance.

9.
Bone Joint J ; 99-B(7): 917-920, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28663397

RESUMO

AIMS: Infection following total hip or knee arthroplasty is a serious complication. We noted an increase in post-operative infection in cases carried out in temporary operating theatres. We therefore compared those cases performed in standard and temporary operating theatres and examined the deep periprosthetic infection rates. PATIENTS AND METHODS: A total of 1223 primary hip and knee arthroplasties were performed between August 2012 and June 2013. A total of 539 (44%) were performed in temporary theatres. The two groups were matched for age, gender, body mass index and American Society of Anesthesiologists grade. RESULTS: The deep infection rate for standard operating theatres was 0 of 684 (0%); for temporary theatres it was eight of 539 (1.5%) (p = 0.001). CONCLUSION: Use of a temporary operating theatre for primary hip and knee arthroplasty was associated with an unacceptable increase in deep infection. We do not advocate the use of these theatres for primary joint arthroplasty. Cite this article: Bone Joint J 2017;99-B:917-20.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Infecção Hospitalar/epidemiologia , Salas Cirúrgicas , Infecções Relacionadas à Prótese/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Movimentos do Ar , Contaminação de Equipamentos , Humanos , Estudos Retrospectivos , Fatores de Risco , Reino Unido/epidemiologia
10.
Eur Radiol ; 27(11): 4797-4803, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28526892

RESUMO

OBJECTIVES: To evaluate breast biopsy marker migration in stereotactic core needle biopsy procedures and identify contributing factors. METHODS: This retrospective study analyzed 268 stereotactic biopsy markers placed in 263 consecutive patients undergoing stereotactic biopsies using 9G vacuum-assisted devices from August 2010-July 2013. Mammograms were reviewed and factors contributing to marker migration were evaluated. Basic descriptive statistics were calculated and comparisons were performed based on radiographically-confirmed marker migration. RESULTS: Of the 268 placed stereotactic biopsy markers, 35 (13.1%) migrated ≥1 cm from their biopsy cavity. Range: 1-6 cm; mean (± SD): 2.35 ± 1.22 cm. Of the 35 migrated biopsy markers, 9 (25.7%) migrated ≥3.5 cm. Patient age, biopsy pathology, number of cores, and left versus right breast were not associated with migration status (P> 0.10). Global fatty breast density (P= 0.025) and biopsy in the inner region of breast (P = 0.031) were associated with marker migration. Superior biopsy approach (P= 0.025), locally heterogeneous breast density, and t-shaped biopsy markers (P= 0.035) were significant for no marker migration. CONCLUSIONS: Multiple factors were found to influence marker migration. An overall migration rate of 13% supports endeavors of research groups actively developing new biopsy marker designs for improved resistance to migration. KEY POINTS: • Breast biopsy marker migration is documented in 13% of 268 procedures. • Marker migration is affected by physical, biological, and pathological factors. • Breast density, marker shape, needle approach etc. affect migration. • Study demonstrates marker migration prevalence; marker design improvements are needed.


Assuntos
Biópsia com Agulha de Grande Calibre/instrumentação , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Migração de Corpo Estranho/diagnóstico por imagem , Mamografia , Biópsia com Agulha de Grande Calibre/métodos , Mama/patologia , Densidade da Mama , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
J Appl Clin Med Phys ; 18(3): 37-43, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28407345

RESUMO

PURPOSE: In SBRT for prostate cancer, higher fractional dose to the rectum is a major toxicity concern due to using smaller PTV margin and hypofractionation. We investigate the dosimetric impact on rectum using endorectal balloon (ERB) in prostate SBRT. MATERIALS AND METHODS: Twenty prostate cancer patients were included in a retrospective study, ten with ERB and 10 without ERB. Optimized SBRT plans were generated on CyberKnife MultiPlan for 5 × 7.25 Gy to PTV under RTOG-0938 protocol for early-stage prostate cancer. For the rectum and the anterior half rectum, mean dose and percentage of volumes receiving 50%, 80%, 90%, and 100% prescription dose were compared. RESULTS: Using ERB, mean dose to the rectum was 62 cGy (P = 0.001) lower per fraction, and 50 cGy (P = 0.024) lower per fraction for the anterior half rectum. The average V50% , V80% , V90% , and V100% were lower by 9.9% (P = 0.001), 5.3% (P = 0.0002), 3.4% (P = 0.0002), and 1.2% (P = 0.005) for the rectum, and lower by 10.4% (P = 0.009), 8.3% (P = 0.0004), 5.4% (P = 0.0003), and 2.1% (P = 0.003) for the anterior half rectum. CONCLUSIONS: Significant reductions of dose to the rectum using ERB were observed. This may lead to improvement of the rectal toxicity profiles in prostate SBRT.


Assuntos
Neoplasias da Próstata/radioterapia , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Reto/efeitos da radiação , Humanos , Masculino , Neoplasias da Próstata/patologia , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radiometria , Estudos Retrospectivos
12.
Sci Rep ; 6: 21394, 2016 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-26887643

RESUMO

To identify computer extracted imaging features for estrogen receptor (ER)-positive breast cancers on dynamic contrast enhanced (DCE)-MRI that are correlated with the low and high OncotypeDX risk categories. We collected 96 ER-positive breast lesions with low (< 18, N = 55) and high (> 30, N = 41) OncotypeDX recurrence scores. Each lesion was quantitatively characterize via 6 shape features, 3 pharmacokinetics, 4 enhancement kinetics, 4 intensity kinetics, 148 textural kinetics, 5 dynamic histogram of oriented gradient (DHoG), and 6 dynamic local binary pattern (DLBP) features. The extracted features were evaluated by a linear discriminant analysis (LDA) classifier in terms of their ability to distinguish low and high OncotypeDX risk categories. Classification performance was evaluated by area under the receiver operator characteristic curve (Az). The DHoG and DLBP achieved Az values of 0.84 and 0.80, respectively. The 6 top features identified via feature selection were subsequently combined with the LDA classifier to yield an Az of 0.87. The correlation analysis showed that DHoG (ρ = 0.85, P < 0.001) and DLBP (ρ = 0.83, P < 0.01) were significantly associated with the low and high risk classifications from the OncotypeDX assay. Our results indicated that computer extracted texture features of DCE-MRI were highly correlated with the high and low OncotypeDX risk categories for ER-positive cancers.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/genética , Genômica , Imageamento por Ressonância Magnética , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Receptores de Estrogênio , Medição de Risco
13.
Eur Radiol ; 26(3): 866-73, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26060064

RESUMO

OBJECTIVES: To develop a breast biopsy marker that resists fast and slow migration and has permanent visibility under commonly used imaging modalities. METHODS: A polymer-nanoparticle composite film was prepared by embedding superparamagnetic iron oxide nanoparticles and a superelastic Nitinol wire within a flexible polyethylene matrix. MRI, mammography, and ultrasound were used to visualize the marker in agar, ex vivo chicken breast, bovine liver, brisket, and biopsy training phantoms. Fast migration caused by the "accordion effect" was quantified after simulated stereotactic, vacuum-assisted core biopsy/marker placement, and centrifugation was used to simulate accelerated long-term (i.e., slow) migration in ex vivo bovine tissue phantoms. RESULTS: Clear marker visualization under MRI, mammography, and ultrasound was observed. After deployment, the marker partially unfolds to give a geometrically constrained structure preventing fast and slow migration. The marker can be deployed through an 11G introducer without fast migration occurring, and shows substantially less slow migration than conventional markers. CONCLUSION: The polymer-nanoparticle composite biopsy marker is clearly visible on all clinical imaging modalities and does not show substantial migration, which ensures multimodal assessment of the correct spatial information of the biopsy site, allowing for more accurate diagnosis and treatment planning and improved breast cancer patient care. KEY POINTS: Polymer-nanoparticle composite biopsy markers are visualized using ultrasound, MRI, and mammography. Embedded iron oxide nanoparticles provide tuneable contrast for MRI visualization. Permanent ultrasound visibility is achieved with a non-biodegradable polymer having a distinct ultrasound signal. Flexible polymer-based biopsy markers undergo shape change upon deployment to minimize migration. Non-migrating multimodal markers will help improve accuracy of pre/post-treatment planning studies.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Nanopartículas de Magnetita , Polímeros , Animais , Biópsia por Agulha/métodos , Bovinos , Feminino , Humanos , Biópsia Guiada por Imagem , Fígado , Imageamento por Ressonância Magnética/instrumentação , Mamografia/instrumentação , Imagem Multimodal , Imagens de Fantasmas , Aves Domésticas , Instrumentos Cirúrgicos , Ultrassonografia Mamária
15.
J Contemp Brachytherapy ; 6(4): 337-43, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25834576

RESUMO

PURPOSE: To assess detailed dosimetry data for prostate and clinical relevant intra- and peri-prostatic structures including neurovascular bundles (NVB), urethra, and penile bulb (PB) from postbrachytherapy computed tomography (CT) versus high resolution contrast enhanced magnetic resonance imaging (HR-CEMRI). MATERIAL AND METHODS: Eleven postbrachytherapy prostate cancer patients underwent HR-CEMRI and CT imaging. Computed tomography and HR-CEMRI images were randomized and 2 independent expert readers created contours of prostate, intra- and peri-prostatic structures on each CT and HR-CEMRI scan for all 11 patients. Dosimetry data including V100, D90, and D100 was calculated from these contours. RESULTS: Mean V100 values from CT and HR-CEMRI contours were as follows: prostate (98.5% and 96.2%, p = 0.003), urethra (81.0% and 88.7%, p = 0.027), anterior rectal wall (ARW) (8.9% and 2.8%, p < 0.001), left NVB (77.9% and 51.5%, p = 0.002), right NVB (69.2% and 43.1%, p = 0.001), and PB (0.09% and 11.4%, p = 0.005). Mean D90 (Gy) derived from CT and HR-CEMRI contours were: prostate (167.6 and 150.3, p = 0.012), urethra (81.6 and 109.4, p = 0.041), ARW (2.5 and 0.11, p = 0.003), left NVB (98.2 and 58.6, p = 0.001), right NVB (87.5 and 55.5, p = 0.001), and PB (11.2 and 12.4, p = 0.554). CONCLUSIONS: Findings of this study suggest that HR-CEMRI facilitates accurate and meaningful dosimetric assessment of prostate and clinically relevant structures, which is not possible with CT. Significant differences were seen between CT and HR-CEMRI, with volume overestimation of CT derived contours compared to HR-CEMRI.

16.
Med Phys ; 42(3): 1153-63, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25735270

RESUMO

PURPOSE: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. In this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. METHODS: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. RESULTS: MAPPER was evaluated on 13 patient studies from two independent datasets­Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2. State-of-the-art MRI-TRUS fusion methods report RMSE of 3.06-2.07 mm. CONCLUSIONS: MAPPER aligns MRI and TRUS imagery without manual intervention ensuring efficient, reproducible registration. MAPPER has a similar RMSE to state-of-the-art methods that require manual intervention.


Assuntos
Elasticidade , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Humanos , Biópsia Guiada por Imagem , Masculino , Probabilidade , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Ultrassonografia
17.
J Magn Reson Imaging ; 41(5): 1383-93, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24943647

RESUMO

PURPOSE: To identify computer-extracted features for central gland and peripheral zone prostate cancer localization on multiparametric magnetic resonance imaging (MRI). MATERIALS AND METHODS: Preoperative T2-weighted (T2w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) MRI were acquired from 23 men with confirmed prostate cancer. Following radical prostatectomy, the cancer extent was delineated by a pathologist on ex vivo histology and mapped to MRI by nonlinear registration of histology and corresponding MRI slices. In all, 244 computer-extracted features were extracted from MRI, and principal component analysis (PCA) was employed to reduce the data dimensionality so that a generalizable classifier could be constructed. A novel variable importance on projection (VIP) measure for PCA (PCA-VIP) was leveraged to identify computer-extracted MRI features that discriminate between cancer and normal prostate, and these features were used to construct classifiers for cancer localization. RESULTS: Classifiers using features selected by PCA-VIP yielded an area under the curve (AUC) of 0.79 and 0.85 for peripheral zone and central gland tumors, respectively. For tumor localization in the central gland, T2w, DCE, and DWI MRI features contributed 71.6%, 18.1%, and 10.2%, respectively; for peripheral zone tumors T2w, DCE, and DWI MRI contributed 29.6%, 21.7%, and 48.7%, respectively. CONCLUSION: PCA-VIP identified relatively stable subsets of MRI features that performed well in localizing prostate cancer on MRI.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Neoplasias da Próstata/patologia , Idoso , Interpretação Estatística de Dados , Humanos , Aumento da Imagem/métodos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Neurocomputing (Amst) ; 144: 24-37, 2014 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-25225455

RESUMO

In this work, we present a novel learning based fiducial driven registration (LeFiR) scheme which utilizes a point matching technique to identify the optimal configuration of landmarks to better recover deformation between a target and a moving image. Moreover, we employ the LeFiR scheme to model the localized nature of deformation introduced by a new treatment modality - laser induced interstitial thermal therapy (LITT) for treating neurological disorders. Magnetic resonance (MR) guided LITT has recently emerged as a minimally invasive alternative to craniotomy for local treatment of brain diseases (such as glioblastoma multiforme (GBM), epilepsy). However, LITT is currently only practised as an investigational procedure world-wide due to lack of data on longer term patient outcome following LITT. There is thus a need to quantitatively evaluate treatment related changes between post- and pre-LITT in terms of MR imaging markers. In order to validate LeFiR, we tested the scheme on a synthetic brain dataset (SBD) and in two real clinical scenarios for treating GBM and epilepsy with LITT. Four experiments under different deformation profiles simulating localized ablation effects of LITT on MRI were conducted on 286 pairs of SBD images. The training landmark configurations were obtained through 2000 iterations of registration where the points with consistently best registration performance were selected. The estimated landmarks greatly improved the quality metrics compared to a uniform grid (UniG) placement scheme, a speeded-up robust features (SURF) based method, and a scale-invariant feature transform (SIFT) based method as well as a generic free-form deformation (FFD) approach. The LeFiR method achieved average 90% improvement in recovering the local deformation compared to 82% for the uniform grid placement, 62% for the SURF based approach, and 16% for the generic FFD approach. On the real GBM and epilepsy data, the quantitative results showed that LeFiR outperformed UniG by 28% improvement in average.

