Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Morphologie ; 103(341): 37-47, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30638803

RESUMO

BACKGROUND: The kangaroo pericardium might be considered to be a good candidate material for use in the manufacture of the leaflets of percutaneous heart valves based upon the unique lifestyle. The diet consists of herbs, forbs and strubs. The kangaroo pericardium holds an undulated structure of collagen. MATERIAL AND METHOD: A Red Kangaroo was obtained after a traffic fatality and the pericardium was dissected. Four compasses were cut from four different sites: auricular (AUR), atrial (ATR), sternoperitoneal (SPL) and phrenopericardial (PPL). They were investigated by means of scanning electron microscopy, light microscopy and transmission electron microscopy. RESULTS: All the samples showed dense and wavy collagen bundles without vascularisation from both the epicardium and the parietal pericardium. The AUR and the ATR were 150±25µm thick whereas the SPL and the PPL were thinner at 120±20µm. The surface of the epicardium was smooth and glistening. The filaments of collagen were well individualized without any aggregation, but the banding was poorly defined and somewhat blurry. CONCLUSION: This detailed morphological analysis of the kangaroo pericardium illustrated a surface resistant to thrombosis and physical characteristics resistant to fatigue. The morphological characteristics of the kangaroo pericardium indicate that it represents an outstanding alternative to the current sources e.g., bovine and porcine. However, procurement of tissues from the wild raises supply and sanitary issues. Health concerns based upon sanitary uncertainty and reliability of supply of wild animals remain real problems.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Ligamentos/ultraestrutura , Macropodidae/anatomia & histologia , Pericárdio/ultraestrutura , Animais , Austrália , Doenças das Valvas Cardíacas/cirurgia , Humanos , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão
2.
Biofabrication ; 10(3): 035006, 2018 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-29638221

RESUMO

A major challenge during the engineering of voluminous bone tissues is to maintain cell viability in the central regions of the construct. In vitro prevascularization of bone substitutes relying on endothelial cell bioprinting has the potential to resolve this issue and to replicate the native bone microvasculature. Laser-assisted bioprinting (LAB) commonly uses biological layers of hydrogel, called 'biopapers', to support patterns of printed cells and constitute the basic units of the construct. The self-assembly approach of tissue engineering allows the production of biomimetic cell-derived bone extracellular matrix including living cells. We hypothesized that self-assembled osseous sheets can serve as living biopapers to support the LAB of human endothelial cells and thus guide tubule-like structure formation. Human umbilical vein endothelial cells were bioprinted on the surface of the biopapers following a predefined pattern of lines. The osseous biopapers showed relevant matrix mineralization and pro-angiogenic hallmarks. Our results revealed that formation of tubule-like structures was favored when the cellular orientation within the biopaper was parallel to the printed lines. Altogether, we validated that human osseous cell sheets can be used as biopapers for LAB, allowing the production of human prevascularized cell-based osseous constructs that can be relevant for autologous bone repair applications.


Assuntos
Bioimpressão/métodos , Células Endoteliais da Veia Umbilical Humana/citologia , Osteócitos/citologia , Engenharia Tecidual/métodos , Sobrevivência Celular/fisiologia , Técnicas de Cocultura , Humanos , Osteogênese/fisiologia
3.
Morphologie ; 101(333): 77-87, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28442174

RESUMO

INTRODUCTION: Cross-linking and anti-calcification of prosthetic heart valves have been continuously improved to prevent degeneration and calcification. However, non-calcific structural deteriorations such as cuspal dehiscences along the stent still require further analysis. MATERIAL AND METHOD: Based upon the previous analysis of an explanted valve after 7 years, a fresh commercial aortic valve was embedded in poly(methyl methacrylate) (PMMA) and cut into slices to ensure the detailed observation of the assembly and material structures. A pericardial patch embossed to provide the adequate shape of the cusps was investigated after paraffin embedding and appropriate staining. The microstructural damages that occurred during manufacturing process were identified and evaluated by light microscopy, polarized microscopy, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). RESULTS: The wavy collagen bundles, the key structure of the pericardium patch, were damaged to a great extent at suture sites along the stent and in the compressed areas around the stent post. The fixation of the embossed pericardium patch along the plots of the stent aggravated the microstructural modifications. The damages mainly appeared as the elimination of collagen bundle waviness and delamination between the bundles. CONCLUSION: Considering the modes of failure of the explant, the damages to the collagen bundles may identify the vulnerable sites that play an important role in the cusp dehiscence of heart valve implants. Such information is important to the manufacturers. Recommendations to prevent in vivo cusp dehiscence can therefore be formulated.


Assuntos
Valva Aórtica/ultraestrutura , Bioprótese , Próteses Valvulares Cardíacas , Pericárdio/ultraestrutura , Manejo de Espécimes/efeitos adversos , Animais , Valva Aórtica/patologia , Calcinose/prevenção & controle , Bovinos , Colágeno/ultraestrutura , Reagentes de Ligações Cruzadas/química , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Inclusão em Parafina , Pericárdio/anatomia & histologia , Pericárdio/patologia , Inclusão em Plástico/métodos , Polimetil Metacrilato/química , Falha de Prótese , Manejo de Espécimes/métodos , Stents
4.
Morphologie ; 101(332): 19-32, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27423215

RESUMO

INTRODUCTION: Transcathether heart valve replacement has gained considerable acceptance during the last decades. It is now part of the armamentarium for aortic valve replacement. The procedure proved to be highly efficient. However the issues of the blood compatibility and tissue durability were not raised and the adverse events were probably under-reported, according to observations of thrombosis after deployment. MATERIAL AND METHOD: Bovine pericardium leaflets were sewn inside a 26mm diameter stainless steel stent to manufacture these valves (one control and two experimental). The correlation between the trauma and the acute thombogenicity of bovine pericardium leaflets, after crimping and ballooning, was investigated via an in vitro blood flow with labeled platelets. These leaflets were processed for histology: scanning electron microscopy, light microscopy, and transmission electron microscopy. RESULTS: The control specimens showed a regular pericardium structure with some blood cells deposited on the collagen fibrous surface (inflow) and scarce blood cells deposited on the serous surface (outflow). After crimping and ballooning, the structure of the pericardium was severely injured, eventually with delaminations and ruptures. The blood cell uptake was considerably increased compared to the control. CONCLUSION: It would therefore be appropriate to pay more attention to the design of the valves. Specifically, the incorporation of a buffer tissue or fabric between the pericardium and the metallic stent is suggested. The issue of ballooning deserves detailed and in depth investigation regarding the lifetime of the device.


Assuntos
Valvuloplastia com Balão/instrumentação , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Desenho de Prótese/efeitos adversos , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Animais , Valva Aórtica/cirurgia , Circulação Sanguínea , Bovinos , Voluntários Saudáveis , Humanos , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Pericárdio/patologia , Pericárdio/cirurgia , Pericárdio/ultraestrutura , Stents/efeitos adversos , Propriedades de Superfície , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
Int Endod J ; 50(1): 48-57, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26650723

RESUMO

AIM: To develop a biological scaffold that could be moulded to reproduce the geometry of a gutta-percha point with precision and allow the differentiation of mesenchymal stem cells into osteoblasts to be used as a regenerative endodontic material. METHODOLOGY: A collagen/alginate composite scaffold was cast into a sodium alginate mould to produce a gutta-percha point-like cone. Prior to gelation, the cone was seeded with human stem cells from the apical papilla (SCAPs) to evaluate cell/scaffold interactions. The reconstructed tissue was characterized after 8 days in culture. Elastic modulus, tissue compaction and cell differentiation were assessed. Student t-tests and the Mann-Whitney U test were performed. RESULTS: The fabrication method developed enabled the shape of a gutta-percha point to be mimicked with great accuracy and reproducibility (P = 0.31). Stem cells seeded into this composite scaffold were able to spread, survive and proliferate (P < 0.001). Moreover, they were able to differentiate into osteoblasts and produce calcified osseous extracellular matrix (P < 0.001). The construct showed no significant contraction after 8 days, preserving its shape and tip diameter (P = 0.58). CONCLUSIONS: The composite scaffold could present substantial benefits compared to synthetic materials. It could provide a favourable healing environment in the root canal conducive for regenerative endodontics and is therefore appropriate to be evaluated in vivo in further studies.


Assuntos
Alginatos/farmacologia , Diferenciação Celular/efeitos dos fármacos , Colágeno/farmacologia , Células-Tronco Mesenquimais/citologia , Osteoblastos/citologia , Alicerces Teciduais/química , Ácido Glucurônico/farmacologia , Guta-Percha , Ácidos Hexurônicos/farmacologia , Humanos , Regeneração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...