Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-20426013

RESUMO

This contribution reports the development and initial testing of a Mobile Robot System for Surgical Craniotomy, the Craniostar. A kinematic system based on a unicycle robot is analysed to provide local positioning through two spiked wheels gripping directly onto a patients skull. A control system based on a shared control system between both the Surgeon and Robot is employed in a hand-held design that is tested initially on plastic phantom and swine skulls. Results indicate that the system has substantially lower risk than present robotically assisted craniotomies, and despite being a hand-held mobile robot, the Craniostar is still capable of sub-millimetre accuracy in tracking along a trajectory and thus achieving an accurate transfer of pre-surgical plan to the operating room procedure, without the large impact of current medical robots based on modified industrial robots.


Assuntos
Craniotomia/instrumentação , Sistemas Homem-Máquina , Robótica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Animais , Craniotomia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Miniaturização , Reprodutibilidade dos Testes , Robótica/métodos , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos , Suínos
2.
Comput Aided Surg ; 8(5): 247-56, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-15529954

RESUMO

OBJECTIVE: Today's surgical robots normally perform "simple" trajectories, e.g., assisting as tool-holding devices in neurosurgery, or milling linear paths for cavities in total hip replacement. From a clinical point of view, it is still a complex undertaking to implement robots in the operating room. Until now, robot systems have not been used in patient trials to mill "complex" trajectories, which involve many positional and orientation changes and are often necessary in cranio-maxillofacial (CMF) surgery. This paper presents the RobaCKa surgical robot system, which allows more precise execution of surgical interventions and milling of "complex" trajectories. MATERIALS AND METHODS: The main components of the RobaCKa system are a (former) CASPAR robot system, a POLARIS system, and a force-torque sensor. RESULTS: In the first patient trial (April 2003) the planned trajectory was executed with an error of 0.66 +/- 0.2 mm. CONCLUSIONS: The use of former industrial robots for surgical applications is possible but complex. The advantages are improved precision and quality and the possibility of documentation. The use of such systems is normally limited to research institutions or large clinics, because it is hardly possible to implement the necessary technical and logistic efforts in routine surgical work.


Assuntos
Craniotomia/instrumentação , Robótica , Cirurgia Assistida por Computador/instrumentação , Craniotomia/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA