Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Shoulder Elbow ; 12(1 Suppl): 40-52, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33343715

RESUMO

BACKGROUND: Glenoid component failures still represent the most common complication in total shoulder arthroplasty. These failures depend on several factors, including ultra-high molecular weight polyethylene (UHMWPE) wear. One reason for UHMWPE wear in total shoulder arthroplasty may be the current use of a spherical prosthetic humeral head against a radially mismatched UHMWPE glenoid component, which leads to reduced glenohumeral translations, glenoid edge loading and high translational forces during shoulder motions. The aim of this study was to assess the in vitro wear of an anatomic total shoulder prosthesis with non-spherical non-conforming bearings with inverted conventional materials. METHODS: The wear of a vitamin E-blended UHMWPE non-spherical humeral head articulating against a non-conforming titanium-niobium nitride (TiNbN)-coated metallic glenoid was tested using a joint simulator. The wear test was performed by applying a constant load of 756 N with angular motions and translations. RESULTS: After 2.5 million cycles, the mean wear rate of the humeral head was 0.28 ± standard deviation (SD) 0.45 mg/million cycles. CONCLUSION: The low wear rate of the vitamin E UHMWPE humeral head supports the use of non-spherical non-conforming bearings with inverted conventional materials in anatomic total shoulder arthroplasty.

2.
BMC Musculoskelet Disord ; 18(1): 9, 2017 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-28068966

RESUMO

BACKGROUND: Placement of the glenoid baseplate is of paramount importance for the outcome of anatomical and reverse total shoulder arthroplasty. However, the database around glenoid size is poor, particularly regarding small scapulae, for example, in women and smaller individuals, and is derived from different methodological approaches. In this multimodality cadaver study, we systematically examined the glenoid using morphological and 3D-CT measurements. METHODS: Measurements of the glenoid and drill hole tunnel length for superior baseplate screw placement were recorded to define size of the glenoid and the distance to the scapular notch on cadaveric specimens. Glenoid angles were determined on both, 3D-CT-scans of the thoraxes using the Friedman method and on subsequently isolated scapulae from 18 male and female donors (average 84 years, range 60-98 years). RESULTS: Mean glenoid height was 36.6 mm ± 3.6, and width 27.8 mm ± 3.1 with a significant sex dimorphism (p ≤ 0.001): in males, glenoid height 39.5 mm ± 3.5, and width 30.3 mm ± 3.3, and in females, glenoid height 34.8 mm ± 2.2, and width 26.2 mm ± 1.6. The average distance from the superior screw entry to its exit in the scapular notch measured by calliper was 27.2 mm ± 6.0 with a sex difference: in males, 29.4 mm ± 5.7, and in females, 25.8 mm ± 5.9 mm with a minimum recorded distance of 15 mm. Measured by CT, the mean inclination angle for male and female donors combined was 13.0° ± 7.0, and the ante-/retroversion angle -1.0° ± 4.0°. CONCLUSION: This study is one of the first to combine dissection, including drill holes, with anatomical measurements and radiological data. In some women and smaller individuals, smaller baseplates should be selected. The published safe zone of 20 mm is generally feasible for superior screw placement, however, in small patients this distance may be substantially shorter than expected and start as of 13 and 15 mm, respectively. No correlation between glenoid height or width with the length of our drilling canal towards the scapular notch was found. Preoperative CT-based treatment planning to determine version and inclination angles is recommended.


Assuntos
Artroplastia do Ombro/métodos , Dissecação/métodos , Cavidade Glenoide/anatomia & histologia , Cavidade Glenoide/diagnóstico por imagem , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Cavidade Glenoide/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/patologia
3.
Open Orthop J ; 6: 172-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22582104

RESUMO

BACKGROUND: Total knee arthroplasty can be considered as a reliable surgical procedure with a good long-term clinical result. However, implant failure due to particle induced aseptic loosening as well as the aspect of hypersensitivity to metal ions still remains an emerging issue. METHODS: The purpose of this prospective international multi-centre study was to evaluate the clinical and radiological outcomes and the reliability of the unconstrained Multigen Plus Total Knee System with a new BIOLOX® delta ceramic femoral component. Cemented total knee arthroplasty was performed on 108 patients (110 knees) at seven hospitals in three countries. Clinical and radiological evaluations were performed preoperatively, and after 3, 12 and 24 months postoperatively using the HSS-, WOMAC-, SF-36-score and standardised X-rays. RESULTS: The mean preoperative HSS-Score amounted to 55.5 ± 11.5 points and improved significantly in all postoperative evaluations (85.7 ± 11.7 points at 24 months). Furthermore, improvements in WOMAC- and SF-36-score were evaluated as significant at all points of evaluation. Radiolucent lines around the femoral ceramic component at 24 months were found in four cases. Progression of radiolucent lines was not seen and no implant loosening was observed. During the 24 month follow-up eight patients underwent subsequent surgery due to reasons unrelated to the implant material. CONCLUSIONS: The observed clinical and radiological results are encouraging for a long-term survival of the ceramic femoral component. Therefore, ceramic implants could be a promising solution not only for patients with allergies against metallic implant materials, but also for the osteoarthritic knee joint. Long-term follow-up is necessary to draw conclusions regarding the superiority of the ceramic knee implants concerning in vivo wear and long-term survivorship.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...