Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Comput Methods Programs Biomed ; 141: 73-81, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28241970

RESUMO

BACKGROUND AND OBJECTIVES: Standardization of the carotid IMT requires a reference marker in ultrasound scans. It has been shown previously that manual reference marker and manually created carotid segments are used for measuring IMT in these segments. Manual methods are tedious, time consuming, subjective, and prone to errors. Bulb edge can be considered as a reference marker for measurements of the cIMT. However, bulb edge can be difficult to locate in ultrasound scans due to: (a) low signal to noise ratio in the bulb region as compared to common carotid artery region; (b) uncertainty of bulb location in craniocaudal direction; and (c) variability in carotid bulb shape and size. This paper presents an automated system (a class of AtheroEdge™ system from AtheroPoint™, Roseville, CA, USA) for locating the bulb edge as a reference marker and further develop segmental-IMT (sIMT) which measures IMT in 10mm segments (namely: s1, s2 and s3) proximal to the bulb edge. METHODS: The patented methodology uses an integrated approach which combines carotid geometry and pixel-classification paradigms. The system first finds the bulb edge and then measures the sIMT proximal to the bulb edge. The system also estimates IMT in bulb region (bIMT). The 649 image database consists of varying plaque (light, moderate to heavy), image resolutions, shapes, sizes and ethnicity. RESULTS: Our results show that the IMT contributions in different carotid segments are as follows: bulb-IMT 34%, s1-IMT 29.46%, s2-IMT 11.48%, and s3-IMT 12.75%, respectively. We compare our automated results against reader's tracings demonstrating the following performance: mean lumen-intima error: 0.01235 ± 0.01224mm, mean media-adventitia error: 0.020933 ± 0.01539mm and mean IMT error: 0.01063 ± 0.0031mm. Our system's Precision of Merit is: 98.23%, coefficient of correlation between automated and Reader's IMT is: 0.998 (p-value < 0.0001). These numbers are improved compared to previous publications by Suri's group which is automated multi-resolution conventional cIMT. CONCLUSIONS: Our fully automated bulb detection system reports 92.67% precision against ideal bulb edge locations as marked by the reader in the bulb transition zone.


Assuntos
Automação , Espessura Intima-Media Carotídea , Acidente Vascular Cerebral/epidemiologia , Sistemas de Gerenciamento de Base de Dados , Humanos , Reprodutibilidade dos Testes , Medição de Risco
2.
J Med Syst ; 40(4): 91, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26860914

RESUMO

Embedding of diagnostic and health care information requires secure encryption and watermarking. This research paper presents a comprehensive study for the behavior of some well established watermarking algorithms in frequency domain for the preservation of stroke-based diagnostic parameters. Two different sets of watermarking algorithms namely: two correlation-based (binary logo hiding) and two singular value decomposition (SVD)-based (gray logo hiding) watermarking algorithms are used for embedding ownership logo. The diagnostic parameters in atherosclerotic plaque ultrasound video are namely: (a) bulb identification and recognition which consists of identifying the bulb edge points in far and near carotid walls; (b) carotid bulb diameter; and (c) carotid lumen thickness all along the carotid artery. The tested data set consists of carotid atherosclerotic movies taken under IRB protocol from University of Indiana Hospital, USA-AtheroPoint™ (Roseville, CA, USA) joint pilot study. ROC (receiver operating characteristic) analysis was performed on the bulb detection process that showed an accuracy and sensitivity of 100 % each, respectively. The diagnostic preservation (DPsystem) for SVD-based approach was above 99 % with PSNR (Peak signal-to-noise ratio) above 41, ensuring the retention of diagnostic parameter devalorization as an effect of watermarking. Thus, the fully automated proposed system proved to be an efficient method for watermarking the atherosclerotic ultrasound video for stroke application.


Assuntos
Algoritmos , Artérias Carótidas/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Telemedicina/métodos , Segurança Computacional , Humanos , Razão Sinal-Ruído , Ultrassonografia
3.
Ultrasound Med Biol ; 41(5): 1247-62, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25638311

RESUMO

Described here is a detailed novel pilot study on whether the SYNTAX (Synergy between percutaneous coronary intervention with TAXUS and cardiac surgery) score, a measure of coronary artery disease complexity, could be better predicted with carotid intima-media thickness (cIMT) measures using automated IMT all along the common carotid and bulb plaque compared with manual IMT determined by sonographers. Three hundred seventy consecutive patients who underwent carotid ultrasound and coronary angiography were analyzed. SYNTAX score was determined from coronary angiograms by two experienced interventional cardiologists. Unlike most methods of cIMT measurement commonly used by sonographers, our method involves a computerized automated cIMT measurement all along the carotid artery that includes the bulb region and the region proximal to the bulb (under the class of AtheroEdge systems from AtheroPoint, Roseville, CA, USA). In this study, the correlation between automated cIMT that includes bulb plaque and SYNTAX score was found to be 0.467 (p < 0.0001), compared with 0.391 (p < 0.0001) for the correlation between the sonographer's IMT reading and SYNTAX score. The correlation between the automated cIMT and the sonographer's IMT was 0.882. When compared against the radiologist's manual tracings, automated cIMT system performance had a lumen-intima error of 0.007818 ± 0.0071 mm, media-adventitia error of 0.0179 ± 0.0125 mm and automated cIMT error of 0.0099 ± 0.00988 mm. The precision of automated cIMT against the manual radiologist's reading was 98.86%. This current automated algorithm revealed a significantly stronger correlation between cIMT and coronary SYNTAX score as compared with the sonographer's cIMT measurements with multiple cardiovascular risk factors. We benchmarked our correlation between the automated cIMT that includes bulb plaque and SYNTAX score against a previously published (Ikeda et al. 2013) AtheroEdgeLink (AtheroPoint) correlation between the automated cIMT that does not include bulb plaque and SYNTAX score and had an improvement of 44.58%. By sampling cIMT in the bulb region, the automated cIMT technique improves the degree of correlation between coronary artery disease lesion complexity and carotid atherosclerosis characteristics.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ecocardiografia/métodos , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA