Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cornea ; 35(12): 1578-1583, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27560033

RESUMO

PURPOSE: To document the time course and resolution of contact lens-related corneal infiltrative events (CIEs) comparing slit-lamp images with anterior segment ocular coherence tomography (AS-OCT) images. METHODS: Six silicone hydrogel (SiHy) soft contact lens (SCL) wearers presenting with newly diagnosed symptomatic CIEs were monitored with slit-lamp images, detailed drawings, and AS-OCT until the resolution of the CIE. A final follow-up visit was completed 4 weeks after CIE resolution to determine whether scar formation was present. Positive controls were 2 SiHy SCL wearers with established (inactive) corneal scars, and negative controls were 2 SiHy SCL wearers with clear corneas. High- and low-contrast logMAR visual acuities were measured, and subjective symptom questionnaires were completed at all visits. RESULTS: Clinical signs, vision, and symptoms improved in tandem with the resolution of the CIEs as measured by imaging methods. Calibrated measures of infiltrate width from a slit-lamp biomicroscope appear to be similar to calibrated images from AS-OCT. CONCLUSIONS: Although further studies are needed to develop standardized procedures, AS-OCT can be a useful tool to characterize the development, progression, and resolution of corneal infiltrates as an objective measure of resolution and scar formation.


Assuntos
Lentes de Contato Hidrofílicas/efeitos adversos , Ceratite/diagnóstico , Ceratite/etiologia , Leucócitos/patologia , Progressão da Doença , Feminino , Fluorofotometria , Seguimentos , Humanos , Ceratite/fisiopatologia , Ceratite/terapia , Masculino , Projetos Piloto , Estudos Prospectivos , Fatores de Risco , Lâmpada de Fenda , Inquéritos e Questionários , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Adulto Jovem
2.
Optom Vis Sci ; 93(6): 619-28, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26945176

RESUMO

PURPOSE: To determine if the use of pigments or adding polyvinyl pyrrolidone during the fabrication of 1-DAY ACUVUE DEFINE (AD) brand contact lenses impacts open-eye corneal swelling compared with no lens wear (NLW). METHODS: A partial double-masked, randomized, bilateral crossover study was conducted in 24 Asian subjects using AD, 1-DAY ACUVUE DEFINE with Lacreon (ADL), NLW, and a control lens with no tint (1-DAY ACUVUE MOIST [AM]). Central corneal thickness was measured before insertion and immediately after removal after 8 ± 1 h of open-eye wear using an optical pachymeter in one eye. Corneal thickness along a 10-mm cord was measured in the contralateral eye using the Visante optical coherence tomographer (OCT). Corneal swelling was tested for noninferiority using a 5% margin. The endothelial bleb response was measured at baseline and 20 min after lens insertion using specular microscopy. Subjective grading of corneal staining and limbal/bulbar hyperemia were also monitored. RESULTS: After 8 ± 1 h of open-eye wear, central corneal swelling across the study lenses with either optical pachymeter or OCT methods was negligible. Peripheral corneal swelling least-square mean differences with OCT were -0.03% (95% confidence interval [95% CI], -0.65 to 0.58%) and -0.26% (95% CI, -0.87 to 0.36%) between AD and ADL and the control lens (AM), respectively, and 1.67% (95% CI, 1.06 to 2.29%) and 1.45% (95% CI, 0.84 to 2.06%) between AD and ADL and NLW, respectively. No endothelial blebs were observed. No clinically significant differences were distinguished between the lenses and NLW for corneal staining and limbal/bulbar hyperemia. CONCLUSIONS: After 8 ± 1 h of open-eye wear, central and peripheral corneal swelling along the horizontal meridian with AD, ADL, AM, and NLW were equivalent. These results confirm that the addition of polyvinyl pyrrolidone or pigments to etafilcon A to obtain a limbal ring design have no impact on corneal swelling or limbal/bulbar hyperemia during normal open-eye wear.


Assuntos
Lentes de Contato Hidrofílicas/efeitos adversos , Córnea/patologia , Edema da Córnea/etiologia , Metacrilatos/efeitos adversos , Adulto , Córnea/diagnóstico por imagem , Edema da Córnea/diagnóstico por imagem , Técnicas Cosméticas , Estudos Cross-Over , Equipamentos Descartáveis , Método Duplo-Cego , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica , Adulto Jovem
3.
Clin Exp Optom ; 97(5): 411-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24689948

RESUMO

BACKGROUND: Limbal ring (also known as 'circle') contact lenses are becoming increasingly popular, especially in Asian markets because of their eye-enhancing effects. The pigment particles that give the eye-enhancing effects of these lenses can be found on the front or back surface of the contact lens or 'enclosed' within the lens matrix. The purpose of this research was to evaluate the pigment location and surface roughness of seven types of 'circle' contact lenses. METHODS: Scanning electron microscopic (SEM) analysis was performed using a variable pressure Hitachi S3400N instrument to discern the placement of lens pigments. Atomic force microscopy (Dimension Icon AFM from Bruker Nano) was used to determine the surface roughness of the pigmented regions of the contact lenses. Atomic force microscopic analysis was performed in fluid phase under contact mode using a Sharp Nitride Lever probe (SNL-10) with a spring constant of 0.06 N/m. Root mean square (RMS) roughness values were analysed using a generalised linear mixed model with a log-normal distribution. Least square means and their corresponding 95% confidence intervals were estimated for each brand, location and pigment combination. RESULTS: SEM cross-sectional images at 500× and 2,000× magnification showed pigment on the surface of six of the seven lens types tested. The mean depth of pigment for 1-DAY ACUVUE DEFINE (1DAD) lenses was 8.1 µm below the surface of the lens, while the remaining lens types tested had pigment particles on the front or back surface. Results of the atomic force microscopic analysis indicated that 1DAD lenses had significantly lower root mean square roughness values in the pigmented area of the lens than the other lens types tested. CONCLUSIONS: SEM and AFM analysis revealed pigment on the surface of the lens for all types tested with the exception of 1DAD. Further research is required to determine if the difference in pigment location influences on-eye performance.


Assuntos
Lentes de Contato , Equipamentos Descartáveis , Microscopia de Força Atômica/métodos , Microscopia Eletrônica de Varredura/métodos , Estudos Transversais , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes , Propriedades de Superfície
4.
Genet Med ; 14(9): 795-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22678084

RESUMO

PURPOSE: The aim of this study was to characterize the frequency and causes of anemia in glycogen storage disease type I. METHODS: Hematologic data and iron studies were available from 202 subjects (163 with glycogen storage disease Ia and 39 with glycogen storage disease Ib). Anemia was defined as hemoglobin concentrations less than the 5th percentile for age and gender; severe anemia was defined as presence of a hemoglobin <10 g/dl. RESULTS: In glycogen storage disease Ia, 68/163 patients were anemic at their last follow-up. Preadolescent patients tended to have milder anemia secondary to iron deficiency, but anemia of chronic disease predominated in adults. Severe anemia was present in 8/163 patients, of whom 75% had hepatic adenomas. The anemia improved or resolved in all 10 subjects who underwent resection of liver lesions. Anemia was present in 72% of patients with glycogen storage disease Ib, and severe anemia occurred in 16/39 patients. Anemia in patients with glycogen storage disease Ib was associated with exacerbations of glycogen storage disease enterocolitis, and there was a significant correlation between C-reactive protein and hemoglobin levels (P = 0.036). CONCLUSION: Anemia is a common manifestation of both glycogen storage disease Ia and Ib, although the pathophysiology appears to be different between these conditions. Those with severe anemia and glycogen storage disease Ia likely have hepatic adenomas, whereas glycogen storage disease enterocolitis should be considered in those with glycogen storage disease Ib.


Assuntos
Adenoma/patologia , Anemia/patologia , Enterocolite/patologia , Doença de Depósito de Glicogênio Tipo I/patologia , Deficiências de Ferro , Neoplasias Hepáticas/patologia , Adenoma/sangue , Adenoma/complicações , Adolescente , Adulto , Anemia/sangue , Anemia/complicações , Proteína C-Reativa/metabolismo , Criança , Pré-Escolar , Enterocolite/sangue , Enterocolite/complicações , Feminino , Doença de Depósito de Glicogênio Tipo I/sangue , Doença de Depósito de Glicogênio Tipo I/classificação , Doença de Depósito de Glicogênio Tipo I/complicações , Hemoglobinas/metabolismo , Humanos , Lactente , Ferro/sangue , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/complicações , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...