1.
Sensors (Basel) ; 24(6)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38544167

RESUMO

There is a growing interest in wearable inertial sensors to monitor and analyze the movements of pregnant women. The noninvasive and discrete nature of these sensors, integrated into devices accumulating large datasets, offers a unique opportunity to study the dynamic changes in movement patterns during the rapid physical transformations induced by pregnancy. However, the final cut of the third trimester of pregnancy, particularly the first stage of labor up to delivery, remains underexplored. The growing popularity of "walking epidural", a neuraxial analgesia method allowing motor function preservation, ambulation, and free movement throughout labor and during delivery, opens new opportunities to study the biomechanics of labor using inertial sensors. Critical research gaps exist in parturient fall prediction and detection during walking epidural and understanding pain dynamics during labor, particularly in the presence of pelvic girdle pain. The analysis of fetal descent, upright positions, and their relationship with dynamic pelvic movements facilitated by walking during labor is another area where inertial sensors can play an interesting role. Moreover, as contemporary obstetrics advocate for less restricted or non-restricted movements during labor, the role of inertial sensors in objectively measuring the quantity and quality of women's movements becomes increasingly important. This includes studying the impact of epidural analgesia on maternal mobility, walking patterns, and associated obstetrical outcomes. In this paper, the potential use of wearable inertial sensors for gait analysis in the first stage of labor is discussed.


Assuntos
Analgesia Epidural , Trabalho de Parto , Dispositivos Eletrônicos Vestíveis , Gravidez , Feminino , Humanos , Analgesia Epidural/métodos , Caminhada , Dor
2.
J Clin Anesth ; 94: 111404, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38290374

RESUMO

STUDY OBJECTIVE: Interpretation of gastric ultrasound relies on the use of a clinical algorithm that combines qualitative analysis of the gastric antrum contents with the calculation of the volume of fluid contents. This reference method may be difficult to apply in the parturient. We therefore aimed to assess the diagnostic accuracy of a simple qualitative assessment in the supine position for the diagnosis of high-risk gastric contents in the parturient. We also assessed the diagnostic accuracy of a composite scale and another clinical algorithm based on a mathematical model different to that used in the reference method. DESIGN: Prospective observational cohort study. SETTING: University hospital, Lyon, France. PATIENTS: Adult women admitted to the delivery room. INTERVENTIONS: Qualitative and quantitative gastric ultrasound examination within the first hour following admission. MEASUREMENTS: With respect to the reference method, the diagnostic accuracy of a simple qualitative assessment for the diagnosis of high-risk gastric contents was assessed. The diagnostic accuracy of a composite scale and another clinical algorithm, and the agreement between each approach were also assessed. MAIN RESULTS: A total of 235 parturients were included and analyzed. The simple qualitative assessment led to conclusive ultrasound assessment in 233 (99%) women, while the reference method led to conclusive assessment in 213 (91%) women (P < 0.05). The sensitivity and the specificity of the simple qualitative assessment were 97% (95%CI: 93 to 99%) and 96% (95%CI: 90 to 99%), respectively. These were not significantly different from those of the composite scale and the clinical algorithm. The four approaches showed almost perfect agreement with each other. CONCLUSIONS: These results suggest that simple qualitative assessment may be useful in clinical practice to help the anesthesiologist in the assessment of gastric contents status and risk of aspiration.


Assuntos
Antro Pilórico , Estômago , Adulto , Humanos , Feminino , Masculino , Estudos Prospectivos , Estômago/diagnóstico por imagem , Antro Pilórico/diagnóstico por imagem , Ultrassonografia/métodos , Aspiração Respiratória
3.
Br J Anaesth ; 132(3): 553-561, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38177007

RESUMO

BACKGROUND: This multicentre prospective observational study sought to determine the prevalence and the factors associated with high-risk gastric contents in women admitted to the maternity unit for childbirth, and to identify the clinical situations in which ultrasound assessment of gastric contents would be most helpful (i.e. when the prevalence of high-risk gastric contents is close to 50%). METHODS: Ultrasound assessments of gastric contents were performed within the first hour after admission to the maternity unit. The prevalence of high-risk gastric contents was calculated and variables associated with high-risk gastric contents were identified using logistic regression analyses. RESULTS: A total of 1003 parturients were analysed. The prevalence of high-risk gastric contents was 70% (379/544; 95% confidence interval: 66-74%) in women admitted in spontaneous labour and 65% (646/1003; 95% confidence interval: 61-67%) in the whole cohort. Lower gestational age, increased fasting duration for solids, and elective Caesarean delivery were independently associated with reduced likelihood of high-risk gastric contents. In women admitted in spontaneous labour and in the whole cohort, the prevalence of high-risk gastric contents ranged from 85% to 86% for fasting duration for solids <6 h, 63%-68% for fasting 6-8 h, 54%-55% for fasting 8-12 h, and 47%-51% for fasting ≥12 h. CONCLUSIONS: Around two-thirds of parturients had high-risk gastric contents within the first hour after admission to the maternity unit. Our results suggest that gastric emptying for solids continues in labouring women, and that gastric ultrasound would be most helpful when fasting duration is ≥8 h.


Assuntos
Parto Obstétrico , Trabalho de Parto , Humanos , Feminino , Gravidez , Estudos Prospectivos , Prevalência , Parto
6.
Anaesth Crit Care Pain Med ; 42(6): 101302, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37709198

RESUMO

BACKGROUND: This study aimed to collect obstetric anesthesia practice and patient-reported outcomes as an update to the last French Obstetric Anesthesia survey from 1996. METHODS: Maternity units were randomly selected across France and surveyed for 7 consecutive days from February, 2016, to January, 2017. Data was gathered prospectively by questionnaires filled out by patients and anesthesia providers. RESULTS: There were 1885 questionnaires received from 56 units, with 379 cesarean delivery (CD) and 1506 vaginal delivery (VD) cases analyzed. The overall neuraxial labor analgesia (NLA) rate was 82.5% (95% CI [82.4-82.6]), with 70.3% (95% CI [71.4-71.6]) receiving automated administration (PCEA/PIEB). NLA was effective throughout labor in 68.2% of cases, however, severe pain was reported by 29.4% of patients. The overall rate of alternative approaches for labor analgesia was 19.5% (95%CI [19.2-19.7]). Obesity (OR 2.8; 95% CI [1.0-7.5], p < 0.04) and delivery in level I units (OR 0.6; 95% CI [0.5-0.9], p < 0.01) were associated with severe pain during VD. Satisfaction was found to be similar in patients delivering with or without NLA. The incidence of pain during CD was similar in scheduled versus non-scheduled CD. Failure of NLA during CD was associated with severe pain (OR 10.0; 95% CI [3.1-31.9], p < 0.01) and dissatisfaction (OR 26.2; 95% CI [3.0-225.1], p < 0.01). CONCLUSION: Despite the high NLA rate in France, a significant proportion of women experience severe pain during labor and delivery. This study emphasizes the need for further practice guidelines in obstetric anesthesia to ensure optimal pain management and improve patients' experience during childbirth. CLINICALTRIALS: govNCT02853890.


Assuntos
Anestesia Obstétrica , Dor do Parto , Feminino , Humanos , Gravidez , Analgésicos , Cesárea , Estudos Transversais , Parto Obstétrico , Dor do Parto/tratamento farmacológico
9.
Anaesth Crit Care Pain Med ; 42(4): 101264, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37295649

RESUMO

OBJECTIVE: The French Society of Anesthesiology and Intensive Care Medicine [Société Française d'Anesthésie et de Réanimation (SFAR)] aimed at providing guidelines for the implementation of perioperative optimization programs. DESIGN: A consensus committee of 29 experts from the SFAR was convened. A formal conflict-of-interest policy was developed at the outset of the process and enforced throughout. The entire guidelines process was conducted independently of any industry funding. The authors were advised to follow the principles of the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system to guide assessment of quality of evidence. METHODS: Four fields were defined: 1) Generalities on perioperative optimization programs; 2) Preoperative measures; 3) Intraoperative measures and; 4) Postoperative measures. For each field, the objective of the recommendations was to answer a number of questions formulated according to the PICO model (population, intervention, comparison, and outcomes). Based on these questions, an extensive bibliographic search was carried out using predefined keywords according to PRISMA guidelines and analyzed using the GRADE® methodology. The recommendations were formulated according to the GRADE® methodology and then voted on by all the experts according to the GRADE grid method. As the GRADE® methodology could have been fully applied for the vast majority of questions, the recommendations were formulated using a "formalized expert recommendations" format. RESULTS: The experts' work on synthesis and application of the GRADE® method resulted in 30 recommendations. Among the formalized recommendations, 19 were found to have a high level of evidence (GRADE 1±) and ten a low level of evidence (GRADE 2±). For one recommendation, the GRADE methodology could not be fully applied, resulting in an expert opinion. Two questions did not find any response in the literature. After two rounds of rating and several amendments, strong agreement was reached for all the recommendations. CONCLUSIONS: Strong agreement among the experts was obtained to provide 30 recommendations for the elaboration and/or implementation of perioperative optimization programs in the highest number of surgical fields.


Assuntos
Anestesiologia , Cuidados Críticos , Adulto , Humanos
10.
Anaesth Crit Care Pain Med ; 42(6): 101269, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37364852

RESUMO

INTRODUCTION: Spinal anesthesia with intrathecal morphine (ITM) is a common anesthesia technique for cesarean delivery. The hypothesis was that the addition of ITM will delay micturition in women undergoing cesarean delivery. METHODS: Fifty-six ASA physical status I and II women scheduled to undergo elective cesarean delivery under spinal anesthesia were randomized to the PSM group (50 mg prilocaine + 2.5 mcg sufentanil + 100 mcg morphine; n = 30) or PS group (50 mg prilocaine + 2.5 mcg sufentanil; n = 24). The patients in the PS group received a bilateral transverse abdominal plane (TAP) block. The primary outcome was the effect of ITM on the time to micturition and the secondary outcome was the need for bladder re-catheterization. RESULTS: The time to first urge to urinate (8 [6-10] hours in the PSM group versus 6 [4-6] hours in the PS group) and the time to first micturition (10 [8-12] hours in the PSM group versus 6 [6-8] hours in the PS group) were significantly (p < 0.001) prolonged in the PSM group. Two patients in the PSM group met the 800 mL criterium for urinary catheterization after 6 and 8 h respectively. CONCLUSION: This study is the first randomized trial to demonstrate that the addition of ITM to the standardized mixture of prilocaine and sufentanil significantly delayed micturition.


Assuntos
Morfina , Sufentanil , Gravidez , Humanos , Feminino , Bexiga Urinária , Analgésicos Opioides , Dor Pós-Operatória , Prilocaína , Método Duplo-Cego
11.
Acta Anaesthesiol Scand ; 67(9): 1202-1209, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37325856

RESUMO

BACKGROUND: It has been reported that qualitative ultrasound assessment performed in the semi-upright position had high sensitivity to detect gastric fluid volume >1.5 mL.kg-1 . Nevertheless, the diagnostic accuracy of qualitative assessment for the diagnosis of empty stomach (fluid volume <0.8 mL.kg-1 ) has not been assessed. We aimed to assess the diagnostic accuracy of simple qualitative ultrasound assessment with and without head-of-bed elevation to 45° for the diagnosis of an empty stomach. We also aimed to determine the diagnostic accuracy of a composite ultrasound scale and clinical algorithm. METHODS: We performed a supplementary analysis of a prospective observer-blind randomized crossover trial in which adult fasting volunteers attended two distinct sessions, with the head-of-bed angled either at 0° or 45°, in a randomized order. Three tests were performed within each session, each corresponding to a different (either 0, 50, 100, 150 or 200 mL) and randomized volume of water; the same volumes were ingested in both sessions, in a randomized order. Ultrasounds were performed 3 min after water ingestion, blindly to the volume ingested. RESULTS: We included 20 volunteers in whom 120 measurements were analyzed. The sensitivity and specificity of the qualitative assessment in the semirecumbent position were 93% (95% CI: 68-100) and 89% (95% CI: 76-96), respectively. The composite scale and clinical algorithm did not have better diagnostic accuracy than the qualitative assessment performed with head-of-bed elevation. Without head-of-bed elevation, the clinical algorithm had significantly higher specificity (98% [95% CI: 88-100]) than qualitative assessment (67% [95% CI: 51-80]; p < 0.05). CONCLUSION: These results suggest that qualitative assessment in the semirecumbent position had high diagnostic accuracy for the diagnosis of fluid volume <0.8 mL.kg-1 ; this method can be used in clinical practice for reliable diagnosis of empty stomach.


