Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Microbiol ; 45(3): 816-21, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17166960

RESUMO

Blood culture bottles with antimicrobial removal systems are recommended for patients who develop fever while on antibiotics. This study compared the ability of Becton Dickinson (Sparks, MD) BACTEC PLUS bottles and bioMerieux (Durham, NC) BacT/Alert FA bottles to effectively remove vancomycin, cefoxitin, ceftriaxone, cefepime, piperacillin-tazobactam, ampicillin, oxacillin, gentamicin, and a combination of gentamicin/penicillin, thus allowing bacterial pathogens to grow. Each bottle was spiked with 10 ml of human blood, antibiotic, and strains of organisms susceptible to the antibiotic evaluated. The organisms used were type strains and clinical isolates of Staphylococcus aureus (methicillin susceptible and resistant), Streptococcus pneumoniae, a viridans streptococcus, Enterococcus faecalis, Enterococcus faecium, Streptococcus agalactiae, Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa. Testing was completed in triplicate, using 10 to 100 CFU/ml of organisms with various concentrations of each antibiotic. Two rounds of testing were completed per antibiotic/organism combination. Bottles were mixed and loaded onto their respective instruments as per the manufacturer's instructions. Antimicrobial removal was evaluated on the basis of time to detection of organism growth, for up to 5 days of incubation. Overall, the BacT/Alert FA system recovered 25.1% of strains from test bottles and 96.9% of strains from growth control bottles (no antibiotic added), and the BACTEC PLUS system recovered 95.1% of strains from test bottles and 100% of strains from growth control bottles. Both systems performed well in the detection of Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa in the presence of gentamicin. In the presence of ceftriaxone, neither system was able to recover Streptococcus pneumoniae. The ability to remove vancomycin and cefoxitin was also determined by measuring antibiotic levels remaining in bottles after 1 h of incubation. The results demonstrated remaining levels of 72 to 90% of vancomycin and 71 to 72% of cefoxitin in the BacT/Alert system. For the BACTEC system, remaining levels were 0 to 30% of vancomycin and 0% of cefoxitin. Under these simulated conditions, the BACTEC PLUS system was superior to the BacT/Alert FA system in recovering gram-positive and gram-negative bacterial pathogens in the presence of beta-lactam antibiotics, gentamicin/penicillin, and vancomycin.


Assuntos
Antibacterianos/farmacocinética , Técnicas Bacteriológicas , Sangue/microbiologia , Meios de Cultura , Bactérias Gram-Negativas/crescimento & desenvolvimento , Cocos Gram-Positivos/crescimento & desenvolvimento , Antibacterianos/uso terapêutico , Bacteriemia/tratamento farmacológico , Bacteriemia/microbiologia , Técnicas Bacteriológicas/instrumentação , Técnicas Bacteriológicas/métodos , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/tratamento farmacológico , Infecções por Bactérias Gram-Negativas/microbiologia , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Infecções por Bactérias Gram-Positivas/microbiologia , Cocos Gram-Positivos/isolamento & purificação , Humanos
2.
J Clin Microbiol ; 44(10): 3506-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17021074

RESUMO

We evaluated the accuracy of the BD Phoenix system for the identification (ID) and antimicrobial susceptibility testing (AST) of 251 isolates of the family Enterobacteriaceae representing 31 species. Organisms were inoculated onto the Phoenix panel according to the manufacturer's instructions. The results from conventional biochemical tests were used for the reference method for ID. Agar dilution, performed according to the CLSI guidelines, was the reference AST method. Essential and categorical agreements were determined. The overall levels of agreement for the genus- and species-level identifications were 95.6% and 94.4%, respectively. Fourteen isolates were incorrectly identified by the Phoenix system; 10 of these were incorrectly identified to the species level. Three of these were Enterobacter (Pantoea) species and four of these were Shigella spp. misidentified as Escherichia coli. For AST results, the essential and categorical agreements were 98.7% and 97.9%, respectively. The very major error, major error, and minor error rates were 0.38%, 0.33%, and 1.8%, respectively. Six isolates (three E. coli isolates and three Klebsiella isolates) were extended-spectrum beta-lactamase producers. All six were flagged by the Phoenix system expert rules. The Phoenix system compares favorably to traditional methods for ID and AST of Enterobacteriaceae.


Assuntos
Antibacterianos/farmacologia , Automação , Técnicas de Tipagem Bacteriana/instrumentação , Farmacorresistência Bacteriana , Enterobacteriaceae/classificação , Enterobacteriaceae/efeitos dos fármacos
3.
J Clin Microbiol ; 44(6): 2072-7, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16757600

RESUMO

We evaluated the Phoenix automated microbiology system (BD Diagnostic Systems, Sparks, MD) for the identification (ID) and antimicrobial susceptibility testing (AST) of challenge and clinical staphylococci and enterococci recovered from patients in a tertiary-care medical center. In total, 424 isolates were tested: 90 enterococci; 232 Staphylococcus aureus isolates, including 14 vancomycin-intermediate S. aureus isolates; and 102 staphylococci other than S. aureus (non-S. aureus). The Phoenix panels were inoculated according to the manufacturer's instructions. The reference methods for ID comparisons were conventional biochemicals and cell wall fatty acid analysis with the Sherlock microbial identification system (v 3.1; MIDI, Inc. Newark, DE). Agar dilution was the reference AST method. The overall rates of agreement for identification to the genus and the species levels were 99.7% and 99.3%, respectively. All S. aureus isolates and enterococci were correctly identified by the Phoenix panels. For the non-S. aureus staphylococci, there was 98.0% agreement for the ID of 16 different species. The AST results were stratified by organism group. For S. aureus, the categorical agreement (CA) and essential agreement (EA) were 98.2% and 98.8%, respectively. Three of three very major errors (VMEs; 1.7%) were with oxacillin. For non-S. aureus staphylococci, the CA, EA, VME, major errors, and minor error rates were 95.7%, 96.8%, 0.7%, 1.7%, and 2.9%, respectively. The two VMEs were with oxacillin. For the enterococci, there was 100% CA and 99.3% EA. All 36 vancomycin-resistant enterococci were detected by the Phoenix system. The Phoenix system compares favorably to traditional methods for the ID and AST of staphylococci and enterococci.


Assuntos
Antibacterianos/farmacologia , Enterococcus/classificação , Enterococcus/efeitos dos fármacos , Staphylococcus/classificação , Staphylococcus/efeitos dos fármacos , Técnicas de Tipagem Bacteriana , Farmacorresistência Bacteriana , Enterococcus/isolamento & purificação , Humanos , Testes de Sensibilidade Microbiana/métodos , Staphylococcus/isolamento & purificação
4.
J Clin Microbiol ; 44(3): 1105-7, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16517905

RESUMO

The performance characteristics of Xpect RSV (XP) and Binax Now RSV (BN) were compared to those of direct fluorescent-antibody staining and/or tissue culture for detection of respiratory syncytial virus (RSV) in nasopharyngeal aspirate and wash samples from children (n = 110) and adults (n = 66). The sensitivity, specificity, positive predictive value, and negative predictive value of XP were 75%, 98%, 95%, and 90%, respectively; and those of BN were 74%, 100%, 100%, and 90%, respectively. The performances of the assays were similar within a given age group and specimen type (nasopharyngeal aspirate or wash specimen). XP and BN are useful for screening for RSV in respiratory specimens when large volumes are tested or low levels of staffing occur.


Assuntos
Vírus Sincicial Respiratório Humano/isolamento & purificação , Virologia/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Técnica Direta de Fluorescência para Anticorpo/métodos , Técnica Direta de Fluorescência para Anticorpo/estatística & dados numéricos , Humanos , Lactente , Nasofaringe/virologia , Valor Preditivo dos Testes , Infecções por Vírus Respiratório Sincicial/diagnóstico , Infecções por Vírus Respiratório Sincicial/virologia , Sensibilidade e Especificidade , Virologia/estatística & dados numéricos
5.
J Clin Microbiol ; 44(3): 1145-9, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16517916

RESUMO

We evaluated a two-step algorithm for detecting toxigenic Clostridium difficile: an enzyme immunoassay for glutamate dehydrogenase antigen (Ag-EIA) and then, for antigen-positive specimens, a concurrent cell culture cytotoxicity neutralization assay (CCNA). Antigen-negative results were > or = 99% predictive of CCNA negativity. Because the Ag-EIA reduced cell culture workload by approximately 75 to 80% and two-step testing was complete in < or = 3 days, we decided that this algorithm would be effective. Over 6 months, our laboratories' expenses were US dollar 143,000 less than if CCNA alone had been performed on all 5,887 specimens.


Assuntos
Técnicas Bacteriológicas/métodos , Clostridioides difficile/isolamento & purificação , Algoritmos , Antígenos de Bactérias/análise , Técnicas Bacteriológicas/economia , Técnicas Bacteriológicas/estatística & dados numéricos , Clostridioides difficile/enzimologia , Clostridioides difficile/imunologia , Clostridioides difficile/patogenicidade , Custos e Análise de Custo , Citotoxinas/análise , Enterocolite Pseudomembranosa/diagnóstico , Glutamato Desidrogenase/imunologia , Humanos , Técnicas Imunoenzimáticas/economia , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Testes de Neutralização , Sensibilidade e Especificidade , Design de Software
6.
J Clin Microbiol ; 43(6): 2994-5, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15956442

RESUMO

We reviewed the results of repeated sample submissions within a 7-day time frame for Clostridium difficile toxin testing. A total of 2,940 samples were tested during a 3-month period using a cell culture cytotoxicity assay (CCCA). The results from all second samples (n = 1,101) were concordant with the original test result. In only two cases (0.8%; n = 247) was a third sample positive when the first two samples were negative. In this study, submission of multiple samples for CCCA did not increase detection of Clostridium difficile infection.


Assuntos
Toxinas Bacterianas/análise , Toxinas Bacterianas/toxicidade , Enterocolite Pseudomembranosa/diagnóstico , Células Cultivadas , Clostridioides difficile/metabolismo , Clostridioides difficile/patogenicidade , Enterocolite Pseudomembranosa/microbiologia , Fibroblastos , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...