1.
J Chromatogr A ; 949(1-2): 79-82, 2002 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-11999760

RESUMO

A rapid and sensitive high-performance liquid chromatographic method has been developed for the determination of dexamethasone sodium phosphate (DSP), xylometazoline hydrochloride (XMC) and methyl p-hydroxybenzoate (MHB). An assay of the compounds has been performed on a HPLC system GBC 1210, at controlled room temperature, on a Nucleosil C8 column (250x3 mm, 5 microm). The mobile phase was acetonitrile-water (35:65, v/v), at a flow-rate of 1 ml min(-1). The parameters for validation such as linearity (r>0.9996), precision (RSD: 0.51-(1.93%), limit of detection and quantification (2.032 x 10(-4) and 4.063 x 10(-4) mg ml(-1) for DSP, 9.7 x 10(-5) and 1.953 x 10(-4) mg ml(-1) for XMC, 1.953 x 10(-4) and 3.096 x 10(-4) mg ml(-1) for MHB) have also been reported. The method was applied to the determination of DSP, XMC and MHB in nasal drops. The statistical parameters were found to be satisfactory, with recovery values ranging from 98.69 to 101.60% (RSD: 0.32-1.03%). The method is simple and accurate and therefore suitable for the simultaneous determination of these compounds in dosage form.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Dexametasona/análise , Imidazóis/análise , Parabenos/análise , Preparações Farmacêuticas/química , Administração Intranasal , Dexametasona/administração & dosagem , Imidazóis/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Pharm Biomed Anal ; 21(1): 15-22, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10701909

RESUMO

The analytical problem was to control the quality of imported antiasthmatic tablets containing ephedrine hydrochloride, theophylline, papaverine hydrochloride and hydroxyzine hydrochloride. The aim of the analytical method for the assay was to separate, identify and quantify all compounds, at the same time. A gradient capable RP-LC system was used, using a commercially packed Nucleosil C18 column connected to a dual channel variable, programmable wavelength detector. The analysis was performed in the gradient program of increasing concentration of acetonitrile in water. The influence of pH of the mobile phase was established. The proposed method is reliable, reproducible, easy to perform and satisfies the aim.


Assuntos
Cromatografia Líquida/métodos , Efedrina/análise , Antagonistas dos Receptores Histamínicos H1/análise , Hidroxizina/análise , Papaverina/análise , Teofilina/análise , Antagonistas dos Receptores Histamínicos H1/isolamento & purificação , Concentração de Íons de Hidrogênio , Controle de Qualidade , Reprodutibilidade dos Testes , Comprimidos/análise