Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Biochem ; 689: 115482, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342199

RESUMO

Simulated SV-AUC data for an adeno-associated virus (AAV) sample consisting of four components having closely spaced sedimentation coefficients were used to develop a high-speed protocol that optimized the size distribution analysis resolution. The resulting high speed (45K rpm) SV-AUC (hs-SV-AUC) protocol poses several experimental challenges: 1) the need for rapid data acquisition, 2) increased potential for optical artifacts from steep and fast moving boundaries and 3) the increased potential for convection. To overcome these challenges the protocol uses interference detection at low temperatures and data that are confined to a limited radial-time window. In addition to providing higher resolution AAV SV-AUC data and very short run times (<20 min after temperature equilibration), the need to match the sample and reference solvent composition and meniscus positions is relaxed making interference detection as simple to employ as absorbance detection. Finally, experimental data comparing hs-SV-AUC (at 45K rpm) with standard low-speed (15K rpm) SV-AUC on the same AAV sample demonstrate the size distribution resolution improvement. These experiments also validate the use of a radial-time window and show how quickly data can be acquired using the hs-SV-AUC protocol.


Assuntos
Temperatura Baixa , Dependovirus , Dependovirus/genética , Área Sob a Curva , Ultracentrifugação/métodos , Temperatura
2.
J Pharm Sci ; 113(5): 1401-1414, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38220088

RESUMO

Silicone oil is a commonly used lubricant in pre-filled syringes (PFSs) and can migrate over time into solution in the form of silicone oil particles (SiOPs). The presence of these SiOPs can result in elevated subvisible particle counts in PFS drug products compared to other drug presentations such as vials or cartridges. Their presence in products presents analytical challenges as they complicate quantitation and characterization of other types of subvisible particles in solution. Previous studies have suggested that they can potentially act as adjuvant resulting in potential safety risks for patients. In this paper we present several analytical case studies describing the impact of the presence of SiOPs in biotherapeutics on the analysis of the drug as well as clinical case studies examining the effect of SiOPs on patient safety. The analytical case studies demonstrate that orthogonal techniques, especially flow imaging, can help differentiate SiOPs from other types of particulate matter. The clinical case studies showed no difference in the observed patient safety profile across multiple drugs, patient populations, and routes of administration, indicating that the presence of SiOPs does not impact patient safety.


Assuntos
Produtos Biológicos , Óleos de Silicone , Humanos , Óleos de Silicone/análise , Tamanho da Partícula , Preparações Farmacêuticas , Material Particulado , Seringas
3.
Anal Chem ; 95(44): 16138-16143, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37874938

RESUMO

The resolution of flow field-flow fractionation (flow FFF) depends primarily on the crossflow rate and its change over time. In this work, we demonstrate a method for modulation of the crossflow rate during separation that increases the peak-to-peak resolution of the resulting fractograms. In classical FFF methods, the crossflow rate is either maintained constant or decreased during the separation of the different species. In this work, higher resolution between peaks was achieved by a novel gradient method in which the crossflow is increased briefly during separation to allow stronger retention of the later eluting peaks. We first outline the theoretical basis by which improved separation is achieved. We confirm our hypothesis by quantifying the impact of increasing crossflow on the resolution between a monoclonal antibody monomer and its high-molecular-weight aggregate. We then demonstrate that this method is applicable to two different FFF methods (AF4 and HF5) and various pharmaceutically relevant samples (monoclonal antibodies and adeno-associated viruses). Finally, we hypothesize that increasing the force perpendicular to the laminar flow as described here is broadly applicable to all FFF methods and improves the quality of FFF-based separations.


Assuntos
Fracionamento por Campo e Fluxo , Fracionamento por Campo e Fluxo/métodos , Anticorpos Monoclonais , Peso Molecular , Gravitação
4.
Analyst ; 148(21): 5361-5365, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37755232

RESUMO

Stereochemical comparability is critical for ensuring manufacturing consistency in therapeutic phosphorothioate oligonucleotides. Currently, analytical methods for this assessment are limited. We hereby report on a novel protocol capable of detecting a stereochemistry change in a single phosphorothioate linkage by employing nuclease P1 digestion of the oligonucleotide with subsequent LCMS analysis of the resulting fragments. The method proves valuable for establishing stereochemical comparability and for ensuring manufacturing consistency of oligonucleotide therapeutics.

5.
AAPS PharmSciTech ; 24(1): 18, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36526853

RESUMO

Visible protein-like particle standards may improve visual inspection and/or appearance testing practices used in the biotechnology industry. They may improve assay performance resulting in better alignment and more standardized training among different companies. The National Institute of Standards and Technology (NIST) has conducted an interlaboratory study to test whether the standards under development mimic typical proteinaceous particles found in biotherapeutics and if they can be implemented during the visual inspection process. Fourteen organizations from industry and government have participated. A total of 20 labs from these 14 organizations participated with analysts from 6 formulation, 7 analytical, 4 quality control, and 3 manufacturing labs. The circulated samples consisted of abraded ethylene tetrafluoroethylene (ETFE) particles or photolithographic particles. The results consist of qualitative ratings, which varied substantially among organizations and within labs. Polydisperse ETFE particle suspensions, containing particles enriched in greater than 150 µm in size, were rated more favorably than the photolithographic particles by formulation and analytical scientists. The largest monodisperse photolithographic particles (approximately 300 µm in size) were favored equally compared to ETFE by all scientists. Solution modifications to decrease the settling rate or to alter optical properties of the ETFE solutions yielded lower ratings by the analysts. Both particle types received mixed ratings for their usability and for their application for visual inspection and for training purposes. Industry feedback will assist NIST in developing reference material(s) for visible protein-like particles.


Assuntos
Proteínas , Tamanho da Partícula , Padrões de Referência , Controle de Qualidade
6.
J Pharm Sci ; 111(7): 2121-2133, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34986360

RESUMO

Analytical ultracentrifugation (AUC) is a critical analytical tool supporting the development and manufacture of protein therapeutics. AUC is routinely used as an assay orthogonal to size exclusion chromatography for aggregate quantitation. This article distills the experimental and analysis procedures used by the authors for sedimentation velocity AUC into a series of best-practices considerations. The goal of this distillation is to help harmonize aggregate quantitation approaches across the biopharmaceutical industry. We review key considerations for sample and instrument suitability, experimental design, and data analysis best practices and conversely, highlight potential pitfalls to accurate aggregate analysis. Our goal is to provide experienced users benchmarks against which they can standardize their analyses and to provide guidance for new AUC analysts that will aid them to become proficient in this fundamental technique.


Assuntos
Anticorpos Monoclonais , Anticorpos Monoclonais/química , Cromatografia em Gel , Ultracentrifugação/métodos
7.
J Pharm Sci ; 109(1): 830-844, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31647951

RESUMO

One of the major product quality challenges for injectable biologics is controlling the amount of protein aggregates and particles present in the final drug product. This article focuses on particles in the submicron range (<2 µm). A cross-industry collaboration was undertaken to address some of the analytical gaps in measuring submicron particles (SMPs), developing best practices, and surveying the concentration of these particles present in 52 unique clinical and commercial protein therapeutics covering 62 dosage forms. Measured particle concentrations spanned a range of 4 orders of magnitude for nanoparticle tracking analysis and 3 orders of magnitude for resonant mass measurement. The particle concentrations determined by the 2 techniques differed significantly for both control and actual product. In addition, results suggest that these techniques exhibit higher variability compared to well-established subvisible particle characterization techniques (e.g., flow-imaging or light obscuration). Therefore, in their current states, nanoparticle tracking analysis and resonant mass measurement-based techniques can be used during product and process characterization, contributing information on the nature and propensity for formation of submicron particles and what is normal for the product, but may not be suitable for release or quality control testing. Evaluating the level of SMPs to which humans have been routinely exposed during the administration of several commercial and late-phase clinical products adds critical knowledge to our understanding of SMP levels that may be considered acceptable from a safety point of view. This article also discusses dependence of submicron particle size and concentration on the dosage form attributes such as physical state, primary packaging, dose strength, etc. To the best of our knowledge, this is the largest study ever conducted to characterize SMPs in late-phase and commercial products.


Assuntos
Nanotecnologia , Proteínas/química , Tecnologia Farmacêutica , Formas de Dosagem , Composição de Medicamentos , Estabilidade de Medicamentos , Europa (Continente) , Humanos , Nanopartículas , Tamanho da Partícula , Agregados Proteicos , Estabilidade Proteica , Reprodutibilidade dos Testes , Estados Unidos
8.
Hum Gene Ther Methods ; 30(4): 144-152, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31368356

RESUMO

Recombinant adeno-associated virus (rAAV)-mediated gene therapy is a fast-evolving field in the biotechnology industry. One of the major challenges in developing a purification process for AAV gene therapy is establishing an effective yet scalable method to remove empty capsids, or viral vectors lacking the therapeutic gene, from full capsids-viral product containing the therapeutic sequence. Several analytical methods that can quantify the empty-to-full capsid ratio have been reported in the literature. However, as samples can vary widely in viral titer, buffer matrix, and the relative level of empty capsids, understanding the specifications and limitations of different analytical methods is critical to providing appropriate support to facilitate process development. In this study, we developed a novel anion-exchange high-performance liquid chromatography assay to determine the empty-to-full capsid ratio of rAAV samples. The newly developed method demonstrated good comparability with both the transmission electron microscopy and analytical ultracentrifugation methods used in empty-to-full capsid ratio quantification, while providing much higher assay throughput and reducing the minimum sample concentration requirement to 2.7E11 viral genomes/mL.


Assuntos
Capsídeo , Dependovirus , Capsídeo/ultraestrutura , Cromatografia Líquida de Alta Pressão , Dependovirus/ultraestrutura , Terapia Genética , Microscopia Eletrônica de Transmissão
9.
Nat Methods ; 16(7): 595-602, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31249422

RESUMO

Hydrogen deuterium exchange mass spectrometry (HDX-MS) is a powerful biophysical technique being increasingly applied to a wide variety of problems. As the HDX-MS community continues to grow, adoption of best practices in data collection, analysis, presentation and interpretation will greatly enhance the accessibility of this technique to nonspecialists. Here we provide recommendations arising from community discussions emerging out of the first International Conference on Hydrogen-Exchange Mass Spectrometry (IC-HDX; 2017). It is meant to represent both a consensus viewpoint and an opportunity to stimulate further additions and refinements as the field advances.


Assuntos
Medição da Troca de Deutério/métodos , Espectrometria de Massas/métodos , Análise de Dados , Concentração de Íons de Hidrogênio
10.
Anal Chem ; 91(11): 7336-7345, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-31045344

RESUMO

Hydrogen-deuterium exchange mass spectrometry (HDX-MS) is an established, powerful tool for investigating protein-ligand interactions, protein folding, and protein dynamics. However, HDX-MS is still an emergent tool for quality control of biopharmaceuticals and for establishing dynamic similarity between a biosimilar and an innovator therapeutic. Because industry will conduct quality control and similarity measurements over a product lifetime and in multiple locations, an understanding of HDX-MS reproducibility is critical. To determine the reproducibility of continuous-labeling, bottom-up HDX-MS measurements, the present interlaboratory comparison project evaluated deuterium uptake data from the Fab fragment of NISTmAb reference material (PDB: 5K8A ) from 15 laboratories. Laboratories reported ∼89 800 centroid measurements for 430 proteolytic peptide sequences of the Fab fragment (∼78 900 centroids), giving ∼100% coverage, and ∼10 900 centroid measurements for 77 peptide sequences of the Fc fragment. Nearly half of peptide sequences are unique to the reporting laboratory, and only two sequences are reported by all laboratories. The majority of the laboratories (87%) exhibited centroid mass laboratory repeatability precisions of ⟨ sLab⟩ ≤ (0.15 ± 0.01) Da (1σx̅). All laboratories achieved ⟨sLab⟩ ≤ 0.4 Da. For immersions of protein at THDX = (3.6 to 25) °C and for D2O exchange times of tHDX = (30 s to 4 h) the reproducibility of back-exchange corrected, deuterium uptake measurements for the 15 laboratories is σreproducibility15 Laboratories( tHDX) = (9.0 ± 0.9) % (1σ). A nine laboratory cohort that immersed samples at THDX = 25 °C exhibited reproducibility of σreproducibility25C cohort( tHDX) = (6.5 ± 0.6) % for back-exchange corrected, deuterium uptake measurements.


