Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dev Neurorehabil ; 26(4): 234-243, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36949659

RESUMO

In this study, the feasibility of Action Observation Training (AOT) in combination with sensor-based measurements in infants at high risk of Unilateral Spastic Cerebral Palsy (UCP) were evaluated. Over a four-week period, eight infants at high risk of UCP performed AOT at home while wearing sensors with assistance of caregivers. Sensor data were compared to clinical assessments of upper limb function, the Hand Assessment for Infants (HAI) and the Mini-Assisting Hand Assessment (Mini-AHA). AOT training time and acceptance by the caregivers were considered as indicators for feasibility. The excellent training adherence and positive feedback of the caregivers showed that the AOT was feasible in this patient group and setting. Sensor measurements were accepted and displayed significant correlations with hand function. These preliminary results indicate the potential of wearable sensors to record upper limb function over the course of AOT for infants at high risk of UCP. Thus, AOT in combination with sensor measurements are proposed as a feasible training tool to complement usual care.


Assuntos
Paralisia Cerebral , Extremidade Superior , Humanos , Lactente , Estudos de Viabilidade , Mãos , Encéfalo
2.
NPJ Digit Med ; 5(1): 116, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-35974156

RESUMO

Using connected sensing devices to remotely monitor health is a promising way to help transition healthcare from a rather reactive to a more precision medicine oriented proactive approach, which could be particularly relevant in the face of rapid population ageing and the challenges it poses to healthcare systems. Sensor derived digital measures of health, such as digital biomarkers or digital clinical outcome assessments, may be used to monitor health status or the risk of adverse events like falls. Current research around such digital measures has largely focused on exploring the use of few individual measures obtained through mobile devices. However, especially for long-term applications in older adults, this choice of technology may not be ideal and could further add to the digital divide. Moreover, large-scale systems biology approaches, like genomics, have already proven beneficial in precision medicine, making it plausible that the same could also hold for remote-health monitoring. In this context, we introduce and describe a zero-interaction digital exhaust: a set of 1268 digital measures that cover large parts of a person's activity, behavior and physiology. Making this approach more inclusive of older adults, we base this set entirely on contactless, zero-interaction sensing technologies. Applying the resulting digital exhaust to real-world data, we then demonstrate the possibility to create multiple ageing relevant digital clinical outcome assessments. Paired with modern machine learning, we find these assessments to be surprisingly powerful and often on-par with mobile approaches. Lastly, we highlight the possibility to discover novel digital biomarkers based on this large-scale approach.

3.
Sensors (Basel) ; 22(7)2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-35408381

RESUMO

With growing use of machine learning algorithms and big data in health applications, digital measures, such as digital biomarkers, have become highly relevant in digital health. In this paper, we focus on one important use case, the long-term continuous monitoring of cognitive ability in older adults. Cognitive ability is a factor both for long-term monitoring of people living alone as well as a relevant outcome in clinical studies. In this work, we propose a new potential digital biomarker for cognitive abilities based on location eigenbehaviour obtained from contactless ambient sensors. Indoor location information obtained from passive infrared sensors is used to build a location matrix covering several weeks of measurement. Based on the eigenvectors of this matrix, the reconstruction error is calculated for various numbers of used eigenvectors. The reconstruction error in turn is used to predict cognitive ability scores collected at baseline, using linear regression. Additionally, classification of normal versus pathological cognition level is performed using a support-vector machine. Prediction performance is strong for high levels of cognitive ability but grows weaker for low levels of cognitive ability. Classification into normal and older adults with mild cognitive impairment, using age and the reconstruction error, shows high discriminative performance with an ROC AUC of 0.94. This is an improvement of 0.08 as compared with a classification with age only. Due to the unobtrusive method of measurement, this potential digital biomarker of cognitive ability can be obtained entirely unobtrusively-it does not impose any patient burden. In conclusion, the usage of the reconstruction error is a strong potential digital biomarker for binary classification and, to a lesser extent, for more detailed prediction of inter-individual differences in cognition.


