Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 90(2): 023503, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30831681

RESUMO

Rotation of the plasma and MHD modes in tokamaks has been shown to stabilize resistive wall and tearing modes as well as improve confinement through suppression of edge turbulence. In this work, we control mode rotation with a biased electrode inserted into the plasma of the High Beta Tokamak-Extended Pulse's facility in conjunction with its active GPU (Graphical Processing Unit) feedback system. We first characterize a negative linear relationship between the electrode voltage and mode rotation. Using this relationship, we design, simulate, and implement a proof-of-concept, GPU-based active-control system, which shows consistent success in controlling mode rotation in both feedforward and feedback operation. Controllability is limited by operating conditions, the electrode's voltage range, and by the electrode's proximity to the vessel's walls. The final control system has a 15 µs cycle time, but the addition of various signal filters results in a full cycle latency of 200 µs.

2.
Rev Sci Instrum ; 89(10): 10D110, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399818

RESUMO

Main-ion charge exchange recombination spectroscopy (MICER) uses the neutral beam induced D α spectrum to measure the local deuterium ion (D+) temperature, rotation, and density, as well as parameters related to the neutral beams, fast ions, and magnetic field. An edge MICER system consisting of 16 densely packed chords was recently installed on DIII-D, extending the MICER technique from the core to the pedestal and steep gradient region of H-mode plasmas where the D+ and commonly measured impurity ion properties can differ significantly. A combination of iterative collisional radiative modeling techniques and greatly accelerated spectral fitting allowed the extension of this diagnostic technique to the plasma edge where the steep gradients introduce significant diagnostic challenges. The importance of including the fast ion D α emission in the fit to the spectrum for the edge system is investigated showing that it is typically not important except for cases which can have significant fast ion fractions near the plasma edge such as QH-mode. Example profiles from an Ohmic L-mode and a high power ITER baseline case show large differences in the toroidal rotation of the two species near the separatrix including a strong co-current D+ edge rotation. The measurements and analysis demonstrate the state of the art in active spectroscopy and integrated modeling for diagnosing fusion plasmas and the importance of direct main ion measurements.

3.
Phys Plasmas ; 24(5): 056101, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28435207

RESUMO

A model-based feedback system is presented enabling the simultaneous control of the stored energy through ßn and the toroidal rotation profile of the plasma in National Spherical Torus eXperiment Upgrade device. Actuation is obtained using the momentum from six injected neutral beams and the neoclassical toroidal viscosity generated by applying three-dimensional magnetic fields. Based on a model of the momentum diffusion and torque balance, a feedback controller is designed and tested in closed-loop simulations using TRANSP, a time dependent transport analysis code, in predictive mode. Promising results for the ongoing experimental implementation of controllers are obtained.

4.
Surg Laparosc Endosc Percutan Tech ; 10(1): 44-6, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10872527

RESUMO

A case involving a patient with multiple stab wounds to the thoracoabdomen is reviewed. Laparoscopy was employed to determine peritoneal penetration. Hemodynamic collapse occurred secondary to tension pneumopericardium, which resulted from a 15 mm Hg pneumoperitoneum. The relevant literature is reviewed.


Assuntos
Traumatismos Abdominais/diagnóstico , Laparoscopia/efeitos adversos , Pneumopericárdio/etiologia , Traumatismos Torácicos/diagnóstico , Adulto , Humanos , Masculino , Esquizofrenia/complicações , Tentativa de Suicídio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...