Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37960484

RESUMO

The finite element method (FEM) was used to investigate the optical-mechanical behavior of a Fabry-Perot Interferometer (FPI) composed of a capillary segment spliced between two sections of standard optical fiber. The developed FEM model was validated by comparing it with theory and with previously published experimental data. The model was then used to show that the absolute strain on the host substrate is usually smaller than the strain measurement obtained with the sensor. Finally, the FEM model was used to propose a cavity geometry that can be produced with repeatability and that yields the correct absolute strain experienced by the host substrate, without requiring previous strain calibration.

2.
Sensors (Basel) ; 23(10)2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37430612

RESUMO

Ultrasonic communication and power transfer are attractive solutions when conventional electromagnetic-based or wired connections are unfeasible. Most ultrasonic communication applications concern a single-solid barrier. Nevertheless, some relevant scenarios can be composed of several fluid-solid media, through which communication and power transfer are intended. Due to its multi-layer nature, insertion loss and, consequently, the system efficiency considerably decrease. This paper presents an ultrasonic system capable of simultaneously power transferring and transmitting data through a set of two flat steel plates separated by a fluid layer using a pair of co-axially aligned piezoelectric transducers on opposite sides of the barrier. The system is based on frequency modulation and adopts a novel technique for automatic gain and automatic carrier control. The modems used herein were developed specifically for this application, rendering the system able to transfer data at a rate of 19,200 bps, using the frequency shift keying (FSK) modulation scheme and simultaneously transferring 66 mW of power through two flat steel plates (5 mm) separated by a fluid layer (100 mm), which completely supplied a pressure and temperature sensor. The proposed automatic gain control allowed a higher data transmission rate and the automatic carrier control reduced power consumption. The former reduced the transmission error from 12% to 5%, while the latter reduced the global power consumption from 2.6 W to 1.2 W. The proposed system is promising for monitoring applications such as oil wellbore structural health monitoring systems.

3.
Sensors (Basel) ; 19(19)2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31547167

RESUMO

Ultrasonic power and data transfer through multilayered curved walls was investigated using numerical and experimental analysis. The acoustic channel used in this paper was formed by two concentric pipes filled with water, aiming for applications that involve powering and monitoring sensors installed behind the pipe walls. The analysis was carried out in the frequency and time domains using numerical and experimental models. Power and data were effectively simultaneously transferred through the channel. A remote temperature and pressure sensor was powered and interrogated throughout all the layers, and the power insertion loss was 10.72 dB with a data transmission rate of 1200 bps using an amplitude modulated scheme with Manchester coding. The efficiency of the channel was evaluated through an experimental analysis of the bit error rate (BER) with different values of signal-to-noise ratio (SNR), showing a decrease in the number of errors compared with detection without Manchester coding.

4.
Sensors (Basel) ; 17(7)2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-28714892

RESUMO

A passive surface acoustic wave (SAW) pressure sensor was developed for real-time pressure monitoring in downhole application. The passive pressure sensor consists of a SAW resonator, which is attached to a circular metal diaphragm used as a pressure transducer. While the membrane deflects as a function of pressure applied, the frequency response changes due to the variation of the SAW propagation parameters. The sensitivity and linearity of the SAW pressure sensor were measured to be 8.3 kHz/bar and 0.999, respectively. The experimental results were validated with a hybrid analytical-numerical analysis. The good results combined with the robust design and packaging for harsh environment demonstrated it to be a promising sensor for industrial applications.

5.
Opt Express ; 24(13): 14690-6, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410621

RESUMO

In this paper we discuss the results obtained with an in-fiber Fabry-Perot interferometer (FPI) used in strain and magnetic field (or force) sensing. The intrinsic FPI was constructed by splicing a small section of a capillary optical fiber between two pieces of standard telecommunication fiber. The sensor was built by attaching the FPI to a magnetostrictive alloy in one configuration and also by attaching the FPI to a small magnet in another. Our sensors were found to be over 4 times more sensitive to magnetic fields and around 10 times less sensitive to temperature when compared to sensors constructed with Fiber Bragg Grating (FBG).

6.
Opt Express ; 21(22): 27023-31, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24216926

RESUMO

Dengue fever is a viral disease that affects millions of people worldwide. Specific tests for dengue are not usually performed due to high costs, complicated procedures and, in some cases, long time to yield a result. For widespread use of specific tests to be possible, fast, reliable and fairly simple methods are needed. In this paper, we present a new dengue diagnostic method for the acute phase of the infection. The method proposed uses an all-optical fiber sensor based on Localized Surface Plasmon Resonance (LSPR) and specular reflection from gold nanoparticles (AuNPs). Dengue anti-NS1 antibody was immobilized on AuNPs deposited on the endface of a standard multimode fiber (62.5 µm/125 µm). The sensor is able to detect NS1 antigen at different concentrations, with limit of quantification estimated to be 0.074 µg/ml = 1.54 nM. These results indicate that the sensor could potentially be used for dengue diagnosis in the acute phase of the infection.


Assuntos
Técnicas Biossensoriais/instrumentação , Vírus da Dengue/isolamento & purificação , Tecnologia de Fibra Óptica/instrumentação , Imunoensaio/instrumentação , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Vírus da Dengue/imunologia , Desenho de Equipamento , Análise de Falha de Equipamento , Proteínas não Estruturais Virais/análise , Proteínas não Estruturais Virais/imunologia
7.
Opt Express ; 20(5): 5429-39, 2012 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-22418350

RESUMO

Materials presenting high optical nonlinearity, such as materials containing metal nanoparticles (NPs), can be used in various applications in photonics. This motivated the research presented in this paper, where morphological, linear and nonlinear optical characteristics of gold NPs on the surface of bulk soda-lime glass substrates were investigated as a function of nanoparticle height. The NPs were obtained by annealing gold (Au) thin films previously deposited on the substrates. Pixel intensity histogram fitting on Atomic Force Microscopy (AFM) images was performed to obtain the thickness of the deposited film. Image analysis was employed to obtain the statistical distribution of the average height of the NPs. In addition, absorbance spectra of the samples before and after annealing were measured. Finally, the nonlinear refractive index (n2) and the nonlinear absorption index (α2) at 800 nm were obtained before and after annealing by using the thermally managed eclipse Z-scan (TM-EZ) technique with a Ti:Sapphire laser (150 fs pulses). Results show that both n2 and α2 at this wavelength change signs after the annealing and that the samples presented a high nonlinear refractive index.


Assuntos
Compostos de Cálcio/química , Ouro/química , Nanopartículas/química , Nanopartículas/ultraestrutura , Óxidos/química , Refratometria/métodos , Hidróxido de Sódio/química , Adsorção , Vidro/química , Luz , Modelos Lineares , Teste de Materiais , Dinâmica não Linear , Espalhamento de Radiação , Propriedades de Superfície
8.
Sensors (Basel) ; 11(12): 11103-11, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22247655

RESUMO

A magnetic field sensor based on the integration of a high birefringence photonic crystal fiber and a composite material made of Terfenol particles and an epoxy resin is proposed. An in-fiber modal interferometer is assembled by evenly exciting both eigenemodes of the HiBi fiber. Changes in the cavity length as well as the effective refractive index are induced by exposing the sensor head to magnetic fields. The magnetic field sensor has a sensitivity of 0.006 (nm/mT) over a range from 0 to 300 mT with a resolution about ±1 mT. A fiber Bragg grating magnetic field sensor is also fabricated and employed to characterize the response of Terfenol composite to the magnetic field.


Assuntos
Ligas/química , Magnetismo , Fótons , Cristalização
9.
Opt Express ; 18(25): 25657-64, 2010 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-21164912

RESUMO

We present the design of an air hole microstructured photonic crystal fiber for pressure sensing applications. The air-hole photonic crystal lattices were designed to produce a large intrinsic birefringence of 1.16 x 10(-3). The impact of the surrounding air holes for pressure sensing to the propagation mode profiles and indices were studied and improved, which ensures single mode propagation in the fiber core defined by the photonic crystal lattice. An air hole matrix and a practical chemical etching process during the fiber perform preparation stage is proposed to produce an optical fiber with a birefringence-pressure coefficient of 43.89 x 10 (-6)MPa(-1) or a fiber Bragg grating pressure responsivity of 44.15 pm/MPa, which is a 17 times improvement over previous photonic crystal fiber designs.


Assuntos
Tecnologia de Fibra Óptica , Manometria/instrumentação , Refratometria/instrumentação , Birrefringência , Simulação por Computador , Desenho Assistido por Computador , Cristalização , Desenho de Equipamento , Análise de Falha de Equipamento , Modelos Teóricos , Pressão
10.
Sensors (Basel) ; 10(11): 9698-711, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22163435

RESUMO

The effect of hydrostatic pressure on the waveguiding properties of high birefringence photonic crystal fibers (HiBi PCF) is evaluated both numerically and experimentally. A fiber design presenting form birefringence induced by two enlarged holes in the innermost ring defining the fiber core is investigated. Numerical results show that modal sensitivity to the applied pressure depends on the diameters of the holes, and can be tailored by independently varying the sizes of the large or small holes. Numerical and experimental results are compared showing excellent agreement. A hydrostatic pressure sensor is proposed and demonstrated using an in-fiber modal interferometer where the two orthogonally polarized modes of a HiBi PCF generate fringes over the optical spectrum of a broad band source. From the analysis of experimental results, it is concluded that, in principle, an operating limit of 92 MPa in pressure could be achieved with 0.0003% of full scale resolution.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Tecnologia de Fibra Óptica/métodos , Fibras Ópticas , Fótons , Cristalização , Modelos Teóricos , Pressão
11.
Sensors (Basel) ; 10(9): 8119-28, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22163644

RESUMO

This paper presents a light and compact optical fiber Bragg Grating sensor for DC and AC magnetic field measurements. The fiber is coated by a thick layer of a magnetostrictive composite consisting of particles of Terfenol-D dispersed in a polymeric matrix. Among the different compositions for the coating that were tested, the best magnetostrictive response was obtained using an epoxy resin as binder and a 30% volume fraction of Terfenol-D particles with sizes ranging from 212 to 300 µm. The effect of a compressive preload in the sensor was also investigated. The achieved resolution was 0.4 mT without a preload or 0.3 mT with a compressive pre-stress of 8.6 MPa. The sensor was tested at magnetic fields of up to 750 mT under static conditions. Dynamic measurements were conducted with a magnetic unbalanced four-pole rotor.


Assuntos
Resinas Epóxi/química , Tecnologia de Fibra Óptica/instrumentação , Imãs/química , Fibras Ópticas , Campos Magnéticos , Tamanho da Partícula , Poliuretanos/química , Eletricidade Estática
12.
J Acoust Soc Am ; 122(4): 1906-16, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17902827

RESUMO

This paper formulates and solves a time harmonic inverse scattering problem to reconstruct the effective stiffness distribution of an adhesive bond in a layered elastic plate. The motivation is based on the assumption that localized adhesion flaws that diminish bond stiffness also tend to diminish bond strength. The formulation is based on the invariant imbedding method, applies to isotropic and anisotropic elastic layers, and is essentially that of identifying embedded acoustic sources in elastic layered structures. This paper presents two solutions for the inverse problem: the Born approximation and the exact solution. The example calculations compare the two solutions and show that when imperfections are too large in either magnitude or extent the accuracy of the Born approximation breaks down. The impact of noise and uncertainties in the background properties in the inversion is also investigated. A regularization strategy is introduced in the exact solution that controls solution sensitivity in regions with low signal to noise ratio.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA