Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 67(7)2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35272282

RESUMO

Objective. A novel treatment modality is currently being developed that produces converging monoenergetic x-rays. Conventional application of dosimetric calibration as presented in protocol TG61 is not applicable. Furthermore, the dosimetry of the focal point of the converging beam is on the order of a few millimeters, requiring a high-resolution dosimeter. Here we present a procedure to calibrate radiochromic film for narrow-beam monoenergetic 60 keV photons as well as absolute dosimetry of monoenergetic focused x-rays. A study of the focal spot dose rate after passing through a bone-equivalent material was also done to quantify the effects of heterogeneous materials.Approach.This was accomplished by configuring a polyenergetic beam of equivalent energy using a clinical orthovoltage machine. Calibrated films were then used to perform absolute dosimetry of the converging beam by measuring the beam profile at various depths in water. Main Results.A method for calibrating radiochromic film has been developed and detailed that allows absolute dosimetry of a monoenergetic photon beam. Absolute dosimetry of a focused, mono-energetic beam resulted in a focal spot dose rate of ∼30 cGy min-1at a depth of 5 cm in water.Significance.This work serves to establish a dosimetry protocol for mono-energetic beam absolute dosimetry as well as the use of such a method for measurement of a novel teletherapy modality.


Assuntos
Dosimetria Fotográfica , Radiometria , Calibragem , Dosimetria Fotográfica/métodos , Fótons/uso terapêutico , Radiometria/métodos , Água
2.
Sci Rep ; 11(1): 19180, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34584192

RESUMO

We describe the development and analysis of a new teletherapy modality that, through a novel approach to targeted radiation delivery, has the potential to provide greater conformality than conventional photon-based treatments. The proposed system uses an X-ray lens to reflect photons from a conventional X-ray tube toward a focal spot. The resulting dose distributions have a highly localized peak dose, with lower doses in the converging radiation cone. Physical principles governing the design of this system are presented, along with a series of measurements analyzing various characteristics of the converging beam. The beam was designed to be nearly monoenergetic (~ 59 keV), with an energy bandwidth of approximately 10 keV allowing for treatment energies lower than conventional therapies. The focal spot was measured to be approximately 2.5 cm long and 4 mm wide. Mounting the proposed X-ray delivery system on a robotic arm would allow sub-millimeter accuracy in focal spot positioning, resulting in highly conformal dose distribution via the optimal placement of individual focal spots within the target volume. Aspects of this novel radiation beam are discussed considering their possible clinical application as a treatment approach that takes maximum advantage of the unique properties afforded by converging X-ray beam therapy.


Assuntos
Lentes , Fótons/uso terapêutico , Radioterapia Conformacional/instrumentação , Desenho de Equipamento , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
3.
Langmuir ; 27(22): 13415-9, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21988456

RESUMO

Ultraflat metal surfaces are used in template stripping (TS), which is a method for obtaining a metal with an average surface roughness on the order of <1 nm. This is important for plasmonics, for the production of high-quality SAM surfaces, and for many other applications. Herein we show for the first time that TS indeed introduces a very high density of surface nanodefects (twinning and stacking faults), which can strongly hinder surface-induced properties such as SAM ordering and plasmonic phenomena, despite the seemingly overall ultrahigh flatness. We have used state of the art characterization techniques such as HRXRD, spherical-aberration-corrected HRTEM, and STM. We also demonstrate how these nanodefects can be completely eliminated.

4.
Nat Mater ; 10(11): 890-6, 2011 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-21892179

RESUMO

Biominerals exhibit morphologies, hierarchical ordering and properties that invariably surpass those of their synthetic counterparts. A key feature of these materials, which sets them apart from synthetic crystals, is their nanocomposite structure, which derives from intimate association of organic molecules with the mineral host. We here demonstrate the production of artificial biominerals where single crystals of calcite occlude a remarkable 13 wt% of 20 nm anionic diblock copolymer micelles, which act as 'pseudo-proteins'. The synthetic crystals exhibit analogous texture and defect structures to biogenic calcite crystals and are harder than pure calcite. Further, the micelles are specifically adsorbed on {104} faces and undergo a change in shape on incorporation within the crystal lattice. This system provides a unique model for understanding biomineral formation, giving insight into both the mechanism of occlusion of biomacromolecules within single crystals, and the relationship between the macroscopic mechanical properties of a crystal and its microscopic structure.


Assuntos
Carbonato de Cálcio/química , Minerais/química , Polímeros/química , Cristalização , Micelas , Microscopia Eletrônica de Transmissão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...