Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38728067

RESUMO

BACKGROUND: Lesion durability and transmurality are crucial for successful radiofrequency (RF) ablation. This study provides a model of real-time RF lesion visualization and insights into the role of underlying parameters, as local impedance (LI). METHODS: A force-sensing, LI-sensing catheter was used for lesion creation in an ex vivo model involving cross-sections of porcine cardiac preparations. During 60 s of RF application, one measurement per second was performed regarding lesion size and available ablation parameters. In total, 1847 measurements from n = 36 lesions were performed. Power (20-50 W) and contact force (1-5 g, 10-15 g, 20-25 g) were systematically alternated. RESULTS: Lesion formation was most prominent in the first seconds of RF application during which nonlinear lesion growth was observed (max. 1.08 mm/s for lesion depth and 2.71 mm/s for lesion diameter). Power levels determined the extent of lesion formation in the early phase. After 20 s, lesion size growth velocity approaches 0.1 mm/s at all power levels. LI changes were also highest in the first seconds (up to - 12 Ω/s) and decreased to less than - 0.1Ω/s after prolonged application. CONCLUSION: Lesion formation in irrigated RF ablation is a nonlinear process. Final lesion size resulting from an RF application is mainly influenced by high rates of lesion growth in the first seconds of ablation. LI seems to be a good surrogate for differentiating changes in lesion formation.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38775921

RESUMO

BACKGROUND: Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of cardiac implantable electronic devices (CIEDs) in the form of electromagnetic interference (EMI). The aim of our study was to assess the impact of PFA on CIEDs. METHODS: PFA lesions (45 per CIED) were applied from the Farapulse system to CIEDs (< 5 cm from the lead tip and < 15 cm from the generator). All devices were checked before and after PFA application for proper sensing and pacing functionality as well as for integrity of shock circuits in ICDs using a heart simulator. Moreover, devices were then interrogated for any spontaneous reprogramming, mode switching or other EMI effects. RESULTS: In total, 44 CIEDs were tested (16 pacemaker, 21 ICDs, 7 CRT-P/D) with 1980 PFA applications. There was no change in device settings, functionality and electrical parameters, and there was no macroscopic damage to the devices. The risk of damage to the electric components or leads on a patient-based analysis is 0/44 (95% CI 0-8%) and on a PFA pulse-based analysis is 0/1980 (95% CI 0-0.2%). Clinically relevant EMI appeared with oversensing and pacing inhibition but not tachycardia detection. CONCLUSIONS: Bipolar PFA appears safe and does not result in damage to CIEDs or leads. Clinically relevant EMI does occur, but appropriate peri-procedural programming may mitigate this. In vivo studies are needed to confirm our findings.

3.
Artigo em Alemão | MEDLINE | ID: mdl-38771383

RESUMO

Catheter ablation is a standard procedure in modern cardiology. It can significantly improve the quality of life and life expectancy of cardiac arrhythmia patients. Besides cardiac mapping, ablation itself is a fundamental step to successfully treat cardiac arrhythmias. There are various ablation technologies at hand: In traditional radiofrequency (RF) ablation, electrical current flow generates coagulation necrosis. When understanding the biophysical principles of RF ablation, the investigator is capable to adapt lesion geometry and size to the requirements of the procedure and vary them individually. In addition, lesion metric indices evaluate and integrate important parameters such as power, duration, impedance and contact force to standardize and control RF lesions. Cryoablation induces ice crystals within myocardial tissue, which lead to destruction and electrical scarring of the treated tissue. Histologically, cryolesions are well-delineated with preserved tissue architecture and intact endocardium. Pulsed field ablation (PFA) is a novel rising technology, particularly used for pulmonary vein isolation. In contrast to classic thermal technologies (RF and cryoablation), PFA uses pulsed electrical fields to electroporate cardiac tissue and thereby creates damage on a cellular level only.

4.
Clin Res Cardiol ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38261026

RESUMO

BACKGROUND: Data regarding uninterrupted oral anticoagulation in patients with chronic kidney disease (CKD) during catheter ablation for left atrial arrhythmias is limited. This study aimed to evaluate the safety and efficacy of periprocedural uninterrupted direct oral anticoagulants (DOAC) compared with uninterrupted phenprocoumon in patients with CKD undergoing left atrial catheter ablation. METHODS AND RESULTS: We conducted a retrospective single-center study of patients who underwent left atrial catheter ablation between 2016 and 2019 with underlying chronic kidney disease (glomerular filtration rate (GFR) between 15 and 45 ml/min). The primary objective of this study was to investigate whether direct oral anticoagulant (DOAC) therapy or warfarin presents a superior safety profile in patients with chronic kidney disease (CKD) undergoing left atrial catheter ablation. We compared periprocedural complications (arteriovenous fistula, aneurysm, significant hematoma (> 5 cm)) and/or bleeding (drop in hemoglobin of >2 g/dl, pericardial effusion, retroperitoneal bleeding, other bleeding, stroke) between patients receiving either uninterrupted DOAC or warfarin therapy. Secondary analysis included patient baseline characteristics as well as procedural data. A total of 188 patients (female n = 108 (57%), mean age 75.3 ± 8.1 years, mean GFR 36.8 ± 6 ml/min) were included in this study. Underlying arrhythmias were atrial fibrillation (n = 104, 55.3%) and atypical atrial flutter (n = 84, 44.7%). Of these, n = 132 patients (70%) were under a DOAC medication, and n = 56 (30%) were under phenprocoumon. Major groin complications including pseudoaneurysm and/or AV fistula occurred in 8.9% of patients in the phenprocoumon group vs. 11.3% of patients in the DOAC group, which was not statistically significant (p = 0.62). Incidence of cardiac tamponade (2.3% vs. 0%; p = 0.55) and stroke (0% vs. 0%) were low in both DOAC and phenprocoumon groups with similar post-procedural drops in hemoglobin levels (1.1±1 g/dl vs 1.1±0.9 g/dl; p = 0.71). CONCLUSION: The type of anticoagulation had no significant influence on bleeding or thromboembolic events as well as groin complications in this retrospective study. Despite observing an increased rate of groin complications, the uninterrupted use of DOAC or phenprocoumon during left atrial catheter ablation in patients with CKD appears to be feasible and effective.

5.
J Cardiovasc Electrophysiol ; 35(3): 406-414, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38197476

RESUMO

INTRODUCTION: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)-guided software in patients with long-standing persistent AF. METHODS AND RESULTS: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF. First, high-density mapping (78% biatrial) with a multipolar mapping catheter was performed. In addition to pulmonary vein isolation (PVI), ablation of DISPERS was performed aiming at homogenizing, dissecting, isolating, or connecting DISPERS areas to nonconducting anatomical structures. Follow-up contained regular visits at our outpatient clinic at 1, 3, 6, and 12 months including 7-day Holter electrocardiograms. Patients were mainly suffering from long-standing persistent AF (mean AF duration 50.30 ± 54.28 months). Following PVI, ablation of left atrial and right atrial DISPERS areas led to AF cycle length prolongation (mean of 162.0 ± 16.6 to 202.2 ± 21.6 ms after) and AF termination to atrial tachycardia (AT) or sinus rhythm (SR) in 12 patients (24%). No stroke or pericardial effusion occurred; major groin complications (pseudoaneurysm n = 1, atrioventricular fistula n = 1) were detected in two patients. After a blanking period of 6 weeks, recurrence of any atrial arrhythmia was documented in 26 patients (52%). The majority of patients presented with organized AT (n = 15) while AF was present in n = 9 patients and AT/AF was observed in n = 2 patients. Twenty-two patients underwent reablation. During a mean follow-up of 363.14 ± 187.42 days and after an average of 1.46 ± 0.68 procedures, 82% of patients remained in stable SR. CONCLUSION: DISPERS-guided ablation using machine learning software (the Volta VX1 software) in addition to PVI in long-standing persistent AF ablation resulted in high long-term success rates regarding AF and AT elimination. Most arrhythmia recurrences were reentrant AT. After a total of 1.46 ± 0.68 procedures, freedom from AF/AT was 82%. Despite prolonged procedure times complication rates were low. Randomized studies are necessary to evaluate long-term efficacy of dispersion-guided ablation using AI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Inteligência Artificial , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
6.
J Cardiovasc Electrophysiol ; 35(2): 317-327, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38105426

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers. METHODS: We included 179 patients with paroxysmal AF receiving first-time PVI with different ablation technologies: standard RFA (30-40 W/20-30 s, n = 52), power-controlled HPSD (70 W/5-7 s, n = 60), temperature-controlled HPSD (90 W/4 s, n = 32), and PFA (biphasic, bipolar waveform, n = 35). High-sensitivity cardiac troponin T (hs-cTnT), creatine kinase (CK), CK MB isoform (CK-MB), and white blood cell (WBC) count were determined before and after ablation. RESULTS: Baseline characteristics were well-balanced between groups (age 63.1 ± 10.3 years, 61.5% male). Postablation hs-cTnT release was significantly higher with PFA (1469.3 ± 495.0 ng/L), HPSD-70W (1322.3 ± 510.6 ng/L), and HPSD-90W (1441.2 ± 409.9 ng/L) than with standard RFA (1045.9 ± 369.7 ng/L; p < .001). CK and CK-MB release was increased with PFA by 3.4-fold and 5.8-fold, respectively, as compared to standard RFA (p < .001). PFA was associated with the lowest elevation in WBC (Δ1.5 ± 1.5 × 109 /L), as compared to standard RFA (Δ3.8 ± 2.5 × 109 /L, p < .001), HPSD-70W (Δ2.7 ± 1.7 × 109 /L, p = .037), and HPSD-90W (Δ3.6 ± 2.5 × 109 /L, p < .001). CONCLUSION: Among the four investigated ablation technologies, PFA was associated with the highest myocardial injury and the lowest inflammatory reaction.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Creatina Quinase Forma MB , Inflamação/diagnóstico , Veias Pulmonares/cirurgia , Troponina T , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Recidiva
7.
J Clin Med ; 12(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37568301

RESUMO

BACKGROUND: The demand for transvenous lead extraction (TLE) has increased. In line with this, the safety of such procedures has also increased. Traditionally, TLE is performed under resource-intensive general anaesthesia. This study aims to evaluate the safety and outcomes of Cardiologist-lead deep sedation for TLE. METHODS: We retrospectively analysed 328 TLE procedures performed under deep sedation from 2016 to 2019. TLE procedures were performed by experienced electrophysiologists. Sedation was administered by a specifically trained cardiologist (bolus midazolam/fentanyl and propofol infusion). Procedural sedation data including blood pressure, medication administration and sedation time were collected. Complications related to sedation and the operative component of the procedure were analysed retrospectively. RESULTS: The sedation-associated complication rate during TLE was 22.0%. The most common complication (75% of complications) was hypotension requiring noradrenaline, followed by bradycardia requiring atropine (13% of complications). Additionally, the unplanned presence of an anaesthesiologist was needed in one case (0.3%). Deep sedation was achieved with midazolam (mean dose 42.9 ± 26.5 µg/kg), fentanyl (mean dose 0.4 ± 0.6 µg/kg) and propofol (mean dose 3.5 ± 1.2 mg/kg/h). There was no difference in medication dosage between those with a sedation-associated complication and those without. Sedation-associated complications appeared significantly more in patients with reduced LVEF (p = 0.01), renal impairment (p = 0.01) and a higher American Society of Anaesthesiologists (ASA) class (p = 0.01). CONCLUSION: Deep sedation for TLE can be safely performed by a specifically trained cardiologist, with a transition to general anaesthesia required in only 0.3% of cases. We continue to recommend the on-call availability of an anaesthesiologist and cardiac surgeon in case of major complications.

8.
Pacing Clin Electrophysiol ; 46(10): 1170-1181, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37616376

RESUMO

BACKGROUND: The influence of power, duration and contact force (CF) on radiofrequency (RF) lesion formation is well known, whereas data on local impedance (LI) and electrode-tissue-coverage (ETC) is scarce. The objective was to investigate their effect on lesion formation in an ex vivo model. METHODS AND RESULTS: An ex vivo model was developed utilizing cross-sections of porcine heart preparations and a force-sensing, LI-measuring catheter. N = 72 lesion were created systematically varying ETC (minor/full), CF (1-5 g, 10-15 g, 20-25 g) and power (20 W, 30 W, 40 W, 50 W). In minor ETC, the distal tip of the catheter was in electric contact with the tissue, in full ETC the whole catheter tip was embedded within the tissue. Lesion size and all parameters were measured once per second (n = 3320). LI correlated strongly with lesion depth (r = -0.742 for ΔLI; r = 0.781 for %LI-drop). Lesions in full ETC were significantly wider and deeper compared to minor ETC (p < .001) and steam pops were more likely. Baseline LI, ΔLI, and %LI-drop were significantly higher in full ETC (p < .001). In lesions resulting in steam pops, baseline LI, and ΔLI were significantly higher. The influence of CF on lesion size was higher in minor ETC than in full ETC. CONCLUSIONS: ETC is a main determinant of lesion size and occurrence of steam pops. Baseline LI and LI-drop are useful surrogate parameters for real-time assessment of ETC and ΔLI correlates strongly with lesion size.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Ablação por Cateter/métodos , Eletrodos
9.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37410906

RESUMO

Interventional electrophysiology offers a great variety of treatment options to patients suffering from symptomatic cardiac arrhythmia. Catheter ablation of supraventricular and ventricular tachycardia has globally evolved a cornerstone in modern arrhythmia management. Complex interventional electrophysiological procedures engaging multiple ablation tools have been developed over the past decades. Fluoroscopy enabled interventional electrophysiologist throughout the years to gain profound knowledge on intracardiac anatomy and catheter movement inside the cardiac cavities and hence develop specific ablation approaches. However, the application of X-ray technologies imposes serious health risks to patients and operators. To reduce the use of fluoroscopy during interventional electrophysiological procedures to the possibly lowest degree and to establish an optimal protection of patients and operators in cases of fluoroscopy is the main goal of modern radiation management. The present manuscript gives an overview of possible strategies of fluoroscopy reduction and specific radiation protection strategies.


Assuntos
Ablação por Cateter , Exposição à Radiação , Humanos , Arritmias Cardíacas/terapia , Eletrofisiologia Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Fluoroscopia/métodos , Doses de Radiação , Exposição à Radiação/efeitos adversos
12.
Herz ; 48(3): 247-256, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-37130946

RESUMO

The management of ventricular tachycardias (VT), which are often associated with severe cardiac disease, is a challenging clinical task. The structural damage to the myocardium associated with cardiomyopathy is crucial to the occurrence of VT and plays a fundamental role in arrhythmia mechanisms. The goal of catheter ablation is to develop an accurate understanding of the patient-specific arrhythmia mechanism as a first procedural step. As a second step, the ventricular areas that maintain the arrhythmia mechanism can be ablated and thereby electrically inactivated. Catheter ablation thereby enables causal therapy of VT by modifying the areas of the affected myocardium in such a way that VT can no longer be triggered. The procedure is an effective treatment option for affected patients.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Cardiomiopatias/cirurgia , Ventrículos do Coração , Resultado do Tratamento , Ablação por Cateter/efeitos adversos
13.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37067822

RESUMO

AIMS: Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated. METHODS AND RESULTS: A total of 130 CIED patients performed 561 charges of four BEVs and a test vehicle (350 kW charge capacity) using high-power charging stations under continuous 6-lead electrocardiogram monitoring. The charging cable was placed directly over the CIED, and devices were programmed to maximize the chance of EMI detection. Cardiac implantable electronic devices were re-interrogated after patients charged all BEVs and the test vehicle for evidence of EMI. There were no incidences of EMI, specifically no over-sensing, pacing inhibition, inappropriate tachycardia detection, mode switching, or spontaneous reprogramming. The risk of EMI on a patient-based analysis is 0/130 [95% confidence interval (CI) 0%-2%], and the risk of EMI on a charge-based analysis is 0/561 (95% CI 0%-0.6%). The effective magnetic field along the charging cable was 38.65 µT and at the charging station was 77.9 µT. CONCLUSIONS: The use of electric cars with high-power chargers by patients with cardiac devices appears to be safe with no evidence of clinically relevant EMI. Reasonable caution, by minimizing the time spent in close proximity with the charging cables, is still advised as the occurrence of very rare events cannot be excluded from our results.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Campos Eletromagnéticos/efeitos adversos , Fontes de Energia Elétrica , Coração
14.
Eur Heart J Case Rep ; 7(3): ytad118, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36969511

RESUMO

Background: Ventricular tachycardia (VT) originating in the right ventricular outflow tract (RVOT) is the most common form of idiopathic VT. Catheter ablation of right ventricular outflow tract tachycardia (RVOT-VT) is associated with high success rates. However, non-inducibility of VT on electrophysiological (EP) study can severely impact ablation outcome. We describe a novel catheter ablation strategy which proved feasible and safe in a case of highly symptomatic, non-inducible RVOT-VT. Case summary: A 51-year-old male with a history of non-sustained VT (NSVT) was referred to our hospital after two syncopal episodes resulting in collapse. Upon admission, a cluster of monomorphic NSVT (250-270 b.p.m.) resulted in haemodynamic instability and required transfer to the intensive care unit. On twelve-lead electrocardiogram, NSVT showed inferior axis and left bundle branch block, suggestive of RVOT-VT. Diagnostic workup including echocardiography, coronary angiography, and late enhancement computed tomography (CT) revealed no evidence of structural heart disease. On two EP studies, non-inducibility of clinical VT despite repeated ventricular pacing and isoproterenol infusion rendered precise mapping of triggered activity unfeasible. Therefore, a bailout ablation strategy was developed by performing a circumferential electrical RVOT isolation using a 3.5 mm irrigated-tip ablation catheter under the guidance of high-density electroanatomic mapping (CARTO® 3) and CT reconstruction of cardiac anatomy. No procedural complications occurred, and the patient remained arrhythmia-free during a 6-month follow-up period. Discussion: Catheter ablation is a first-line therapy for symptomatic and drug-refractory idiopathic RVOT-VT. Non-inducibility of RVOT-VT represents a relevant limitation for successful ablation which might be overcome by electrical RVOT isolation as a bailout ablation strategy.

15.
Europace ; 25(2): 408-416, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504120

RESUMO

AIMS: This retrospective study sought to compare complication rates and efficacy of power-controlled very high-power short-duration (vHPSD) and conventional catheter ablation in a large cohort of patients with atrial fibrillation (AF). METHODS AND RESULTS: We analyzed 1115 consecutive patients with AF (38.7% paroxysmal, 61.3% persistent) who received first-time catheter ablation at our centre from 2015 to 2021. Circumferential pulmonary vein isolation ± additional substrate ablation using an irrigated-tip catheter was performed with vHPSD (70 W/5-7 s or 60 W/7-10 s) in 574 patients and with conventional power (30-35 W/15-30 s) in 541 patients. Baseline characteristics were well-balanced between groups (mean age 65.1 ± 11.2 years, 63.4% male). The 30-day incidence of cardiac tamponade [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598], pericardial effusion ≥ 10 mm [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598] and transient ischaemic attack [1/574 (0.17%) vs. 2/541 (0.37%), P = 0.529] was not significantly different between vHPSD and conventional ablation. No stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Procedure (122.2 ± 46.8 min vs. 155.0 ± 50.5 min, P < 0.001), radiofrequency (22.4 ± 19.3 min vs. 52.9 ± 22.0 min, P < 0.001), and fluoroscopy (8.1 ± 7.2 vs. 9.2 ± 7.4, P = 0.016) duration were significantly shorter in the vHPSD group. At 12 months follow-up, freedom of any atrial arrhythmia was 44.1% vs. 34.2% (P = 0.010) in persistent AF and 78.1% vs. 70.2% in paroxysmal AF (P = 0.068). CONCLUSION: vHPSD ablation is as safe as conventional ablation and is associated with an improved long-term efficacy in persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
17.
Clin Res Cardiol ; 112(2): 247-257, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35987817

RESUMO

BACKGROUND: The joint contribution of genetic and environmental exposures to noncommunicable diseases is not well characterized. OBJECTIVES: We modeled the cumulative effects of common risk alleles and their prevalence variations with classical risk factors. METHODS: We analyzed mathematically and statistically numbers and effect sizes of established risk alleles for coronary artery disease (CAD) and other conditions. RESULTS: In UK Biobank, risk alleles counts in the lowest (175.4) and highest decile (205.7) of the distribution differed by only 16.9%, which nevertheless increased CAD prevalence 3.4-fold (p < 0.01). Irrespective of the affected gene, a single risk allele multiplied the effects of all others carried by a person, resulting in a 2.9-fold stronger effect size in the top versus the bottom decile (p < 0.01) and an exponential increase in risk (R > 0.94). Classical risk factors shifted effect sizes to the steep upslope of the logarithmic function linking risk allele numbers with CAD prevalence. Similar phenomena were observed in the Estonian Biobank and for risk alleles affecting diabetes mellitus, breast and prostate cancer. CONCLUSIONS: Alleles predisposing to common diseases can be carried safely in large numbers, but few additional ones lead to sharp risk increments. Here, we describe exponential functions by which risk alleles combine interchangeably but multiplicatively with each other and with modifiable risk factors to affect prevalence. Our data suggest that the biological systems underlying these diseases are modulated by hundreds of genes but become only fragile when a narrow window of total risk, irrespective of its genetic or environmental origins, has been passed.


Assuntos
Doença da Artéria Coronariana , Interação Gene-Ambiente , Predisposição Genética para Doença , Humanos , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/genética , Estudo de Associação Genômica Ampla , Polimorfismo de Nucleotídeo Único , Fatores de Risco , Alelos , Reino Unido/epidemiologia , Prevalência
18.
J Clin Med ; 11(22)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36431243

RESUMO

Background: Femoral vascular access using the standard anatomic landmark-guided method is often limited by peripheral artery disease and obesity. We investigated the effect of ultrasound-guided vascular puncture (UGVP) on the rate of vascular complications in patients undergoing catheter ablation for atrial or ventricular arrhythmias. Methods: The data of 479 patients (59% male, mean age 68 years ± 11 years) undergoing catheter ablation for left atrial (n = 426; 89%), right atrial (n = 28; 6%) or ventricular arrhythmias (n = 28; 6%) were analyzed. All patients were on uninterrupted oral anticoagulants and heparin was administered intravenously during the procedure. Femoral access complications were compared between patients undergoing UGVP (n = 320; 67%) and patients undergoing a conventional approach (n = 159; 33%). Complication rates were also compared between patients with a BMI of >30 kg/m2 (n = 136) and patients with a BMI < 30 kg/m2 (n = 343). Results: Total vascular access complications including mild hematomas were n = 37 (7.7%). In the conventional group n = 17 (10.7%) and in the ultrasound (US) group n = 20 (6.3%) total vascular access complications occurred (OR 0.557, 95% CI 0.283−1.096). UGVP significantly reduced the risk of hematoma > 5 cm (OR 0.382, 95% CI 0.148, 0.988) or pseudoaneurysm (OR 0.160, 95% CI 0.032, 0.804). There was no significant difference between the groups regarding retroperitoneal hematomas or AV fistulas (p > 0.05). In patients with BMI > 30 kg/m2, UGVP led to a highly relevant reduction in the risk of total vascular access complications (OR 0.138, 95% CI 0.027, 0.659), hematomas > 5 cm (OR 0.051, 95% CI 0.000, 0.466) and pseudoaneurysms (OR 0.051, 95% CI 0.000, 0.466). Conclusion: UGVP significantly reduces vascular access complications. Patients with a BMI > 30 kg/m2 seem to particularly profit from a UGVP approach.

19.
Herzschrittmacherther Elektrophysiol ; 33(4): 467-475, 2022 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-36342506

RESUMO

In this article, typical characteristics of focal atrial tachycardias are described and a systematic approach regarding diagnostics and treatment options in the field of invasive cardiac electrophysiology (EP) is presented. Subjects of this article include the definition of focal atrial tachycardias, knowledge about localizing the origin of such, and guidance on how to approach an invasive EP study (e.g., administration of medication during the EP study to provoke tachycardias). Further, descriptions will be found on how to localize the origin of focal atrial tachycardias with the help of the 12-lead ECG and invasive three-dimensional mapping to successfully treat focal atrial tachycardias with catheter ablation.


Assuntos
Ablação por Cateter , Taquicardia Atrial Ectópica , Humanos , Ablação por Cateter/métodos , Taquicardia/cirurgia , Eletrocardiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...