Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Atherosclerosis ; 318: 22-31, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33450475

RESUMO

BACKGROUND AND AIMS: The value of serial coronary artery calcium (CAC) scores to predict changes in absolute myocardial perfusion and epicardial vasomotor function is poorly documented. This study explored the association between progression of CAC score and changes in absolute myocardial perfusion. METHODS: Fifty-three patients (26% female) with de novo single-vessel coronary artery disease underwent [15O]H2O positron emission tomography/computed tomography at 1 month (baseline), 1 year, and 3 years after complete revascularization with percutaneous coronary intervention (PCI) to assess CAC scores, hyperemic myocardial blood flow (hMBF), coronary flow reserve (CFR) and cold pressor test MBF (CPT-MBF), within the context of the VANISH trial. RESULTS: Baseline CAC score was 0 in 9%, 0.1-99.9 in 40%, 100-399.9 in 36% and ≥400 in 15% of patients, respectively. Mixed model-analysis allowed for averaging perfusion indices over all time points: hMBF (3.74 ± 0.83; 3.33 ± 0.79; 3.08 ± 0.78 and 2.44 ± 0.74 mL min-1·g-1) and CFR (3.82 ± 1.12; 3.17 ± 0.80; 3.19 ± 0.81; 2.63 ± 0.92) were lower among higher baseline CAC groups (p < 0.01; p = 0.03). However, no significant interaction was found between baseline CAC groups and time after PCI for all perfusion indices, denoting that evolution of perfusion indices over time was not significantly different between CAC groups. Furthermore, CAC progression was not correlated with evolution of hMBF (r = 0.08, p = 0.57), CFR (r = 0.09, p = 0.53) or CPT-MBF (r = 0.03, p = 0.82) during 3 years of follow-up. CONCLUSIONS: Higher baseline CAC was associated with lower hMBF and CFR. However, both baseline CAC and its progression were not associated with evolution of absolute hMBF, CFR and CPT-MBF over time, suggesting that CAC score and progression of CAC are poor indicators of change in absolute myocardial perfusion.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Cálcio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Perfusão , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons
2.
Neth Heart J ; 28(Suppl 1): 57-65, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32780333

RESUMO

Determining the anatomic severity and extent of coronary artery disease (CAD) by means of coronary computed tomography angiography (CCTA) and its effect on perfusion using myocardial perfusion imaging (MPI) form the pillars of the non-invasive imaging assessment of CAD. This review will 1) focus on CCTA and [15O]H2O positron emission tomography MPI as stand-alone imaging modalities and their combined use for detecting CAD, 2) highlight some of the lessons learned from the PACIFIC trial (Comparison of Coronary CT Angiography, SPECT, PET, and Hybrid Imaging for Diagnosis of Ischemic Heart Disease Determined by Fractional Flow Reserve (FFR) (NCT01521468)), and 3) discuss the use of [15O]H2O PET MPI in the clinical work-up of patients with a chronic coronary total occlusion (CTO).

3.
J Cardiovasc Comput Tomogr ; 14(1): 60-67, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31302028

RESUMO

BACKGROUND: Scan quality can have a significant effect on the diagnostic performance of non-invasive imaging techniques. However, the extent of its influence has scarcely been investigated in a head-to-head manner. METHODS: Two-hundred and eight patients underwent CCTA, SPECT, and PET prior to invasive fractional flow reserve measurements. Scan quality was classified as either good, moderate, or poor. RESULTS: Distribution of good, moderate, and poor quality scans was; CCTA; 66%, 22%, 13%; SPECT; 52%, 38%, 9%; PET; 86%, 13%, 1%. Good quality CCTA scans possessed a higher specificity (75% vs. 31%, p = 0.001), positive predictive value (PPV, 71% vs. 51%, p = 0.050), and accuracy (80% vs. 60%, p = 0.009) compared to moderate quality scans, while sensitivity (94%) and negative predictive value (NPV, 88%) were similar to moderate and poor quality scans. Sensitivity (76%), NPV (84%), and accuracy (85%) of good quality SPECT scans was superior to those of moderate (41% p = 0.001, 56% p = 0.010, 70% p = 0.010) and poor quality (30% p = 0.003, 65% p = 0.069, 63% p = 0.038). Specificity (92%) and PPV (87%) of good quality SPECT scans did not differ from scans of diminished quality. Good quality PET scans exhibited high sensitivity (84%), specificity (86%), NPV (88%), PPV (81%) and accuracy (85%), which was comparable to scans of lesser quality. Good quality CCTA, SPECT, and PET scans demonstrated a similar diagnostic accuracy (p = 0.247). CONCLUSION: Diagnostic performance of CCTA, and SPECT is hampered by scan quality, while the diagnostic value of PET is not affected. Good quality CCTA, SPECT, and PET scans possess a high diagnostic accuracy.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
4.
Data Brief ; 27: 104584, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31687432

RESUMO

Scan quality directly impacts the diagnostic performance of non-invasive imaging modalities as reported in a substudy of the PACIFC-trial: "Impact of Scan Quality on the Diagnostic Performance of CCTA, SPECT, and PET for Diagnosing Myocardial Ischemia Defined by Fractional Flow Reserve" [1]. This Data-in-Brief paper supplements the hereinabove mentioned article by presenting the diagnostic performance of CCTA, SPECT, and PET on a per vessel level for the detection of hemodynamic significant coronary artery disease (CAD) when stratified according to scan quality and vascular territory.

5.
J Cardiovasc Comput Tomogr ; 13(4): 179-187, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31302027

RESUMO

BACKGROUND: A diminished coronary lumen volume to left ventricle mass ratio (V/M) derived from coronary computed tomography angiography (CCTA) has been proposed as factor contributing to impaired myocardial blood flow (MBF) even in the absence of obstructive disease on invasive coronary angiography (ICA). METHODS: Patients underwent CCTA, and positron emission tomography (PET) prior to ICA. Matched global V/M, global, and vessel specific hyperaemic MBF (hMBF), coronary flow reserve (CFR), and, FFR were available for 431 vessels in 152 patients. The median V/M (20.71 mm3/g) was used to divide the population into patients with either a low V/M or a high V/M. RESULTS: Overall, a higher percentage of vessels with an abnormal hMBF and FFR (34% vs. 19%, p = 0.009 and 20% vs. 9%, p = 0.004), as well as a lower FFR (0.93 [interquartile range: 0.85-0.97] vs. 0.95 [0.89-0.98], p = 0.016) values were observed in the low V/M group. V/M was weakly associated with vessel specific hMBF (R = 0.148, p = 0.027), and FFR (R = 0.156, p < 0.001). Among vessels with non-obstructive CAD on ICA (361 vessels), no association between V/M and vessel specific hMBF nor CFR was noted. However, in the absence of obstructive CAD, V/M was associated with (R = 0.081, p = 0.027), and independently predictive for FFR (p = 0.047). CONCLUSION: Overall, an abnormal vessel specific hMBF and FFR were more prevalent in patients with a low V/M compared to those with a high V/M. Furthermore, V/M was weakly associated with vessel specific hMBF and FFR. In the absence of obstructive CAD on ICA, V/M was weakly associated with notwithstanding independently predictive for FFR.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Ventrículos do Coração/diagnóstico por imagem , Idoso , Ensaios Clínicos como Assunto , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
6.
Neth Heart J ; 26(10): 473-483, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30171434

RESUMO

INTRODUCTION: Optical coherence tomography (OCT) enables detailed imaging of the coronary wall, lumen and intracoronary implanted devices. Responding to the lack of specific appropriate use criteria (AUC) for this technique, we conducted a literature review and a procedure for appropriate use criteria. METHODS: Twenty-one of all 184 members of the Dutch Working Group on Interventional Cardiology agreed to evaluate 49 pre-specified cases. During a meeting, factual indications were established whereupon members individually rated indications on a 9-point scale, with the opportunity to substantiate their scoring. RESULTS: Twenty-six indications were rated 'Appropriate', eighteen indications 'May be appropriate', and five 'Rarely appropriate'. Use of OCT was unanimously considered 'Appropriate' in stent thrombosis, and 'Appropriate' for guidance in PCI, especially in distal left main coronary artery and proximal left anterior descending coronary artery, unexplained angiographic abnormalities, and use of bioresorbable vascular scaffold (BVS). OCT was considered 'Rarely Appropriate' on top of fractional flow reserve (FFR) for treatment indication, assessment of strut coverage, bypass anastomoses or assessment of proximal left main coronary artery. CONCLUSIONS: The use of OCT in stent thrombosis is unanimously considered 'Appropriate' by these experts. Varying degrees of consensus exists on the appropriate use of OCT in other settings.

