Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Appl Oral Sci ; 24(4): 310-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27556200

RESUMO

OBJECTIVE: The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. MATERIAL AND METHODS: Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. RESULTS: WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. CONCLUSION: After clinical use, no statistically significant reduction in the torsional resistance was observed.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Torção Mecânica , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Microscopia Eletrônica de Varredura , Níquel , Valores de Referência , Rotação , Estresse Mecânico , Propriedades de Superfície , Titânio , Torque
2.
J. appl. oral sci ; 24(4): 310-316, July-Aug. 2016. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-792591

RESUMO

ABSTRACT Torsional overload is a fracture representative parameter for instruments in single-file techniques. Objective The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. Material and Methods Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. Results WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. Conclusion After clinical use, no statistically significant reduction in the torsional resistance was observed.


Assuntos
Preparo de Canal Radicular/instrumentação , Instrumentos Odontológicos , Torção Mecânica , Valores de Referência , Rotação , Estresse Mecânico , Propriedades de Superfície , Titânio , Teste de Materiais , Microscopia Eletrônica de Varredura , Torque , Desenho de Equipamento , Falha de Equipamento , Níquel
3.
J Endod ; 40(9): 1494-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25146041

RESUMO

INTRODUCTION: The aim of this study was to assess the influence of M-Wire (Dentsply Tulsa Dental Specialties, Tulsa, OK) and controlled memory technologies on the fatigue resistance of rotary nickel-titanium (NiTi) files by comparing files made using these 2 technologies with conventional NiTi files. METHODS: Files with a similar cross-sectional design and diameter were chosen for the study: new 30/.06 files of the EndoWave (EW; J. Morita Corp, Osaka, Japan), HyFlex (HF; Coltene/Whaledent, Inc, Cuyahoga Falls, OH), ProFile Vortex (PV; Dentsply Tulsa Dental Specialties, Tulsa, OK), and Typhoon (TYP; Clinician's Choice Dental Products, New Milford, CT) systems together with ProTaper Universal F2 instruments (PTU F2; Dentsply Maillefer, Ballaigues, Switzerland). The compositions and transformation temperatures of the instruments were analyzed using x-ray energy-dispersive spectroscopy and differential scanning calorimetry, whereas the mean file diameter values at 3 mm from the tip (D3) were measured using image analysis software. The average number of cycles to failure was determined using a fatigue test device. RESULTS: X-ray energy-dispersive spectroscopy analysis showed that, on average, all the instruments exhibited the same chemical composition, namely, 51% Ni-49% Ti. The PV, TYP, and HF files exhibited increased transformation temperatures. The PTU F2, PV, and TYP files had similar D3 values, which were less than those of the EW and HF files. The average number of cycles to failure values were 150% higher for the TYP files compared with the PV files and 390% higher for the HF files compared with the EW files. CONCLUSIONS: M-Wire and controlled memory technologies increase the fatigue resistance of rotary NiTi files.


Assuntos
Ligas Dentárias/química , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Varredura Diferencial de Calorimetria , Ligas Dentárias/análise , Desenho de Equipamento , Falha de Equipamento , Temperatura Alta , Humanos , Processamento de Imagem Assistida por Computador/métodos , Teste de Materiais , Metalurgia , Microscopia Eletrônica de Varredura , Níquel/análise , Óxidos/análise , Fotografação/métodos , Rotação , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Titânio/análise , Temperatura de Transição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA