Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Emerg Med Australas ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649791

RESUMO

The COVID-19 pandemic catapulted Telehealth to the forefront of Emergency Medicine (EM) as an alternative way of assessing and managing patients. This challenged the traditional idea that EM can only be practised within brick-and-mortar EDs. Many Emergency Physicians may find the idea of practising Telehealth in Emergency Medicine (TEM) confronting, particularly in the absence of training and clear practice guidelines. The purpose of the present paper is to describe the current use of TEM in Australasia, and outline the advantages and barriers in adopting this practice domain.

2.
Emerg Med Australas ; 35(2): 242-245, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36333871

RESUMO

SLICE is an algorithm for the integration of point-of-care ultrasound in the assessment and resuscitation of the shocked or breathless patient. It aims to determine the patient's fluid status, and identify reversible causes for the patient's clinical picture. SLICE stands for 'In a patient who is Shocked/Short of breath, scan the Lungs, IVC, Cardiac and Extra regions as indicated'. Its key advantages are that it explicitly guides resuscitative fluid management, can be performed rapidly and by clinicians with a broad range of sonographic experience, and can be used in a broad range of clinical scenarios. Its use has been successfully taught and implemented in routine clinical practice at our local institution.


Assuntos
Choque , Humanos , Ultrassonografia , Ressuscitação , Dispneia , Algoritmos , Sistemas Automatizados de Assistência Junto ao Leito
3.
Am J Emerg Med ; 56: 87-91, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35367684

RESUMO

INTRODUCTION: Optimal patient positioning during intubation improves laryngeal view and first pass success, as well as reducing incidence of hypoxia. In certain pre-hospital situations, it may be impractical or impossible for the operator to stand behind the patient. OBJECTIVE: We compared intubation in the supine and upright face-to-face positions, with regards to time to intubate and the view of the vocal cords obtained. METHODS: This was a pilot comparison study. One investigator intubated 25 cadavers with the use of a bougie in the supine and upright face-to-face positions. Each attempt was recorded on a video laryngoscope. Recordings of each attempt were reviewed by five blinded emergency physicians, who allocated both a percentage of glottic opening (POGO) score and Cormack-Lehane (CL) grade. Time to insertion of the endotracheal tube (ETT) through the vocal cords was measured from the video. RESULTS: The median intubation time was 1 s longer for upright cadavers than for supine cadavers, with greater variation in intubation times for upright cadavers compared with supine cadavers (IQR 9.0 vs 3.5 excluding the outlier case). The mean POGO score (averaged across raters) was 4.7% lower for upright intubation attempts (excluding the outlier case) with a moderate-to-good degree of inter-rater reliability, however this difference was not statistically significant. The median CL grade (averaged across raters) was 0.2 higher for upright intubation attempts (excluding the outlier case) with a poor-to-moderate degree of inter-rater reliability, and this difference was also not statistically significant. CONCLUSIONS: This pilot study suggests that upright, face-to-face intubation may be clinically similar to supine intubation in terms of time to intubation and difficulty. Further studies utilising a larger number of operators and cadaver types are indicated.


Assuntos
Laringoscópios , Laringoscopia , Cadáver , Humanos , Intubação Intratraqueal , Projetos Piloto , Reprodutibilidade dos Testes
5.
CJEM ; 19(6): 459-470, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27998322

RESUMO

Introduction The International Federation for Emergency Medicine (IFEM) Ultrasound Special Interest Group (USIG) was tasked with development of a hierarchical consensus approach to the use of point of care ultrasound (PoCUS) in patients with hypotension and cardiac arrest. METHODS: The IFEM USIG invited 24 recognized international leaders in PoCUS from emergency medicine and critical care to form an expert panel to develop the sonography in hypotension and cardiac arrest (SHoC) protocol. The panel was provided with reported disease incidence, along with a list of recommended PoCUS views from previously published protocols and guidelines. Using a modified Delphi methodology the panel was tasked with integrating the disease incidence, their clinical experience and their knowledge of the medical literature to evaluate what role each view should play in the proposed SHoC protocol. RESULTS: Consensus on the SHoC protocols for hypotension and cardiac arrest was reached after three rounds of the modified Delphi process. The final SHoC protocol and operator checklist received over 80% consensus approval. The IFEM-approved final protocol, recommend Core, Supplementary, and Additional PoCUS views. SHoC-hypotension core views consist of cardiac, lung, and inferior vena vaca (IVC) views, with supplementary cardiac views, and additional views when clinically indicated. Subxiphoid or parasternal cardiac views, minimizing pauses in chest compressions, are recommended as core views for SHoC-cardiac arrest; supplementary views are lung and IVC, with additional views when clinically indicated. Both protocols recommend use of the "4 F" approach: fluid, form, function, filling. CONCLUSION: An international consensus on sonography in hypotension and cardiac arrest is presented. Future prospective validation is required.


Assuntos
Reanimação Cardiopulmonar/normas , Consenso , Medicina de Emergência/normas , Parada Cardíaca/terapia , Hipotensão/etiologia , Sistemas Automatizados de Assistência Junto ao Leito/organização & administração , Ultrassonografia , Parada Cardíaca/complicações , Parada Cardíaca/diagnóstico , Humanos , Hipotensão/diagnóstico
6.
Emerg Med Australas ; 27(4): 295-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26072675

RESUMO

BACKGROUND: In critical care medicine, US views of the inferior vena cava (IVC) and its change with respiration are used to estimate the intravascular volume status of unwell patients and, in particular, to answer the question: 'Is this patient likely to be fluid responsive?' Most commonly in the literature, the subxiphisternal (SX) window in the longitudinal plane is utilised. To date, no study has specifically assessed interrater agreement in estimating IVC diameter between emergency medicine specialists (experts) and trainees (learners). OBJECTIVES: To determine the interrater agreement between an expert (senior emergency specialist with US qualifications) and learner (emergency medicine trainee) when measuring IVC diameter (IVCD) and IVC collapsibility index (IVCCI) in the SX longitudinal US window in healthy volunteers. METHODS: Healthy volunteers (ED staff) were scanned in the supine position using a sector (cardiac) probe of a portable US machine, in the SX longitudinal position. The maximum and minimum diameters of the IVC were measured in each of these positions and the IVCCI calculated. Results were analysed using Bland-Altman plots. RESULTS: In the longitudinal SX window, the operators' measurements of maximum IVCD differed by an average of 1.9 mm (95% limits of agreement -9.4 mm to +5.5 mm) and their measurement of IVCCI differed by an average of 4% (95% limits of agreement -30% to 38%). CONCLUSIONS: The wide 95% limits of agreement demonstrate a poor interrater agreement between the IVC US measurements obtained by expert and learner users in the assessment of fluid status. These ranges are greater than clinically acceptable.


Assuntos
Cuidados Críticos/métodos , Veia Cava Inferior/diagnóstico por imagem , Adulto , Pressão Venosa Central/fisiologia , Feminino , Humanos , Inalação/fisiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Ultrassonografia , Veia Cava Inferior/fisiologia
7.
CJEM ; 17(2): 161-70, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26052968

RESUMO

To meet a critical and growing need for a standardized approach to emergency point of care ultrasound (PoCUS) worldwide, emergency physicians must be trained to deliver and teach this skill in an accepted and reliable format. Currently, there is no globally recognized, standard PoCUS curriculum that defines the accepted applications, as well as standards for training and practice of PoCUS by specialists and trainees in emergency medicine. To address this deficit, the International Federation for Emergency Medicine (IFEM) convened a sub-committee of international experts in PoCUS to outline a curriculum for training of specialists in emergency PoCUS. This curriculum document represents the consensus of recommendations by this sub-committee. The curriculum is designed to provide a framework for PoCUS education in emergency medicine. The focus is on the processes required to select core and enhanced applications, as well as the key elements required for the delivery of PoCUS training from introduction through to continuing professional development and skill maintenance. It is designed not to be prescriptive but to assist educators and emergency medicine leadership to advance PoCUS education in emergency medicine no matter the training venue. The content of this curriculum is relevant not just for communities with mature emergency medicine systems but in particular for developing nations or for nations seeking to develop PoCUS training programs within the current educational structure. We anticipate that there will be wide variability in how this curriculum is implemented and taught, reflecting the existing educational environment, resources and goals of educational programs.


Assuntos
Competência Clínica , Currículo/normas , Educação Médica Continuada/métodos , Medicina de Emergência/educação , Cooperação Internacional , Médicos/normas , Sistemas Automatizados de Assistência Junto ao Leito , Humanos
8.
Australas J Ultrasound Med ; 18(1): 33-37, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28191239

RESUMO

Introduction: Obesity levels mean an increased presentation of patients with Laparoscopic adjustable gastric banding (LAGB). Method: Literature search revealed a paucity of information on ultrasonography to diagnose a slipped LAGB. Conclusion: 2D Ultrasonography with a standard low frequency curvilinear probe proved to be a simple, effective method of diagnosing slipped Laparoscopic adjustable gastric banding (LAGB). We suggest the inclusion of routine abdominal ultrasound (after drinking water to improve sensitivity of the test) as part of the routine workup of suspected LAGB slippage.

9.
J Am Soc Echocardiogr ; 27(7): 683.e1-683.e33, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24951446

RESUMO

BACKGROUND: Focused cardiac ultrasound (FoCUS) is a simplified, clinician-performed application of echocardiography that is rapidly expanding in use, especially in emergency and critical care medicine. Performed by appropriately trained clinicians, typically not cardiologists, FoCUS ascertains the essential information needed in critical scenarios for time-sensitive clinical decision making. A need exists for quality evidence-based review and clinical recommendations on its use. METHODS: The World Interactive Network Focused on Critical UltraSound conducted an international, multispecialty, evidence-based, methodologically rigorous consensus process on FoCUS. Thirty-three experts from 16 countries were involved. A systematic multiple-database, double-track literature search (January 1980 to September 2013) was performed. The Grading of Recommendation, Assessment, Development and Evaluation method was used to determine the quality of available evidence and subsequent development of the recommendations. Evidence-based panel judgment and consensus was collected and analyzed by means of the RAND appropriateness method. RESULTS: During four conferences (in New Delhi, Milan, Boston, and Barcelona), 108 statements were elaborated and discussed. Face-to-face debates were held in two rounds using the modified Delphi technique. Disagreement occurred for 10 statements. Weak or conditional recommendations were made for two statements and strong or very strong recommendations for 96. These recommendations delineate the nature, applications, technique, potential benefits, clinical integration, education, and certification principles for FoCUS, both for adults and pediatric patients. CONCLUSIONS: This document presents the results of the first International Conference on FoCUS. For the first time, evidence-based clinical recommendations comprehensively address this branch of point-of-care ultrasound, providing a framework for FoCUS to standardize its application in different clinical settings around the world.


Assuntos
Consenso , Ecocardiografia/normas , Medicina Baseada em Evidências/métodos , Sistemas Automatizados de Assistência Junto ao Leito/normas , Guias de Prática Clínica como Assunto , Conferências de Consenso como Assunto , Humanos
10.
Ultrasound ; 22(4): 223-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27433223

RESUMO

Right upper quadrant and epigastric abdominal pain are common presenting complaints in the emergency department. With increasing access to point-of-care ultrasound, emergency physicians now have an added tool to help identify biliary problems as a cause of a patient's right upper quadrant pain. Point-of-care ultrasound has a sensitivity of 89.8% (95% CI 86.4-92.5%) and specificity of 88.0% (83.7-91.4%) for cholelithiasis, very similar to radiology-performed ultrasonography. In addition to assessment for cholelithiasis and cholecystitis, point-of-care ultrasound can help emergency physicians to determine whether the biliary system is the source of infection in patients with suspected sepsis. Use of point-of-care ultrasound for the assessment of the biliary system has resulted in more rapid diagnosis, decreasing costs, and shorter emergency department length of stay.

11.
Injury ; 41(5): 484-7, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19800621

RESUMO

BACKGROUND: Patients presenting to Emergency Departments (EDs) with abdominal trauma benefit from FAST (Focused Assessment with Sonography in Trauma). Not all doctor members of the trauma team are credentialed in FAST; therefore occasionally no one is available in the hospital to undertake a FAST. Hence, the aim of this study was to determine the accuracy of nurse-performed FAST as a practical alternative where suitably trained doctors are not available. METHODS: This was a prospective study of a convenience sample of patients with multisystem trauma in whom abdominal injury was clinically suspected. Senior nurses trained in FAST performed and reported FAST scans for each patient. Accuracy of nurse-performed FAST was determined by comparing results with computerised tomography (CT) scan or operation report. RESULTS: 242 indicated nurse-performed FAST scans were included in the study. Nurse-performed FAST demonstrated sensitivity of 84.4% (95% CI 72.1-92.2) and specificity of 98.4% (CI 94.9-99.6), a positive predictive value (PPV) of 94.2% (CI 83.1-98.5) and a negative predictive value (NPV) of 95.3% (91.0-97.7). Overall accuracy of nurse-performed FAST for the detection of free fluid was 95.0% (95% CI 91.3-97.3). CONCLUSION: This study demonstrates that, in a convenience sample of injured patients, nurse-performed FAST achieved similar accuracy to previously published results of doctor-performed FAST. Future studies with greater patient numbers would be valuable.


Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Acreditação/métodos , Enfermagem em Emergência/normas , Serviço Hospitalar de Emergência , Traumatismo Múltiplo/diagnóstico por imagem , Líquido Ascítico/diagnóstico por imagem , Medicina de Emergência/educação , Feminino , Humanos , Masculino , Papel do Profissional de Enfermagem , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia , Recursos Humanos
12.
Emerg Med Australas ; 19(3): 188-95, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17564683

RESUMO

OBJECTIVE: Patients presenting to the ED with obstructive nephropathies benefit from early detection of hydronephrosis. Out of hours radiological imaging is expensive and disruptive to arrange. Emergency physician ultrasound (EPU) could allow rapid diagnosis and disposition. If accurate it might avert the need for formal radiological imaging, exclude an obstruction and improve patient flow through the ED. METHODS: This was a prospective study of a convenience sample of all adult non-pregnant patients with presumed ureteric colic attending the ED with prior ethics committee approval. An emergency physician or registrar performed a focused ultrasound scan and were blinded to the patient's other management. A computerized tomography scan was also performed for all patients while in the ED or within 24 h of the EPU. The accuracy of EPU detection of hydronephrosis was determined; using computerized tomography scans reported by a senior radiologist as the 'gold-standard'. RESULTS: Sixty-three patients with suspected ureteric colic were enrolled of whom 57 completed both EPU and computerized tomography imaging. Forty-nine had confirmed nephrolithiasis by computerized tomography with 39 having evidence of hydronephrosis. Overall prevalence of hydronephrosis was 68% (95% confidence interval [CI] 56-79%); compared with computerized tomography, EPU had a sensitivity of 80% (95% CI 65-89%); specificity of 83% (95% CI 61-94%); positive predictive value of 91% (95% CI 75-98%) and negative predictive value of 65% (95% CI 43-83%). The overall accuracy was 81% (95% CI 69-89%). CONCLUSION: Although the accuracy of detection of hydronephrosis after focused training in EPU is encouraging, further experience and training might improve the accuracy of EPU and allow its use as a screening tool.


Assuntos
Cólica/diagnóstico por imagem , Hidronefrose/diagnóstico por imagem , Doenças Ureterais/diagnóstico por imagem , Adulto , Competência Clínica , Intervalos de Confiança , Medicina de Emergência , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...