7.
Neth Heart J ; 24(5): 332-42, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26879946

RESUMO

BACKGROUND: Limited studies report on the additional prognostic value of coronary computed tomography angiography (CCTA) and the coronary artery calcium score (CACS). METHODS: For a median of 637 days, 1551 outpatients with chest pain, without known coronary artery disease (CAD) and low or intermediate pre-test probability of CAD, were followed for major adverse cardiac events (MACE), defined as death, myocardial infarction or late revascularisation. Cox proportional hazard regression was used to evaluate the independent prognostic value of CCTA and CACS. RESULTS: MACE occurred in 23 patients (1.5 %): death (3, 0.2 %), myocardial infarction (4, 0.3 %) and late revascularisation (16, 1.3 %). Multivariate analysis showed an independent prognostic value of CCTA (p < 0.001), CACS of 100-400 (p = 0.035) and CACS of > 400 (p = 0.021). CCTA showed obstructive CAD in 3.1 % of patients with CACS = 0. No events occurred in patients with CACS = 0 without obstructive CAD at CCTA, whereas 2/23 patients (9 %) with CACS = 0 with obstructive CAD had a MACE. CONCLUSIONS: Our study shows that both CCTA and higher CACS categories have independent prognostic value in chest pain patients with low to intermediate pre-test probability of obstructive CAD, in which CCTA is appropriate. Furthermore a non-negligible amount of patients with CACS = 0 have obstructive CAD at CCTA. CCTA can be used in these patients to identify those at risk for MACE.

8.
Neth Heart J ; 22(4): 151-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24574313

RESUMO

BACKGROUND: Single-photon emission computed tomography (SPECT) is an important prognostic tool in evaluating coronary artery disease (CAD), with a high negative predictive value (NPV) for the occurrence of major adverse cardiac events (MACE). The prognostic value of SPECT is disputed in women, patients with atrial fibrillation (AF), diabetes, left bundle branch block (LBBB) and renal impairment. METHODS: Seven hundred sixty-two patients without prior history of CAD who had SPECT without perfusion deficits were followed for 2 years for MACE. Predictive variables for the occurrence of MACE were reviewed by Cox proportional hazard regression, considering clinical information, resting-ECG data and SPECT data. RESULTS: The NPV of SPECT for the occurrence of MACE within 2 years was 95.8 %. Multivariate Cox regression revealed male gender as the only significant predictor for the occurrence of MACE, besides a positive stress ECG at SPECT and a low LVEF. AF, LBBB, renal impairment and diabetes had no significant effect on the prognosis after normal SPECT. CONCLUSION: SPECT with normal perfusion images has great NPV in a medium-sized clinic in the Netherlands, even in patients with LBBB, AF, diabetes and renal impairment. MACE-free survival, however, was negatively influenced by male gender; we therefore propose more caution in men.

