1.
J Neurointerv Surg ; 11(4): 396-399, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30262655

RESUMO

PURPOSE: The Pipeline Embolization Device (PED) is a routine first-line treatment option for intracranial aneurysms (IAs). The Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield) is an updated version of the PED which has been modified to include a surface phosphorylcholine biocompatible polymer. Its early technical success and safety have been reported previously. Here, we assessed the long-term safety and efficacy of the Pipeline Shield for the treatment of IAs. MATERIALS AND METHODS: The Pipeline Flex Embolization Device with Shield Technology (PFLEX) study was a prospective, single-arm, multicenter study for the treatment of unruptured IAs using the Pipeline Shield. The primary endpoint was a major stroke in the territory supplied by the treated artery or neurologic death at 1-year post-procedure. Angiographic outcomes were also assessed by an independent radiology laboratory at 6 months and 1 year. RESULTS: Fifty patients (mean age, 53 years; 82% female) with 50 unruptured IAs were treated. Mean aneurysm diameter was 8.82±6.15 mm. Of the target aneurysms, 38/50 (76%) were small (<10 mm), 11/50 (22%) were large (≥10 and<25 mm), and 1/50 (2%) was giant (≥25 mm). Forty-seven (94%) were located in the internal carotid artery and three (6%) in the vertebral artery. At 1-year post-procedure, no major strokes or neurologic deaths were reported, and complete occlusion was achieved in 27/33 (81.8%). There were no instances of aneurysm recurrence or retreatment. CONCLUSIONS: Our 1-year follow-up concerning angiographic and safety outcomes corroborate previous evidence that the Pipeline Shield is a safe and effective treatment for IAs. TRIAL REGISTRATION NUMBER: NCT02390037.


Assuntos
Angiografia Cerebral/tendências , Embolização Terapêutica/instrumentação , Embolização Terapêutica/tendências , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Adulto , Idoso , Prótese Vascular/efeitos adversos , Prótese Vascular/tendências , Angiografia Cerebral/efeitos adversos , Embolização Terapêutica/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Retratamento/tendências , Fatores de Tempo , Resultado do Tratamento
2.
J Neurointerv Surg ; 9(8): 772-776, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28223428

RESUMO

BACKGROUND AND PURPOSE: The Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic biocompatible polymer. MATERIALS AND METHODS: The Pipeline Flex Embolization Device with Shield Technology (PFLEX) study is a prospective, single-arm, multicenter study for the treatment of unruptured IAs using Pipeline Shield. The primary study endpoints included the occurrence of major stroke in the territory supplied by the treated artery or neurologic death at 1 year post-procedure. Secondary endpoints included the rate of Pipeline Shield-related or procedure-related serious or non-serious adverse events. Analyses were conducted to evaluate early safety findings in the 30-day post-procedure period as well as technical procedural success outcomes. RESULTS: Fifty patients with 50 unruptured target IAs were enrolled. Mean aneurysm diameter was 8.82±6.15 mm. Thirty-eight aneurysms (76%) were small (<10 mm). Device deployment was technically successful with 98% of devices. Complete wall apposition was achieved immediately post-procedure in 48 cases (96%). No major strokes or neurologic deaths were reported in the 30-day post-procedure period. CONCLUSIONS: The results of this first experience with the new Pipeline Flex corroborate the early safety of the device. Mid-term and long-term follow-up examinations will provide data on safety outcomes at the 6-month and 1-year follow-up periods. CLINICAL TRIAL REGISTRATION: NCT02390037.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico , Aneurisma Intracraniano/terapia , Assistência Perioperatória/métodos , Stents , Adulto , Idoso , Embolização Terapêutica/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/tendências , Estudos Prospectivos , Resultado do Tratamento