Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
JACC Case Rep ; 14: 101823, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37152706

RESUMO

Newer self-expanding transcatheter pulmonary valves (TPVs) are approved for the treatment of severe pulmonary regurgitation in patients with large right ventricular outflow tracts. We present a patient with Tetralogy of Fallot whose right ventricular outflow tract was too large for self-expanding TPV, who was treated successfully with a self-expanding TPV in the right pulmonary artery. (Level of Difficulty: Advanced.).

2.
Expert Rev Cardiovasc Ther ; 21(5): 337-345, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37096558

RESUMO

INTRODUCTION: Ventricular septal defect is the most common congenital heart defect. Surgical repair has been standard therapy for symptomatic ventricular septal defects since the 1950s. Catheter-based device closure of ventricular septal defects emerged in the 1980s and has become a safe and effective alternative in select patients. AREAS COVERED: This review focuses on patient selection and procedural techniques for device closure of ventricular septal defects, including percutaneous and hybrid perventricular approaches. The available devices used for these procedures and outcomes of their use are reviewed. EXPERT OPINION: Percutaneous and perventricular device closure of ventricular septal defects is safe and effective in select patients. However, the majority of ventricular septal defects requiring closure continue to be managed with conventional surgery. Further development and investigation of transcatheter and hybrid surgical approaches for closing ventricular septal defects is required.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular , Dispositivo para Oclusão Septal , Humanos , Lactente , Procedimentos Cirúrgicos Cardíacos/métodos , Resultado do Tratamento , Ecocardiografia Transesofagiana , Desenho de Prótese , Comunicação Interventricular/cirurgia , Cateterismo Cardíaco
3.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36995404

RESUMO

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Sistema de Registros , Fatores de Tempo , Estudos Retrospectivos
4.
J Biomed Mater Res B Appl Biomater ; 111(4): 958-970, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36479954

RESUMO

Biodegradable shape memory polymers provide unique regenerative medicine approaches in minimally invasive surgeries. Once heated, thermally responsive shape memory polymer devices can be compressed, programmed to fit within a small profile, delivered in the cold programmed state, and expanded when heated to body temperature. We have previously developed a biodegradable shape memory elastomer (SME), poly(glycerol dodecanedioate) (PGD), with transition temperatures near 37°C exhibiting nonlinear elastic properties like numerous soft tissues. Using SMEs in the clinic requires disinfection and sterilization methods that conserve physiochemical, thermomechanical, and shape recovery properties. We evaluated disinfection protocols using 70% ethanol and UV254 nm for research applications and ethylene oxide (EtO) gas sterilization for clinical applications. Samples disinfected with ethanol for 0.5 and 1 min showed no changes in physiochemical material properties, but after 15 min showed slower recovery rates than controls (p < .05). EtO sterilization at 54.4°C decreased transition temperatures and shape recovery rate compared to EtO sterilization at 37.8°C (p < .01) and controls (p < .05). Aging samples for 9 months in a vacuum desiccator significantly reduced shape recovery, and the recovery rate in EtO sterilized samples compared to controls (p < .001). Cytotoxicity testing (ISO-10993.5C:2012) revealed media extractions from EtO sterilized samples, sterilized at 37.8°C, and high-density polyethylene negative control samples exhibit lower cytotoxicity (IC50) than Ethanol 1 min, UV 2 h, and EtO 54.4°C. Cell viability of NIH3T3 fibroblasts on sterilized surfaces was equivalent on EtO 37.7°C, EtO 54.4°C and Ethanol sterilized substrates. Finally, chromogenic bacterial endotoxin testing showed endotoxin levels were below the FDA prescribed levels for devices contacting blood and lymphatic tissues for ethanol 1 min, UV 120 min, EtO 37.7°C, EtO 54.4°C. These findings outline various disinfection and sterilization processes for research and pre-clinical application and provide a pathway for developing custom sterilization cycles for the translation of biomedical devices utilizing PGD shape memory polymers.


Assuntos
Elastômeros , Glicerol , Animais , Camundongos , Elastômeros/farmacologia , Glicerol/farmacologia , Células NIH 3T3 , Esterilização/métodos , Desinfecção , Etanol , Óxido de Etileno/farmacologia , Óxido de Etileno/química
5.
Biomaterials ; 293: 121950, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36580715

RESUMO

Shape memory biodegradable elastomers are an emergent class of biomaterials well-suited for percutaneous cardiovascular repair requiring nonlinear elastic materials with facile handling. We have previously developed a chemically crosslinked shape memory elastomer, poly (glycerol dodecanedioate) (PGD), exhibiting tunable transition temperatures around body temperature (34-38 °C), exhibiting nonlinear elastic properties approximating cardiac tissues, and favorable degradation rates in vitro. Degree of tissue coverage, degradation and consequent changes in polymer thermomechanical properties, and inflammatory response in preclinical animal models are unknown material attributes required for translating this material into cardiovascular devices. This study investigates changes in the polymer structure, tissue coverage, endothelialization, and inflammation of percutaneously implanted PGD patches (20 mm × 9 mm x 0.5 mm) into the branch pulmonary arteries of Yorkshire pigs for three months. After three months in vivo, 5/8 samples exhibited (100%) tissue coverage, 2/8 samples exhibited 85-95% tissue coverage, and 1/8 samples exhibited limited (<20%) tissue coverage with mild-moderate inflammation. PGD explants showed a (60-70%) volume loss and (25-30%) mass loss, and a reduction in polymer crosslinks. Lumenal and mural surfaces and the cross-section of the explant demonstrated evidence of degradation. This study validates PGD as an appropriate cardiovascular engineering material due to its propensity for rapid tissue coverage and uneventful inflammatory response in a preclinical animal model, establishing a precedent for consideration in cardiovascular repair applications.


Assuntos
Elastômeros , Glicerol , Animais , Suínos , Elastômeros/química , Glicerol/química , Artéria Pulmonar , Materiais Biocompatíveis/química , Polímeros/química , Inflamação , Engenharia Tecidual
6.
Cardiol Young ; 33(4): 633-636, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35903024

RESUMO

In infracardiac, infradiaphragmatic total anomalous pulmonary venous connection, all four pulmonary veins connect to a descending vertical vein that usually drains to the portal vein or one of its tributaries. Obstruction is common, and definitive treatment is surgical repair. We present a case of late-diagnosed infradiaphragmatic total anomalous pulmonary venous connection in a premature neonate who was too high risk for surgery and underwent palliative stenting of the venous duct. We demonstrate the feasibility of a transhepatic approach when umbilical access is no longer available.


Assuntos
Veias Pulmonares , Síndrome de Cimitarra , Recém-Nascido , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/anormalidades , Síndrome de Cimitarra/cirurgia , Veia Porta , Stents
7.
Bioact Mater ; 14: 262-271, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35310360

RESUMO

Biodegradable stents have tremendous theoretical potential as an alternative to bare metal stents and drug-eluting stents for the treatment of obstructive coronary artery disease. Any bioresorbable or biodegradable scaffold material needs to possess optimal mechanical properties and uniform degradation behavior that avoids local and systemic toxicity. Recently, molybdenum (Mo) has been investigated as a potential novel biodegradable material for this purpose. With its proven moderate degradation rate and excellent mechanical properties, Mo may represent an ideal source material for clinical cardiac and vascular applications. The present study was performed to evaluate the mechanical performance of metallic Mo in vitro and the biodegradation properties in vivo. The results demonstrated favorable mechanical behavior and a uniform degradation profile as desired for a new generation ultra-thin degradable endovascular stent material. Moreover, Mo implants in mouse arteries avoided the typical cellular response that contributes to restenosis. There was minimal neointimal hyperplasia over 6 months, an absence of excessive smooth muscle cell (SMC) proliferation or inflammation near the implant, and avoidance of significant harm to regenerating endothelial cells (EC). Qualitative inspection of kidney sections showed a potentially pathological remodeling of kidney Bowman's capsule and glomeruli, indicative of impaired filtering function and development of kidney disease, although quantifications of these morphological changes were not statistically significant. Together, the results suggest that the products of Mo corrosion may exert beneficial or inert effects on the activities of inflammatory and arterial cells, while exerting potentially toxic effects in the kidneys that warrant further investigation.

