Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 12(7)2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35885647

RESUMO

The global spread of antimicrobial resistant (AMR) bacteria represents a considerable public health concern, yet their detection and identification of their resistance mechanisms remain challenging. Optimal diagnostic tests should provide rapid results at low cost to enable implementation in any microbiology laboratory. Lateral flow assays (LFA) meet these requirements and have become essential tools to combat AMR. This review presents the versatility of LFA developed for the AMR detection field, with particular attention to those directly triggering ß-lactamases, their performances, and specific limitations. It considers how LFA can be modified by detecting not only the enzyme, but also its ß-lactamase activity for a broader clinical sensitivity. Moreover, although LFA allow a short time-to-result, they are generally only implemented after fastidious and time-consuming techniques. We present a sample processing device that shortens and simplifies the handling of clinical samples before the use of LFA. Finally, the capacity of LFA to detect amplified genetic determinants of AMR by isothermal PCR will be discussed. LFA are inexpensive, rapid, and efficient tools that are easy to implement in the routine workflow of laboratories as new first-line tests against AMR with bacterial colonies, and in the near future directly with biological media.

2.
Diagnostics (Basel) ; 10(10)2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-32998433

RESUMO

We have developed a lateral flow immunoassay (LFIA), named NG-Test CTX-M MULTI (NG-Test), to detect group 1, 2, 8, 9, 25 CTX-M producers from agar plates and from positive blood cultures in less than 15 min. The NG-Test was validated retrospectively on 113 well-characterized enterobacterial isolates, prospectively on 102 consecutively isolated ESBL-producers from the Bicêtre hospital and on 100 consecutive blood cultures positive with a gram-negative bacilli (GNB). The NG-Test was able to detect all CTX-M producers grown on the different agar plates used in clinical microbiology laboratories. No false positive nor negative results were observed. Among the 102 consecutive ESBL isolates, three hyper mucous isolates showed an incorrect migration leading to invalid results (no control band). Using an adapted protocol, the results could be validated. The NG-Test detected 99/102 ESBLs as being CTX-Ms. Three SHV producers were not detected. Among the 100 positive blood cultures with GNB tested 10/11 ESBL-producers were detected (8 CTX-M-15, 2 CTX-M-27). One SHV-2-producing-E. cloacae was missed. The NG-Test CTX-M MULTI showed 100% sensitivity and specificity with isolates cultured on agar plates and was able to detect 98% of the ESBL-producers identified in our clinical setting either from colonies or from positive blood cultures.

3.
Microorganisms ; 8(1)2020 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-31940771

RESUMO

Rapid identification of the causative agent of hospital-acquired pneumonia (HAP) will allow an earlier administration of a more appropriate antibiotic and could improve the outcome of these patients. The aim of this study was to develop a rapid protocol to identify the main microorganisms involved in HAP by loop-mediated isothermal amplification (LAMP) directly from respiratory samples. First of all, a rapid procedure (<30 min) to extract the DNA from bronchoalveolar lavage (BAL), endotracheal aspirate (EA) or bronchoaspirate (BAS) was set up. A specific LAMP for Staphylococcus aureus, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Stenotrophomonas maltophilia and Acinetobacter baumannii was performed with the extracted solution at 65 °C for 30-40 min. Overall, 58 positive BAL and 83 EA/BAS samples were tested. The limits of detection varied according to the microorganism detected. Validation of the LAMP assay with BAL samples showed that the assay was 100% specific and 86.3% sensitive (positive predictive value of 100% and a negative predictive value of 50%) compared with culture. Meanwhile for BAS/EA samples, the assay rendered the following statistical parameters: 100% specificity, 94.6% sensitivity, 100% positive predictive value and 69.2% negative predictive value. The turnaround time including sample preparation and LAMP was circa 1 h. LAMP method may be used to detect the most frequent bacteria causing HAP. It is a simple, cheap, sensitive, specific and rapid assay.

4.
J Clin Microbiol ; 57(5)2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30842227

RESUMO

Colistin has become a last-resort antibiotic for the treatment of infections caused by highly drug-resistant Gram-negative bacteria. Moreover, it has been widely used in the livestock sector. As a consequence, colistin resistance is emerging worldwide. Among the colistin resistance mechanisms, the spread of the plasmid-encoded colistin resistance gene mcr-1 (mostly in Escherichia coli) is of particular concern due to its increased transferability compared to that of chromosome-encoded resistance. The early detection of MCR-1-producing bacteria is essential to prevent further spread and provide appropriate antimicrobial therapy. Lateral flow immunoassays (LFIAs) were manufactured with selected monoclonal antibodies. A collection of 177 human and 121 animal enterobacterial isolates was tested in a multicentric study. One bacterial colony grown on agar plates was suspended in extraction buffer and dispensed on the cassette. Migration was allowed for 15 min, and the results were monitored by the appearance of a specific band. The positive results showed a pink line resulting in an unambiguous interpretation. All MCR-1-producing isolates were found to be positive by the LFIA, and no false-negative results were observed. Three out of four MCR-2-producing isolates were also found to be positive. Our test does not detect MCR-3-, MCR-4-, or MCR-5-producing isolates. LFIA allows the detection of MCR-1 with 100% sensitivity and 98% specificity. This test is fast, sensitive, specific, easy to use, and cost-effective and can therefore be implemented in any microbiology laboratory worldwide. LFIA is a major tool for the rapid detection and monitoring of MCR-1 producers in humans and animals.


Assuntos
Ação Capilar , Enterobacteriaceae/isolamento & purificação , Proteínas de Escherichia coli/análise , Imunoensaio , Animais , Antibacterianos/farmacologia , Proteínas de Bactérias/análise , Colistina/farmacologia , Farmacorresistência Bacteriana , Enterobacteriaceae/enzimologia , Infecções por Enterobacteriaceae/microbiologia , Humanos , Testes de Sensibilidade Microbiana , Plasmídeos/genética
5.
J Antimicrob Chemother ; 73(4): 909-915, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29365094

RESUMO

Objectives: The global spread of carbapenemase-producing Enterobacteriaceae represents a substantial challenge in clinical practice and rapid and reliable detection of these organisms is essential. The aim of this study was to develop and validate a lateral flow immunoassay (Carba5) for the detection of the five main carbapenemases (KPC-, NDM-, VIM- and IMP-type and OXA-48-like). Methods: Carba5 was retrospectively and prospectively evaluated using 296 enterobacterial isolates from agar culture. An isolated colony was suspended in extraction buffer and then loaded on the manufactured Carba5. Results: All 185 isolates expressing a carbapenemase related to one of the Carba5 targets were correctly and unambiguously detected in <15 min. All other isolates gave negative results except those producing OXA-163 and OXA-405, which are considered low-activity carbapenemases. No cross-reaction was observed with non-targeted carbapenemases, ESBLs, AmpCs or oxacillinases (OXA-1, -2, -9 and -10). Overall, this assay reached 100% sensitivity and 95.3% (retrospectively) to 100% (prospectively) specificity. Conclusions: Carba5 is efficient, rapid and easy to implement in the routine workflow of a clinical microbiology laboratory for confirmation of the five main carbapenemases encountered in Enterobacteriaceae.


Assuntos
Proteínas de Bactérias/análise , Enterobacteriáceas Resistentes a Carbapenêmicos/isolamento & purificação , Infecções por Enterobacteriaceae/microbiologia , Imunoensaio/métodos , beta-Lactamases/análise , Proteínas de Bactérias/imunologia , Enterobacteriáceas Resistentes a Carbapenêmicos/enzimologia , Reações Cruzadas , Sensibilidade e Especificidade , Fatores de Tempo , beta-Lactamases/imunologia
6.
J Clin Microbiol ; 55(7): 2018-2029, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28404680

RESUMO

The global spread of carbapenemase-producing Enterobacteriaceae (CPE) that are often resistant to most, if not all, classes of antibiotics is a major public health concern. The NDM-1 carbapenemase is among the most worrisome carbapenemases given its rapid worldwide spread. We have developed and evaluated a lateral flow immunoassay (LFIA) (called the NDM LFIA) for the rapid and reliable detection of NDM-like carbapenemase-producing Enterobacteriaceae from culture colonies. We evaluated the NDM LFIA using 175 reference enterobacterial isolates with characterized ß-lactamase gene content and 74 nonduplicate consecutive carbapenem-resistant clinical isolates referred for expertise to the French National Reference Center (NRC) for Antibiotic Resistance during a 1-week period (in June 2016). The reference collection included 55 non-carbapenemase producers and 120 carbapenemase producers, including 27 NDM producers. All 27 NDM-like carbapenemase producers of the reference collection were correctly detected in less than 15 min by the NDM LFIA, including 22 strains producing NDM-1, 2 producing NDM-4, 1 producing NDM-5, 1 producing NDM-7, and 1 producing NDM-9. All non-NDM-1 producers gave a negative result with the NDM LFIA. No cross-reaction was observed with carbapenemases (VIM, IMP, NDM, KPC, and OXA-48-like), extended-spectrum ß-lactamases (ESBLs) (TEM, SHV, and CTX-M), AmpCs (CMY-2, DHA-2, and ACC-1), and oxacillinases (OXA-1, -2, -9, and -10). Similarly, among the 74 referred nonduplicate consecutive clinical isolates, all 7 NDM-like producers were identified. Overall, the sensitivity and specificity of the assay were 100% for NDM-like carbapenemase detection with strains cultured on agar. The NDM LFIA was efficient, rapid, and easy to implement in the routine workflow of a clinical microbiology laboratory for the confirmation of NDM-like carbapenemase-producing Enterobacteriaceae.


Assuntos
Enterobacteriáceas Resistentes a Carbapenêmicos/isolamento & purificação , Cromatografia de Afinidade/métodos , beta-Lactamases/análise , Enterobacteriáceas Resistentes a Carbapenêmicos/enzimologia , Infecções por Enterobacteriaceae/microbiologia , Humanos , Sensibilidade e Especificidade , Fatores de Tempo
7.
Org Biomol Chem ; 6(17): 3065-78, 2008 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-18698464

RESUMO

A convenient, versatile and straightforward synthesis of a novel heterotrifunctional peptide-based linker molecule is described. This generic bio-labelling reagent contains an amine-reactive N-hydroxysuccinimidyl carbamate moiety, an aldehyde/ketone-reactive aminooxy group and a thiol group with a propensity to form urea, oxime and thioether linkages respectively. The full chemical orthogonality between the free aminooxy and thiol functionalities was demonstrated through the preparation of a fluorescent reagent suitable for the selective staining of a carboxaldehyde-modified surface by means of oxime ligation. The absence of reactivity of these two functions toward the nucleophile-sensitive active carbamate was obtained by using temporary aminooxy- and thiol-protecting groups removable under mild conditions. The utility of the linker molecule to cross-link three different molecular partners has been illustrated by the preparation of fluorescent tripod-functionalised surfaces which may be useful in developing new peptide microarrays and related immunosensors.


Assuntos
Reagentes de Ligações Cruzadas/síntese química , Corantes Fluorescentes/química , Fluorimunoensaio/métodos , Substância P/química , Substância P/metabolismo , Cromatografia Líquida de Alta Pressão , Reagentes de Ligações Cruzadas/química , Transferência Ressonante de Energia de Fluorescência , Substância P/imunologia , Compostos de Sulfidrila/química
8.
Anal Biochem ; 377(2): 182-8, 2008 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-18384739

RESUMO

Staphylococcus enterotoxin B (SEB) is one of several toxins produced by the gram positive bacterium Staphylococcus aureus. SEB is a major cause of food poisoning and represents a significant biological threat with regard to bioterrorism. A rapid, sensitive, and specific method is required to monitor food and water in cases of both natural and intentional contamination by this toxin. This report presents an improved immunochromatographic test (ICT) using immunoliposomes as label for the detection of SEB. For the first time in an ICT, the signal generated by the sulforhodamine B encapsulated into immunoliposomes was measured by fluorescence, allowing a 15-fold increase in sensitivity compared with that for visual detection of colored labels. The ICT was completed within 30 min, providing a limit of detection close to 20 pg/ml in buffer and showing no cross-reactivity with the other major toxin of the bacterium, Staphylococcus enterotoxin A. This sensitivity was retained when analyzing SEB spiked in various alimentary matrices, mimicking contaminated foods. Due to the use of fluorescent immunoliposomes as label, the present assay offers the inherent simplicity and speed of a dipstick assay while providing detection of low levels of SEB in real samples.


Assuntos
Antígenos de Bactérias/análise , Enterotoxinas/análise , Corantes Fluorescentes/química , Imunoensaio/métodos , Lipossomos/química , Antígenos de Bactérias/imunologia , Enterotoxinas/imunologia , Corantes Fluorescentes/análise , Microbiologia de Alimentos , Sensibilidade e Especificidade
9.
Emerg Infect Dis ; 14(4): 608-16, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18394279

RESUMO

The bovine spongiform encephalopathy (BSE) agent has been transmitted to humans, leading to variant Creutzfeldt-Jakob disease. Sheep and goats can be experimentally infected by BSE and have been potentially exposed to natural BSE; however, whether BSE can be transmitted to small ruminants is not known. Based on the particular biochemical properties of the abnormal prion protein (PrPsc) associated with BSE, and particularly the increased degradation induced by proteinase K in the N terminal part of PrPsc, we have developed a rapid ELISA designed to distinguish BSE from other scrapie strains. This assay clearly discriminates experimental ovine BSE from other scrapie strains and was used to screen 260 transmissible spongiform encephalopathy (TSE)-infected small ruminant samples identified by the French active surveillance network (2002/2003). In this context, this test has helped to identify the first case of natural BSE in a goat and can be used to classify TSE isolates based on the proteinase K sensitivity of PrPsc.


Assuntos
Encefalopatia Espongiforme Bovina/diagnóstico , Ensaio de Imunoadsorção Enzimática/veterinária , Príons/classificação , Scrapie/diagnóstico , Animais , Bovinos , Ensaio de Imunoadsorção Enzimática/métodos , Doenças das Cabras/diagnóstico , Cabras , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...