19.
Med Phys ; 41(7): 072301, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24989400

RESUMO

PURPOSE: In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. Statistical imaging atlases allow for the integration of information across multiple scales and imaging modalities into a single canonical representation, in turn enabling a fused anatomical-disease representation which may facilitate the characterization of disease appearance relative to anatomic structures. While statistical atlases have been extensively developed and studied for the brain, approaches that have attempted to combine pathology and imaging data for study of prostate pathology are not extant. This works seeks to address this gap. METHODS: The AnCoR framework optimizes a scoring function composed of two surface (prostate and central gland) misalignment measures and one intensity-based similarity term. This ensures the correct mapping of anatomic regions into the atlas, even when regional MRI intensities are inconsistent or highly variable between subjects. The framework allows for creation of an anatomic imaging and a disease atlas, while enabling their fusion into the anatomic imaging-disease atlas. The atlas presented here was constructed using 83 subjects with biopsy confirmed cancer who had pre-operative MRI (collected at two institutions) followed by radical prostatectomy. The imaging atlas results from mapping thein vivo MRI into the canonical space, while the anatomic regions serve as domain constraints. Elastic co-registration MRI and corresponding ex vivo histology provides "ground truth" mapping of cancer extent on in vivo imaging for 23 subjects. RESULTS: AnCoR was evaluated relative to alternative construction strategies that use either MRI intensities or the prostate surface alone for registration. The AnCoR framework yielded a central gland Dice similarity coefficient (DSC) of 90%, and prostate DSC of 88%, while the misalignment of the urethra and verumontanum was found to be 3.45 mm, and 4.73 mm, respectively, which were measured to be significantly smaller compared to the alternative strategies. As might have been anticipated from our limited cohort of biopsy confirmed cancers, the disease atlas showed that most of the tumor extent was limited to the peripheral zone. Moreover, central gland tumors were typically larger in size, possibly because they are only discernible at a much later stage. CONCLUSIONS: The authors presented the AnCoR framework to explicitly model anatomic constraints for the construction of a fused anatomic imaging-disease atlas. The framework was applied to constructing a preliminary version of an anatomic-disease atlas of the prostate, the prostatome. The prostatome could facilitate the quantitative characterization of gland morphology and imaging features of prostate cancer. These techniques, may be applied on a large sample size data set to create a fully developed prostatome that could serve as a spatial prior for targeted biopsies by urologists. Additionally, the AnCoR framework could allow for incorporation of complementary imaging and molecular data, thereby enabling their careful correlation for population based radio-omics studies.


Assuntos
Atlas como Assunto , Imageamento por Ressonância Magnética , Próstata/anatomia & histologia , Próstata/patologia , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia
20.
Bone Joint J ; 96-B(1): 122-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24395322

RESUMO

Since the introduction of the National Institute for Health and Care Excellence (NICE) guidelines on thromboprophylaxis and the use of extended thromboprophylaxis with new oral agents, there have been reports of complications arising as a result of their use. We have looked at the incidence of wound complications after the introduction of dabigatran for thromboprophylaxis in our unit. We investigated the rate of venous thromboembolism and wound leakage in 1728 patients undergoing primary joint replacement, both before and after the introduction of dabigatran, and following its subsequent withdrawal from our unit. We found that the use of dabigatran led to a significant increase in post-operative wound leakage (20% with dabigatran, 5% with a multimodal regimen; p < 0.001), which also resulted in an increased duration of hospital stay. The rate of thromboembolism in patients receiving dabigatran was higher (1.3%) than in those receiving the multimodal thromboprophylaxis regimen, including low molecular weight heparin as an inpatient and the extended use of aspirin (0.3%, p = 0.047). We have ceased the use of dabigatran for thromboprophylaxis in these patients.


Assuntos
Antitrombinas/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Benzimidazóis/efeitos adversos , Hemorragia Pós-Operatória/induzido quimicamente , Tromboembolia Venosa/prevenção & controle , beta-Alanina/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Antitrombinas/uso terapêutico , Aspirina/uso terapêutico , Benzimidazóis/uso terapêutico , Dabigatrana , Quimioterapia Combinada , Feminino , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Tempo de Internação , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/efeitos adversos , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Tromboembolia Venosa/etiologia , beta-Alanina/efeitos adversos , beta-Alanina/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...