Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pediatr Surg ; 47(1): 154-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22244409

RESUMO

PURPOSE: The magnetic mini-mover procedure (3MP) uses magnetic force to gradually remodel pectus excavatum deformity. A magnet is implanted on the sternum and coupled with an external magnetic brace. Under Investigational Device Exemption and Institutional Review Board approval, we performed a pilot study of safety, probable efficacy, and cost-effectiveness of this new treatment of an orphan disease using an implantable pediatric device. METHODS: Ten otherwise healthy patients, ages 8 to 14 years, with severe pectus excavatum (pectus severity index [PSI] > 3.5) underwent 3MP treatment (mean, 18.8 ± 2.5 months). Safety was assessed by postimplant and postexplant electrocardiograms and monthly chest x-rays. Efficacy was assessed by change in pectus severity index as measured using pretreatment and posttreatment computed tomographic scan. Cost of 3MP was compared with that of standard procedures. RESULTS: The 3MP device had no detectable ill effect. Device weld failure or malpositioning required revision in 5 patients. Average wear time was 16 h/d. Pectus severity index improved in patients in the early or mid puberty but not in patients with noncompliant chest walls. Average cost for 3MP was $46,859, compared with $81,206 and $81,022 for Nuss and Ravitch, respectively. CONCLUSION: The 3MP is a safe, cost-effective, outpatient alternative treatment for pectus excavatum that achieves good results for patients in early and midpuberty stages.


Assuntos
Tórax em Funil/cirurgia , Imãs , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Próteses e Implantes , Adolescente , Criança , Feminino , Tórax em Funil/classificação , Humanos , Imãs/efeitos adversos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Projetos Piloto , Estados Unidos , United States Food and Drug Administration
2.
J Pediatr Surg ; 45(9): 1753-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20850616

RESUMO

BACKGROUND/PURPOSE: The prognosis for multiple vs singleton pregnancies affected by congenital diaphragmatic hernia (CDH) is not known. To improve the counseling of families with multiple gestation pregnancies complicated by CDH, we examined outcomes of a consecutive series of CDH cases occurring in multiple gestation pregnancy referrals. METHODS: Clinical characteristics and morbidity and mortality data were gathered for a consecutive series of infants with CDH from 16 multiple gestation pregnancies. Outcomes were compared to a cohort of 91 patients with CDH from singleton pregnancies. Multivariate regression was also used in an attempt to determine whether multiple gestation pregnancy was independently predictive of subsequent long-term adverse outcomes. RESULTS: Four pregnancies were lost to follow-up, and 1 underwent selective reduction. Overall mortality for live-born multiple gestation fetuses affected by CDH was 30% and was 8% for unaffected siblings. No pregnancy was concordant. Clinical features were not different between the case series and control infants, except median gestational age at delivery, which was significantly lower for the multigestational infants (34 [range, 32-36] vs 38 [range, 28-41] weeks) (P = .02). Long-term morbidity was comparable between cases and controls. CONCLUSIONS: In terms of mortality, outcomes of multigestational pregnancies affected by CDH are no worse than for CDH pregnancies in general. Long-term risk may depend more on CDH severity rather than the presence of multiple fetuses.


Assuntos
Hérnia Diafragmática/epidemiologia , Hérnias Diafragmáticas Congênitas , Gravidez Múltipla , Criança , Feminino , Humanos , Recém-Nascido , Gravidez , Resultado da Gravidez , Prognóstico
3.
J Pediatr Surg ; 45(1): 185-91; discussion 191-2, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20105602

RESUMO

PURPOSE: The Magnetic Mini-Mover Procedure (3MP) uses a magnetic implant coupled with an external magnet to generate force sufficient to gradually remodel pectus excavatum deformities. This is an interim report of the evolution of the 3MP during a Food and Drug Administration-approved clinical trial. METHODS: After obtaining Institutional Review Board approval, we performed the 3MP on 10 otherwise healthy patients with moderate to severe pectus excavatum deformities (age, 8-14 years; Haller index >3.5). Operative techniques evolved to improve ease of implantation. Patients were evaluated monthly by a pediatric surgeon and orthotist. Electrocardiograms were performed pre- and postoperatively. Sternal position was documented by pre- and postprocedure computed tomographic scan, interval chest x-ray, depth gauge, and interval photographs. RESULTS: There was no detectable effect of the static magnetic field on wound healing or cardiopulmonary function. No detectable injuries and minimal skin changes resulted from brace wear. Operative techniques evolved to include a custom sternal punch and a flexible guide wire to guide the posterior plate into position behind the sternum, reducing outpatient operating time to one-half hour. In 9 patients, the procedure was performed as an outpatient basis; and 1 patient was observed overnight. Three patients required evacuation of retained pleural air postoperatively, and 2 required an outpatient revision. A custom-fitted orthotic brace (Magnatract) was extensively modified to increase user friendliness and functionality while incorporating several novel functions: a screw displacement mechanism so patients can easily self-adjust magnetic force, a miniature data logger to measure force and temperature data every 10 minutes, and an interactive online Web portal for remote patient evaluation. All attempts to quantitate sternal position (radiographic, fluid volume, and depth gauge) were inadequate. Visual assessment remains the best indicator. CONCLUSIONS: In this interim report, the 3MP appears to be a safe, minimally invasive, outpatient, cost-effective alternative treatment of pectus excavatum. Outcomes will be reported upon the completion of this phase II clinical trial.


Assuntos
Braquetes , Tórax em Funil/cirurgia , Magnetismo/instrumentação , Implantação de Prótese/métodos , Esterno/anormalidades , Parede Torácica/anormalidades , Adolescente , Procedimentos Cirúrgicos Ambulatórios/métodos , Criança , Desenho de Equipamento , Humanos , Internet , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Ortopédicos/métodos , Consulta Remota , Reoperação , Esterno/cirurgia , Parede Torácica/cirurgia , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA