Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Tech Coloproctol ; 23(2): 101-115, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30631977

RESUMO

Pelvic floor rehabilitation is frequently recommended for defecation disorders, in both constipation and fecal incontinence. However, the lack of patient selection, together with the variety of rehabilitation methods and protocols, often jeopardize the results of this approach, causing difficulty in evaluating outcomes and addressing proper management, and above all, in obtaining scientific evidence for the efficacy of these methods for specific indications. The authors represent different gastroenterological and surgical scientific societies in Italy, and their aim was to identify the indications and agree on treatment protocols for pelvic floor rehabilitation of patients with defecation disorders. This was achieved by means of a modified Delphi method, utilizing a working team (10 members) which developed the statements and a consensus group (15 members, different from the previous ones) which voted twice also suggesting modifications of the statements.


Assuntos
Constipação Intestinal/reabilitação , Incontinência Fecal/reabilitação , Gastroenterologia/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Defecação , Técnica Delphi , Humanos , Itália , Diafragma da Pelve
2.
Int J Colorectal Dis ; 29(1): 57-64, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23975054

RESUMO

BACKGROUND AND AIMS: Subsite-specific incidence rates of colorectal cancer (CRC) and adenomas may vary considerably by race, sex and age as well as due to different screening strategies. We assessed variations in the anatomical distribution of adenomas according to age and sex in an average-risk screening cohort testing positive at immunological faecal occult blood test (i-FOBT) in northern Italy. METHODS: Data from 2,281 consecutive asymptomatic i-FOBT-positive subjects ageing 50-70 years undergone colonoscopy were reviewed. Size, number, macroscopic and histological features of all adenomas found as well as their proximal or distal location in relation to the splenic flexure were examined. Odds ratios (OR) of proximal neoplasms, according to the presence of distal neoplasms and other selected covariates were assessed by multiple logistic regression analysis. RESULTS: A total of 2,599 neoplasms were found in 1,396 patients. Of these, 116 (5 %) were colorectal cancers, diagnosed in 106 patients. Out of 2,483 adenomas found, 1,564 (63 %) were sessile, 795 (32 %) were peduncolated and 124 (5 %) were flat-type; 54 % of all adenomas were tubular, 36 % were tubulovillous or villous, and 10 % were serrated adenomas. The majority of neoplasms (66 %) were located in the distal colon. Tumour subsite distribution was consistent in both sexes, whereas significant proximal migration of neoplasms occurred in the older age cohort. Indeed, the rate of proximal neoplasms in patients aged ≥60 years was 37 % as compared with 29 % in those ageing 50-59 years. Male gender (OR 1.84), age of 60 years or older (OR 1.44), having a family history of colorectal neoplasms (OR 1.47) and presence of at least 1 distal advanced adenoma (OR 1.63) were all significant predictors of advanced proximal neoplasms. CONCLUSIONS: A left to right shift of colorectal adenomas with increasing age is evident in northern Italian asymptomatic i-FOBT-positive population. Advanced proximal neoplasms are not uncommon in subjects with or without distal adenomas, especially after 60 years of age. This should be carefully considered when implementing public screening strategies for CRC since the use of flexible sigmoidoscopy as a screening tool, particularly in older age groups, appears to be less effective.


Assuntos
Adenoma/patologia , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer/métodos , Testes Hematológicos/métodos , Sangue Oculto , Caracteres Sexuais , Adenoma/sangue , Adenoma/diagnóstico , Adenoma/epidemiologia , Fatores Etários , Idoso , Estudos de Coortes , Colonoscopia , Neoplasias Colorretais/sangue , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco
3.
Endoscopy ; 45(1): 27-34, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23254404

RESUMO

BACKGROUND AND STUDY AIMS: Colorectal cancer (CRC) screening aims to reduce mortality by detecting cancers at an early stage and removing adenomatous polyps at an acceptable cost. The aim of the current study were to assess the outcomes and costs of the first two biennial rounds of a population-based CRC screening program using the immunochemical fecal occult blood test (i-FOBT) in a northern Italian province. METHODS: All residents aged 50 - 69 years were invited to take part in a biennial screening program using a 1-day i-FOBT, followed by colonoscopy in positive individuals. The i-FOBT uptake, compliance to colonoscopy, detection rate for cancer or advanced adenomas according to age and sex, and direct cost analysis were carried out separately for the 1st and 2nd rounds of screening. RESULTS: In 78 083 (1st round) and 81 619 (2nd round) individuals who were invited to screening, the participation rates were 49.7 % and 54.4 % and i-FOBT positivity rates were 6.2 % and 5.8 %, respectively. Detection rates for cancer and advanced adenomas were lower in the 2nd screening compared with the 1st one (1.6‰ vs. 2.5‰ for cancers and 15.8‰ vs. 17.9‰ for advanced adenomas, respectively), whereas positive predictive values for cancer and advanced adenoma were similar in both rounds. In 165 adenocarcinomas detected, 52 % were Dukes' stage A and 21 % were stage B. All cost indicators were slightly higher in the 1st round of screening compared with the 2nd. The direct cost per cancer or advanced adenoma detection was similar in the two rounds (€â€Š1252 and €â€Š1260, respectively). CONCLUSIONS: Compliance and diagnostic yield of i-FOBT screening were satisfactory. Most detected cancers were at a very early stage. Program costs were reasonable and did not increase with repeat screening. Screening could contribute to decreasing the cost of CRC care by improving the stage at diagnosis.


Assuntos
Neoplasias Colorretais/diagnóstico , Programas de Rastreamento/economia , Sangue Oculto , Avaliação de Processos e Resultados em Cuidados de Saúde , Idoso , Neoplasias Colorretais/economia , Neoplasias Colorretais/epidemiologia , Custos e Análise de Custo , Detecção Precoce de Câncer , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade
4.
Endoscopy ; 40(9): 759-63, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18702032

RESUMO

BACKGROUND AND STUDY AIMS: In a previous study, a new flexible bipolar hybrid cryotherm probe was applied with success to the pancreas of a living pig. Here we evaluated feasibility, efficacy, and safety of its application to the porcine liver and spleen. MATERIAL AND METHODS: Ten applications to the liver and nine to the spleen were performed in 19 pigs. Power input (16-18 W) and simultaneous cooling with CO(2) (standardized pressure: 675 psi) as the cryogenic agent were investigated. Application time varied from 120 seconds to 900 seconds. The ablation area was measured by endoscopic ultrasound (EUS) after ablation (T0), and before euthanasia (T1). Gross pathology (T2) and histology after necropsy represented the gold standard. The interval from treatment to euthanasia was 1 or 2 weeks. RESULTS: For both organs the correlation between EUS and gross pathology was good (correlation coefficient R(liver) = 0.71; R(spleen) = 0.73). EUS tended to overestimate the area of the ablated zone. EUS observed a time-dependent ablation area: we demonstrated a positive trend of lesion size (T1) over time in liver tissue (R = 0.51 (P = 0.1)). In the spleen we found a clear correlation of lesion area T2 and application time (R = 0.75, P = 0.01). There were no complications. CONCLUSIONS: Selective EUS-guided transgastric cryotherm ablation of the liver and spleen in a pig model is feasible and safe. The new bipolar probe creates a time-dependent ablation area without any complications, and opens a field of new potential indications of RF-ablative therapies.


Assuntos
Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Endoscopia/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Baço/diagnóstico por imagem , Baço/cirurgia , Animais , Desenho de Equipamento , Estudos de Viabilidade , Fígado/patologia , Modelos Animais , Baço/patologia , Suínos , Ultrassonografia
5.
Endoscopy ; 40(4): 321-6, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18389449

RESUMO

BACKGROUND AND STUDY AIMS: Open, laparoscopic, or percutaneous radiofrequency (RF) ablation of the pancreas is still dangerous, whereas endoscopic ultrasound (EUS)-guided ablation might reduce risk because it is less invasive and provides real-time monitoring. We aimed to demonstrate the feasibility of transluminal RF ablation and to evaluate the efficacy and safety of a new flexible bipolar ablation probe combining RF and cryotechnology. METHODS: 14 ablations were performed in 14 pigs. Energy input (16 W) and simultaneous cryogenic cooling with carbon dioxide (650 psi) were standardized. Application time range was 120 - 900 seconds. Ablation area was measured by EUS immediately after ablation (area T0), and before euthanasia (area T1). Macroscopic findings (area T2) and histological findings after necropsy served as gold standard. The interval from application to euthanasia was either 1 or 2 weeks. RESULTS: The correlation between EUS findings (area T1) and macroscopic appearance (area T2) was good ( R = 0.89). The correlation between the T2 ablation area and the application time showed a fitted ratio of 2.3 ( P < 0.0001) with a 1-week interval and 0.2 ( P = 0.01) with a 2-week interval. No pig died because of the procedure. Two pigs showed histochemical pancreatitis, which was clinically overt in one. Necropsy additionally revealed one burn to the gastric wall and four gut adhesions. CONCLUSIONS: Selective transluminal RF ablation of the pancreas under EUS control in a living pig model is feasible. The new flexible bipolar probe creates an ablation area with extent related to the duration of application, and with fewer complications than conventional RF ablation techniques.


Assuntos
Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Animais , Projetos Piloto , Complicações Pós-Operatórias , Análise de Regressão , Estatísticas não Paramétricas , Suínos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...