9.
Clin Orthop Relat Res ; 469(6): 1743-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21318629

RESUMO

BACKGROUND: Radiographic diagnosis and followup studies of developmental dysplasia of the hip are commonly performed by measuring the acetabular index on radiographs using Hilgenreiner's method. The outcome of the measurement, however, depends on the orientation of the subject's pelvis relative to the xray source. The influence of pelvic rotation and tilt on the measurement error has been evaluated separately but not in combination. QUESTIONS/PURPOSES: We asked whether (1) combinations of pelvic rotation and tilt introduced systematic error in acetabular index measurement in a reproducible way, and (2) ratios proposed to evaluate either pelvic rotation (R(rotation)) or pelvic tilt (R(tilt)) are influenced by pelvic tilt and rotation, respectively. METHODS: Radiographic measurements of the acetabular index, R(rotation), and R(tilt) were performed on digitally reconstructed radiographs of one high-resolution three-dimensional CT dataset with various combinations of pelvic rotation and tilt. RESULTS: For rotations and tilt up to 12°, the average systematic errors in the acetabular index varied from -8.8° to 4.5°. Negative and positive error values can be interpreted as underestimations and overestimations of the acetabular index, respectively. Errors in acetabular index measurements were acceptable for R(rotation) values between 1.0 and 2.0 and R(tilt) values between 1.1 and 1.8. CONCLUSIONS: To limit the systematic error in assessing the acetabular index caused by pelvic misalignment, we recommend only radiographs acquired with ± 4° rotation and ± 4° tilt be considered acceptable.


Assuntos
Erros de Diagnóstico , Luxação Congênita de Quadril/diagnóstico por imagem , Quadril/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X/métodos , Acetábulo/diagnóstico por imagem , Criança , Humanos , Rotação
10.
Phys Med Biol ; 56(4): 1031-43, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21258138

RESUMO

Spatial and soft tissue information provided by magnetic resonance imaging can be very valuable during image-guided procedures, where usually only real-time two-dimensional (2D) x-ray images are available. Registration of 2D x-ray images to three-dimensional (3D) magnetic resonance imaging (MRI) data, acquired prior to the procedure, can provide optimal information to guide the procedure. However, registering x-ray images to MRI data is not a trivial task because of their fundamental difference in tissue contrast. This paper presents a technique that generates pseudo-computed tomography (CT) data from multi-spectral MRI acquisitions which is sufficiently similar to real CT data to enable registration of x-ray to MRI with comparable accuracy as registration of x-ray to CT. The method is based on a k-nearest-neighbors (kNN)-regression strategy which labels voxels of MRI data with CT Hounsfield Units. The regression method uses multi-spectral MRI intensities and intensity gradients as features to discriminate between various tissue types. The efficacy of using pseudo-CT data for registration of x-ray to MRI was tested on ex vivo animal data. 2D-3D registration experiments using CT and pseudo-CT data of multiple subjects were performed with a commonly used 2D-3D registration algorithm. On average, the median target registration error for registration of two x-ray images to MRI data was approximately 1 mm larger than for x-ray to CT registration. The authors have shown that pseudo-CT data generated from multi-spectral MRI facilitate registration of MRI to x-ray images. From the experiments it could be concluded that the accuracy achieved was comparable to that of registering x-ray images to CT data.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Estudos de Viabilidade , Humanos
11.
Med Phys ; 37(4): 1884-92, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443510

RESUMO

PURPOSE: The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a successful registration. Previously reported capture ranges, defined as the 95% success range, are in the order of 4-11 mm mean target registration error. In this article, a relatively computationally inexpensive and robust estimation method is proposed with the objective to enlarge the capture range. METHODS: The method uses the projection-slice theorem in combination with phase correlation in order to estimate the transform parameters, which provides an initialization of the subsequent registration procedure. RESULTS: The feasibility of the method was evaluated by experiments using digitally reconstructed radiographs generated from in vivo 3D-RX data. With these experiments it was shown that the projection-slice theorem provides successful estimates of the rotational transform parameters for perspective projections and in case of translational offsets. The method was further tested on ex vivo ovine x-ray data. In 95% of the cases, the method yielded successful estimates for initial mean target registration errors up to 19.5 mm. Finally, the method was evaluated as an initialization method for an intensity-based 2D-3D registration method. The uninitialized and initialized registration experiments had success rates of 28.8% and 68.6%, respectively. CONCLUSIONS: The authors have shown that the initialization method based on the projection-slice theorem and phase correlation yields adequate initializations for existing registration methods, thereby substantially enlarging the capture range of these methods.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Algoritmos , Animais , Área Sob a Curva , Cães , Desenho de Equipamento , Análise de Fourier , Humanos , Imageamento por Ressonância Magnética/métodos , Modelos Estatísticos , Distribuição Normal , Radiografia/métodos , Reprodutibilidade dos Testes , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...