Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am Heart J ; 120(6 Pt 1): 1342-7, 1990 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-2248181

RESUMO

Endocardial lead systems for implantable cardioverter-defibrillators utilize large (12F) rigid catheters with spring defibrillation electrodes, and lead system failure has been observed during long-term implant. We evaluated a novel flexible 8F braided electrode catheter for pacing and defibrillation in canine experiments. Active fixation and pacing were accomplished using a screw-in distal electrode, and defibrillation pulses were delivered through a braided electrode. Two braided electrode catheters were positioned in the right ventricular apex (6 cm2) and in the superior vena cava-right atrial junction (5 cm2), respectively. An elliptical 13 cm2 surface area patch electrode was positioned along the left lateral cardiac border. Ventricular fibrillation (VF) was induced and monophasic and asymmetric biphasic shocks (leading voltages 260 to 1000 V) were delivered via dual and triple electrode configurations in each animal using a prospective randomized crossover study design. Mean right ventricular pacing threshold was 0.5 +/- 0.2 mA, with a mean electrogram amplitude of 11.1 +/- 2.8 mV during sinus rhythm prior to fibrillation and defibrillation. Two hundred seven VF inductions (mean 30 +/- 4 per animal) were analyzed. The mean defibrillation threshold could be reduced to 8.0 +/- 3.2 joules with biphasic shocks from 12.9 +/- 5.1 joules obtained for monophasic shocks using a dual electrode system (p less than 0.004). Mean shock leading voltage was correspondingly reduced to 488 +/- 100 V from 691 +/- 154 V (p less than 0.0006).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cardioversão Elétrica/instrumentação , Próteses e Implantes , Animais , Estimulação Cardíaca Artificial , Cães , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Eletrodos , Desenho de Equipamento , Segurança de Equipamentos , Estudos de Avaliação como Assunto , Masculino , Miocárdio/patologia
2.
J Am Coll Cardiol ; 5(2 Pt 1): 259-67, 1985 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-3968310

RESUMO

Selective modification of atrioventricular (AV) nodal conduction, that is, induction of varying degrees of AV nodal delays or block (second or third degree), or both, was achieved with a pervenous laser catheter technique. In six adult mongrel dogs anesthetized with pentobarbital (Nembutal), 5F leads were placed through femoral and external jugular veins and placed into the right atrium and His bundle region. Through another femoral vein, a 200 micron optical fiber was inserted by way of a 7F catheter with a preformed curved tip. Guided by fluoroscopy and His bundle electrograms, the fiber's tip was positioned in the AV nodal region. After autonomic blockade was achieved with intravenous propranolol (5 mg) and atropine (1 mg), AV conduction was analyzed. An argon laser delivered 3 to 4 watts into the fiber in bursts of 10 seconds' duration until the desired degree of AV nodal delay or block (second or third degree) was manifested. Monitoring of His bundle electrograms was continued for 2 hours. Four weekly serial electrocardiograms were recorded, after which electrophysiologic studies were repeated. Acute post-lasing studies showed that: in all six dogs, the mean PR interval was prolonged from 116 ms (range 100 to 135) to 153 ms (range 120 to 185), with the prolongation being caused exclusively by AH lengthening from 68 ms (range 50 to 90) to 105 ms (range 65 to 140); the mean effective refractory period of the AV node increased from less than 185 ms (range less than 150 to less than 200) to 215 ms (range 190 to 280); and the mean atrial pacing cycle length, at which second degree AV nodal block was manifested, increased from 210 ms (range 160 to 260) to 261 ms (range 205 to 320).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Nó Atrioventricular/fisiopatologia , Bloqueio Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Lasers , Doença Aguda , Animais , Nó Atrioventricular/efeitos da radiação , Fascículo Atrioventricular/fisiopatologia , Cateterismo Cardíaco/métodos , Estimulação Cardíaca Artificial , Doença Crônica , Cães , Eletrocardiografia , Seguimentos , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/terapia , Terapia a Laser , Esforço Físico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...