8.
JACC Case Rep ; 3(5): 712-714, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34317611

RESUMO

In select patients, transcatheter pulmonary valve replacement through a percutaneous approach can be challenging because of complicated anatomy or small patient size. In these patients, especially those weighing <20 kg, hybrid perventricular valve delivery may provide a preferred alternative approach. (Level of Difficulty: Intermediate.).

9.
J Mech Behav Biomed Mater ; 110: 103965, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32957256

RESUMO

Structural repair of soft tissue for regenerative therapies can be advanced by developing biocompatible and bioresorbable materials with mechanical properties similar to the tissue targeted for therapy. Developing new materials modeling soft tissue mechanics can mitigate many limitations of material based therapies, specifically concerning the mechanical stress and deformation the material imposes on surrounding tissue structures. However, many elastomeric materials used in soft tissue repair lack the ability to be delivered through minimally invasive surgical (MIS) or transcatheter routes and require open surgical approaches for placement and application. We have developed a biocompatible and fully biodegradable shape memory elastomer, poly-(glycerol dodecanedioate) (PGD), which fulfills the requirements for hyperelasticity and exhibits shape memory behavior to serve as a novel substrate material for regenerative therapy in minimally invasive clinical procedures. Our previous work demonstrated control over the tangent modulus at 12.5% compressive strain between 1 and 3 MPa by increasing the crosslinking density in the polymer. In order to improve control over a broader range of mechanical properties, nonlinear behavior, and toughness, we 1) varied PGD physical crosslink density, 2) incorporated sheets of porcine small intestinal submucosa (SIS, Cook Biotech, Inc.) with varying thickness, and 3) mixed lyophilized SIS particulates into PGD at different weight percentages. Tensile testing (ASTM D412a) revealed PGD containing SIS sheets of were stiffer than controls (p < 0.01). Incorporating lyophilized SIS particulates into PGD increased the strain to failure (p < 0.001) compared to PGD controls. Test specimens with 1 ply sheets had greater tear strength (ASTM D624c) compared to PGD tear specimens prepared control specimens (p < 0.001). However, incorporating SIS particulates decreased tear strength of PGD-SIS 0.5 wt% particulate composites (p < 0.01) compared to PGD controls. Incorporating 2 ply and 4 ply sheets and 0.5 wt% particulates into PGD decreased the fixity and recovery of composite materials compared to controls (p < 0.01). Nonlinear modeling of stress strain curves under uniaxial tension demonstrated tunability of PGD-SIS composite materials to model various nonlinear soft tissues. These findings support the use of shape memory PGD-SIS composite materials towards the design of implantable devices for a variety of soft tissue regeneration applications by minimally invasive surgery.


Assuntos
Elastômeros , Engenharia Tecidual , Animais , Materiais Biocompatíveis , Glicerol , Mucosa Intestinal , Polímeros , Estresse Mecânico , Suínos
10.
Mater Sci Eng C Mater Biol Appl ; 111: 110826, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32279804

RESUMO

Biodegradable arterial implants based on zinc have been found to suppress neointimal hyperplasia, suggesting that biodegradable materials containing zinc may be used to construct vascular implants with a reduced rate of restenosis. However, the molecular mechanism has remained unclear. In this report, we show that zinc-containing materials can be used to prevent neointimal formation when implanted into the rat aorta. Indeed, neointimal cells were significantly more TUNEL positive and alpha-actin negative at the interface of biodegradable zinc vs. biostable platinum implants, in association with greater caspase-3 activity. Although zinc stimulated extensive neointimal smooth muscle cell (SMC) death, macrophage and proinflammatory markers CD68 and iNOS were not increased in neointimal tissue relative to biostable platinum control implants. Using arterial explants, ionic zinc was confirmed to promote SMC apoptosis by activating the caspase apoptotic signaling pathway. These observations suggest that zinc-containing materials can be used to construct vascular implants such as stents with reduced neointimal hyperplasia.


Assuntos
Implantes Absorvíveis , Músculo Liso Vascular/patologia , Miócitos de Músculo Liso/patologia , Zinco/farmacologia , Animais , Antígenos CD/metabolismo , Antígenos de Diferenciação Mielomonocítica/metabolismo , Caspases/metabolismo , Ativação Enzimática , Hiperplasia , Miócitos de Músculo Liso/efeitos dos fármacos , Neointima/patologia , Óxido Nítrico Sintase Tipo II/metabolismo , Ratos
11.
PLoS One ; 15(2): e0229112, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32084184

RESUMO

Development of biodegradable shape memory elastomers (SMEs) is driven by the growing need for materials to address soft tissue pathology using a minimally invasive surgical approach. Composition, chain length and crosslinking of biocompatible polymers like PCL and PLA have been investigated to control mechanical properties, shape recovery and degradation rates. Depending on the primary mechanism of degradation, many of these polymers become considerably stiffer or softer resulting in mechanical properties that are inappropriate to support the regeneration of surrounding soft tissues. Additionally, concerns regarding degradation byproducts or residual organic solvents during synthesis accelerated interest in development of materials from bioavailable monomers. We previously developed a biodegradable SME, poly(glycerol dodecanoate) (PGD), using biologically relevant metabolites and controlled synthesis conditions to tune mechanical properties for soft tissue repair. In this study, we investigate the influence of crosslinking density on the mechanical and thermal properties of PGD during in vitro and in vivo degradation. Results suggest polymer degradation in vivo is predominantly driven by surface erosion, with no significant effects of initial crosslinking density on degradation time under the conditions investigated. Importantly, mechanical integrity is maintained during degradation. Additionally, shifts in melt transitions on thermograms indicate a potential shift in shape memory transition temperatures as the polymers degrade. These findings support the use of PGD for soft tissue repair and warrant further investigation towards tuning the molecular and macromolecular properties of the polymer to tailor degradation rates for specific clinical applications.


Assuntos
Materiais Biocompatíveis/química , Elastômeros/química , Poliésteres/química , Polímeros/química , Alicerces Teciduais/química , Calorimetria , Engenharia Tecidual
12.
Am J Cardiol ; 121(2): 262-268, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29153244

RESUMO

We sought to describe the acute results and short- to medium-term durability of transcatheter tricuspid valve-in-valve (TVIV) implantation within surgical bioprostheses among patients with Ebstein anomaly (EA). Cases were identified from a voluntary, multicenter, international registry of 29 institutions that perform TVIV. Demographic, clinical, procedural, and follow-up data were analyzed. Eighty-one patients with EA underwent TVIV from 2008 to 2016. Thirty-four patients (42%) were New York Heart Association (NYHA) class 3/4 at time of TVIV. The most common indication for TVIV was the presence of moderate or severe tricuspid regurgitation (40%). Most patients received a Melody valve (64%). TVIV was ultimately successful in all patients, and there was no procedural mortality. Four patients (5%) developed acute valve thrombosis, 4 patients (5%) developed endocarditis, and 9 patients (11%) developed valve dysfunction not related to thrombosis or endocarditis. Eight patients (10%) underwent reintervention (2 transcatheter, 6 surgical) due to thrombosis (3), endocarditis (2), other valve dysfunction (2), and patient-prosthesis mismatch without valve dysfunction (1). Among 69 patients who were alive without reintervention at latest follow-up, 96% of those with NYHA status reported were class 1/2, a significant improvement from baseline (62% NYHA class 1/2, p <0.001). In conclusion, transcatheter TVIV offers a low-risk, minimally invasive alternative to surgical tricuspid valve re-replacement in patients with EA and a failing tricuspid valve bioprosthesis.


Assuntos
Anomalia de Ebstein/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Bioprótese , Cateterismo Cardíaco/métodos , Anomalia de Ebstein/complicações , Endocardite/epidemiologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Reoperação , Trombose/epidemiologia , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Adulto Jovem
13.
Circ Cardiovasc Interv ; 10(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28851718

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) is an established therapy for dysfunctional right ventricular (RV) outflow tract conduits. TPVR in patients with congenitally corrected transposition of the great arteries, subpulmonary left ventricle, and left ventricular outflow tract (LVOT) conduit dysfunction has not been studied. Unique anatomic and physiological aspects of this population may contribute to distinct risks and outcomes. METHODS AND RESULTS: Across 10 US centers, 27 patients with a dysfunctional LVOT conduit were evaluated in the catheterization laboratory between December 2008 and August 2015 with the intent to perform TPVR. TPVR was successful in 23 patients (85%). Five serious adverse events occurred in 4 cases (15%), including pulmonary hemorrhage, hypotension requiring vasoactive support, conduit disruption requiring covered stent (n=2), and acute RV dysfunction with flash pulmonary edema. After TPVR, the LVOT peak systolic ejection gradient decreased from median of 35 to 17 mm Hg (P<0.001); pulmonary insufficiency was trivial/none in all but 1 patient, where it was mild. Worsening of systemic RV dysfunction or tricuspid regurgitation was seen in 12 patients (57%) and was associated with a significantly lower post-TPVR LVOT peak systolic ejection gradient (median 17 versus 21 mm Hg; P=0.02) and higher post-TPVR RV sphericity index (median 0.88 versus 0.52; P=0.004). Post-TPVR, there were 2 late deaths because of RV failure and 1 cardiac transplantation because of progressive RV dysfunction and tricuspid regurgitation. CONCLUSIONS: TPVR in dysfunctional LVOT conduits is feasible but associated with an important rate of TPV nonimplantation and procedural serious adverse events. Worsening systemic RV function and tricuspid regurgitation may develop after LVOT TPVR.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Ventrículos do Coração/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Transposição dos Grandes Vasos/cirurgia , Função Ventricular Esquerda , Adolescente , Adulto , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Criança , Transposição das Grandes Artérias Corrigida Congenitamente , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/mortalidade , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/mortalidade , Transposição dos Grandes Vasos/fisiopatologia , Resultado do Tratamento , Estados Unidos , Função Ventricular Direita , Adulto Jovem
14.
Circ Cardiovasc Interv ; 10(6)2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28600328

RESUMO

BACKGROUND: Follow-up of transcatheter pulmonary valve replacement (TPVR) with the Melody valve has demonstrated good short-term and long-term outcomes, but there are no published studies focused on valve performance in the Contegra bovine jugular vein conduit. METHODS AND RESULTS: This is a retrospective, multicenter study of the short- and intermediate-term outcomes of Melody TPVR within the Contegra conduit in the right ventricle to pulmonary artery position. Data from 13 centers were included in the analysis. During the study period, 136 patients underwent 139 catheterizations for attempted Melody TPVR with a median follow-up of 3 years (1 day to 9.1 years). Of the 136 patients, 117 underwent successful Melody TPVR. Two patients underwent a second Melody TPVR. The majority of patients underwent placement of ≥1 stents before transcatheter pulmonary valve implantation. There was a significant reduction in peak conduit pressure gradient acutely after transcatheter pulmonary valve implantation (39 versus 10 mm Hg; P<0.001). At most recent follow-up, the maximum pulmonary valve gradient by echocardiogram remained significantly reduced relative to prevalve implant measurements (65.9 versus 27.3 mm Hg; P<0.001). The incidence of Melody transcatheter pulmonary valve stent fracture (3.4%) and infectious endocarditis (4.3%) were both low. Serious adverse events occurred in 3 patients. CONCLUSIONS: Melody TPVR in Contegra conduits is safe and effective and can be performed in a wide range of conduit sizes with preserved valve function and low incidence of stent fracture and endocarditis.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo Cardíaco/instrumentação , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Ventrículos do Coração/cirurgia , Veias Jugulares/transplante , Artéria Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Animais , Implante de Prótese Vascular/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Bovinos , Criança , Pré-Escolar , Europa (Continente) , Feminino , Cardiopatias Congênitas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ventrículos do Coração/anormalidades , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Xenoenxertos , Humanos , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Artéria Pulmonar/anormalidades , Artéria Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
15.
ASAIO J ; 63(6): 766-773, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28394815

