Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Imaging ; 97: 102-111, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36632946

RESUMO

Magnitude-based PDFF (Proton Density Fat Fraction) and R2∗ mapping with resolved water-fat ambiguity is extended to calculate field inhomogeneity (field map) using the phase images. The estimation is formulated in matrix form, resolving the field map in a least-squares sense. PDFF and R2∗ from magnitude fitting may be updated using the estimated field maps. The limits of quantification of our voxel-independent implementation were assessed. Bland-Altman was used to compare PDFF and field maps from our method against a reference complex-based method on 152 UK Biobank subjects (1.5 T Siemens). A separate acquisition (3 T Siemens) presenting field inhomogeneities was also used. The proposed field mapping was accurate beyond double the complex-based limit range. High agreement was obtained between the proposed method and the reference in UK. Robust field mapping was observed at 3 T, for inhomogeneities over 400 Hz including rapid variation across edges. Field mapping following unambiguous magnitude-based water-fat separation was demonstrated in-vivo and showed potential at 3 T.


Assuntos
Imageamento por Ressonância Magnética , Água , Humanos , Imageamento por Ressonância Magnética/métodos , Prótons , Fígado , Reprodutibilidade dos Testes
2.
J Magn Reson Imaging ; 52(3): 807-820, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32147892

RESUMO

BACKGROUND: Magnetic resonance cholangiopancreatography (MRCP) is an important tool for noninvasive imaging of biliary disease, however, its assessment is currently subjective, resulting in the need for objective biomarkers. PURPOSE: To investigate the accuracy, scan/rescan repeatability, and cross-scanner reproducibility of a novel quantitative MRCP tool on phantoms and in vivo. Additionally, to report normative ranges derived from the healthy cohort for duct measurements and tree-level summary metrics. STUDY TYPE: Prospective. PHANTOMS/SUBJECTS: Phantoms: two bespoke designs, one with varying tube-width, curvature, and orientation, and one exhibiting a complex structure based on a real biliary tree. Subjects Twenty healthy volunteers, 10 patients with biliary disease, and 10 with nonbiliary liver disease. SEQUENCE/FIELD STRENGTH: MRCP data were acquired using heavily T2 -weighted 3D multishot fast/turbo spin echo acquisitions at 1.5T and 3T. ASSESSMENT: Digital instances of the phantoms were synthesized with varying resolution and signal-to-noise ratio. Physical 3D-printed phantoms were scanned across six scanners (two field strengths for each of three manufacturers). Human subjects were imaged on four scanners (two fieldstrengths for each of two manufacturers). STATISTICAL TESTS: Bland-Altman analysis and repeatability coefficient (RC). RESULTS: Accuracy of the diameter measurement approximated the scanning resolution, with 95% limits of agreement (LoA) from -1.1 to 1.0 mm. Excellent phantom repeatability was observed, with LoA from -0.4 to 0.4 mm. Good reproducibility was observed across the six scanners for both phantoms, with a range of LoA from -1.1 to 0.5 mm. Inter- and intraobserver agreement was high. Quantitative MRCP detected strictures and dilatations in the phantom with 76.6% and 85.9% sensitivity and 100% specificity in both. Patients and healthy volunteers exhibited significant differences in metrics including common bile duct (CBD) maximum diameter (7.6 mm vs. 5.2 mm P = 0.002), and overall biliary tree volume 12.36 mL vs. 4.61 mL, P = 0.0026). DATA CONCLUSION: The results indicate that quantitative MRCP provides accurate, repeatable, and reproducible measurements capable of objectively assessing cholangiopathic change. Evidence Level: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;52:807-820.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...