Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Eur J Radiol ; 156: 110520, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36116141

RESUMO

PURPOSE: This study analyzes the value of dynamic contrast-enhanced MRI (DCE) of the prostate on 1.5 T and 3 T examinations in patients within PI-RADS category 4. METHODS: In this retrospective, bi-centric, cohort study all consecutive patients classified as PI-RADS 4 in mpMRI with 100 verified prostate cancers (PCa) in subsequent MRI/US-guided fusion biopsy were included for 1.5 T and 3 T, each. PCa detection in index lesions (IL) upgraded to PI-RADS 4 based on positive DCE findings was compared between 1.5 T and 3 T. Secondary objectives are subgroup analysis of PZ lesions and comparison of ISUP grade group distribution between 1.5 T and 3 T. RESULTS: In total, 293 patients within PI-RADS category 4, including 152 (mean 66 ± 8y; median PSA 6.4 ng/ml;116 PZ IL) in the 1.5 T group and 141 (mean 65 ± 8y; median PSA 7.2 ng/ml;100 PZ IL) in the 3 T group were included. Overall amount of PCa (66 % vs 71 %; p = 0.346) and portion of upgraded IL (28 % vs 21 %; p = 0.126) did not differ significantly. At 1.5 T PCa detection was higher in upgraded PZ lesions compared to 3 T (23 % vs 14 %; p = 0.048). The amount of upgraded PZ lesions with ISUP grade group 2-5 PCa was significantly higher at 1.5 T versus 3 T (13.8 % vs 4.0 %; p = 0.007). 33 % (11/33; 1.5 T) and 32 % (10/31; 3 T) of the ISUP grade group 1 PCa of the PZ lesions were detected in upgraded lesions (10% of all PZ index lesions, respectively). CONCLUSION: DCE enabled the detection of a substantial amount of additional clinically significant PCa in prostate mpMRI at 1.5 T. The effect was smaller at 3 T and was accompanied in relation to 1.5 T by higher risk of overdiagnosis due to detection of additional low-risk PCa.

2.
Eur J Radiol ; 144: 109949, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34537450

RESUMO

PURPOSE: To evaluate image quality and diagnostic value of multiparametric prostate MRI (mpMRI) in patients with total hip replacement (THR) at 1.5 and 3 Tesla. METHODS: In this retrospective multicenter cohort study patients with uni- or bilateral THR and 1.5 T or 3 T mpMRI were included. Seventy consecutive, standard-of-care examinations per field strength were evaluated regarding their diagnostic value. The overall diagnostic value and prostate imaging quality score (PI-QUAL) were assessed. Artifact severity in the localizer and mpMRI sequences (T2w, DWI, DCE) was scored on a 3-point scale. Correlation between diagnostic value and artifacts was analysed. Moreover, a subgroup analysis focussed on image quality at different 3 T scanner generations. RESULTS: 140 consecutive patients (mean age 72, median PSA value 8.3 ng/ml) were included. When comparing 1.5 T to 3 T examinations, no significant differences were observed regarding the artifact severity of DWI and the localizer and the overall diagnostic value of the images. There was a strong correlation between the diagnostic value, PI-QUAL score, and artifact severity in the localizer and DWI. T2w and DCE sequences showed overall low artifacts. Significant improvement in image quality for 3 T at the latest scanner generation was observed, especially for DWI (p < 0.03). CONCLUSIONS: MpMRI of patients with THR can be conducted at both field strengths without significant differences in artifacts. The localizer might be useful as an early forecasting feature for diagnostic value and particularly for contrast medium application decision. Patients with THR could benefit from technically advanced scanner generation and rs/ptx-EPI DWI sequences.


Assuntos
Artroplastia de Quadril , Neoplasias da Próstata , Idoso , Artefatos , Estudos de Coortes , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
3.
Eur Radiol ; 29(12): 6965-6970, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31250168

RESUMO

OBJECTIVES: To evaluate different analgesic techniques in MRI-guided in-bore prostate biopsy (IB-GB) regarding the influence on patient procedural experience of pain. METHODS: Two hundred fifty-two consecutive patients who had received an IB-GB either with intrarectal instillation of 2% lidocaine gel (n = 126, group A) or with periprostatic nerve block (PPNB) with 2% mepivacaine (n = 126, group B) were retrospectively included in this study. Pain scores were measured on a visual analog scale, the operating room time (ORT) was recorded for each biopsy and correlations between the parameters were analysed. RESULTS: Pain scores for IB-GB were slightly lower in group B compared with group A (2.0 ± 1.9; 2.4 ± 1.7; p = 0.02). In group A, significantly more targeted biopsy cores were acquired (group B: 5.2 ± 1.1; group A: 5.6 ± 0.8; p < 0.01). ORT was comparable and not significantly different in both groups. There was only a weak correlation between pain scores and ORT in group B (rS = 0.22; p = 0.01), but no correlation between pain scores and the number of biopsy cores or the prostate volume. CONCLUSIONS: Pain levels are generally low for MRI-guided in-bore biopsy using either PPNB or intrarectal instillation of lidocaine gel. A statistically significant, slightly lower pain score was documented for PPNB and might be preferred when the focus is analgesia. On the other hand, due to the minor difference and easier administration, intrarectal gel instillation seems to be a reasonable practice for standard analgesia for MRI-guided in-bore biopsy. KEY POINTS: • Pain levels were low for MRI-guided in-bore biopsy using either PPNB or intrarectal instillation of lidocaine gel as analgesic method. • PPNB prior to IB-GB resulted in a slightly lower pain score but required a higher effort. • Intrarectal gel anaesthesia seems to be a reasonable practice for standard analgesia for IB-GB in an outpatient setting.


Assuntos
Anestésicos Locais/administração & dosagem , Lidocaína/administração & dosagem , Mepivacaína/administração & dosagem , Dor/prevenção & controle , Próstata/patologia , Neoplasias da Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Analgesia/métodos , Biópsia com Agulha de Grande Calibre/efeitos adversos , Biópsia com Agulha de Grande Calibre/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/métodos , Duração da Cirurgia , Manejo da Dor , Medição da Dor , Estudos Retrospectivos
4.
Eur J Radiol ; 113: 1-6, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30927932

RESUMO

PURPOSE: To evaluate if subgroups of patients assigned to MRI category PI-RADS 4 regarding clinical and MRI imaging aspects have distinct risks of prostate cancer (PCa) to facilitate adequate clinical management of this population, especially after negative targeted biopsy. METHODS: This prospective, IRB approved single center cross-sectional study includes 931 consecutive patients after mp-MRI at 3 T for PCa detection. 193 patients with PI-RADS assessment category 4 received subsequent combined targeted MRI/US fusion-guided and systematic 12-core TRUS-guided biopsy as reference standard and were finally analyzed. The primary endpoint was PCa detection of PI-RADS 4 with MRI subgroup analyses. Secondary endpoints were analyses of clinical data, location of PCa, and detection of targeted biopsy cores. RESULTS: PCa was detected in 119 of 193 patients (62%) including clinically significant PCa (csPCa; Gleason score ≥3 + 4 = 7) in 92 patients (48%). MRI subgroup analysis revealed 95% PCa (73% csPCa) in unambiguous PI-RADS 4 index lesions without additional, interfering signs of prostatitis in the peripheral zone or overlaying signs of severe stromal hyperplasia in the transition zone according to PI-RADS v2. Transition zone confined PI-RADS-4-lesions with overlaying signs of stromal hyperplasia showed PCa only in 11% (4% csPCa). Targeted biopsy cores missed the csPCa index lesion in 7% of the patients. PSA density (PSAD) was significantly higher in PCa patients. CONCLUSIONS: Small csPCa can reliably be detected with mp-MRI by experienced readers, but can be missed by targeted MR/US fusion biopsy alone. Targeted re-biopsy of unambiguous (peripheral) PI-RADS-4-lesions is recommended; whereas transition zone confined PI-RADS-4-lesions with overlaying signs of stromal hyperplasia might be followed-up by re-MRI primarily.


Assuntos
Próstata/patologia , Neoplasias da Próstata/patologia , Prostatite/patologia , Idoso , Biópsia com Agulha de Grande Calibre/normas , Estudos Transversais , Humanos , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/normas , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Prospectivos
5.
Eur Radiol ; 28(1): 17-23, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28687912

RESUMO

OBJECTIVES: To prospectively evaluate the effect of hyoscine butylbromide (HBB) on visualisation of anatomical details and motion-related artefacts in mp-MRI of the prostate at 3.0 Tesla. METHODS: One hundred and three consecutive patients (65 ± 10 years) were included in this trial, powered to demonstrate an improvement of image quality after HBB administration, assessed on a 5-point scale by two blinded readers. All patients received high-spatial resolution axial T2-weighted TSE sequences at 3.0 T without spasmolytic agent, repeated after application of 40 mg HBB and followed by routine mp-MRI. Secondary endpoints were (1) susceptibility to side effects, (2) dependence of spasmolytic effect on patients´ weight, and (3) prostate volume. RESULTS: In 68% of patients, HBB significantly improved the anatomic score (mean 3.4 ± 0.9 before and 4.4 ± 0.7 after HBB for both readers, p = <0.001). In 67%, HBB significantly enhanced the artefact score (mean 3.2 ± 1 before and 4.2 ± 0.8 after HBB for reader 1, p = <0.001; 3.2 ± 1 and 4.1 ± 0.8 for reader 2, p = <0.001). Subgroup analysis revealed no statistically significant difference between patients with different bodyweight or prostate volume. Inter-reader agreement was excellent (k = 0.95-0.98). CONCLUSIONS: Hyoscine butylbromide significantly improves image quality and reduces motion-related artefacts in mp-MRI of the prostate independent of bodyweight or prostate volume. No side effects were reported. KEY POINTS: • Hyoscine butylbromide (HBB) improved image quality in over 2/3 of patients. • Severe artefacts were reduced after HBB in more than 20%. • The number of non-diagnostic MRI was reduced to <1% after HBB. • HBB effect was independent of bodyweight and prostate volume. • No side effects of HBB were reported in this study population.


Assuntos
Artefatos , Brometo de Butilescopolamônio/administração & dosagem , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Idoso , Humanos , Injeções Intravenosas , Imageamento por Ressonância Magnética/métodos , Masculino , Parassimpatolíticos/administração & dosagem , Curva ROC
6.
Eur J Radiol ; 90: 192-197, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28583633

RESUMO

OBJECTIVES: This study prospectively evaluates objective image quality (IQ), subjective IQ, and PI-RADS scoring of prostate MRI at 3.0T (3T) and 1.5T (1.5T) within the same patients. METHODS: Sixty-three consecutive patients (64±9years) were prospectively included in this non-inferiority trial, powered at 80% to demonstrate a ≤10% difference in signal-to-noise (SNR) and contrast-to-noise ratio (CNR) of T2-weighted and diffusion-weighted imaging (T2WI, DWI) at 1.5T compared to 3T. Secondary endpoints were analysis of subjective IQ and PI-RADS v2 scoring. RESULTS: All patients received multi-parametric prostate MRI on a 3T (T2WI, DWI, DCE) and bi-parametric MRI (T2WI, DWI) on a 1.5T scanner using body coils, respectively. SNR and CNR of T2WI were similar at 1.5T and 3T (p=0.7-1), but of DWI significantly lower at 1.5T (p<0.01). Subjective IQ was significantly better at 3T for both, T2WI and DWI (p<0.01). PI-RADS scores were comparable for both field strengths (p=0.05-1). Inter-reader agreement was excellent for subjective IQ assessment and PI-RADS scoring (k=0.9-1). CONCLUSION: Prostate MRI at 1.5T can reveal comparable objective image quality in T2WI, but is inferior to 3T in DWI and subjective IQ. However, similar PI-RADS scoring and thus diagnostic performance seems feasible independent of the field strength even without an endorectal coil.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
Eur Radiol ; 26(11): 3858-3864, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26920391

RESUMO

PURPOSE: This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. METHODS: Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. RESULTS: For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). CONCLUSION: The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. KEY POINTS: • Higher PI-RADS overall score (IV-V) correlated well with PCa detection rate • In more than 80 % SBC was concordant regarding overall PCa detection • In almost 90 % there was no Gleason upgrading by the SBC • Only 2/54 (3.7 %) csPCa was missed when the SBC was omitted • For IB-GB a further reduction of biopsy cores is reasonable.


Assuntos
Biópsia com Agulha de Grande Calibre/métodos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Idoso , Humanos , Masculino , Gradação de Tumores , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Pneumologie ; 69(2): 86-8, 2015 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-25588023

RESUMO

UNLABELLED: Cough is a common symptom in respiratory medicine. We report on a 60-year-old patient, who developed cough after pacemaker implantation. Diagnostic work up yielded malposition of the right-ventricular lead with penetration of the myocardium. Revision of the lead resulted in complete cessation of cough. CONCLUSION: Pacemaker dysfunction and/or malposition of pacemaker lead should be considered in differential diagnosis of cough after pacemaker implantation.


Assuntos
Tosse/diagnóstico , Tosse/etiologia , Eletrodos Implantados/efeitos adversos , Traumatismos Cardíacos/etiologia , Marca-Passo Artificial/efeitos adversos , Ferimentos Penetrantes/etiologia , Diagnóstico Diferencial , Traumatismos Cardíacos/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Raras/diagnóstico , Doenças Raras/etiologia , Resultado do Tratamento , Ferimentos Penetrantes/diagnóstico
9.
Z Gastroenterol ; 53(1): 28-32, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25594704

RESUMO

OBJECTIVE: The purpose of this study was to evaluate potential causes of Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. MATERIAL AND METHODS: We retrospectively evaluated 26 patients who required TIPS revision (group I) and 24 patients who did not require any further intervention (group II) within the first two years following TIPS implantation. The distance of the distal end of the stent to the hepatocaval junction was measured. Furthermore, the angle between the stent and the portal vein (inflow) and the angle between the stent and the hepatic vein (outflow) were measured. Furthermore, the following data were evaluated: pre- and postinterventional portal pressure gradients, maximal postinterventional flow and blood values [C-reactive protein (CRP), bilirubin, glutamic-oxaloacetic transaminase (GOT), glutamic-pyruvic transaminase (GPT)]. RESULTS: Compared with control subjects, patients who required TIPS revision showed a significantly longer distance from the distal end of the stent to the hepatocaval junction (I: 17.3 ±â€Š10 mm, II: 6.7 ±â€Š5.7 mm, p < 0.001). There was a statistically significant correlation between the above named distance and the time to revision (Pearson's correlation coefficient, r = 0.5, p = 0.01). In addition, patients with TIPS revision had a significantly larger angle of portalvenous inflow (alpha angle) than the control group (I: 100.5 ±â€Š31.5°, II: 64.5 ±â€Š31.6°, p < 0.001). CONCLUSION: Our results show that the distance from the end of the stent to the hepatocaval junction and the angle of portalvenous inflow are technical factors that may influence the shunt's patency rate. Of these two, the distance to the hepatocaval junction can be influenced easily by the interventionalist.


Assuntos
Sobrevivência de Enxerto/fisiologia , Veias Hepáticas/fisiologia , Circulação Hepática/fisiologia , Derivação Portossistêmica Transjugular Intra-Hepática , Stents , Grau de Desobstrução Vascular/fisiologia , Velocidade do Fluxo Sanguíneo , Análise de Falha de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
10.
Rofo ; 187(1): 19-28, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25226232

RESUMO

UNLABELLED: Adrenal disorders are relative frequent with regard to the incidence of adrenal tumors and the high portion in causes of secondary hypertension. Morphological changes in the adrenal glands can lead to very different functional disorders that may be clinically overt or hard to diagnose. On the other hand, they can already be functionally relevant when structural changes are too small to be picked up by imaging. Adrenal venous sampling serves to determine the source of hormone excess through the analysis of adrenal blood. In this manuscript, we call attention to the clinical backgrounds, critical points in praxis, technical aspects and developments in the the field of adrenal venous sampling. The consideration of these important points in the clincal setting may make adrenal vein sampling studies sucessful and help to select patients that qualify for adrenalectomy. KEY POINTS: • Selective adrenal venous sampling (AVS) currently continues to be the gold standard for localization diagnostics in patients with primary hyperaldosteronism. • Comprehensive standardization of all preceding examinations and AVS is necessary to ensure high success rates. • The method is supported by contrast-enhanced imaging for ensuring proper positioning of the catheter in the adrenal veins and the rapid cortisol assay. • Knowledge of the anatomy and normal variants of the adrenal veins facilitates adrenal venous sampling.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico , Glândulas Suprarrenais/irrigação sanguínea , Coleta de Amostras Sanguíneas/métodos , Cateterismo/métodos , Radiologia Intervencionista , Neoplasias das Glândulas Suprarrenais/sangue , Neoplasias das Glândulas Suprarrenais/cirurgia , Adrenalectomia , Coleta de Amostras Sanguíneas/instrumentação , Cateterismo/instrumentação , Síndrome de Cushing/sangue , Síndrome de Cushing/diagnóstico , Síndrome de Cushing/cirurgia , Diagnóstico Diferencial , Humanos , Hiperaldosteronismo/sangue , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/cirurgia , Hipertensão/sangue , Hipertensão/etiologia , Neoplasias Primárias Múltiplas/sangue , Neoplasias Primárias Múltiplas/diagnóstico , Neoplasias Primárias Múltiplas/cirurgia , Flebografia , Valor Preditivo dos Testes , Radiologia Intervencionista/instrumentação , Tomografia Computadorizada por Raios X
11.
Eur J Radiol ; 83(12): 2103-2108, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25241051

RESUMO

PURPOSE: This study evaluates the diagnostic value of the ESUR scoring system (PI-RADS) regarding prostate cancer detection using MR-guided in-bore biopsies (IB-GB) as the reference standard. METHODS: 566 lesions in 235 consecutive patients (65.7 ± 7.9 years, PSA 9.9 ± 8.5 ng/ml) with a multiparametric (mp)-MRI (T2WI, DWI, DCE) of the prostate at 3T were scored using the PI-RADS scoring system. PI-RADS single (PSsingle), summed (PSsum), and overall (PSoverall) scores were determined. All lesions were histologically verified by IB-GB. RESULTS: Lesions with a PSsum below 9 contained no prostate cancer (PCa) with Gleason score (GS) ≥ 4+3=7. A PSsum of 13-15 (PSoverall V) resulted in 87.8% (n=108) in PCa and in 42.3% (n=52) in GS ≥ 4+3=7. Transition zone (TZ) lesions with a PSsum of 13-15 (PSoverall V) resulted in 76.3% (n=36) in PCa and in 26.3% (n=10) in GS ≥ 4+3=7, whereas for peripheral zone (PZ) lesions cancer detection rate at this score was 92.9% (n=79) and 49.4% (n=42) for GS ≥ 4+3=7. Using a threshold of PSsum ≥ 10, sensitivity was 86.0%, and negative predictive value (NPV) was 86.2%. For higher grade PCa sensitivity was 98.6%, and NPV was 99.5%. CONCLUSION: A PSsum below 9 excluded a higher grade PCa, whereas lesions with a PSsum ≥ 13 (PSoverall V) represented in 88% PCa, and in 42% higher grade PCa. The PSsum or PSoverall demonstrated a better diagnostic value for PZ lesions with higher detection rates for higher grade PCa compared to TZ lesions.


Assuntos
Próstata/patologia , Neoplasias da Próstata/patologia , Idoso , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Neoplasias da Próstata/diagnóstico
12.
Eur Radiol ; 23(11): 3185-90, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23756958

RESUMO

OBJECTIVES: The recent European Society of Urogenital Radiology (ESUR) guidelines for evaluation and reporting of prostate multiparametric magnetic resonance imaging (mp-MRI) include the Prostate Imaging Reporting and Data System (PI-RADS). The aim of this study was to investigate the inter-reader agreement of this scoring system. METHODS: One hundred and sixty-four lesions in 67 consecutive patients with elevated prostate-specific antigen and previously negative trans-rectal ultrasound (TRUS)-guided biopsy were scored retrospectively by three blinded readers using PI-RADS. Mp-MRI was performed at 3 T using T2-weighted, diffusion-weighted and dynamic contrast-enhanced imagings (T2WI, DWI, DCE-MRI). Histology of all lesions was obtained by in-bore MRI-guided biopsy. Cohen's kappa statistics were calculated for all readers. RESULTS: Inter-reader agreement for all lesions was good to moderate (T2WI, κ = 0.55; DWI, κ = 0.64; DCE-MRI, κ = 0.65). For tumour lesions it was good (T2WI, κ = 0.66; DWI, κ = 0.80; DCE-MRI, κ = 0.63) and for benign lesions moderate to good (T2WI, κ = 0.46; DWI, κ = 0.52; DCE-MRI, κ = 0.67). Using an overall PI-RADS score with a threshold of ≥10, we achieved a sensitivity of 85.7 %, and negative predictive value of 90.1 % for biopsied lesions. CONCLUSION: PI-RADS score shows good to moderate inter-reader agreement and enables standardised evaluation of prostate mp-MRI, with high sensitivity and negative predictive value. KEY POINTS: • The European Society of Urogenital Radiology recently published guidelines for prostate MRI. • We have evaluated inter-reader agreement of ESUR scoring for multiparametric prostate MRI. • PI-RADS shows good to moderate inter-reader agreement and is clinically applicable. • PI-RADS achieves in our series high sensitivity and negative predictive value for biopsied lesions. • PI-RADS can be used as standardised scoring system in prostate cancer detection.


Assuntos
Biópsia Guiada por Imagem/normas , Imageamento por Ressonância Magnética/normas , Guias de Prática Clínica como Assunto , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Sociedades Médicas , Urologia , Idoso , Alemanha , Humanos , Masculino , Curva ROC , Padrões de Referência , Estudos Retrospectivos
13.
Dtsch Med Wochenschr ; 138(27): 1425-30, 2013 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-23801265

RESUMO

The incidence of hepatocellular carcinoma (HCC) is increasing worldwide due to the growing number of hepatitis C related HCCs. In more than 80% of the patients, HCC arises in a cirrhotic liver. Furthermore, more than half of the patients have an advanced Child-Pugh score or an inoperable tumor stage at the initial diagnosis. Recommendations for the treatment of HCC by national and international guidelines rely on the BCLC ("Barcelona Clinic for Liver Cancer") algorithm. Depending on the stage of liver function and tumor disease it recommends resection, liver transplantation, radiofrequency thermal ablation (RFA), transarterial chemoembolisation (TACE), systemic therapy with sorafenib or best supportive care, but does neither take into consideration combination of therapies nor new therapy modalities. However, there is increasing evidence that combinations i. e. sorafenib with TACE or combination of locoregional techniques enhance effectivity and tumor control compared to monotherapies. TACE with drug-eluting beads, selective internal radiotherapy (SIRT) and new locoregional therapy procedures like microwave ablation (MWA) are further promising therapeutic approaches. Patients with HCC should be discussed in a local tumor board in order to provide the optimal and most individual way of treatment.


Assuntos
Antineoplásicos/uso terapêutico , Carcinoma Hepatocelular/terapia , Ablação por Cateter/tendências , Quimioembolização Terapêutica/tendências , Neoplasias Hepáticas/terapia , Transplante de Fígado/tendências , Radioterapia/tendências , Terapia Combinada/tendências , Humanos
14.
Rofo ; 185(3): 253-61, 2013 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-23404430

RESUMO

PURPOSE: To flesh out the ESUR guidelines for the standardized interpretation of multiparametric magnetic resonance imaging (mMRI) for the detection of prostate cancer and to present a graphic reporting scheme for improved communication of findings to urologists. MATERIALS AND METHODS: The ESUR has recently published a structured reporting system for mMRI of the prostate (PI-RADS). This system involves the use of 5-point Likert scales for grading the findings obtained with different MRI techniques. The mMRI includes T2-weighted MRI, diffusion-weighted imaging, dynamic contrast-enhanced MRI, and MR spectroscopy. In a first step, the fundamentals of technical implementation were determined by consensus, taking into account in particular the German-speaking community. Then, representative images were selected by consensus on the basis of examinations of the three institutions. In addition, scoring intervals for an aggregated PI-RADS score were determined in consensus. RESULTS: The multiparametric methods were discussed critically with regard to implementation and the current status. Criteria used for grading mMRI findings with the PI-RADS classification were concretized by succinct examples. Using the consensus table for aggregated scoring in a clinical setting, a diagnosis of suspected prostate cancer should be made if the PI-RADS score is 4 or higher (≥ 10 points if 3 techniques are used or ≥ 13 points if 4 techniques are used). Finally, a graphic scheme was developed for communicating mMRI prostate findings. CONCLUSION: Structured reporting according to the ESUR guidelines contributes to quality assurance by standardizing prostate mMRI, and it facilities the communication of findings to urologists.


Assuntos
Comportamento Cooperativo , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Fidelidade a Diretrizes , Interpretação de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/normas , Comunicação Interdisciplinar , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Espectroscopia de Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/normas , Hiperplasia Prostática/classificação , Hiperplasia Prostática/diagnóstico , Neoplasias da Próstata/classificação , Neoplasias da Próstata/diagnóstico , Prostatite/classificação , Prostatite/diagnóstico , Garantia da Qualidade dos Cuidados de Saúde/normas , Biópsia , Consenso , Diagnóstico Diferencial , Humanos , Masculino , Neovascularização Patológica/classificação , Neovascularização Patológica/diagnóstico , Neovascularização Patológica/patologia , Próstata/irrigação sanguínea , Próstata/patologia , Neoplasias da Próstata/irrigação sanguínea
17.
Rofo ; 184(10): 925-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22744328

RESUMO

PURPOSE: Functional prostate MR is performed in varying combinations of T2-weighted images with diffusion-weighted imaging (DWI), dynamic contrast-enhanced MRI (DCE-MRI), and spectroscopic imaging (MRSI). Recently, a European consensus meeting proposed the use of a simple 5-point scale for estimating the probability of a lesion being malignant. The aim of the present study was to determine the inter-reader agreement of MR imaging using a scoring system based on the recommendations of the consensus. MATERIALS AND METHODS: The appearance of 108 predefined lesions in three different MR sequences (T2-weighted images, DWI, and DCE-MRI) in 50 functional prostate MR examinations were retrospectively scored by three blinded radiologists using a 5-point scale for each MR sequence. After scoring T2/DWI and T2/DWI/DCE-MRI, every lesion was graded based on its probability for malignancy. The inter-observer reliability was evaluated using Kappa statistics (ĸ). RESULTS: With respect to T2-weighted images, DWI and DCE-MRI ĸ was 0.49, 0.97, and 0.77, respectively. Combined scoring of T2-weighted images and DWI demonstrated correct tumor diagnosis (true positive) in 71-88% (depending on reader) of cases (ĸ=0.78). The accuracy was further improved to 88-96% after scoring all three MR sequences including DCE-MRI (ĸ=0.90). CONCLUSION: The use of a simple 5-point scoring system for T2-weighted images, DWI, and DCE-MRI is feasible in functional prostate MRI and has high inter-observer reliability.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/estatística & dados numéricos , Imagem Ecoplanar/métodos , Imagem Ecoplanar/estatística & dados numéricos , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Espectroscopia de Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/estatística & dados numéricos , Neoplasias da Próstata/diagnóstico , Projetos de Pesquisa/estatística & dados numéricos , Adulto , Idoso , Biópsia , Meios de Contraste/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Variações Dependentes do Observador , Probabilidade , Próstata/patologia , Sensibilidade e Especificidade
18.
Urol Int ; 89(1): 25-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22677880

RESUMO

BACKGROUND: Functional magnetic resonance imaging (MRI) seems to be a useful tool for prostate cancer (PCa) detection in patients with a previous negative biopsy but persistently increased prostate-specific antigen (PSA) values. Additionally, it enables correct cancer localization in patients with known PCa under active surveillance to avoid misclassification on repeat biopsies. Nevertheless, suspicious lesions on MRI findings need verification by biopsy. The aim of the present study was to establish a standardized functional prostate MRI reporting scheme. METHODS: Prostate MRI with T(2)-weighted images, T(1)-weighted images, diffusion-weighted imaging, and dynamic contrast-enhanced MRI of 56 consecutive patients were performed on a 3-T scanner. Patients with prior negative random transrectal ultrasound (TRUS)-guided biopsy and continuous suspicion for PCa as well as patients under active surveillance were included. The MRI localization report of suspicious lesions followed a standardized scheme. TRUS-guided random biopsy with addition of targeted biopsy cores was performed afterwards based on the structured report. RESULTS: Of the 56 patients, 18 had suspicious MRI findings and subsequently underwent repeat biopsy under guidance of the standardized localization scheme. PCa was documented in 72% (13/18). CONCLUSIONS: A standardized reporting scheme of suspicious findings on prostate MRI leads to higher success rates as compared to standard random TRUS-guided biopsy.


Assuntos
Imagem de Difusão por Ressonância Magnética/normas , Documentação/normas , Controle de Formulários e Registros/normas , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Conduta Expectante , Adulto , Idoso , Biópsia , Meios de Contraste , Reações Falso-Negativas , Reações Falso-Positivas , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Regulação para Cima
19.
Horm Metab Res ; 44(7): 527-32, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22689209

RESUMO

For the diagnosis of primary aldosteronism (PA), confirmatory testing is mandatory and different function tests can be employed. There are, however, sparse data comparing the fludrocortisone suppression test (FST) and the saline infusion test (SIT). Patients with PA (n=90) or essential hypertension (n=65) were studied. They underwent one or the other test or both of them. Using the DPC Siemens aldosterone radioimmunoassay, we found that the SIT led to a stronger suppression of aldosterone than the FST. Post-test aldosterone-to-renin ratios (ARRs) and the percentage of suppression of aldosterone serum concentrations performed worse. The same results were observed in patients who underwent both FST and SIT. Some patients had divergent results in both tests. For the SIT, a lower cutoff value should be used than for the FST for the adequate identification of patients with unilateral PA. Long-term prospective studies are needed to address the question at what cutoff values patients benefit from subtype differentiation of PA. We discuss here possible explanations for divergent results obtained with both tests.


Assuntos
Fludrocortisona , Hiperaldosteronismo/diagnóstico , Cloreto de Sódio/administração & dosagem , Aldosterona/sangue , Técnicas e Procedimentos Diagnósticos , Feminino , Humanos , Hiperaldosteronismo/fisiopatologia , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Curva ROC
20.
Urologe A ; 51(6): 848-56, 2012 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-22476739

RESUMO

BACKGROUND: The use of multi-parametric MRI and MRI-guided biopsy for the detection of prostate cancer is rapidly increasing. This is a pilot study to evaluate the consensus-based international MRI scoring system as decision criterion for targeted MRI-guided prostate biopsy. MATERIAL AND METHODS: After a multi-parametric 3-T MRI (T2-weighted imaging, diffusion-weighted imaging, and dynamic contrast-enhanced MRI) in 23 consecutive patients a total of 47 lesions were scored according to a 5-point scale for each MRI sequence. A total score of ≥ 10 points was considered to be suspicious for prostate cancer. All 47 lesions were histologically assessed after MRI-guided biopsy. RESULTS: At the cut-off score of 10 points, sensitivity, specificity, negative predictive value and positive predictive value of multi-parametric MRI were 94.1, 43.3, 92.9 and 48.5%, respectively. CONCLUSIONS: A standardised scoring of lesions on multi-parametric MRI is feasible. The cut-off value leads to excellent values for sensitivity and negative predictive value. The values for specificity and positive predictive value are modest. Lesions with a total score <10 points are very unlikely to be malignant.


Assuntos
Biópsia por Agulha/normas , Interpretação de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Neoplasias da Próstata/patologia , Cirurgia Assistida por Computador/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...