RESUMO

Prolonged normothermic ex vivo heart perfusion could transform cardiac transplantation. To help identify perfusate components that might enable long-term perfusion, we evaluated the effects of cross-circulated whole blood and cross-circulated plasma from a live paracorporeal animal on donor porcine hearts preserved via normothermic ex vivo heart perfusion. Standard perfusion (SP; n = 40) utilized red blood cell/plasma perfusate and Langendorff technique for a goal of 12 hours. Cross-circulation groups used a similar circuit with the addition of cross-circulated venous whole blood (XC-blood; n = 6) or cross-circulated filtered plasma (XC-plasma; n = 7) between a live paracorporeal pig under anesthesia and the perfusate reservoir. Data included oxygen metabolism, vascular resistance, lactate production, left ventricular function, myocardial electrical impedance, and histopathologic injury score. All cross-circulation hearts were successfully perfused for 12 hours, compared with 22 of 40 SP hearts (55%; p = 0.002). Both cross-circulation groups demonstrated higher oxygen consumption and vascular resistance than standard hearts from hours 3-12. No significant differences were seen between XC-blood and XC-plasma hearts in any variable, including left ventricular dP/dT after 12 hours (1478 ± 700 mm Hg/s vs. 872 ± 500; p = 0.17). We conclude that cross circulation of whole blood or plasma from a live animal improves preservation of function of perfused hearts, and cross-circulated plasma performs similarly to cross-circulated whole blood.


Assuntos
Circulação Cruzada , Transplante de Coração , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Plasma , Suínos , Resistência Vascular
16.
J Biomed Mater Res A ; 105(6): 1618-1623, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27935209

RESUMO

A major challenge in the repair and regeneration of soft tissue damage occurring as a result of aging, injury, or disease is recapitulating the biomechanical properties of the native tissue. Ideally, a candidate biomaterial for soft tissue engineering applications should be biocompatible, nonlinearly elastic to match soft tissue mechanical behavior, biodegradable to enable tissue remodeling, and tailorable to achieve a range of nonlinear elastic mechanical properties to match specific soft tissues. In addition, for cardiac and other applications, the biomaterial should have shape memory characteristics to facilitate minimally invasive and/or catheter-based delivery. Poly(glycerol dodecanoate) (PGD) is a shape memory material that has nonlinear elastic properties at body temperature and elastic-plastic behavior at room temperature. In this study, we investigated the effects of curing conditions on the nonlinear elastic, shape memory, and biocompatibility properties of PGD. Increased curing and crosslinking resulted in an increase in both the initial stiffness and the nonlinear strain stiffening behavior of PGD. After shape fixation at 60% strain, 100% shape recovery was achieved within 1 min at body temperature for all conditions tested. Polymer curing had no adverse effects on the cellular biocompatibility or non-hemolytic characteristics of PGD, indicating the potential suitability of these formulations for blood-contacting device applications. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1618-1623, 2017.


Assuntos
Materiais Biocompatíveis/química , Poliésteres/química , Animais , Proliferação de Células , Fibroblastos/citologia , Teste de Materiais , Coelhos , Engenharia Tecidual , Alicerces Teciduais/química , Temperatura de Transição
17.
Catheter Cardiovasc Interv ; 89(2): 298-305, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27465501

RESUMO

BACKGROUND: The most common reason for reintervention after a Björk modification of the Fontan procedure, in which the right ventricle (RV) is incorporated into the pulmonary circulation by connecting the right atrial (RA) appendage to the RV directly or with an extra-anatomic graft, is obstruction or regurgitation of the RA-RV connection. Transcatheter implantation of a valved stent is an appealing option for the treatment of RA-RV conduit dysfunction in these patients. In the present study, we assessed early and intermediate results after transcatheter valve implantation within an obstructed or regurgitant RA-RV modified Fontan pathway. METHODS: Through a retrospective multicenter registry, we collected data from 16 patients with a modified Fontan circulation who were treated with percutaneous Melody or Sapien valve implantation for dysfunction of an extra-anatomic RA-RV conduit or valve. RESULTS: All patients had successful and uncomplicated implantation of a Melody (n = 15) or Sapien 3 (n = 1) valve with hemodynamic and, in most cases, clinical improvement. During a median follow-up of 3.3 years, 3 patients died of cardiovascular causes unrelated to the procedure or the valve, and no major valve dysfunction was observed. CONCLUSION: Percutaneous transcatheter valve deployment to treat a dysfunctional RA-RV connection after a Björk modification of the Fontan procedure is a viable alternative to surgery, with low procedural risk, and appears to offer good early and intermediate results.© 2016 Wiley Periodicals, Inc.


Assuntos
Implante de Prótese Vascular , Cateterismo Cardíaco/métodos , Técnica de Fontan/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Adulto , Bioprótese , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Canadá , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Europa (Continente) , Feminino , Técnica de Fontan/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
18.
ASAIO J ; 62(4): 470-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27164040

RESUMO

Although total body perfusion with extracorporeal life support (ECLS) can be maintained for weeks, individual organ perfusion beyond 12 hours has yet to be achieved clinically. Normothermic ex situ heart perfusion (ESHP) offers the potential for prolonged cardiac preservation. We developed an ESHP system to study the effect of perfusate variables on organ preservation, with the ultimate goal of extending organ perfusion for ≥24 hours. Forty porcine hearts were perfused for a target of 12 hours. Hearts that maintained electromechanical activity and had a <3× increase in vascular resistance were considered successful preservations. Perfusion variables, metabolic byproducts, and histopathology were monitored and sampled to identify factors associated with preservation failure. Twenty-two of 40 hearts were successfully preserved at 12 hours. Successful 12 hour experiments demonstrated lower potassium (4.3 ± 0.8 vs. 5.0 ± 1.2 mmol/L; p = 0.018) and lactate (3.5 ± 2.8 vs. 4.5 ± 2.9 mmol/L; p = 0.139) levels, and histopathology revealed less tissue damage (p = 0.003) and less weight gain (p = 0.072). Results of these early experiments suggest prolonged ESHP is feasible, and that elevated lactate and potassium levels are associated with organ failure. Further studies are necessary to identify the ideal perfusate for normothermic ESHP.


Assuntos
Transplante de Coração , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Suínos , Fatores de Tempo
19.
Catheter Cardiovasc Interv ; 88(7): 1113-1117, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27184689

RESUMO

A 28-year-old male with single ventricular heart disease status post Fontan palliation and subsequent placement of left ventricle to ascending aorta (LV-AAo) valved conduit developed ascites and edema. Diagnostic catheterization revealed elevated ventricular end diastolic pressures (EDP) secondary to severe LV-AAo conduit regurgitation. Given the unique anatomy, surgical access via the right axillary artery provided optimal route for transcatheter valve implantation within the conduit. The procedure resulted in significant hemodynamic improvement with no complications. © 2016 Wiley Periodicals, Inc.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo Cardíaco/instrumentação , Procedimentos Endovasculares/instrumentação , Técnica de Fontan/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Valva Pulmonar/transplante , Função Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo/cirurgia , Adulto , Aortografia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Cateterismo Cardíaco/métodos , Procedimentos Endovasculares/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Masculino , Cuidados Paliativos , Rotulagem de Produtos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Reoperação , Fatores de Risco , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
20.
Circulation ; 133(16): 1582-93, 2016 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-26994123

RESUMO

BACKGROUND: Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. METHODS AND RESULTS: An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II (P<0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. CONCLUSIONS: TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.


Assuntos
Bioprótese/tendências , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Internacionalidade , Falha de Prótese/tendências , Insuficiência da Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioprótese/efeitos adversos , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Tempo de Internação/tendências , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...