Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
1.
Phys Rev Lett ; 130(26): 265101, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37450828

RESUMO

The propagation and energy coupling of intense laser beams in plasmas are critical issues in inertial confinement fusion. Applying magnetic fields to such a setup has been shown to enhance fuel confinement and heating. Here we report on experimental measurements demonstrating improved transmission and increased smoothing of a high-power laser beam propagating in a magnetized underdense plasma. We also measure enhanced backscattering, which our kinetic simulations show is due to magnetic confinement of hot electrons, thus leading to reduced target preheating.


Assuntos
Elétrons , Calefação , Frequência Cardíaca , Cinética , Lasers
2.
Phys Rev Lett ; 129(11): 114801, 2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36154426

RESUMO

Premature relativistic transparency of ultrathin, laser-irradiated targets is recognized as an obstacle to achieving a stable radiation pressure acceleration in the "light sail" (LS) mode. Experimental data, corroborated by 2D PIC simulations, show that a few-nm thick overcoat surface layer of high Z material significantly improves ion bunching at high energies during the acceleration. This is diagnosed by simultaneous ion and neutron spectroscopy following irradiation of deuterated plastic targets. In particular, copious and directional neutron production (significantly larger than for other in-target schemes) arises, under optimal parameters, as a signature of plasma layer integrity during the acceleration.

3.
Eur Urol Open Sci ; 42: 1-8, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35911084

RESUMO

Background: Standardized methods for reporting surgical quality have been described for all the major urological procedures apart from radical nephroureterectomy (RNU). Objective: To propose a tetrafecta criterion for assessing the quality of RNU based on a consensus panel within the Young Association of Urology (YAU) Urothelial Group, and to test the impact of this tetrafecta in a multicenter, large contemporary cohort of patients treated with RNU for upper tract urothelial carcinoma (UTUC). Design setting and participants: This was a retrospective analysis of 1765 patients with UTUC treated between 2000 and 2021. Outcome measurements and statistical analysis: We interviewed the YAU Urothelial Group to propose and score a list of items to be included in the "RNU-fecta." A ranking was generated for the criteria with the highest sum score. These criteria were applied to a large multicenter cohort of patients. Kaplan-Meier curves were built to evaluate differences in overall survival (OS) rates between groups, and a multivariable logistic regression model was used to find the predictors of achieving the RNU tetrafecta. Results and limitations: The criteria with the highest score included three surgical items such as negative soft tissue surgical margins, bladder cuff excision, lymph node dissection according to guideline recommendations, and one oncological item defined by the absence of any recurrence in ≤12 mo. These items formed the RNU tetrafecta. Within a median follow-up of 30 mo, 52.6% of patients achieved the RNU tetrafecta. The 5-yr OS rates were significantly higher for patients achieving tetrafecta than for their counterparts (76% vs 51%). Younger age, lower body mass index, and robotic approach were found to be independent predictors of tetrafecta achievement. Conversely, a higher Eastern Cooperative Oncology Group score, higher clinical stage, and bladder cancer history were inversely associated with tetrafecta. Conclusions: Herein, we present a "tetrafecta" composite endpoint that may serve as a potential tool to assess the overall quality of the RNU procedure. Pending external validation, this tool could allow a comparison between surgical series and may be useful for assessing the learning curve of the procedure as well as for evaluating the impact of new technologies in the field. Patient summary: In this study, a tetrafecta criterion was developed for assessing the surgical quality of radical nephroureterectomy in patients with upper tract urothelial carcinoma. Patients who achieved tetrafecta had higher 5-yr overall survival rates than those who did not.

4.
Rev Sci Instrum ; 93(5): 053303, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35649771

RESUMO

Image plates (IPs) are a popular detector in the field of laser driven ion acceleration, owing to their high dynamic range and reusability. An absolute calibration of these detectors to laser-driven protons in the routinely produced tens of MeV energy range is, therefore, essential. In this paper, the response of Fujifilm BAS-TR IPs to 1-40 MeV protons is calibrated by employing the detectors in high resolution Thomson parabola spectrometers in conjunction with a CR-39 nuclear track detector to determine absolute proton numbers. While CR-39 was placed in front of the image plate for lower energy protons, it was placed behind the image plate for energies above 10 MeV using suitable metal filters sandwiched between the image plate and CR-39 to select specific energies. The measured response agrees well with previously reported calibrations as well as standard models of IP response, providing, for the first time, an absolute calibration over a large range of proton energies of relevance to current experiments.

