Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37462612

RESUMO

OBJECTIVES: We report 1-year safety and clinical outcomes in patients <60 years undergoing bioprosthetic surgical aortic valve intervention. METHODS: The INSPIRIS RESILIA Durability Registry is a prospective, multicentre registry to assess clinical outcomes of patients <60 years. Patients with planned SAVR with or without concomitant replacement of the ascending aorta and/or coronary bypass surgery were included. Time-related valve safety, haemodynamic performance and quality of life (QoL) at 1 year were assessed. RESULTS: A total of 421 patients were documented with a mean age of 53.5 years, 76.5% being male and 27.2% in NYHA class III/IV. Outcomes within 30 days included cardiovascular-related mortality (0.7%), time-related valve safety (VARC-2; 5.8%), thromboembolic events (1.7%), valve-related life-threatening bleeding (VARC-2; 4.3%) and permanent pacemaker implantation (3.8%). QoL was significantly increased at 6 months and sustained at 1 year. Freedom from all-cause mortality at 1 year was 98.3% (95% confidence interval 97.1; 99.6) and 81.8% were NYHA I versus 21.9% at baseline. No patient developed structural valve deterioration stage 3 (VARC-3). The mean aortic pressure gradient was 12.6 mmHg at 1 year and the effective orifice area was 1.9 cm2. CONCLUSIONS: The 1-year data from the INSPIRIS RESILIA valve demonstrate good safety and excellent haemodynamic performance as well as an early QoL improvement. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov: NCT03666741.

2.
J Cardiothorac Surg ; 16(1): 51, 2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33766089

RESUMO

BACKGROUND: Degenerative aortic valve disease accounts for 10-20% of all cardiac surgical procedures. The impact of pre-existing comorbidities on the outcome of patients undergoing surgical aortic valve replacement (SAVR) needs further research. METHODS: The IMPACT registry is a non-interventional, prospective, open-label, multicenter, international registry with a follow-up of 5 years to assess the impact of pre-existing comorbidities of patients undergoing SAVR with the INSPIRIS RESILIA aortic valve on outcomes. IMPACT will be conducted across 25 sites in Austria, Germany, The Netherlands and Switzerland and intends to enroll approximately 500 patients. Patients will be included if they are at least 18 years of age and are scheduled to undergo SAVR with the INSPIRIS RESILIA Aortic Valve with or without concomitant ascending aortic root replacement and/or coronary bypass surgery. The primary objective is to determine all-cause mortality at 1, 3, and 5 years post SAVR. Secondary objectives include cardiac-related and valve-related mortality and structural valve deterioration including hemodynamics and durability, valve performance and further clinical outcomes in the overall study population and in specific patient subgroups characterized by the presence of chronic kidney disease, hypertension, metabolic syndrome and/or chronic inflammation. DISCUSSION: IMPACT is a prospective, multicenter European registry, which will provide much-needed data on the impact of pre-existing comorbidities on patient outcomes and prosthetic valve performance, and in particular the performance of the INSPIRIS RESILIA, in a real-world setting. The findings of this study may help to support and expand appropriate patient selection for treatment with bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT04053088 .


Assuntos
Estenose da Valva Aórtica/cirurgia , Comorbidade , Implante de Prótese de Valva Cardíaca , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Bioprótese , Ponte de Artéria Coronária , Feminino , Alemanha , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Inflamação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Projetos de Pesquisa , Resultado do Tratamento
3.
Blood Press Monit ; 26(4): 292-298, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33741775

RESUMO

OBJECTIVE: The aim of the present study was to validate the blood pressure (BP) monitor Beurer BM 28 according to the International Protocol of the European Society of Hypertension (ESH-IP) revision 2010. METHODS: In 33 subjects of age 27-81 years, BP measurements were performed according to the ESH-IP protocol, which alternates reference mercury sphygmomanometer and device-under-test (Beurer BM 28) measurements, resulting in a total of 99 comparisons. RESULTS: As to part 1 of the protocol, an absolute difference within 5 mmHg between the Beurer BM 28 and the test device was found in 83 out of 99 comparisons for the SBP and 82 out of 99 comparisons for the DBP. In 95 out of 99 SBP comparisons and 96 out of 99 DBP comparisons, the difference was found to be within 10 mmHg, whereas only one outlier was noted with an SBP difference higher than 15 mmHg. Mean difference between the test device and the reference was 0.4 ± 4.4 mmHg for SBP, and 0.5 ± 4.3 mmHg for DBP. According to part 2 of the protocol, 30 out of 33 subjects for SBP, and 28 out of 33 for DBP had a minimum of two out of three comparisons staying within the range of 5 mmHg. In none of the subjects, all three comparisons stayed outside the 5 mmHg absolute difference, while in three subjects this was the case for the DBP. CONCLUSION: The Beurer BM 28 met all requirements of the ESH-IP revision 2010 and can be recommended for BP measurements in the study population under investigation.


Assuntos
Monitores de Pressão Arterial , Hipertensão , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Determinação da Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial , Humanos , Hipertensão/diagnóstico , Pessoa de Meia-Idade , Esfigmomanômetros
4.
Blood Press Monit ; 26(4): 299-304, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33734119

RESUMO

OBJECTIVE: Aim of this study was to validate the Microlife BP B3 AFIB/enterprise resource planning (ERP) No: BP3KT1-3 N blood pressure (BP) monitor according to the American National Standards Institute (ANSI)/Association for the Advancement of Medical Instrumentation (AAMI)/International Organization for Standardization (ISO) 81060-2:2019 in adolescents and adults from a general population. METHODS: BP measurements on the upper arm were performed in 85 subjects (age range 12-88 years), using the Microlife BP B3 AFIB and a standard mercury reference sphygmomanometer. RESULTS: A total of 255 valid BP comparisons were performed for the present validation analysis. The mean ± SD difference between the test and the reference device was 0.70 ± 7.05 mmHg for SBP (pass criterion ≤5 mmHg) and -0.85 ± 4.70 mmHg for DBP (pass criterion ≤5 mmHg) with the SD below the required value of ≤8 mmHg. The mean ± SD of the intraindividual differences between the test and the reference device was 0.70 ± 5.87 mmHg for SBP (pass criterion for the SD ≤6.90 mmHg) and -0.85 ± 4.19 mmHg for DBP (pass criterion for the SD ≤6.88 mmHg). CONCLUSION: The Microlife BP B3 AFIB/ERP No: BP3KT1-3 N has passed the criteria of the ANSI/AAMI/ISO 81060-2:2019 protocol and can be recommended for home BP measurements in adolescents and adults.


Assuntos
Fibrilação Atrial , Monitores de Pressão Arterial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Braço , Pressão Sanguínea , Determinação da Pressão Arterial , Criança , Humanos , Pessoa de Meia-Idade , Padrões de Referência , Esfigmomanômetros , Adulto Jovem
5.
J Cardiothorac Surg ; 15(1): 119, 2020 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-32460798

RESUMO

BACKGROUND: There is an ever-growing number of patients requiring aortic valve replacement (AVR). Limited data is available on the long-term outcomes and structural integrity of bioprosthetic valves in younger patients undergoing surgical AVR. METHODS: The INSPIRIS RESILIA Durability Registry (INDURE) is a prospective, open-label, multicentre, international registry with a follow-up of 5 years to assess clinical outcomes of patients younger than 60 years who undergo surgical AVR using the INSPIRIS RESILIA aortic valve. INDURE will be conducted across 20-22 sites in Europe and Canada and intends to enrol minimum of 400 patients. Patients will be included if they are scheduled to undergo AVR with or without concomitant root replacement and/or coronary bypass surgery. The primary objectives are to 1) determine VARC-2 defined time-related valve safety at one-year (depicted as freedom from events) and 2) determine freedom from stage 3 structural valve degeneration (SVD) presenting as morphological abnormalities and severe haemodynamic valve degeneration at 5 years. Secondary objectives include the assessment of the haemodynamic performance of the valve, all stages of SVD, potential valve-in-valve procedures, clinical outcomes (in terms of New York Heart Association [NYHA] function class and freedom from valve-related rehospitalisation) and change in patient quality-of-life. DISCUSSION: INDURE is a prospective, multicentre registry in Europe and Canada, which will provide much needed data on the long-term performance of bioprosthetic valves in general and the INSPIRIS RESILIA valve in particular. The data may help to gather a deeper understanding of the longevity of bioprosthetic valves and may expand the use of bioprosthetic valves in patients under the age of 60 years. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03666741 (registration received September, 12th, 2018).


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Sistema de Registros , Canadá , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...