Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(7): 1280-1287, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37043622

RESUMO

OBJECTIVES: Monitoring quality indicators (QIs) is an important part of laboratory quality assurance (QA). Here, the Canadian Society of Clinical Chemists (CSCC) Point of Care Testing (POCT) and QI Special Interest Groups describe a process for establishing and monitoring QIs for POCT glucose testing. METHODS: Key, error prone steps in the POCT glucose testing process were collaboratively mapped out, followed by risk assessment for each step. Steps with the highest risk and ability to detect a non-conformance were chosen for follow-up. These were positive patient identification (PPID) and repeat of critically high glucose measurements. Participating sites were asked to submit aggregate data for these indicators from their site(s) for a one-month period. The PPID QI was also included as part of a national QI monitoring program for which fifty-seven sites submitted data. RESULTS: The percentage of POCT glucose tests performed without valid PPID ranged from 0-87%. Sites without Admission-Discharge-Transfer (ADT) connectivity to POCT meters were among those with the highest percentage of POCT glucose tests performed without valid PPID. The percentage repeated critically high glucose measurements ranged from 0-50%, indicating low compliance with this recommendation. A high rate of discordance was also noted when critically high POCT glucose measurements were repeated, demonstrating the importance of repeat testing prior to insulin administration. CONCLUSIONS: Here, a process for establishing these QIs is described, with preliminary data for two QIs chosen from this process. The findings demonstrate the importance of QIs for identification and comparative performance monitoring of non-conformances to improve POCT quality.


Assuntos
Glucose , Sistemas Automatizados de Assistência Junto ao Leito , Indicadores de Qualidade em Assistência à Saúde , Canadá , Opinião Pública , Glucose/química , Testes Imediatos , Humanos
2.
Diagn Microbiol Infect Dis ; 101(3): 115412, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34425450

RESUMO

The COVID-19 pandemic has led to the influx of immunoassays for the detection of antibodies towards severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) into the global market. The Canadian Public Health Laboratory Network Serology Task Force undertook a nationwide evaluation of twelve laboratory and 6 point-of-care based commercial serological assays for the detection of SARS-CoV-2 antibodies. We determined that there was considerable variability in the performance of individual tests and that an orthogonal testing algorithm should be prioritized to maximize the accuracy and comparability of results across the country. The manual enzyme immunoassays and point-of-care tests evaluated had lower specificity and increased coefficients of variation compared to automated enzyme immunoassays platforms putting into question their utility for large-scale sero-surveillance. Overall, the data presented here provide a comprehensive approach for applying accurate serological assays for longitudinal sero-surveillance and vaccine trials while informing Canadian public health policy.


Assuntos
Anticorpos Antivirais/sangue , COVID-19/epidemiologia , Laboratórios/normas , Saúde Pública , SARS-CoV-2/imunologia , Testes Sorológicos/normas , COVID-19/sangue , Canadá/epidemiologia , Ensaios de Triagem em Larga Escala , Humanos , Técnicas Imunoenzimáticas , SARS-CoV-2/isolamento & purificação , Testes Sorológicos/métodos
3.
Clin Biochem ; 51: 10-20, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29061378

RESUMO

Protein electrophoresis is commonly used as an aid in the diagnosis of monoclonal gammopathies and is performed in many laboratories in Canada and throughout the world. However, unlike many other diagnostic tests, there is limited guidance for standardization and neither guidance nor specific recommendations for clinical reporting of serum (SPE) or urine (UPE) protein electrophoresis and immunotyping available in the literature. Therefore, a Canadian effort was undertaken to recommend standards that cover all aspects of clinical reporting with an ultimate goal towards reporting standardization. The Canadian Society of Clinical Chemists (CSCC) Monoclonal Gammopathy Interest Group (MGIG), which is composed of CSCC members with an interest in protein electrophoresis, has formed a Monoclonal Gammopathy Working Group (MGWG) to take initial steps towards standardization of SPE, UPE and immunotyping. Candidate standardization recommendations were developed, discussed and voted upon by the MGWG. Candidate recommendations that achieved 90% agreement are presented as consensus recommendations. Recommendations that did not achieve 90% consensus remain candidate recommendations and are presented with accompanying MGWG discussion. Eleven consensus recommendations along with candidate recommendations for nomenclature, protein fraction reporting, test utilization, interference handling and interpretive reporting options are presented.


Assuntos
Eletroforese das Proteínas Sanguíneas/métodos , Guias como Assunto , Paraproteinemias/sangue , Sociedades Médicas , Canadá , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...