Assuntos
Jejum , Estômago , Adulto , Humanos , Estudos Prospectivos , Estudos Cross-Over , Estômago/diagnóstico por imagem , Ultrassonografia/métodos
14.
Anaesth Crit Care Pain Med ; 42(3): 101194, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36640908

RESUMO

BACKGROUND: To date, the use of the plethysmographic variability index (PVI) has not been recommended to guide fluid management in the paediatric surgical population. This systematic review and meta-analysis aimed to summarise available evidence about the diagnostic accuracy of digital PVI to predict fluid responsiveness in mechanically ventilated children. METHODS: We searched the Pubmed, Embase and Web of Science databases, from inception to January 2022, to identify all relevant studies that investigated the ability of the PVI recorded at the finger to predict fluid responsiveness in mechanically ventilated children. Using a random-effects model, we calculated pooled values of diagnostic odds ratio, sensitivity, and specificity of PVI to predict the response to fluid challenge. RESULTS: Eight studies met the inclusion criteria with a total of 283 patients and 360 fluid challenges. All the studies were carried out in a surgical setting. The area under the summary receiver operating characteristic curve of PVI to predict fluid responsiveness was 0.82. The pooled sensitivity, specificity, and diagnostic odds ratio of PVI for the overall population were 72.4% [95% CI: 65.3-78.7], 65.9% [58.5-72.8], and 9.26 [5.31-16.16], respectively. CONCLUSION: Our results suggest that digital PVI is a reliable predictor for fluid responsiveness in mechanically ventilated children in the perioperative setting. The diagnostic performance of digital PVI reported in our work for discrimination between responders and non-responders to the fluid challenge was however not as high as previously reported in the adult population.


Assuntos
Hidratação , Respiração Artificial , Adulto , Humanos , Criança , Hidratação/métodos , Respiração Artificial/métodos , Curva ROC , Monitorização Intraoperatória/métodos , Testes Diagnósticos de Rotina , Hemodinâmica/fisiologia
15.
Anesth Analg ; 136(1): 101-110, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35986678

RESUMO

BACKGROUND: Inhaled halogenated anesthetics are responsible for half of operating room total greenhouse gas emissions. Sustainable anesthesia groups were set up in 4 Lyon, France, university hospitals (Hospices Civils de Lyon) in January 2018 and have supported a specific information campaign about the carbon footprint related to the use of inhaled halogenated anesthetics in June 2019. We aimed to assess whether implementing such information campaigns was associated with a decrease in the carbon footprint related to inhaled halogenated anesthetics. METHODS: This retrospective cohort study was conducted from January 1, 2015, to February 29, 2020, in 4 hospitals of the Hospices Civils de Lyon in France. Information meetings on sustainable anesthesia practices were organized by sustainable anesthesia groups that were set up in January 2018. In addition, a specific information campaign about the carbon footprint related to inhaled halogenated anesthetics was conducted in June 2019; it was followed by a questionnaire to be completed online. The monthly purchase of sevoflurane, desflurane, and propofol was recorded, and the estimated monthly carbon footprint from desflurane- and sevoflurane-related perioperative emissions was calculated. The interrupted time-series data from January 2015 to February 2020 were analyzed by segmented regression, considering both interventions (setting up of the sustainable anesthesia groups and specific information campaign) in the analysis and adjusting for 2 confounding factors (seasonality of the data and number of general anesthesia uses). RESULTS: Among the 641 anesthesia providers from the study hospitals, 121 (19%) attended the information meetings about the carbon footprint of inhaled halogenated anesthetics, and 180 (28%) completed the questionnaire. The anesthetic activity from all 641 providers was considered in the analysis. After the sustainable anesthesia groups were set up, the carbon footprint of sevoflurane and desflurane started decreasing: the slope significantly changed ( P < .01) and became significantly negative, from -0.27 (95% confidence interval [CI], -1.08 to 0.54) tons.month -1 to -14.16 (95% CI, -16.67 to -11.65) tons.month -1 . After the specific information campaign, the carbon footprint kept decreasing, with a slope of -7.58 (95% CI, -13.74 to -1.41) tons.month -1 ( P = .02), which was not significantly different from the previous period ( P = .07). CONCLUSIONS: The setup of the sustainable anesthesia groups was associated with a dramatic reduction in the carbon footprint related to halogenated anesthetics. These results should encourage health care institutions to undertake information campaigns toward anesthesia providers so that they also take into account the environmental impact in the choice of anesthetic drugs, in addition to the benefits for the patient and economic concerns.


Assuntos
Anestésicos Inalatórios , Isoflurano , Éteres Metílicos , Humanos , Sevoflurano , Desflurano , Pegada de Carbono , Estudos Retrospectivos , Anestesia por Inalação
16.
Eur J Anaesthesiol ; 40(3): 190-197, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36204923

RESUMO

BACKGROUND: Pre-operative anxiety occurs in 18 to 60% of children undergoing surgery and results in poor outcomes. Nonpharmacological methods of distraction are effective in alleviating peri-operative anxiety. In our institution, ride-on electric cars (ride-on e-cars) are routinely used by children undergoing ambulatory surgery as a mean of nonpharmacological distraction. OBJECTIVES: The aim of this study is to assess the effect of pre-operative distraction with ride-on e-cars on children's pre-operative anxiety when undergoing elective ambulatory surgery. DESIGN: This was a prospective, randomised, controlled, open-label study. SETTING: The study was carried out from September 2019 to September 2021 in the ambulatory paediatric surgery unit of our teaching hospital, in Marseille, France. PATIENTS: Children aged 2 to 10 years and weighing less than 35 kg undergoing elective ambulatory surgery were eligible. One hundred and fifteen children were included, 56 in the control group and 59 in the intervention group. INTERVENTION: Children in the control group were transported from the operating room (OR) waiting area to the OR using a trolley, while children in the intervention group used the ride-on e-cars, without pharmacological premedication or parental presence. MAIN OUTCOME MEASURES: The primary outcome was pre-operative anxiety at the end of the transport (prior going into the OR assessed by the modified Yale Preoperative Anxiety Score Short Form (mYPAS-SF). Secondary outcomes were the anxiety levels in children over time, as well as postoperative pain and agitation assessed with the Face Legs Activity Cry Consolability (FLACC) and Paediatric Anaesthesia Emergence Delirium (PAED) scales, respectively. RESULTS: The mYPAS-SF anxiety scores did not differ between the control group and the intervention group (39 ±â€Š19 vs. 37 ±â€Š21, P  = 0.574). The secondary outcomes were similar between the two groups. CONCLUSIONS: Our randomised controlled trial showed that the use of ride-on e-cars did not alter pre-operative anxiety as compared with standard transport in children undergoing elective ambulatory surgery. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03961581.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Automóveis , Humanos , Criança , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Procedimentos Cirúrgicos Ambulatórios/métodos , Estudos Prospectivos , Cuidados Pré-Operatórios/métodos , Ansiedade/etiologia , Ansiedade/prevenção & controle
17.
Turk J Anaesthesiol Reanim ; 50(6): 424-429, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36511491

RESUMO

OBJECTIVE: In France, healthcare facilities account for 7% of greenhouse gas emissions and 3.5% of total waste generation. Operating rooms generate 30% of hospital waste and hence should be a primary focus of environmental sustainability initiatives. The aim of this study was to evaluate environmentally sustainable anaesthesiology practices in France in 2020 and understand the barriers to their adoption. METHODS: An anonymous survey of 28 questions was published online. The website did not record participants' IP addresses. The survey's link was sent by email to anaesthesiologist and anaesthesia nurse members of the French Society of Anesthesia and Intensive Care Medecine (SFAR), in February and June 2020. The survey was closed in August 2020. RESULTS: Of the 10 877 recipients, 1092 (10%) responded to the questionnaire. Waste sorting was organized in 69% of respondents' workplaces (691/1007), and 90% (793/879) of respondents stated that they most often followed the instructions. Sixty-five percent (659/1007) of respondents avoided using the most polluting anaesthetic gases. Thirty-nine percent of respondents (417/1064) had already received environmental sustainability training and 73% (705/972) stated that they wanted more training. The main barriers to the adoption of recycling identified by respondents were staff training (by 70% of respondents, 691/993), budget constraints (66%, 652/993), and a lack of administrative support (60%, 602/993). CONCLUSION: French anaesthesiologists and anaesthesia nurses who responded to the survey are environmentally aware and want to improve sustainable practices in the operating room. More widespread adoption could be achieved by offering training to all healthcare professionals and administrative staff and by creating local environmental focus groups to coordinate actions.

19.
Front Pediatr ; 10: 921863, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35874585

RESUMO

Introduction: Point-of-care ultrasound (POCUS) use is increasing in pediatric clinical settings. However, gastric POCUS is rarely used, despite its potential value in optimizing the diagnosis and management in several clinical scenarios (i.e., assessing gastric emptying and gastric volume/content, gastric foreign bodies, confirming nasogastric tube placement, and hypertrophic pyloric stenosis). This review aimed to assess how gastric POCUS may be used in acute and critically ill children. Materials and Methods: An international expert group was established, composed of pediatricians, pediatric intensivists, anesthesiologists, radiologists, nurses, and a methodologist. A scoping review was conducted with an aim to describe the use of gastric POCUS in pediatrics in acute and critical care settings. A literature search was conducted in three databases, to identify studies published between 1998 and 2022. Abstracts and relevant full texts were screened for eligibility, and data were extracted, according to the JBI methodology (Johanna Briggs Institute). Results: A total of 70 studies were included. Most studies (n = 47; 67%) were conducted to assess gastric emptying and gastric volume/contents. The studies assessed gastric volume, the impact of different feed types (breast milk, fortifiers, and thickeners) and feed administration modes on gastric emptying, and gastric volume/content prior to sedation or anesthesia or during surgery. Other studies described the use of gastric POCUS in foreign body ingestion (n = 6), nasogastric tube placement (n = 5), hypertrophic pyloric stenosis (n = 8), and gastric insufflation during mechanical ventilatory support (n = 4). POCUS was performed by neonatologists, anesthesiologists, emergency department physicians, and surgeons. Their learning curve was rapid, and the accuracy was high when compared to that of the ultrasound performed by radiologists (RADUS) or other gold standards (e.g., endoscopy, radiography, and MRI). No study conducted in critically ill children was found apart from that in neonatal intensive care in preterms. Discussion: Gastric POCUS appears useful and reliable in a variety of pediatric clinical settings. It may help optimize induction in emergency sedation/anesthesia, diagnose foreign bodies and hypertrophic pyloric stenosis, and assist in confirming nasogastric tube placement, avoiding delays in obtaining confirmatory examinations (RADUS, x-rays, etc.) and reducing radiation exposure. It may be useful in pediatric intensive care but requires further investigation.

20.
J Clin Anesth ; 81: 110919, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35792453

RESUMO

STUDY OBJECTIVE: This study aimed to assess whether elevating the head of the bed to 45° was associated with sensitivity >90% of the qualitative ultrasound assessment for the diagnosis of gastric fluid volume > 1.5 ml.kg-1. We also assessed the performance of qualitative assessment, composite ultrasound scale, and clinical algorithm, for the diagnosis of fluid volume > 1.5 ml.kg-1 according to whether the head of the bed was elevated to 45° or not. DESIGN: Prospective randomized observer-blind crossover trial. SETTING: Hospices Civils de Lyon, France. PATIENT: Healthy adult volunteers. INTERVENTIONS: Two separate study sessions in fasting volunteers: with and without head-of-bed elevation to 45°, in a randomized order. Each session consisted of three tests, each corresponding to a randomized and different volume of water (either 0, 50, 100, 150 or 200 ml); the same volumes were used in both sessions and in a randomized order. Gastric ultrasounds were performed three minutes after the ingestion of water by an investigator blinded to the volume ingested. MEASUREMENTS: Diagnostic performance of each approach for the diagnosis of gastric fluid volume > 1.5 ml.kg-1. MAIN RESULTS: Twenty volunteers were included, and 120 measurements were analyzed. The sensitivity of the qualitative assessment for the diagnosis of gastric fluid volume > 1.5 ml.kg-1 with and without head-of-bed elevation was 91% (95%CI: 75-98) and 75% (95%CI: 57-89), respectively. The clinical algorithm with head-of-bed elevation had significantly better sensitivity than the qualitative assessment with no head-of-bed elevation; there was no significant difference for other comparisons. CONCLUSIONS: The results suggest that qualitative examination of gastric antrum in the supine position with head-of-bed elevation to 45° can discriminate between low and high gastric fluid volume with high sensitivity, while neither the composite ultrasound scale nor the clinical algorithm improved the diagnostic performance of gastric ultrasound for the diagnosis of gastric fluid volume > 1.5 ml.kg-1.


Assuntos
Conteúdo Gastrointestinal , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Estudos Cross-Over , Conteúdo Gastrointestinal/diagnóstico por imagem , Humanos , Estudos Prospectivos , Ultrassonografia/métodos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...