Assuntos
Disfunção Cognitiva , Fragilidade , Idoso , Biomarcadores , Cognição , Disfunção Cognitiva/diagnóstico , Humanos , Aprendizado de Máquina
4.
Sensors (Basel) ; 22(4)2022 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-35214560

RESUMO

For patients suffering from neurodegenerative disorders, the behavior and activities of daily living are an indicator of a change in health status, and home-monitoring over a prolonged period of time by unobtrusive sensors is a promising technology to foster independent living and maintain quality of life. The aim of this pilot case study was the development of a multi-sensor system in an apartment to unobtrusively monitor patients at home during the day and night. The developed system is based on unobtrusive sensors using basic technologies and gold-standard medical devices measuring physiological (e.g., mobile electrocardiogram), movement (e.g., motion tracking system), and environmental parameters (e.g., temperature). The system was evaluated during one session by a healthy 32-year-old male, and results showed that the sensor system measured accurately during the participant's stay. Furthermore, the participant did not report any negative experiences. Overall, the multi-sensor system has great potential to bridge the gap between laboratories and older adults' homes and thus for a deep and novel understanding of human behavioral and neurological disorders. Finally, this new understanding could be utilized to develop new algorithms and sensor systems to address problems and increase the quality of life of our aging society and patients with neurological disorders.


Assuntos
Atividades Cotidianas , Qualidade de Vida , Adulto , Idoso , Humanos , Vida Independente , Masculino , Monitorização Fisiológica , Projetos Piloto
5.
IEEE J Biomed Health Inform ; 26(4): 1560-1569, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34550895

RESUMO

Modern sensor technology is increasingly used in older adults to not only provide additional safety but also to monitor health status, often by means of sensor derived digital measures or biomarkers. Social isolation is a known risk factor for late-life depression, and a potential component of social-isolation is the lack of home visits. Therefore, home visits may serve as a digital measure for social isolation and late-life depression. Late-life depression is a common mental and emotional disorder in the growing population of older adults. The disorder, if untreated, can significantly decrease quality of life and, amongst other effects, leads to increased mortality. Late-life depression often goes undiagnosed due to associated stigma and the incorrect assumption that it is a normal part of ageing. In this work, we propose a visit detection system that generalizes well to previously unseen apartments - which may differ largely in layout, sensor placement, and size from apartments found in the semi-annotated training dataset. We find that by using a self-training-based domain adaptation strategy, a robust system to extract home visit information can be built (ROC AUC = 0.773). We further show that the resulting visit information correlates well with the common geriatric depression scale screening tool ( ρ = -0.87, p = 0.001), providing further support for the idea of utilizing the extracted information as a potential digital measure or even as a digital biomarker to monitor the risk of late-life depression.


Assuntos
Depressão , Qualidade de Vida , Idoso , Envelhecimento , Biomarcadores , Depressão/diagnóstico , Depressão/epidemiologia , Nível de Saúde , Humanos
6.
Sensors (Basel) ; 21(18)2021 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-34577412

RESUMO

Gait analysis is an important part of assessments for a variety of health conditions, specifically neurodegenerative diseases. Currently, most methods for gait assessment are based on manual scoring of certain tasks or restrictive technologies. We present an unobtrusive sensor system based on light detection and ranging sensor technology for use in home-like environments. In our evaluation, we compared six different gait parameters, based on recordings from 25 different people performing eight different walks each, resulting in 200 unique measurements. We compared the proposed sensor system against two state-of-the art technologies, a pressure mat and a set of inertial measurement unit sensors. In addition to test usability and long-term measurement, multi-hour recordings were conducted. Our evaluation showed very high correlation (r>0.95) with the gold standards across all assessed gait parameters except for cycle time (r=0.91). Similarly, the coefficient of determination was high (R2>0.9) for all gait parameters except cycle time. The highest correlation was achieved for stride length and velocity (r≥0.98,R2≥0.95). Furthermore, the multi-hour recordings did not show the systematic drift of measurements over time. Overall, the unobtrusive gait measurement system allows for contactless, highly accurate long- and short-term assessments of gait in home-like environments.


Assuntos
Análise da Marcha , Marcha , Humanos
7.
JMIR Mhealth Uhealth ; 9(6): e24666, 2021 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-34114966

RESUMO

BACKGROUND: Population aging is posing multiple social and economic challenges to society. One such challenge is the social and economic burden related to increased health care expenditure caused by early institutionalizations. The use of modern pervasive computing technology makes it possible to continuously monitor the health status of community-dwelling older adults at home. Early detection of health issues through these technologies may allow for reduced treatment costs and initiation of targeted preventive measures leading to better health outcomes. Sleep is a key factor when it comes to overall health and many health issues manifest themselves with associated sleep deteriorations. Sleep quality and sleep disorders such as sleep apnea syndrome have been extensively studied using various wearable devices at home or in the setting of sleep laboratories. However, little research has been conducted evaluating the potential of contactless and continuous sleep monitoring in detecting early signs of health problems in community-dwelling older adults. OBJECTIVE: In this work we aim to evaluate which contactlessly measurable sleep parameter is best suited to monitor perceived and actual health status changes in older adults. METHODS: We analyzed real-world longitudinal (up to 1 year) data from 37 community-dwelling older adults including more than 6000 nights of measured sleep. Sleep parameters were recorded by a pressure sensor placed beneath the mattress, and corresponding health status information was acquired through weekly questionnaires and reports by health care personnel. A total of 20 sleep parameters were analyzed, including common sleep metrics such as sleep efficiency, sleep onset delay, and sleep stages but also vital signs in the form of heart and breathing rate as well as movements in bed. Association with self-reported health, evaluated by EuroQol visual analog scale (EQ-VAS) ratings, were quantitatively evaluated using individual linear mixed-effects models. Translation to objective, real-world health incidents was investigated through manual retrospective case-by-case analysis. RESULTS: Using EQ-VAS rating based self-reported perceived health, we identified body movements in bed-measured by the number toss-and-turn events-as the most predictive sleep parameter (t score=-0.435, P value [adj]=<.001). Case-by-case analysis further substantiated this finding, showing that increases in number of body movements could often be explained by reported health incidents. Real world incidents included heart failure, hypertension, abdominal tumor, seasonal flu, gastrointestinal problems, and urinary tract infection. CONCLUSIONS: Our results suggest that nightly body movements in bed could potentially be a highly relevant as well as easy to interpret and derive digital biomarker to monitor a wide range of health deteriorations in older adults. As such, it could help in detecting health deteriorations early on and provide timelier, more personalized, and precise treatment options.


Assuntos
Vida Independente , Sono , Idoso , Diagnóstico Precoce , Humanos , Polissonografia , Estudos Retrospectivos
8.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 5826-5830, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33019299

RESUMO

Pervasive computing based home-monitoring has attracted increasing interest over the past years, especially regarding applications in the growing population of older adults. Applications include safety, monitoring chronic conditions like dementia, or providing preventive information about changes in health and behavior. Commonly used components of such systems are inexpensive and low-power passive infrared motion sensing units, usually placed in distinct locations of an older adult's apartment. To efficiently analyse the resulting data the majority of procedures expect the resulting sensor data to be encoded in a vector space. However, most common vector space encodings are based on orthogonal representations of the sensor locations and thus lead to loss of information as the sensors are placed in a 3D-space. In this work we introduce an embedding of sensor-locations in a 2D-space based on multidimensional scaling, without knowledge of the physical position of the sensors. We evaluate this embedding, using two different algorithms and compare it to commonly used baselines in different tasks. All evaluations are carried out on a real-world home-monitoring data-set.


Assuntos
Algoritmos
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 5858-5962, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33019306

RESUMO

In recent years, consumer-grade sensors that measure health relevant physiological signals have become widely available and are increasingly used by consumers and researchers alike. While this allows for multiple novel, potentially highly beneficial, large-scale health monitoring applications, quality of these data streams is oftentimes suboptimal. This makes alignment of different high-frequency data streams from multiple, non-connected sensors, a difficult task. In this work we describe a noise-robust framework to align high-frequency signals from different sensors, that share some underlying characteristic, obtained in a free-living, non-clinical, home environment. We demonstrate the approach on the basis of a single-lead, medical-grade, mobile electrocardiography device and a consumer-grade sleep sensor that allows for ballistocardiography. Both commercially available sensors measure the physiological process of a heartbeat. We show, on the basis of real-world data with multiple people and sensors, that the two highly noisy and sometimes dissimilar signals could in most cases be aligned with considerable precision. As a result, we could reduce mean heartbeat peak-to-peak difference by 58.1% on average and increase signal correlation by 0.40 on average.


Assuntos
Balistocardiografia , Processamento de Sinais Assistido por Computador , Vacina BCG , Eletrocardiografia , Frequência Cardíaca
10.
Front Cardiovasc Med ; 7: 110, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32760739

RESUMO

Background: Home monitoring sensor systems are increasingly used to monitor seniors in their apartments for detection of emergency situations. The aim of this study was to deliver a proof-of-concept for the use of multimodal sensor systems with pervasive computing technology for the detection of clinically relevant health problems over longer time periods. Methods: Data were collected with a longitudinal home monitoring study in Switzerland (StrongAge Cohort Study) in a cohort of 24 old and oldest-old, community-dwelling adults over a period of 1 to 2 years. Physical activity in the apartment, toilet visits, refrigerator use, and entrance door openings were quantified using a commercially available passive infrared motion sensing system (Domosafety S.A., Switzerland). Heart rate, respiration rate, and sleep quality were recorded with the commercially available EMFIT QS bed sensor device (Emfit Ltd., Finland). Vital signs and contextual data were collected using a wearable sensor on the upper arm (Everion, Biovotion, Switzerland). Sensor data were correlated with health-related data collected from the weekly visits of the seniors by health professionals, including information about physical, psychological, cognitive, and behavior status, health problems, diseases, medication, and medical diagnoses. Results: Twenty of the 24 recruited participants (age 88.9 ± 7.5 years, 79% females) completed the study; two participants had to stop their study participation because of severe health deterioration, whereas two participants died during the course of the study. A history of chronic disease was present in 12/24 seniors, including heart failure, heart rhythm disturbances, pulmonary embolism, severe insulin-dependent diabetes, and Parkinson's disease. In total, 242,232 person-hours were recorded. During the monitoring period, 963 health status records were reported and repeated clinical assessments of aging-relevant indicators and outcomes were performed. Several episodes of health deterioration, including heart failure worsening and heart rhythm disturbances, could be captured by sensor signals from different sources. Conclusions: Our results indicate that monitoring of seniors with a multimodal sensor and pervasive computing system over longer time periods is feasible and well-accepted, with a great potential for detection of health deterioration. Further studies are necessary to evaluate the full range of the clinical potential of these findings.

11.
Front Aging Neurosci ; 12: 87, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32372942

RESUMO

There is currently a need for engaging, user-friendly, and repeatable tasks for assessment of cognitive and motor function in aging and neurodegenerative diseases. This study evaluated the feasibility of a maze-like Numberlink puzzle game in assessing differences in game-based measures of cognition and motor function due to age and neurodegenerative diseases. Fifty-five participants, including young (18-31 years, n = 18), older (64-79 years, n = 14), and oldest adults (86-98 years, n = 14), and patients with Parkinson's (59-76 years, n = 4) and Huntington's disease (HD; 35-66 years, n = 5) played different difficulty levels of the Numberlink puzzle game and completed usability questionnaires and tests for psychomotor, attentional, visuospatial, and constructional and executive function. Analyses of Numberlink game-based cognitive (solving time and errors) and motor [mean velocity and movement direction changes (MDC)] performance metrics revealed statistically significant differences between age groups and between patients with HD and older adults. However, patients with Parkinson's disease (PD) did not differ from older adults. Correlational analyses showed significant associations between game-based performance and movement metrics and performance on neuropsychological tests for psychomotor, attentional, visuospatial, and constructional and executive function. Furthermore, varying characteristics of the Numberlink puzzle game succeeded in creating graded difficulty levels. Findings from this study support recent suggestions that data from a maze-like puzzle game provide potential "digital biomarkers" to assess changes in psychomotor, visuoconstructional, and executive function related to aging and neurodegeneration. In particular, game-based movement measures from the maze-like puzzle Numberlink games are promising as a tool to monitor the progression of motor impairment in neurodegenerative diseases. Further studies are needed to more comprehensively establish the cognitive validity and test-retest reliability of using Numberlink puzzles as a valid cognitive assessment tool.