Assuntos
Anticorpos Monoclonais/química , Espectrometria de Massa com Troca Hidrogênio-Deutério , Fragmentos Fab das Imunoglobulinas/análise
12.
J Am Soc Mass Spectrom ; 28(5): 840-849, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28194741

RESUMO

Introduction of a chemical change to one or more amino acids in a protein's polypeptide chain can result in various effects on its higher-order structure (HOS) and biophysical behavior (or properties). These effects range from no detectable change to significant structural or conformational alteration that can greatly affect the protein's biophysical properties and its resulting biological function. The ability to reliably detect the absence or presence of such changes is essential to understanding the structure-function relationship in a protein and in the successful commercial development of protein-based drugs (biopharmaceuticals). In this paper, we focus our attention on the latter by specifically elucidating the impact of oxidation on the HOS, structural dynamics, and biophysical properties of interferon beta-1a (IFNß-1a). Oxidation is a common biochemical modification that occurs in many biopharmaceuticals, specifically in two naturally-occurring sulfur-containing amino acids, methionine and cysteine. To carry out this work, we used combinations of hydrogen peroxide and pH to differentially oxidize IFNß-1a (to focus on only methionine oxidation versus methionine and cysteine oxidation). We then employed several analytical and biophysical techniques to acquire information about the differential impact of these two oxidation scenarios on IFNß-1a. In particular, the use of MS-based techniques, especially HDX-MS, play a dominant role in revealing the differential effects. Graphical Abstract ᅟ.


Assuntos
Adjuvantes Imunológicos/química , Antivirais/química , Cisteína/química , Interferon beta-1a/química , Metionina/química , Animais , Células CHO , Cromatografia Líquida de Alta Pressão , Cricetulus , Humanos , Peróxido de Hidrogênio/química , Concentração de Íons de Hidrogênio , Espectrometria de Massas , Modelos Moleculares , Oxirredução , Mapeamento de Peptídeos , Conformação Proteica
13.
MAbs ; 9(2): 364-382, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28005456

RESUMO

A biosimilar is a biological medicinal product that contains a version of the active substance of an already authorized original biological medicinal product. Biosimilarity to the reference product (RP) in terms of quality characteristics, such as physicochemical and biological properties, safety, and efficacy, based on a comprehensive comparability exercise needs to be established. SB2 (Flixabi® and Renflexis®) is a biosimilar to Remicade® (infliximab). The development of SB2 was performed in accordance with relevant guidelines of the International Conference on Harmonisation, the European Medicines Agency, and the United States Food and Drug Administration. To determine whether critical quality attributes meet quality standards, an extensive characterization test was performed with more than 80 lots of EU- and US-sourced RP. The physicochemical characterization study results revealed that SB2 was similar to the RP. Although a few differences in physicochemical attributes were observed, the evidence from the related literature, structure-activity relationship studies, and comparative biological assays showed that these differences were unlikely to be clinically meaningful. The biological characterization results showed that SB2 was similar to the RP in terms of tumor necrosis factor-α (TNF-α) binding and TNF-α neutralization activities as a main mode of action. SB2 was also similar in Fc-related biological activities including antibody-dependent cell-mediated cytotoxicity, complement-dependent cytotoxicity, neonatal Fc receptor binding, C1q binding, and Fc gamma receptor binding activities. These analytical findings support that SB2 is similar to the RP and also provide confidence of biosimilarity in terms of clinical safety and efficacy.


Assuntos
Medicamentos Biossimilares/química , Medicamentos Biossimilares/farmacologia , Infliximab/química , Infliximab/farmacologia , Animais , Humanos
14.
J Pharm Sci ; 105(11): 3269-3277, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27578543

RESUMO

Hydrogen deuterium exchange coupled to mass spectrometry (HDX-MS) has become an established method for analysis of protein higher order structure. Here, we use HDX-MS methodology based on manual solid-phase extraction (SPE) to allow fast and simplified conformational analysis of proteins under pharmaceutically relevant formulation conditions. Of significant practical utility, the methodology allows global HDX-MS analyses to be performed without refrigeration or external cooling of the setup. In mode 1, we used dimethyl sulphoxide-containing solvents for SPE, allowing the HDX-MS analysis to be performed at acceptable back-exchange levels (<30%) without the need for cooling any components of the setup. In mode 2, SPE and chromatography were performed using fast isocratic elution at 0°C resulting in a back-exchange of 10%-30%. Real-world applicability was demonstrated by HDX-MS analyses of interferon-ß-1a in formulation, using an internal HDX reference peptide (P7I) to control for any sample-to-sample variations in back-exchange. Advantages of the methodology include low sample use, optimized excipient removal using multiple solvents, and fast data acquisition. Our results indicate that HDX-MS can provide a reliable approach for fast conformation analysis of proteins in their intended formulations, which could facilitate an increased use of the technique in pharmaceutical development research.


Assuntos
Angiotensina II/análise , Medição da Troca de Deutério/métodos , Insulina/análise , Interferon beta-1a/análise , Angiotensina II/química , Animais , Células CHO , Cricetinae , Cricetulus , Dimetil Sulfóxido/química , Humanos , Insulina/química , Interferon beta-1a/química , Conformação Proteica , Extração em Fase Sólida/métodos , Fatores de Tempo
15.
MAbs ; 8(6): 1136-55, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27246928

RESUMO

A biosimilar is a biological medicinal product that is comparable to a reference medicinal product in terms of quality, safety, and efficacy. SB4 was developed as a biosimilar to Enbrel® (etanercept) and was approved as Benepali®, the first biosimilar of etanercept licensed in the European Union (EU). The quality assessment of SB4 was performed in accordance with the ICH comparability guideline and the biosimilar guidelines of the European Medicines Agency and Food and Drug Administration. Extensive structural, physicochemical, and biological testing was performed with state-of-the-art technologies during a side-by-side comparison of the products. Similarity of critical quality attributes (CQAs) was evaluated on the basis of tolerance intervals established from quality data obtained from more than 60 lots of EU-sourced and US-sourced etanercept. Additional quality assessment was focused on a detailed investigation of immunogenicity-related quality attributes, including hydrophobic variants, high-molecular-weight (HMW) species, N-glycolylneuraminic acid (NGNA), and α-1,3-galactose. This comprehensive characterization study demonstrated that SB4 is highly similar to the reference product, Enbrel®, in structural, physicochemical, and biological quality attributes. In addition, the levels of potential immunogenicity-related quality attributes of SB4 such as hydrophobic variants, HMW aggregates, and α-1,3-galactose were less than those of the reference product.


Assuntos
Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/imunologia , Medicamentos Biossimilares/química , Etanercepte/química , Etanercepte/imunologia , Animais , Células CHO , Varredura Diferencial de Calorimetria , Cromatografia em Gel , Cricetulus , União Europeia , Glicosilação , Humanos , Concentração de Íons de Hidrogênio , Ácido N-Acetilneuramínico/análise , Ácidos Neuramínicos/análise , Mapeamento de Peptídeos , Conformação Proteica , Processamento de Proteína Pós-Traducional , Análise de Sequência de Proteína , Estados Unidos , United States Food and Drug Administration
16.
J Am Soc Mass Spectrom ; 27(4): 669-76, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26860088

RESUMO

When highly concentrated, an antibody solution can exhibit unusual behaviors, which can lead to unwanted properties, such as increased levels of protein aggregation and unusually high viscosity. Molecular modeling, along with many indirect biophysical measurements, has suggested that the cause for these phenomena can be due to short range electrostatic and/or hydrophobic protein-protein interactions. Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a useful tool for investigating protein conformation, dynamics, and interactions. However, "traditional" continuous dilution labeling HDX-MS experiments have limited utility for the direct analysis of solutions with high concentrations of protein. Here, we present a dialysis-based HDX-MS (di-HDX-MS) method as an alternative HDX-MS labeling format, which takes advantage of passive dialysis rather than the classic dilution workflow. We applied this approach to a highly concentrated antibody solution without dilution or significant sample manipulation, prior to analysis. Such a method could pave the way for a deeper understanding of the unusual behavior of proteins at high concentrations, which is highly relevant for development of biopharmaceuticals in industry. Graphical Abstract ᅟ.


Assuntos
Anticorpos Monoclonais/química , Medição da Troca de Deutério/instrumentação , Diálise/instrumentação , Espectrometria de Massas/instrumentação , Animais , Células CHO , Cricetulus , Desenho de Equipamento , Modelos Moleculares , Conformação Proteica , Soluções
17.
J Pharm Sci ; 104(11): 3984-3989, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26308556

RESUMO

Protein self-association or aggregation is a property of significant concern for biopharmaceutical products due to the potential ability of aggregates to cause adverse toxicological and immunological effects. Thus, during the development of a protein biopharmaceutical, it is important to detect and quantify the level and nature of aggregate species as early as possible in order to make well-informed decisions and to mitigate and control potential risks. Although a deeper understanding of the mechanism of aggregation (i.e., protein-protein interactions) is desirable, such detailed assessment is not always necessary from a biopharmaceutical process development point of view. In fact, the scope of characterization efforts is often focused on achieving a well-controlled process, which generates a product that reliably meets established acceptance criteria for safety and efficacy. In this brief note, we evaluated the utility of size-exclusion chromatography, dynamic light scattering, and analytical ultracentrifugation in their simplest forms, to effectively reveal and confirm the presence of concentration-dependent reversible self-association (RSA) in a monoclonal antibody in the early stages of formulation development. Using these techniques, we also initiated preliminary work aimed at reducing the occurrence of this RSA behavior by varying the pH of the formulation buffer.


Assuntos
Anticorpos Monoclonais/química , Imunoglobulina G/química , Agregados Proteicos , Difusão Dinâmica da Luz/métodos , Tamanho da Partícula , Ultracentrifugação/métodos
18.
Blood ; 126(8): 935-8, 2015 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-26065652

RESUMO

Association with the D'D3 domain of von Willebrand factor (VWF) stabilizes factor VIII (FVIII) in the circulation and maintains it at a level sufficient to prevent spontaneous bleeding. We used negative-stain electron microscopy (EM) to visualize complexes of FVIII with dimeric and monomeric forms of the D'D3 domain. The EM averages show that FVIII interacts with the D'D3 domain primarily through its C1 domain, with the C2 domain providing a secondary attachment site. Hydrogen-deuterium exchange mass spectrometry corroborated the importance of the C1 domain in D'D3 binding and implicates additional surface regions on FVIII in the interaction. Together, our results establish that the C1 domain is the major binding site on FVIII for VWF, reiterate the importance of the a3 acidic peptide in VWF binding, and suggest that the A3 and C2 domains play ancillary roles in this interaction.


Assuntos
Fator VIII/química , Fator VIII/metabolismo , Fator de von Willebrand/química , Fator de von Willebrand/metabolismo , Sítios de Ligação , Fator VIII/ultraestrutura , Células HEK293 , Humanos , Espectrometria de Massas , Microscopia Eletrônica , Estrutura Terciária de Proteína , Fator de von Willebrand/ultraestrutura
19.
J Pharm Sci ; 102(12): 4315-29, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24136070

RESUMO

To determine how structural changes in antibodies are connected with aggregation, the structural areas of an antibody prone to and/or impacted by aggregation must be identified. In this work, the higher-order structure and biophysical properties of two different monoclonal antibody (mAb) monomers were compared with their simplest aggregated form, that is, dimers that naturally occurred during normal production and storage conditions. A combination of hydrogen/deuterium exchange mass spectrometry and other biophysical measurements was used to make the comparison. The results show that the dimerization process for one of the mAb monomers (mAb1) displayed no differences in its deuterium uptake between monomer and dimer forms. However, the other mAb monomer (mAb2) showed subtle changes in hydrogen/deuterium exchange as compared with its dimer form. In this case, differences observed were located in specific functional regions of the CH 2 domain and the hinge region between CH 1 and CH 2 domains. The importance and the implications of these changes on the antibody structure and mechanism of aggregation are discussed.


Assuntos
Anticorpos Monoclonais/química , Animais , Células CHO , Varredura Diferencial de Calorimetria , Cricetulus , Dissulfetos/análise , Eletroforese em Gel de Poliacrilamida , Espectrometria de Massas , Modelos Moleculares , Conformação Proteica , Multimerização Proteica , Estabilidade Proteica , Espalhamento a Baixo Ângulo , Difração de Raios X
20.
J Am Soc Mass Spectrom ; 23(7): 1202-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22528203

RESUMO

Management of the enormous amount of data produced during solution-phase hydrogen/deuterium exchange monitored by mass spectrometry has stimulated software analysis development. The proteolysis step of the experiment generates multiple peptide fragments, most of which overlap. Prior automated data reduction algorithms extract the deuteration level for individual peptides, but do not exploit the additional information arising from fragment overlap. Here, we describe an algorithm that determines discrete rate constant values to each of the amide hydrogens in overlapped fragments. By considering all of the overlapped peptide segments simultaneously, sequence resolution can be improved significantly, sometimes to the individual amino acid level. We have validated the method with simulated deuterium uptake data for seven overlapped fragments of a poly-Ala nonapeptide, and then applied it to extract rate constant values for the first 29 N-terminal amino acids of C22A FK506-binding protein.


Assuntos
Medição da Troca de Deutério/métodos , Espectrometria de Massas/métodos , Fragmentos de Peptídeos/química , Análise de Sequência de Proteína/métodos , Algoritmos , Sequência de Aminoácidos , Simulação por Computador , Dados de Sequência Molecular , Proteólise , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...