Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
Semin Nucl Med ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38670819
2.
Gynecol Oncol ; 182: 179-187, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38335900

RESUMO

INTRODUCTION: It is unclear if sentinel node (SLN) mapping can replace pelvic- (PLD) and paraaortic lymphadenectomy (PALD) for high-risk endometrial cancer (EC). A diagnostically safe surgical algorithm, taking failed mapping cases into account, is not defined. We aimed to investigate the diagnostic accuracy of SLN mapping algorithms in women with exclusively high-risk EC. METHODS: We undertook a prospective national diagnostic cohort study of SLN mapping in women with high-risk EC from March 2017 to January 2023. The power calculation was based on the negative predictive value (NPV). Women underwent SLN mapping, PLD and PALD besides removal of suspicious and any FDG/PET-positive lymph nodes. Accuracy analyses were performed for five algorithms. RESULTS: 170/216 included women underwent SLN mapping, PLD and PALD and were included in accuracy analyses. 42/170 (24.7%) had nodal metastasis. The algorithm SLN and PLD in case of failed mapping, demonstrated a sensitivity of 86% (95% CI 74-100) and an NPV of 96% (95% CI 91-100). The sensitivity increased to 93% (95% CI 83-100) and the NPV to 98% (95% CI 94-100) if PLD was combined with removal of any PET-positive lymph nodes. Equivalent results were obtained if PLD and PALD were performed in non-mapping cases; sensitivity 93% (95% CI 83-100) and NPV 98% (95% CI 95-100). CONCLUSION: SLN-mapping is a safe staging procedure in women with high-risk EC if strictly adhering to a surgical algorithm including removal of any PET-positive lymph nodes independent of location and PLD or PLD and PALD in case of failed mapping.


Assuntos
Neoplasias do Endométrio , Endometriose , Linfonodo Sentinela , Feminino , Humanos , Biópsia de Linfonodo Sentinela/métodos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Estudos Prospectivos , Estudos de Coortes , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/cirurgia , Excisão de Linfonodo/métodos , Endometriose/cirurgia , Algoritmos , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Linfonodos/patologia , Estadiamento de Neoplasias
3.
Semin Nucl Med ; 54(2): 183, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38360441
4.
J Nucl Cardiol ; 32: 101796, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278706

RESUMO

BACKGROUND: Differences in tracer characteristics may influence the interpretation of positron emission tomography myocardial perfusion imaging (MPI). We compare the reading of MPIs with a low-extraction retention tracer (82Rb) and a high-extraction non-retention tracer (15O-water) in a selected cohort of patients with known coronary artery disease (CAD). METHODS: Thirty-nine patients with known CAD referred to 82Rb MPI due to angina underwent rest and stress imaging with both tracers and experienced MPI readers provided blinded consensus reads of all studies. In addition, a comparison of regional and global quantitative measures of perfusion was performed. RESULTS: The results showed 74 % agreement in the reading of 82Rb and 15O-water MPI for regional reversible ischemia and global disease, and 82 % agreement for regional irreversible ischemia. The 15O-water MPI identified more cases of global disease (n = 12 (15O-water) vs n = 4 (82Rb), p = 0.03), whereas differences in reversible ischemia (n = 22 vs n = 16, p = 0.11) and, irreversible ischemia (n = 8 vs n = 11, p = 0.45) were not significant. The correlation between myocardial blood flow measured using the two tracers was similar to previous studies (R2 = 0.78) with wide limits of agreement (-0.93 to 0.84 ml/g/min). CONCLUSIONS: Agreement between consensus readings of 82Rb and 15O-water MPI was good in patients with known CAD. In this limited size study, no significant differences in the identification of reversible and irreversible ischemia found, whereas 15O-water MPI had a higher positive rate for suspected global disease.


Assuntos
Isquemia , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons , Humanos , Radioisótopos de Rubídio
5.
EJNMMI Res ; 14(1): 11, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38294730

RESUMO

BACKGROUND: [15O]H2O PET/CT allows noninvasive quantification of tissue perfusion and can potentially play a future role in the diagnosis and treatment of peripheral artery disease. We aimed to evaluate the reliability of dynamic [15O]H2O PET imaging for measuring lower extremity skeletal muscle perfusion. Ten healthy participants underwent same-day test-retest study with six dynamic [15O]H2O PET scans of lower legs and feet. Manual volume-of-interests were drawn in skeletal muscles, and PET time activity curves were extracted. K1 values (mL/min/100 mL) were estimated using a single-tissue compartment model (1TCM), autoradiography (ARG), and parametric imaging with blood input functions obtained from separate heart scans. RESULTS: Resting perfusion values in the muscle groups of the lower legs ranged from 1.18 to 5.38 mL/min/100 mL (ARG method). In the muscle groups of the feet, perfusion values ranged from 0.41 to 3.41 mL/min/100 mL (ARG method). Test-retest scans demonstrated a strong correlation and good repeatability for skeletal muscle perfusion with an intraclass correlation coefficient (ICC) of 0.88 and 0.87 and a repeatability coefficient of 34% and 53% for lower legs and feet, respectively. An excellent correlation was demonstrated when comparing volume-of-interest-based methods (1TCM and ARG) (lower legs: ICC = 0.96, feet: ICC = 0.99). Parametric images were in excellent agreement with the volume-of-interest-based ARG method (lower legs: ICC = 0.97, feet: ICC = 0.98). CONCLUSION: Parametric images and volume-of-interest-based methods demonstrated comparable resting perfusion values in the lower legs and feet of healthy individuals. The largest variation was seen between individuals, whereas a smaller variation was seen between muscle groups. Repeated measurements of resting blood flow yielded a strong overall correlation for all methods.

6.
Semin Nucl Med ; 54(1): 39-45, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37487824

RESUMO

Prostate-specific membrane antigen PET/CT for primary staging of prostate cancer is becoming increasingly popular due to simultaneous assessment of whole-body disease burden, with superior sensitivity and specificity for detecting metastases compared to conventional imaging. PSMA PET in combination with multiparametric MRI (mpMRI) improves the sensitivity of assessment of extra-prostatic extension and seminal vesicle invasion compared to mpMRI alone, and may serve as a second line modality for image-guided biopsy in selected patients with negative mpMRI and/or negative primary biopsies. The superior diagnostic accuracy of PSMA PET/CT affects clinical decision-making with a change of clinical management in one-fourth of patients compared to conventional imaging. However, at present, the effect of implementing PSMA PET/CT for primary staging on patient outcomes is not clear, and prospective studies are warranted. There are several PSMA tracers with similar performance and minor individual pharmacokinetic differences such as higher rate of unspecific bone uptake with 18F-PSMA-1007, but on the other hand, lower urinary excretion, which could give an advantage in the detection of local recurrence. Proper training of the reporting physicians and knowledge of the pitfalls of the specific PSMA tracer used is of utmost importance for high-quality reading. We aim to provide an overview of the current literature and an update on the status of PSMA PET/CT for primary staging of prostate cancer.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Gálio , Neoplasias da Próstata/patologia , Próstata/patologia , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Estadiamento de Neoplasias
7.
Semin Nucl Med ; 54(1): 1-3, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38065626
8.
Semin Nucl Med ; 53(6): 731-732, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37739849
9.
Circ Cardiovasc Imaging ; 16(8): e015184, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37529907

RESUMO

BACKGROUND: Rubidium-82 positron emission tomography (82Rb PET) myocardial perfusion imaging is used in clinical practice to quantify regional perfusion defects. Additionally, 82Rb PET provides a measure of absolute myocardial flow reserve (MFR), describing the vasculature state of health. We assessed whether 82Rb PET-derived MFR is associated with all-cause mortality independently of the extent of perfusion defects. METHODS: We conducted a multicenter clinical registry-based study of patients undergoing 82Rb PET myocardial perfusion imaging on suspicion of chronic coronary syndromes. Patients were followed up in national registries for the primary outcome of all-cause mortality. Global MFR ≤2 was considered reduced. RESULTS: Among 7169 patients studied, 38.1% were women, the median age was 69 (IQR, 61-76) years, and 39.0% had MFR ≤2. A total of 667 (9.3%) patients died during a median follow-up of 3.1 (IQR, 2.6-4.0) years, more in patients with MFR ≤2 versus MFR >2 (15.7% versus 5.2%; P<0.001). MFR ≤2 was associated with all-cause mortality across subgroups defined by the extent of perfusion defects (all P<0.05). In a Cox survival regression model adjusting for sex, age, comorbidities, kidney function, left ventricular ejection fraction, and perfusion defects, MFR ≤2 was a robust predictor of mortality with a hazard ratio of 1.62 (95% CI, 1.31-2.02; P<0.001). Among patients with no reversible perfusion defects (n=3101), MFR ≤2 remained strongly associated with mortality (hazard ratio, 1.86 [95% CI, 1.26-2.73]; P<0.01). The prognostic value of impaired MFR was similar for cardiac and noncardiac death. CONCLUSIONS: MFR ≤2 predicts all-cause mortality independently of the extent of perfusion defects. Our results support the inclusion of MFR when assessing the prognosis of patients suspected of chronic coronary syndromes.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Idoso , Masculino , Volume Sistólico , Imagem de Perfusão do Miocárdio/métodos , Prognóstico , Síndrome , Função Ventricular Esquerda , Tomografia por Emissão de Pósitrons/métodos , Perfusão , Dinamarca/epidemiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária
10.
Eur J Nucl Med Mol Imaging ; 51(1): 281-294, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37597010

RESUMO

PURPOSE: The current clinical recommendations posit the deployment of specific approved radiolabeled prostate-specific membrane antigen-ligand positron emission tomography (PSMA PET) for detecting metastatic prostate cancer during primary staging. Nevertheless, the precise efficacy of such ligands in localizing intraprostatic tumours (index tumour) and T-staging is not well established. Consequently, the objective of this inquiry is to ascertain the diagnostic accuracy of PSMA-PET in the tumour staging of newly diagnosed prostate cancer by means of a meta-analysis that integrates studies utilizing histological confirmation as the reference standard. METHODS: In this study, we conducted a systematic literature search of the PubMed, Embase, Web of Science, and Cochrane Library databases using a predefined collection of search terms. These terms included 'PSMA PET', 'primary staging', and 'prostate cancer'. Subsequently, two independent reviewers evaluated all the studies based on predetermined inclusion criteria, extracted pertinent data, and assessed the quality of evidence. Any disparities were resolved by a third reviewer. A random effects Sidik-Jonkman model was applied to conduct a meta-analysis and estimate the diagnostic accuracy on a per-patient basis, along with 95% confidence intervals. Moreover, an appraisal regarding the likelihood of publication bias and the impact of small-study effects was performed utilizing both Egger's test and a graphical examination of the funnel plot. RESULTS: The present analysis comprised a total of twenty-three scientific papers encompassing 969 patients and involved their analysis by both qualitative and quantitative approaches. The results of this study demonstrated that the estimated diagnostic accuracy of PSMA PET/CT and PSMA PET/MRI, for the detection of intraprostatic tumours, regardless of the type of PSMA-ligand, was 86% (95% CI: 76-96%) and 97% (95% CI: 94-100%), respectively. Furthermore, the diagnostic accuracy for the detection of extraprostatic extension (EPE) was 73% (95% CI: 64-82%) and 77% (95% CI: 69-85%), while the diagnostic accuracy for the detection of seminal vesicle involvement (SVI) was 87% (95% CI: 80-93) and 90% (95% CI: 82-99%), respectively. CONCLUSION: The present investigation has demonstrated that PSMA PET/MRI surpasses currently recommended multiparametric magnetic resonance imaging (mpMRI) in terms of diagnostic accuracy as inferred from a notable data trajectory, whereas PSMA-PET/CT exhibited comparable diagnostic accuracy for intraprostatic tumour detection and T-staging compared to mpMRI. Nevertheless, the analysis has identified certain potential limitations, such as small-study effects and a potential for publication bias, which may impact the overall conclusions drawn from this study.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estadiamento de Neoplasias , Ligantes , Radioisótopos de Gálio , Neoplasias da Próstata/patologia , Tomografia por Emissão de Pósitrons
11.
Semin Nucl Med ; 53(5): 555-557, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37451935
12.
J Am Heart Assoc ; 12(12): e028767, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37318021

RESUMO

Background Coronary microvascular disease (CMD) may be part of a systemic small vessel disease that also manifests as neurological impairment and kidney disease. However, clinical evidence supporting a potential link is scarce. We assessed whether CMD is associated with an increased risk of small vessel disease in the kidney and brain. Methods and Results A retrospective multicenter (n=3) study of patients clinically referred to 82-rubidium positron emission tomography myocardial perfusion imaging was conducted between January 2018 and August 2020. Exclusion criterion was reversible perfusion defects >5%. CMD was defined as myocardial flow reserve (MFR) ≤2. The primary outcome, microvascular event, was defined by hospital contact for chronic kidney disease, stroke, or dementia. Among 5122 patients, 51.7% were men, median age 69.0 [interquartile range, 60.0-75.0] years, 11.0% had left ventricular ejection fraction ≤40%, and 32.4% had MFR ≤2. MFR was associated with baseline estimated glomerular filtration rate after multivariable adjustment (ß=0.04 [95% CI, 0.03-0.05]; P<0.001). During a median follow-up of 3.05 years, 383 (7.5%) patients suffered an event (253 cerebral and 130 renal), more frequently in patients with MFR ≤2 versus MFR >2 (11.6% versus 5.5%, P<0.001). MFR ≤2 was associated to outcome with a hazard ratio (HR) of 2.30 (95% CI, 1.88-2.81, P<0.001) and an adjusted HR of 1.62 (95% CI, 1.32-2.00, P<0.001). Results were consistent across subgroups defined by presence of irreversible perfusion defects, estimated glomerular filtration rate, diabetes, left ventricular ejection fraction, and previous revascularization. Conclusions This is the first large-scale cohort study to link CMD to microvascular events in the kidney and brain. Data support the hypothesis that CMD is part of a systemic vascular disorder.


Assuntos
Doença da Artéria Coronariana , Angina Microvascular , Imagem de Perfusão do Miocárdio , Doenças Vasculares , Masculino , Humanos , Idoso , Feminino , Rubídio , Volume Sistólico , Estudos de Coortes , Imagem de Perfusão do Miocárdio/métodos , Função Ventricular Esquerda , Tomografia por Emissão de Pósitrons , Doença da Artéria Coronariana/diagnóstico por imagem , Rim/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Circulação Coronária
13.
Semin Nucl Med ; 53(4): 467-468, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37188566
14.
Gynecol Oncol ; 171: 121-128, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36893488

RESUMO

OBJECTIVE: The SENTIREC-endo study aims to investigate risks and benefits of a national protocolled adoption of sentinel lymph node (SLN) mapping in women with early-stage low-grade endometrial cancer (EC) with low- (LR) and intermediate-risk (IR) of lymph node metastases. METHODS: We performed a national multicenter prospective study of SLN-mapping in women with LR and IR EC from March 2017-February 2022. Postoperative complications were classified according to Clavien-Dindo. Lymphedema was assessed as a change score and as incidence of swelling and heaviness evaluated by validated patient-reported outcome measures at baseline and three months postoperatively. RESULTS: 627 women were included in the analyses; 458 with LR- and 169 with IR EC. The SLN detection rate was 94.3% (591/627). The overall incidence of lymph node metastases was 9.3% (58/627); 4.4% (20/458) in the LR- and 22.5% (38/169) in the IR group. Ultrastaging identified 62% (36/58) of metastases. The incidence of postoperative complications was 8% (50/627) but only 0.3% (2/627) experienced an intraoperative complication associated with the SLN procedure. The lymphedema change score was below the threshold for clinical importance 4.5/100 CI: (2.9-6.0), and the incidence of swelling and heaviness was low; 5.2% and 5.8%, respectively. CONCLUSION: SLN mapping in women with LR and IR EC carries a very low risk of early lymphedema and peri- and postoperative complications. The national change in clinical practice contributed to a more correct treatment allocation for both risk groups and thus supports further international implementation of the SLN technique in early stage, low grade EC.