12.
Front Digit Health ; 2: 566595, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-34713038

RESUMO

Passive infrared motion sensors are commonly used in telemonitoring applications to monitor older community-dwelling adults at risk. One possible use case is quantification of in-home physical activity, a key factor and potential digital biomarker for healthy and independent aging. A major disadvantage of passive infrared sensors is their lack of performance and comparability in physical activity quantification. In this work, we calibrate passive infrared motion sensors for in-home physical activity quantification with simultaneously acquired data from wearable accelerometers and use the data to find a suitable correlation between in-home and out-of-home physical activity. We use data from 20 community-dwelling older adults that were simultaneously provided with wireless passive infrared motion sensors in their homes, and a wearable accelerometer for at least 60 days. We applied multiple calibration algorithms and evaluated results based on several statistical and clinical metrics. We found that using even relatively small amounts of wearable based ground-truth data over 7-14 days, passive infrared based wireless sensor systems can be calibrated to give largely better estimates of older adults' daily physical activity. This increase in performance translates directly to stronger correlations of measured physical activity levels with a variety of age relevant health indicators and outcomes known to be associated with physical activity.

13.
Sensors (Basel) ; 19(23)2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31779108

RESUMO

Parkinson's disease (PD) is characterized by a highly individual disease-profile as well as fluctuating symptoms. Consequently, 24-h home monitoring in a real-world environment would be an ideal solution for precise symptom diagnostics. In recent years, small lightweight sensors which have assisted in objective, reliable analysis of motor symptoms have attracted a lot of attention. While technical advances are important, patient acceptance of such new systems is just as crucial to increase long-term adherence. So far, there has been a lack of long-term evaluations of PD-patient sensor adherence and acceptance. In a pilot study of PD patients (N = 4), adherence (wearing time) and acceptance (questionnaires) of a multi-part sensor set was evaluated over a 4-week timespan. The evaluated sensor set consisted of 3 body-worn sensors and 7 at-home installed ambient sensors. After one month of continuous monitoring, the overall system usability scale (SUS)-questionnaire score was 71.5%, with an average acceptance score of 87% for the body-worn sensors and 100% for the ambient sensors. On average, sensors were worn 15 h and 4 min per day. All patients reported strong preferences of the sensor set over manual self-reporting methods. Our results coincide with measured high adherence and acceptance rate of similar short-term studies and extend them to long-term monitoring.


Assuntos
Monitorização Ambulatorial/métodos , Doença de Parkinson/fisiopatologia , Idoso , Feminino , Humanos , Masculino , Projetos Piloto , Inquéritos e Questionários , Tecnologia/métodos
14.
Sci Rep ; 9(1): 9662, 2019 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-31273234

RESUMO

In older adults, physical activity is crucial for healthy aging and associated with numerous health indicators and outcomes. Regular assessments of physical activity can help detect early health-related changes and manage physical activity targeted interventions. The quantification of physical activity, however, is difficult as commonly used self-reported measures are biased and rather unprecise point in time measurements. Modern alternatives are commonly based on wearable technologies which are accurate but suffer from usability and compliance issues. In this study, we assessed the potential of an unobtrusive ambient-sensor based system for continuous, long-term physical activity quantification. Towards this goal, we analysed one year of longitudinal sensor- and medical-records stemming from thirteen community-dwelling old and oldest old subjects. Based on the sensor data the daily number of room-transitions as well as the raw sensor activity were calculated. We did find the number of room-transitions, and to some degree also the raw sensor activity, to capture numerous known associations of physical activity with cognitive, well-being and motor health indicators and outcomes. The results of this study indicate that such low-cost unobtrusive ambient-sensor systems can provide an adequate approximation of older adults' overall physical activity, sufficient to capture relevant associations with health indicators and outcomes.


Assuntos
Exercício Físico , Avaliação Geriátrica/métodos , Vida Independente/estatística & dados numéricos , Autorrelato , Dispositivos Eletrônicos Vestíveis/estatística & dados numéricos , Idoso de 80 Anos ou mais , Feminino , Humanos , Estudos Longitudinais , Masculino , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA