1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38582974

RESUMO

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Assuntos
Cardiomiopatias , Ablação por Cateter , Criocirurgia , Taquicardia Ventricular , Idoso , Humanos , Pessoa de Meia-Idade , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/complicações , Criocirurgia/efeitos adversos , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Temperatura , Resultado do Tratamento
2.
J Am Heart Assoc ; 13(8): e032033, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38591264

RESUMO

BACKGROUND: Chronic total coronary occlusions (CTO) substantially increase the risk for sudden cardiac death. Among patients with chronic ischemic heart disease at risk for sudden cardiac death, an implantable cardioverter defibrillator (ICD) is the favored therapy for primary prevention of sudden cardiac death. This study sought to investigate the impact of CTOs on the risk for appropriate ICD shocks and mortality within a nationwide prospective cohort. METHODS AND RESULTS: This is a subanalysis of the nationwide Dutch-Outcome in ICD Therapy (DO-IT) registry of primary prevention ICD recipients in The Netherlands between September 2014 and June 2016 (n=1442). We identified patients with chronic ischemic heart disease (n=663) and assessed available coronary angiograms for CTO presence (n=415). Patients with revascularized CTOs were excluded (n=79). The primary end point was the composite of all-cause mortality and appropriate ICD shocks. Clinical follow-up was conducted for at least 2 years. A total of 336 patients were included, with an average age of 67±9 years, and 20.5% was female (n=69). An unrevascularized CTO was identified in 110 patients (32.7%). During a median follow-up period of 27 months (interquartile range, 24-32), the primary end point occurred in 21.1% of patients with CTO (n=23) compared with 11.9% in patients without CTO (n=27; P=0.034). Corrected for baseline characteristics including left ventricular ejection fraction, and the presence of a CTO was an independent predictor for the primary end point (hazard ratio, 1.82 [95% CI, 1.03-3.22]; P=0.038). CONCLUSIONS: Within this nationwide prospective registry of primary prevention ICD recipients, the presence of an unrevascularized CTO was an independent predictor for the composite outcome of all-cause mortality and appropriate ICD shocks.


Assuntos
Oclusão Coronária , Desfibriladores Implantáveis , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Arritmias Cardíacas , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Incidência , Função Ventricular Esquerda , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Sistema de Registros , Fatores de Risco
4.
Heart Rhythm ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

6.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38291925

RESUMO

A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Médicos , Acidente Vascular Cerebral , Tromboembolia , Adulto , Humanos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Oclusão do Apêndice Atrial Esquerdo , Consenso , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Anticoagulantes/efeitos adversos , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Vitamina K , Apêndice Atrial/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047465

RESUMO

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Assuntos
Desfibriladores Implantáveis , Humanos , Qualidade de Vida , Estudos Prospectivos , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente
10.
J Clin Med ; 12(20)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37892626

RESUMO

Atrial fibrillation (AF) is the most common arrhythmia in adults worldwide and represents an important burden for patients, physicians, and healthcare systems. AF is associated with substantial mortality and morbidity, due to the disease itself and its specific complications, such as the increased risk of stroke and thromboembolic events associated with AF. The temporal relation between AF episodes and stroke is nonetheless incompletely understood. The factors associated with an increased thromboembolic risk remain unclear, as well as the stroke risk stratification. Therefore, in this review, we intend to expose the mechanisms and physiopathology leading to intracardiac thrombus formation and stroke in AF patients, together with the evidence supporting the causal hypothesis. We also expose the risk factors associated with increased risk of stroke, the current different risk stratification tools as well as future prospects for improving this risk stratification.

11.
J Arrhythm ; 39(5): 776-783, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799786

RESUMO

Background: The tissue response viewer (TRV) is a novel marker for ablation lesion quality that aims to classify lesions into transmural or nontransmural lesions (high or low dielectric response, HDR or LDR) using dielectric-based tissue assessment. The objective of this study was to gain insight in the TRV by relating its outcomes to conventional ablation parameters. Methods: Patients that had repeat ablation for atrial fibrillation with a dielectric imaging-based mapping system were enrolled. All ablation data were downloaded from the mapping system and analyzed to explore associations between TRV outcomes and other ablation parameters. Results: The cohort included 24 patients, in which 58 pulmonary veins and 8 superior vena cavas were targeted. A total of 388 energy applications were applied, resulting in 639 ablation points. The system classified 36% of ablation points as HDR and 44% as LDR. The system did not provide a dielectric response in 20%. The system's ability to provide a dielectric response was related to longer ablation duration and absence of dragging ablation. HDR (versus LDR) was multivariably associated with longer energy applications, higher mean ablation power, and lower wall thickness. Greater impedance drop was univariably associated with HDR. Conclusion: Outcomes of the TRV are associated with conventional ablation parameters (e.g., duration and power) but also local wall thickness. Catheter stability seems important for successful lesion assessment with the TRV. Further reduction of missing outcomes and validation of the tool are warranted before widespread use.

12.
Pacing Clin Electrophysiol ; 46(11): 1403-1411, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37724739

RESUMO

BACKGROUND: High-density (HD) mapping is increasingly used to characterize arrhythmic substrate for ablation of atypical atrial flutters (AAFl). However, results on clinical outcomes and factors that are associated with arrhythmia recurrence are scarce. METHODS: Single-center, prospective, observational cohort study that enrolled patients with catheter ablation for AAFl using a HD mapping system and a grid-shaped mapping catheter. Procedural characteristics, rates of atrial flutter recurrence, and factors that were associated with atrial flutter recurrence were evaluated. RESULTS: Sixty-one patients with a total of 94 AAFl were included in the cohort. HD mapping was used to successfully identify the flutter circuit of 80/94 AAFl. The circuit was not identified for 14/94 AAFl in 11 patients. Critical isthmuses were identified and ablated in 29 patients (48%). Acute procedural success was achieved in 52 patients (85%), and 37 patients (61%) remained free from atrial flutter recurrence during a follow up of 1.3 [1.0-2.1] years. Atrial flutter recurrence was univariably associated with presence of a non-identified flutter circuit (HR:2.6 95% CI [1.1-6.3], p = .04) and critical isthmus-targeted ablation (HR:0.4 [0.15-0.90], p = .03). In multivariable regression analyses, critical isthmus ablation remained significant (HR:0.4 [0.16-0.97], p = .04), whereas presence of a non-identified flutter did not (HR:2.4 [0.96-5.8], p = .06). CONCLUSION: HD mapping was successfully used to identify the majority of AAFl circuits. Ablation resulted in freedom from atrial flutter recurrence in 61% of the cohort. Successful identification of all flutter circuits and critical isthmuses appears to be beneficial for long-term outcomes.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Estudos Prospectivos , Estudos de Coortes , Ablação por Cateter/métodos
13.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622592

RESUMO

The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how elimination of ectopic activity from the pulmonary veins (PVs) resulted in a marked reduction of atrial fibrillation (AF). The past 25 years have seen an incredible surge in scientific interest to develop new catheters and energy sources to optimize durability and safety of ablation, as well as study the mechanisms for AF and devise ablation strategies. While ablation in the beginning was performed with classic 4 mm tip catheters that emitted radiofrequency (RF) energy to create tissue lesions, this evolved to using irrigation and contact force (CF) measurement while increasing power. Also, so-called single-shot devices were developed with balloons and arrays to create larger contiguous lesions, and energy sources changed from RF current to cryogenic ablation and more recently pulsed field ablation with electrical current. Although PV ablation has remained the basis for every AF ablation, it was soon recognized that this was not enough to cure all patients, especially those with non-paroxysmal AF. Standardized approaches for additional ablation targets have been used but have not been satisfactory in all patients so far. This led to highly technical mapping systems that are meant to unravel the drivers for the maintenance of AF. In the following sections, the development of energies, strategies, and tools is described with a focus on the contribution of Europace to publish the outcomes of studies that were done during the past 25 years.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Terapia de Eletroporação Irreversível
14.
JACC Cardiovasc Interv ; 16(15): 1889-1898, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37587597

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) procedures are widely guided by standard transesophageal echocardiography (TEE) probes, requiring general anesthesia in most patients. The use of miniaturized TEE probes allows for LAAO guidance under local anesthesia and offers an attractive imaging alternative to standard TEE probes. OBJECTIVES: The aim of this study was to assess the safety and efficacy of miniaturized TEE probes for procedural guidance of LAAO. METHODS: Multicenter retrospective observational study of LAAO procedures performed under miniaturized TEE guidance and conscious sedation. The primary efficacy endpoint was technical success. The secondary efficacy endpoint was procedural success (technical success without major periprocedural complications). The safety outcome was a composite of major periprocedural complications. RESULTS: A total of 546 consecutive LAAO procedures were performed in 5 European centers. Technical success was achieved in 534 (98.0%) patients. Sixteen major periprocedural complications occurred in 15 (2.9%) patients, yielding a procedural success rate of 97.0%. Conversion to general anesthesia was required in 4 (0.7%) patients. Short-term imaging follow-up was available in 422 patients with an incidence of major (>5 mm) TEE-detected residual leaks of 0.7%, complete LAA occlusion of 82.2% on cardiac computed tomography, and device-related thrombus of 5%. As compared with procedural 2-dimensional imaging for device sizing, preprocedural assessment by 3-dimensional imaging resulted in improved technical success (100% vs 95.0%; P < 0.001). CONCLUSIONS: LAAO under conscious sedation and miniaturized TEE guidance is safe and feasible with a high rate of technical success and a low rate of periprocedural complications.


Assuntos
Apêndice Atrial , Ecocardiografia Transesofagiana , Humanos , Sedação Consciente/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Anestesia Geral
15.
Heart Rhythm ; 20(12): 1649-1656, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37579867

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) delivers 80 J shocks from an 8 cm left-parasternal coil to a 59 cm3 left lateral pulse generator (PG). A system that defibrillates with lower energy could significantly reduce PG size. Computer modeling and animal studies suggested that a second shock coil either parallel to the left-parasternal coil or transverse from the xiphoid to the PG pocket would significantly reduce the defibrillation threshold. OBJECTIVE: The purpose of this study was to acutely assess the defibrillation efficacy of parallel and transverse configurations in patients receiving an S-ICD. METHODS: Testing was performed in patients receiving a conventional S-ICD system. Success at 65 J was required before investigational testing. A second electrode was temporarily inserted from the xiphoid incision connected to the PG with an investigational Y-adapter. Phase 1 (n = 11) tested the parallel configuration. Phase 2 (n = 21) tested both parallel and transverse configurations in random order. RESULTS: This study enrolled 35 patients (28 males (80%); mean age 51 ± 17 years; left ventricular ejection fraction 40% ± 15%; body mass index 26 ± 4 kg/m2; prior myocardial infarction 46%; congestive heart failure 49%; cardiomyopathy 63%). Compared to the conventional S-ICD system, mean shock impedance decreased for both parallel (69 ± 15 Ω vs 86 ± 20 Ω; n = 33; P < .001) and transverse (56 ± 14 Ω vs 81 ± 21 Ω; n = 20; P < .001) configurations. Shock success rates at 20, 30, and 40 J were 55%, 79%, 97%, and 25%, 70%, 90% for parallel and transverse configurations, respectively. Defibrillation threshold testing was well tolerated with no serious adverse events. CONCLUSION: Adding a second shock coil, particularly in the parallel configuration, significantly reduced the impedance and had a high likelihood of defibrillation success at energies ≤40 J. This may enable the development of a smaller S-ICD.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Massa Corporal , Cardiomiopatias/etiologia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Volume Sistólico , Fibrilação Ventricular/etiologia , Função Ventricular Esquerda
17.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520021

RESUMO

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

18.
Neth Heart J ; 31(7-8): 309-314, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37498467

RESUMO

BACKGROUND: The genetic risk haplotype DPP6 has been linked to familial idiopathic ventricular fibrillation (IVF), but the associated long-term outcomes are unknown. METHODS: DPP6 risk haplotype-positive family members (DPP6 cases) and their risk haplotype-negative relatives (DPP6 controls) were included. Clinical follow-up data were collected through March 2023. Implantable cardioverter-defibrillator (ICD) indication was divided in primary or secondary prevention. Cumulative survival and event rates were calculated. RESULTS: We included 327 DPP6 cases and 315 DPP6 controls. Median follow-up time was 9 years (interquartile range: 4-12). Of the DPP6 cases, 129 (39%) reached the composite endpoint of appropriate ICD shock, sudden cardiac arrest or death, at a median age of 45 years (range: 15-97). Median overall survival was 83 years and 87 years for DPP6 cases and DPP6 controls, respectively (p < 0.001). In DPP6 cases, median overall survival was shorter for males (74 years) than females (85 years) (p < 0.001). Of the DPP6 cases, 97 (30%) died, at a median age of 50 years. With a prophylactic ICD implantation advise based on risk haplotype, sex and age, 137 (42%) of DPP6 cases received an ICD, for primary prevention (n = 109) or secondary prevention (n = 28). In the primary prevention subgroup, 10 patients experienced a total of 34 appropriate ICD shocks, and there were no deaths during follow-up. DPP6 cases with a secondary prevention ICD experienced a total of 231 appropriate ICD shocks. CONCLUSION: Patients with the DPP6 risk haplotype, particularly males, are at an increased risk of IVF and sudden cardiac death. Using a risk stratification approach based on risk haplotype, sex and age, a substantial proportion of patients with a primary prevention ICD experienced appropriate ICD shocks, showing the benefit of prophylactic ICD implantation with this strategy.

20.
Heart Rhythm ; 20(8): 1128-1135, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37271354

RESUMO

BACKGROUND: Adequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing. OBJECTIVE: The purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort. METHODS: In this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ≤2.0 V at implantation and without ≥1.5-V increase at the last follow-up visit. RESULTS: A total of 179 patients were included (mean age 79 ± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 ± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0-88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%). CONCLUSION: The long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold.


Assuntos
Marca-Passo Artificial , Humanos , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/terapia , Resultado do Tratamento , Estudos Retrospectivos , Lipopolissacarídeos , Desenho de Equipamento , Estimulação Cardíaca Artificial/efeitos adversos