5.
Rev Sci Instrum ; 93(3): 033304, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35364990

RESUMO

The response of the BAS-TR image plate (IP) was absolutely calibrated using a CR-39 track detector for high linear energy transfer Au ions up to ∼1.6 GeV (8.2 MeV/nucleon), accelerated by high-power lasers. The calibration was carried out by employing a high-resolution Thomson parabola spectrometer, which allowed resolving Au ions with closely spaced ionization states up to 58+. A response function was obtained by fitting the photo-stimulated luminescence per Au ion for different ion energies, which is broadly in agreement with that expected from ion stopping in the active layer of the IP. This calibration would allow quantifying the ion energy spectra for high energy Au ions, which is important for further investigation of the laser-based acceleration of heavy ion beams.

6.
Phys Rev Lett ; 127(19): 194801, 2021 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-34797126

RESUMO

We report on the selective acceleration of carbon ions during the interaction of ultrashort, circularly polarized and contrast-enhanced laser pulses, at a peak intensity of 5.5×10^{20} W/cm^{2}, with ultrathin carbon foils. Under optimized conditions, energies per nucleon of the bulk carbon ions reached significantly higher values than the energies of contaminant protons (33 MeV/nucleon vs 18 MeV), unlike what is typically observed in laser-foil acceleration experiments. Experimental data, and supporting simulations, emphasize different dominant acceleration mechanisms for the two ion species and highlight an (intensity dependent) optimum thickness for radiation pressure acceleration; it is suggested that the preceding laser energy reaching the target before the main pulse arrives plays a key role in a preferential acceleration of the heavier ion species.

7.
Phys Rev E ; 104(2-2): 025210, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34525575

RESUMO

Laser-driven ion acceleration has attracted global interest for its potential towards the development of a new generation of compact, low-cost accelerators. Remarkable advances have been seen in recent years with a substantial proton energy increase in experiments, when nanometer-scale ultrathin foil targets and high-contrast intense lasers are applied. However, the exact acceleration dynamics and particularly the ion energy scaling laws in this novel regime are complex and still unclear. Here, we derive a scaling law for the attainable maximum ion energy from such laser-irradiated nanometer-scale foils based on analytical theory and multidimensional particle-in-cell simulations, and further show that this scaling law can be used to accurately describe experimental data over a large range of laser and target parameters on different facilities. This provides crucial references for parameter design and experimentation of the future laser devices towards various potential applications.

8.
Nat Commun ; 12(1): 334, 2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33436570

RESUMO

Magnetized plasma interactions are ubiquitous in astrophysical and laboratory plasmas. Various physical effects have been shown to be important within colliding plasma flows influenced by opposing magnetic fields, however, experimental verification of the mechanisms within the interaction region has remained elusive. Here we discuss a laser-plasma experiment whereby experimental results verify that Biermann battery generated magnetic fields are advected by Nernst flows and anisotropic pressure effects dominate these flows in a reconnection region. These fields are mapped using time-resolved proton probing in multiple directions. Various experimental, modelling and analytical techniques demonstrate the importance of anisotropic pressure in semi-collisional, high-ß plasmas, causing a reduction in the magnitude of the reconnecting fields when compared to resistive processes. Anisotropic pressure dynamics are crucial in collisionless plasmas, but are often neglected in collisional plasmas. We show pressure anisotropy to be essential in maintaining the interaction layer, redistributing magnetic fields even for semi-collisional, high energy density physics (HEDP) regimes.

9.
World J Urol ; 38(1): 143-150, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30993426

RESUMO

BACKGROUND: Basophils, eosinophils and monocytes may be involved in BCG-induced immune responses and be associated with outcomes of bladder cancer patients receiving intravesical BCG. Our objective was to explore the association of baseline counts of basophils, eosinophils and monocytes with outcomes of patients with high-grade T1 bladder cancer receiving a standard course of intravesical BCG. METHODS: We retrospectively reviewed medical records of patients with primary T1 HG/G3 bladder cancer. After re-TURBT, patients were treated with a 6-week course of intravesical BCG induction followed by intravesical BCG every week for 3 weeks given at 3, 6, 12, 18, 24, 30 and 36 months from initiation of therapy The analysis of potential risk factors for recurrence, muscle invasion and cancer-specific and overall survival was performed using univariable Cox regression models. Those factors that presented, at univariate analysis, an association with the event at a liberal p < 0.1, have been selected for the development of a multivariable model. RESULTS: A total of 1045 patients with primary T1 HG/G3 were included. A total of 678 (64.9%) recurrences, 303 (29.0%) progressions and 150 (14.3%) deaths were observed during follow-up. Multivariate analysis showed that logarithmic transformation of basophils count was associated with a 30% increment in the hazard of recurrence per unit increase of logarithmic basophils count (HR 1.30; 95% confidence interval 1.09-1.54; p = 0.0026). Basophil count modeled by quartiles was also significantly associated with time to recurrence [second vs. lower quartile HR 1.42 (1.12-1.79); p = 0.003, third vs. lower quartile HR 1.26 (1.01-1.57); p = 0.041; upper vs. lower quartile HR 1.36 (1.1-1.68); p = 0.005]. The limitations of a retrospective study are applicable. CONCLUSION: Baseline basophil count may predict recurrence in BCG-treated HG/G3 T1 bladder cancer patients. External validation is warranted.


Assuntos
Vacina BCG/administração & dosagem , Basófilos/patologia , Cistectomia/métodos , Recidiva Local de Neoplasia/diagnóstico , Estadiamento de Neoplasias/métodos , Neutrófilos/patologia , Neoplasias da Bexiga Urinária/terapia , Adjuvantes Imunológicos/administração & dosagem , Administração Intravesical , Adulto , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Seguimentos , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Neoplasias da Bexiga Urinária/patologia
10.
Intern Emerg Med ; 15(4): 645-654, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31786751

RESUMO

Prevalence and clinical impact of viral respiratory tract infections (VRTIs) on community-acquired pneumonia (CAP) has not been well defined so far. The aims of this study were to investigate the prevalence and the clinical impact of VRTIs in patients with CAP. Prospective study involving adult patients consecutively admitted at medical wards for CAP and tested for VRTIs by real-time PCR on pharyngeal swab. Patients' features were evaluated with regard to the presence of VRTI and aetiology of CAP. Clinical failure was a composite endpoint defined by worsening of signs and symptoms requiring escalation of antibiotic treatment or ICU admission or death within 30 days. 91 patients were enrolled, mean age 65.7 ± 10.6 years, 50.5% female. 62 patients (68.2%) had no viral co-infection while in 29 patients (31.8%) a VRTI was detected; influenza virus was the most frequently identified (41.9%). The two groups were similar in terms of baseline features. In presence of a VRTI, pneumonia severity index (PSI) was more frequently higher than 91 and patients had received less frequently pre-admission antibiotic therapy (adjusted OR 2.689, 95% CI 1.017-7.111, p = 0.046; adjusted OR 0.143, 95% CI 0.030-0.670, p = 0.014). Clinical failure and antibiotic therapy duration were similar with regards to the presence of VRTI and the aetiology of CAP. VRTIs can be detected in almost a third of adults with CAP; influenza virus is the most relevant one. VRTI was associated with higher PSI at admission, but it does not affect patients' outcome.


Assuntos
Infecções Comunitárias Adquiridas/microbiologia , Pneumonia/microbiologia , Infecções Respiratórias/virologia , Idoso , Coinfecção , Infecções Comunitárias Adquiridas/epidemiologia , Feminino , Hospitalização , Humanos , Itália/epidemiologia , Masculino , Pneumonia/epidemiologia , Prevalência , Estudos Prospectivos , Infecções Respiratórias/epidemiologia
11.
Rev Sci Instrum ; 90(8): 083303, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31472608

RESUMO

The Time-of-Flight (TOF) technique coupled with semiconductorlike detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detector's working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson parabola spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.

12.
Sci Rep ; 9(1): 4471, 2019 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-30872656

RESUMO

Protontherapy has emerged as more effective in the treatment of certain tumors than photon based therapies. However, significant capital and operational costs make protontherapy less accessible. This has stimulated interest in alternative proton delivery approaches, and in this context the use of laser-based technologies for the generation of ultra-high dose rate ion beams has been proposed as a prospective route. A better understanding of the radiobiological effects at ultra-high dose-rates is important for any future clinical adoption of this technology. In this study, we irradiated human skin fibroblasts-AG01522B cells with laser-accelerated protons at a dose rate of 109 Gy/s, generated using the Gemini laser system at the Rutherford Appleton Laboratory, UK. We studied DNA double strand break (DSB) repair kinetics using the p53 binding protein-1(53BP1) foci formation assay and observed a close similarity in the 53BP1 foci repair kinetics in the cells irradiated with 225 kVp X-rays and ultra- high dose rate protons for the initial time points. At the microdosimetric scale, foci per cell per track values showed a good correlation between the laser and cyclotron-accelerated protons indicating similarity in the DNA DSB induction and repair, independent of the time duration over which the dose was delivered.


Assuntos
Quebras de DNA de Cadeia Dupla , Fibroblastos/efeitos da radiação , Terapia com Prótons/instrumentação , Proteína 1 de Ligação à Proteína Supressora de Tumor p53/metabolismo , Linhagem Celular , Ciclotrons/instrumentação , Relação Dose-Resposta à Radiação , Fibroblastos/química , Fibroblastos/citologia , Humanos , Lasers , Estudos Prospectivos , Terapia com Prótons/efeitos adversos
13.
Phys Rev Lett ; 122(2): 025001, 2019 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-30720299

RESUMO

The propagation of fast electron currents in near solid-density media was investigated via proton probing. Fast currents were generated inside dielectric foams via irradiation with a short (∼0.6 ps) laser pulse focused at relativistic intensities (Iλ^{2}∼4×10^{19} W cm^{-2} µm^{2}). Proton probing provided a spatially and temporally resolved characterization of the evolution of the electromagnetic fields and of the associated net currents directly inside the target. The progressive growth of beam filamentation was temporally resolved and information on the divergence of the fast electron beam was obtained. Hybrid simulations of electron propagation in dense media indicate that resistive effects provide a major contribution to field generation and explain well the topology, magnitude, and temporal growth of the fields observed in the experiment. Estimations of the growth rates for different types of instabilities pinpoints the resistive instability as the most likely dominant mechanism of beam filamentation.

14.
Phys Rev Lett ; 120(20): 204801, 2018 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-29864368

RESUMO

A dual ion species plasma expansion scheme from a novel target structure is introduced, in which a nanometer-thick layer of pure deuterium exists as a buffer species at the target-vacuum interface of a hydrogen plasma. Modeling shows that by controlling the deuterium layer thickness, a composite H^{+}/D^{+} ion beam can be produced by target normal sheath acceleration (TNSA), with an adjustable ratio of ion densities, as high energy proton acceleration is suppressed by the acceleration of a spectrally peaked deuteron beam. Particle in cell modeling shows that a (4.3±0.7) MeV per nucleon deuteron beam is accelerated, in a directional cone of half angle 9°. Experimentally, this was investigated using state of the art cryogenic targetry and a spectrally peaked deuteron beam of (3.4±0.7) MeV per nucleon was measured in a cone of half angle 7°-9°, while maintaining a significant TNSA proton component.

15.
Nat Commun ; 9(1): 724, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29463872

RESUMO

The range of potential applications of compact laser-plasma ion sources motivates the development of new acceleration schemes to increase achievable ion energies and conversion efficiencies. Whilst the evolving nature of laser-plasma interactions can limit the effectiveness of individual acceleration mechanisms, it can also enable the development of hybrid schemes, allowing additional degrees of control on the properties of the resulting ion beam. Here we report on an experimental demonstration of efficient proton acceleration to energies exceeding 94 MeV via a hybrid scheme of radiation pressure-sheath acceleration in an ultrathin foil irradiated by a linearly polarised laser pulse. This occurs via a double-peaked electrostatic field structure, which, at an optimum foil thickness, is significantly enhanced by relativistic transparency and an associated jet of super-thermal electrons. The range of parameters over which this hybrid scenario occurs is discussed and implications for ion acceleration driven by next-generation, multi-petawatt laser facilities are explored.

16.
Int. braz. j. urol ; 44(1): 63-68, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-892940

RESUMO

ABSTRACT Objectives The aim of our study is to present early outcomes of our series of retroperitoneal-RAPN (Robot Assisted Partial Nephrectomy). Materials and methods From September 2010 until December 2015, we performed 81 RAPN procedures (44 at left kidney and 37 at right). Average size was 3cm (1-9). Average PADUA score 7.1 (5-10). Average surgical time (overall and only robot time), ischemia time, blood loss, pathological stage, complications and hospital stay have been recorded. Results All of the cases were completed successfully without any operative complication or surgical conversion. Average surgical time was 177 minutes (75-340). Operative time was 145 minutes (80-300), overall blood loss was 142cc (60-310cc). In 30 cases the pedicle was late clamped with an average ischemia time of 4 minutes (2-7). None of the patient had positive surgical margins at definitive histology (49pT1a, 12pT1b, 3pT2a, 2pT3a). Hospital stay was 3 days (2-7). Conclusions The retroperitoneal robotic partial nephrectomy approach is safe and allows treatment of even quite complex tumors. It also combines the already well known advantages guaranteed by the da Vinci® robotic surgical system, with the advantages of the retroperitoneoscopic approach.


Assuntos
Humanos , Masculino , Feminino , Espaço Retroperitoneal/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias Renais/cirurgia , Nefrectomia/métodos , Resultado do Tratamento , Pessoa de Meia-Idade
17.
Int Braz J Urol ; 44(1): 63-68, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29211396

RESUMO

OBJECTIVES: The aim of our study is to present early outcomes of our series of retroperitoneal-RAPN (Robot Assisted Partial Nephrectomy). MATERIALS AND METHODS: From September 2010 until December 2015, we performed 81 RAPN procedures (44 at left kidney and 37 at right). Average size was 3cm (1-9). Average PADUA score 7.1 (5-10). Average surgical time (overall and only robot time), ischemia time, blood loss, pathological stage, complications and hospital stay have been recorded. RESULTS: All of the cases were completed successfully without any operative complication or surgical conversion. Average surgical time was 177 minutes (75-340). Operative time was 145 minutes (80-300), overall blood loss was 142cc (60-310cc). In 30 cases the pedicle was late clamped with an average ischemia time of 4 minutes (2-7). None of the patient had positive surgical margins at definitive histology (49pT1a, 12pT1b, 3pT2a, 2pT3a). Hospital stay was 3 days (2-7). CONCLUSIONS: The retroperitoneal robotic partial nephrectomy approach is safe and allows treatment of even quite complex tumors. It also combines the already well known advantages guaranteed by the da Vinci® robotic surgical system, with the advantages of the retroperitoneoscopic approach.


Assuntos
Neoplasias Renais/cirurgia , Nefrectomia/métodos , Espaço Retroperitoneal/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Phys Rev Lett ; 119(18): 185002, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219555

RESUMO

We report on the first experimental observation of a current-driven instability developing in a quasineutral matter-antimatter beam. Strong magnetic fields (≥1 T) are measured, via means of a proton radiography technique, after the propagation of a neutral electron-positron beam through a background electron-ion plasma. The experimentally determined equipartition parameter of ε_{B}≈10^{-3} is typical of values inferred from models of astrophysical gamma-ray bursts, in which the relativistic flows are also expected to be pair dominated. The data, supported by particle-in-cell simulations and simple analytical estimates, indicate that these magnetic fields persist in the background plasma for thousands of inverse plasma frequencies. The existence of such long-lived magnetic fields can be related to analog astrophysical systems, such as those prevalent in lepton-dominated jets.

19.
Phys Rev Lett ; 119(5): 054801, 2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28949740

RESUMO

The acceleration of ions from ultrathin (10-100 nm) carbon foils has been investigated using intense (∼6×10^{20} W cm^{-2}) ultrashort (45 fs) laser pulses, highlighting a strong dependence of the ion beam parameters on the laser polarization, with circularly polarized (CP) pulses producing the highest energies for both protons and carbons (25-30 MeV/nucleon); in particular, carbon ion energies obtained employing CP pulses were significantly higher (∼2.5 times) than for irradiations employing linearly polarized pulses. Particle-in-cell simulations indicate that radiation pressure acceleration becomes the dominant mechanism for the thinnest targets and CP pulses.

20.
Sci Rep ; 7(1): 10891, 2017 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-28883424

RESUMO

The characteristics of laser driven proton beams can be efficiently controlled and optimised by employing a recently developed helical coil technique, which exploits the transient self-charging of solid targets irradiated by intense laser pulses. Here we demonstrate a well collimated (<1° divergence) and narrow bandwidth (~10% energy spread) proton beamlet of ~107 particles at 10 ± 0.5 MeV obtained by irradiating helical coil targets with a few joules, sub-ps laser pulses at an intensity of ~2 × 1019 W cm-2. The experimental data are in good agreement with particle tracing simulations suggesting post-acceleration of protons inside the coil at a rate ~0.7 MeV/mm, which is comparable to the results obtained from a similar coil target irradiated by a fs class laser at an order of magnitude higher intensity, as reported in S. Kar et al., Nat. Commun, 7, 10792 (2016). The dynamics of hot electron escape from the laser irradiated target was studied numerically for these two irradiation regimes, which shows that the target self-charging can be optimised at a pulse duration of few hundreds of fs. This information is highly beneficial for maximising the post-acceleration gradient in future experiments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...