Assuntos
Neoplasias do Endométrio , Endometriose , Linfedema , Linfonodo Sentinela , Feminino , Humanos , Linfonodos/cirurgia , Linfonodos/patologia , Biópsia de Linfonodo Sentinela/efeitos adversos , Biópsia de Linfonodo Sentinela/métodos , Metástase Linfática/patologia , Excisão de Linfonodo/efeitos adversos , Excisão de Linfonodo/métodos , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Estudos Prospectivos , Neoplasias do Endométrio/patologia , Endometriose/cirurgia , Linfedema/epidemiologia , Linfedema/etiologia , Linfedema/patologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/patologia , Medição de Risco , Estadiamento de Neoplasias
15.
Semin Nucl Med ; 53(2): 135-137, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36775725
16.
Diagnostics (Basel) ; 13(3)2023 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-36766549

RESUMO

We report the case of a 69-year-old woman who underwent 18F-FDG PET/CT due to prolonged fever. One month before, the patient was diagnosed with COVID-19 infection. The 18F-FDG PET/CT showed several subcutaneous nodules with 18F-FDG uptake on the thorax and upper extremities and bilateral lung infiltrates due to organizing pneumonitis. Clinical examination revealed multiple tender nodules on thorax, arms, and legs, consistent with erythema nodosum (EN) induced by COVID-19 infection. The woman was treated with prednisone with a good effect on EN. To our knowledge, this is the first report on EN secondary to COVID-19 infection diagnosed on 18F-FDG PET/CT.

17.
Semin Nucl Med ; 53(3): 301-302, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36737347
18.
Semin Nucl Med ; 53(1): 1-3, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36460419
19.
Acta Oncol ; 61(10): 1289-1294, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36199168

RESUMO

BACKGROUND: Accurate primary staging is one of the most important issues for initial management of prostate cancer (PCa) patients to perform an optimal selection of patients for curative intended treatment. 68Ga-Prostate-Specific-Membrane-Antigen (PSMA) PET/CT was found superior to conventional imaging both for detection of recurrence after curative intended treatment and for primary staging. We studied the recurrence rate after radical prostatectomy in high-risk PCa patients primary staged with 68Ga-PSMA PET/CT compared with conventional imaging. MATERIAL AND METHODS: The study included 247 D'Amico high-risk PCa patients treated with radical prostatectomy (RP) after primary staging with 68Ga-PSMA PET/CT and a reference group of 137 high-risk patients with RP after conventional imaging (99mTc bone scintigraphy and CT). Recurrence rates were assessed by Cox regression and Kaplan-Meier analysis. RESULTS: The 5-year recurrence-free survival rate was 71.1% in the 68Ga-PSMA PET/CT cohort compared with 56.4% in the conventional imaging cohort. Primary staging by 68Ga-PSMA PET/CT reduced biochemical recurrence (BCR) risk by 42% (HR = 0.58 (0.41-0.83), p = .004). CONCLUSION: The present data could indicate a lower recurrence rate after RP following primary staging with 68Ga-PSMA PET/CT compared to conventional imaging, likely due to improved selection of patients for surgery.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Próstata/patologia , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Estadiamento de Neoplasias
20.
Semin Nucl Med ; 52(6): 647-649, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36064660
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...