Eur J Radiol ; 171: 111267, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38169217

RESUMO

PURPOSE: Computed tomography (CT) scans are a significant source of medically induced radiation exposure. Novel deep learning-based denoising (DLD) algorithms have been shown to enable diagnostic image quality at lower radiation doses than iterative reconstruction (IR) methods. However, most comparative studies employ low-dose simulations due to ethical constraints. We used real intraindividual animal scans to investigate the dose-reduction capabilities of a DLD algorithm in comparison to IR. MATERIALS AND METHODS: Fourteen veterinarian-sedated alive pigs underwent 2 CT scans on the same 3rd generation dual-source scanner with two months between each scan. Four additional scans ensued each time, with mAs reduced to 50 %, 25 %, 10 %, and 5 %. All scans were reconstructed ADMIRE levels 2 (IR2) and a novel DLD algorithm, resulting in 280 datasets. Objective image quality (CT numbers stability, noise, and contrast-to-noise ratio) was measured via consistent regions of interest. Three radiologists independently rated all possible dataset combinations per time point for subjective image quality (-1 = inferior, 0 = equal, 1 = superior). The points were averaged for a semiquantitative score, and inter-rater agreement was measured using Spearman's correlation coefficient and adequately corrected mixed-effects modeling analyzed objective and subjective image quality. RESULTS: Neither dose-reduction nor reconstruction method negatively impacted CT number stability (p > 0.999). In objective image quality assessment, the lowest radiation dose achievable by DLD when comparing noise (p = 0.544) and CNR (p = 0.115) to 100 % IR2 was 25 %. Overall, inter-rater agreement of the subjective image quality ratings was strong (r ≥ 0.69, mean 0.93 ± 0.05, 95 % CI 0.92-0.94; each p < 0.001), and subjective assessments corroborated that DLD at 25 % radiation dose was comparable to 100 % IR2 in image quality, sharpness, and contrast (p ≥ 0.281). CONCLUSIONS: The DLD algorithm can achieve image quality comparable to the standard IR method but with a significant dose reduction of up to 75%. This suggests a promising avenue for lowering patient radiation exposure without sacrificing diagnostic quality.


Assuntos
Aprendizado Profundo , Humanos , Animais , Suínos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Modelos Animais
2.
Acad Radiol ; 31(3): 921-928, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37500416

RESUMO

RATIONALE AND OBJECTIVES: To determine the impact on acquisition time reduction and image quality of a deep learning (DL) reconstruction for accelerated diffusion-weighted imaging (DWI) of the pelvis at 1.5 T compared to standard DWI. MATERIALS AND METHODS: A total of 55 patients (mean age, 61 ± 13 years; range, 27-89; 20 men, 35 women) were consecutively included in this retrospective, monocentric study between February and November 2022. Inclusion criteria were (1) standard DWI (DWIS) in clinically indicated magnetic resonance imaging (MRI) at 1.5 T and (2) DL-reconstructed DWI (DWIDL). All patients were examined using the institution's standard MRI protocol according to their diagnosis including DWI with two different b-values (0 and 800 s/mm2) and calculation of apparent diffusion coefficient (ADC) maps. Image quality was qualitatively assessed by four radiologists using a visual 5-point Likert scale (5 = best) for the following criteria: overall image quality, noise level, extent of artifacts, sharpness, and diagnostic confidence. The qualitative scores for DWIS and DWIDL were compared with the Wilcoxon signed-rank test. RESULTS: The overall image quality was evaluated to be significantly superior in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .05). The extent of noise was evaluated to be significantly less in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .001). No significant differences were found regarding artifacts, lesion detectability, sharpness of organs, and diagnostic confidence (P > .05). Acquisition time for DWIS was 2:06 minutes, and simulated acquisition time for DWIDL was 1:12 minutes. CONCLUSION: DL image reconstruction improves image quality, and simulation results suggest that a reduction in acquisition time for diffusion-weighted MRI of the pelvis at 1.5 T is possible.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Razão Sinal-Ruído , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Pelve/diagnóstico por imagem , Artefatos , Imageamento por Ressonância Magnética
3.
Acad Radiol ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37989681

RESUMO

OBJECTIVES: In interventional bronchial artery embolization (BAE), periprocedural cone beam CT (CBCT) improves guiding and localization. However, a trade-off exists between 6-second runs (high radiation dose and motion artifacts, but low noise) and 3-second runs (vice versa). This study aimed to determine the efficacy of an advanced deep learning denoising (DLD) technique in mitigating the trade-offs related to radiation dose and image quality during interventional BAE CBCT. MATERIALS AND METHODS: This study included BMI-matched patients undergoing 6-second and 3-second BAE CBCT scans. The dose-area product values (DAP) were obtained. All datasets were reconstructed using standard weighted filtered back projection (OR) and a novel DLD software. Objective image metrics were derived from place-consistent regions of interest, including CT numbers of the Aorta and lung, noise, and contrast-to-noise ratio. Three blinded radiologists performed subjective assessments regarding image quality, sharpness, contrast, and motion artifacts on all dataset combinations in a forced-choice setup (-1 = inferior, 0 = equal; 1 = superior). The points were averaged per item for a total score. Statistical analysis ensued using a properly corrected mixed-effects model with post hoc pairwise comparisons. RESULTS: Sixty patients were assessed in 30 matched pairs (age 64 ± 15 years; 10 female). The mean DAP for the 6 s and 3 s runs was 2199 ± 185 µGym² and 1227 ± 90 µGym², respectively. Neither low-dose imaging nor the reconstruction method introduced a significant HU shift (p ≥ 0.127). The 3 s-DLD presented the least noise and superior contrast-to-noise ratio (CNR) (p < 0.001). While subjective evaluation revealed no noticeable distinction between 6 s-DLD and 3 s-DLD in terms of quality (p ≥ 0.996), both outperformed the OR variants (p < 0.001). The 3 s datasets exhibited fewer motion artifacts than the 6 s datasets (p < 0.001). CONCLUSIONS: DLD effectively mitigates the trade-off between radiation dose, image noise, and motion artifact burden in regular reconstructed BAE CBCT by enabling diagnostic scans with low radiation exposure and inherently low motion artifact burden at short examination times.

4.
Diagnostics (Basel) ; 13(20)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37892061

RESUMO

PET/CT scanners with a long axial field-of-view (LAFOV) provide increased sensitivity, enabling the adjustment of imaging parameters by reducing the injected activity or shortening the acquisition time. This study aimed to evaluate the limitations of reduced [18F]FDG activity doses on image quality, lesion detectability, and the quantification of lesion uptake in the Biograph Vision Quadra, as well as to assess the benefits of the recently introduced ultra-high sensitivity mode in a clinical setting. A number of 26 patients who underwent [18F]FDG-PET/CT (3.0 MBq/kg, 5 min scan time) were included in this analysis. The PET raw data was rebinned for shorter frame durations to simulate 5 min scans with lower activities in the high sensitivity (HS) and ultra-high sensitivity (UHS) modes. Image quality, noise, and lesion detectability (n = 82) were assessed using a 5-point Likert scale. The coefficient of variation (CoV), signal-to-noise ratio (SNR), tumor-to-background ratio (TBR), and standardized uptake values (SUV) including SUVmean, SUVmax, and SUVpeak were evaluated. Subjective image ratings were generally superior in UHS compared to the HS mode. At 0.5 MBq/kg, lesion detectability decreased to 95% (HS) and to 98% (UHS). SNR was comparable at 1.0 MBq/kg in HS (5.7 ± 0.6) and 0.5 MBq/kg in UHS (5.5 ± 0.5). With lower doses, there were negligible reductions in SUVmean and SUVpeak, whereas SUVmax increased steadily. Reducing the [18F]FDG activity to 1.0 MBq/kg (HS/UHS) in a LAFOV PET/CT provides diagnostic image quality without statistically significant changes in the uptake parameters. The UHS mode improves image quality, noise, and lesion detectability compared to the HS mode.

5.
Aesthetic Plast Surg ; 47(6): 2242-2252, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37253846

RESUMO

BACKGROUND: Macromastia, micromastia and breast asymmetry have an impact on health and quality of life. However, there is scarce information addressing breast size and asymmetry frequency distribution in reference populations. OBJECTIVE: The current study aims to identify factors that influence breast size and symmetry and classifies abnormal breast sizes and breast asymmetries in an adult German population. METHODS: Breast base dimensions, breast volume, symmetry, and other breast anthropometric parameters of 400 German female patients were determined in a retrospective review of the MRI archives at our institution. Professional medical MRI-segmentation software was used for volume measurement. RESULTS: A total of 400 Patients were retrospectively enrolled. The patients had a mean age of 50 ± 12 years (min: 24; max: 82), mean BMI of 25.0 ± 5.0 (min: 14.7, max: 45.6), and a mean total breast volume of 976 ml (right: 973 ml, min: 64, max: 4777; left: 979 ml, min: 55, max: 4670). The strongest correlation of breast volume was observed with BMI (r = 0.834, p < 0.001), followed by breast base width (r = 0.799, p < 0.001). Smaller breasts have higher breast volume asymmetry ratios (r = - 0.124, p < 0.014). For a BMI between 18.5 and 24.9 kg/m2, micromastia is defined by breast volumes below 250 ml (5th percentile) and macromastia by volumes above 1250 ml (95th percentile). Abnormal breast volume asymmetry (< 5th and > 95th percentile) is equivalent to an absolute difference of approximately 25% relative to the smallest side (bidirectional asymmetry ratio 5th percentile - 19%; 95th percentile 26%). CONCLUSION: This study provides normative data of German women, as well as selected size-for-BMI percentiles and asymmetry ratio percentiles. The normative data may help to establish transparent and objective coverage criteria for health insurances. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Mama/anormalidades , Hipertrofia , Mamoplastia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Estudos de Coortes , Estudos Retrospectivos , Mamoplastia/métodos , Qualidade de Vida , Resultado do Tratamento , Estética
6.
Diagnostics (Basel) ; 13(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36832249

RESUMO

Due to its high morbidity and mortality, myocardial infarction is the leading cause of death worldwide. Against this background, rapid diagnosis is of immense importance. Especially in case of an atypical course, the correct diagnosis may be delayed and thus lead to increased mortality rates. In this report, we present a complex case of acute coronary syndrome. A triple-rule-out CT examination was performed in dual-energy CT (DECT) mode. While pulmonary artery embolism and aortic dissection could be ruled out with conventional CT series, the presence of anterior wall infarction was only detectable on DECT reconstructions. Subsequently, adequate and rapid therapy was then initiated leading to survival of the patient.

7.
Acad Radiol ; 30(8): 1678-1694, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36669998

RESUMO

OBJECTIVES: CT low-dose simulation methods have gained significant traction in protocol development, as they lack the risk of increased patient exposure. However, in-vivo validations of low-dose simulations are as uncommon as prospective low-dose image acquisition itself. Therefore, we investigated the extent to which simulated low-dose CT datasets resemble their real-dose counterparts. MATERIALS AND METHODS: Fourteen veterinarian-sedated alive pigs underwent three CT scans on the same third generation dual-source scanner with 2 months between each scan. At each time, three additional scans ensued, with mAs reduced to 50%, 25%, and 10%. All scans were reconstructed using wFBP and ADMIRE levels 1-5. Matching low-dose datasets were generated from the 100% scans using reconstruction-based and DICOM-based simulations. Objective image quality (CT numbers stability, noise, and signal-to-noise ratio) was measured via consistent regions of interest. Three radiologists independently rated all possible dataset combinations per time point for subjective image quality (-1=inferior, 0=equal, 1=superior). The points were averaged for a semiquantitative score, and inter-rater-agreement was measured using Spearman's correlation coefficient. A structural similarity index (SSIM) analyzed the voxel-wise similarity of the volumes. Adequately corrected mixed-effects analysis compared objective and subjective image quality. Multiple linear regression with three-way interactions measured the contribution of dose, reconstruction mode, simulation method, and rater to subjective image quality. RESULTS: There were no significant differences between objective and subjective image quality of reconstruction-based and DICOM-based simulation on all dose levels (p≥0.137). However, both simulation methods produced significantly lower objective image quality than real-dose images below 25% mAs due to noise overestimation (p<0.001; SSIM≤89±3). Overall, inter-rater-agreement was strong (r≥0.68, mean 0.93±0.05, 95% CI 0.92-0.94; each p<0.001). In regression analysis, significant decreases in subjective image quality were observed for lower radiation doses (b ≤ -0.387, 95%CI -0.399 to -0.358; p<0.001) but not for reconstruction modes, simulation methods, raters, or three-way interactions (p≥0.103). CONCLUSION: Simulated low-dose CT datasets are subjectively and objectively indistinguishable from their real-dose counterparts down to 25% mAs, making them an invaluable tool for efficient low-dose protocol development.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Animais , Suínos , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos
8.
Eur Radiol ; 33(4): 2945-2953, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36474057

RESUMO

OBJECTIVE: To evaluate the impact of the digital mammography imaging system on overall background enhancement on recombined contrast-enhanced spectral mammography (CESM) images, the overall background enhancement of two different mammography systems was compared. METHODS: In a retrospective single-center study, CESM images of n = 129 female patients who underwent CESM between 2016 and 2019 were analyzed independently by two radiologists. Two mammography machines of different manufacturers were compared qualitatively using a Likert-scale from 1 (minimal) to 4 (marked overall background enhancement) and quantitatively by placing a region of interest and measuring the intensity enhancement. Lesion conspicuity was analyzed using a Likert-scale from 1 (lesion not reliably distinguishable) to 5 (excellent lesion conspicuity). A multivariate regression was performed to test for potential biases on the quantitative results. RESULTS: Significant differences in qualitative background enhancement measurements between machines A and B were observed for both readers (p = 0.003 and p < 0.001). The quantitative evaluation showed significant differences in background enhancement with an average difference of 75.69 (99%-CI [74.37, 77.02]; p < 0.001). Lesion conspicuity was better for machine A for the first and second reader respectively (p = 0.009 and p < 0.001). The factor machine was the only influencing factor (p < 0.001). The factors contrast agent, breast density, age, and menstrual cycle could be excluded as potential biases. CONCLUSION: Mammography machines seem to significantly influence overall background enhancement qualitatively and quantitatively; thus, an impact on diagnostic accuracy appears possible. KEY POINTS: • Overall background enhancement on CESM differs between different vendors qualitatively and quantitatively. • Our retrospective single-center study showed consistent results of the qualitative and quantitative data analysis of overall background enhancement. • Lesion conspicuity is higher in cases of lower background enhancement on CESM.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Estudos Retrospectivos , Mamografia/métodos , Meios de Contraste/farmacologia , Densidade da Mama , Projetos de Pesquisa , Neoplasias da Mama/diagnóstico por imagem , Sensibilidade e Especificidade
9.
Diagnostics (Basel) ; 12(10)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36292057

RESUMO

Purpose: The purpose of this study was to test the technical feasibility and the impact on the image quality of a deep learning-based super-resolution reconstruction algorithm in 1.5 T abdominopelvic MR imaging. Methods: 44 patients who underwent abdominopelvic MRI were retrospectively included, of which 4 had to be subsequently excluded. After the acquisition of the conventional volume interpolated breath-hold examination (VIBEStd), images underwent postprocessing, using a deep learning-based iterative denoising super-resolution reconstruction algorithm for partial Fourier acquisitions (VIBESR). Image analysis of 40 patients with a mean age of 56 years (range 18−84 years) was performed qualitatively by two radiologists independently using a Likert scale ranging from 1 to 5, where 5 was considered the best rating. Results: Image analysis showed an improvement of image quality, noise, sharpness of the organs and lymph nodes, and sharpness of the intestine for pre- and postcontrast images in VIBESR compared to VIBEStd (each p < 0.001). Lesion detectability was better for VIBESR (p < 0.001), while there were no differences concerning the number of lesions. Average acquisition time was 16 s (±1) for the upper abdomen and 15 s (±1) for the pelvis for VIBEStd, and 15 s (±1) for the upper abdomen and 14 s (±1) for the pelvis for VIBESR. Conclusion: This study demonstrated the technical feasibility of a deep learning-based super-resolution algorithm including partial Fourier technique in abdominopelvic MR images and illustrated a significant improvement of image quality, noise, and sharpness while reducing TA.

10.
Tomography ; 8(4): 1678-1689, 2022 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-35894005

RESUMO

(1) This study evaluates the impact of an AI denoising algorithm on image quality, diagnostic accuracy, and radiological workflows in pediatric chest ultra-low-dose CT (ULDCT). (2) Methods: 100 consecutive pediatric thorax ULDCT were included and reconstructed using weighted filtered back projection (wFBP), iterative reconstruction (ADMIRE 2), and AI denoising (PixelShine). Place-consistent noise measurements were used to compare objective image quality. Eight blinded readers independently rated the subjective image quality on a Likert scale (1 = worst to 5 = best). Each reader wrote a semiquantitative report to evaluate disease severity using a severity score with six common pathologies. The time to diagnosis was measured for each reader to compare the possible workflow benefits. Properly corrected mixed-effects analysis with post-hoc subgroup tests were used. Spearman's correlation coefficient measured inter-reader agreement for the subjective image quality analysis and the severity score sheets. (3) Results: The highest noise was measured for wFBP, followed by ADMIRE 2, and PixelShine (76.9 ± 9.62 vs. 43.4 ± 4.45 vs. 34.8 ± 3.27 HU; each p < 0.001). The highest subjective image quality was measured for PixelShine, followed by ADMIRE 2, and wFBP (4 (4−5) vs. 3 (4−5) vs. 3 (2−4), each p < 0.001) with good inter-rater agreement (r ≥ 0.790; p ≤ 0.001). In diagnostic accuracy analysis, there was a good inter-rater agreement between the severity scores (r ≥ 0.764; p < 0.001) without significant differences between severity score items per reconstruction mode (F (5.71; 566) = 0.792; p = 0.570). The shortest time to diagnosis was measured for the PixelShine datasets, followed by ADMIRE 2, and wFBP (2.28 ± 1.56 vs. 2.45 ± 1.90 vs. 2.66 ± 2.31 min; F (1.000; 99.00) = 268.1; p < 0.001). (4) Conclusions: AI denoising significantly improves image quality in pediatric thorax ULDCT without compromising the diagnostic confidence and reduces the time to diagnosis substantially.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Inteligência Artificial , Criança , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tórax , Tomografia Computadorizada por Raios X/métodos , Fluxo de Trabalho
12.
Cancers (Basel) ; 14(12)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35740659

RESUMO

BACKGROUND: This study investigated whether a machine-learning-based combination of radiomics and clinical parameters was superior to the use of clinical parameters alone in predicting therapy response after three months, and overall survival after six and twelve months, in stage-IV malignant melanoma patients undergoing immunotherapy with PD-1 checkpoint inhibitors and CTLA-4 checkpoint inhibitors. METHODS: A random forest model using clinical parameters (demographic variables and tumor markers = baseline model) was compared to a random forest model using clinical parameters and radiomics (extended model) via repeated 5-fold cross-validation. For this purpose, the baseline computed tomographies of 262 stage-IV malignant melanoma patients treated at a tertiary referral center were identified in the Central Malignant Melanoma Registry, and all visible metastases were three-dimensionally segmented (n = 6404). RESULTS: The extended model was not significantly superior compared to the baseline model for survival prediction after six and twelve months (AUC (95% CI): 0.664 (0.598, 0.729) vs. 0.620 (0.545, 0.692) and AUC (95% CI): 0.600 (0.526, 0.667) vs. 0.588 (0.481, 0.629), respectively). The extended model was not significantly superior compared to the baseline model for response prediction after three months (AUC (95% CI): 0.641 (0.581, 0.700) vs. 0.656 (0.587, 0.719)). CONCLUSIONS: The study indicated a potential, but non-significant, added value of radiomics for six-month and twelve-month survival prediction of stage-IV melanoma patients undergoing immunotherapy.

13.
Tomography ; 8(2): 933-947, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35448709

RESUMO

(1) To investigate whether interventional cone-beam computed tomography (cbCT) could benefit from AI denoising, particularly with respect to patient body mass index (BMI); (2) From 1 January 2016 to 1 January 2022, 100 patients with liver-directed interventions and peri-procedural cbCT were included. The unenhanced mask run and the contrast-enhanced fill run of the cbCT were reconstructed using weighted filtered back projection. Additionally, each dataset was post-processed using a novel denoising software solution. Place-consistent regions of interest measured signal-to-noise ratio (SNR) per dataset. Corrected mixed-effects analysis with BMI subgroup analyses compared objective image quality. Multiple linear regression measured the contribution of "Radiation Dose", "Body-Mass-Index", and "Mode" to SNR. Two radiologists independently rated diagnostic confidence. Inter-rater agreement was measured using Spearman correlation (r); (3) SNR was significantly higher in the denoised datasets than in the regular datasets (p < 0.001). Furthermore, BMI subgroup analysis showed significant SNR deteriorations in the regular datasets for higher patient BMI (p < 0.001), but stable results for denoising (p > 0.999). In regression, only denoising contributed positively towards SNR (0.6191; 95%CI 0.6096 to 0.6286; p < 0.001). The denoised datasets received overall significantly higher diagnostic confidence grades (p = 0.010), with good inter-rater agreement (r ≥ 0.795, p < 0.001). In a subgroup analysis, diagnostic confidence deteriorated significantly for higher patient BMI (p < 0.001) in the regular datasets but was stable in the denoised datasets (p ≥ 0.103).; (4) AI denoising can significantly enhance image quality in interventional cone-beam CT and effectively mitigate diagnostic confidence deterioration for rising patient BMI.


Assuntos
Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Razão Sinal-Ruído
14.
Rofo ; 194(6): 644-651, 2022 06.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-35439829

RESUMO

PURPOSE: During the SARS-CoV-2 pandemic, higher education worldwide had to switch to digital formats. The purpose of this study was to evaluate CoRad-19, a digital teaching tool created by the German Radiological Society for medical students during the COVID-19 pandemic. MATERIALS AND METHODS: A total of 13 German-speaking universities implemented CoRad-19 in their curriculum and partially or completely replaced their classes with the online courses. Previous experience and contact with radiology and the participants' opinions regarding the medium of e-learning were surveyed using a custom questionnaire. The subjective level of knowledge regarding the individual modules was also surveyed before and after participation to measure learning effects. The data of 994 medical students from the participating sites were analyzed and compared intraindividually using the Friedman test. RESULTS: From 4/1/2020-10/1/2020, 451 complete data sets from a total of 994 surveys were included. E-learning was rated "very useful" both before and after course participation (4 [IQR 3-4], p = 0.527, r = 0.16). E-learning as a method was also rated as a "very good" medium both before and after participation (4 [IQR 3-4], p = 0.414, r = 0.17). After participation, participants rated radiology as particularly suitable for digital teaching (before: 3 [IQR 3-4] vs. after 4 [IQR 3-4], p = 0.005, r = 0.6). Significant learning gains were measurable in all course modules (p ≤ 0.009). Post-hoc analysis showed interest in radiology to increase significantly after course participation (p = 0.02). CONCLUSION: In the representative survey, significant learning effects were observed in all course modules. In addition, it should be particularly emphasized that the students' interest in radiology was increased by course participation. Thus, the German Radiological Society provided significant support to German-speaking medical faculties with respect to maintaining excellent education using CoRad-19. KEY POINT: · Co-Rad-19 course participation results in measurable subjective learning effects and increases student interest in radiology.. CITATION FORMAT: · Brendlin AS, Molwitz I, Oechtering TH et al. CoRad-19 - Modular Digital Teaching during the SARS-CoV-2 Pandemic. Fortschr Röntgenstr 2022; 194: 644 - 651.


Assuntos
COVID-19 , Estudantes de Medicina , Currículo , Humanos , Pandemias , SARS-CoV-2 , Ensino
15.
Rofo ; 194(9): 1012-1019, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35272363

RESUMO

PURPOSE: To investigate reduction of radiation exposure in unenhanced CT in suspicion of renal calculi using a tin-filtered high tube voltage protocol compared to a standard low-dose protocol without spectral shaping. MATERIALS AND METHODS: A phantom study using 7 human renal calculi was performed to test both protocols. 120 consecutive unenhanced CT examinations performed due to suspicion of renal calculi were included in this retrospective, monocentric study. 60 examinations were included with the standard-dose protocol (SP) (100 kV/130 mAs), whereas another 60 studies were included using a low-dose protocol (LD) applying spectral shaping with tin filtration of high tube voltages (Sn150 kV/80 mAs). Image quality was assessed by two radiologists in consensus blinded to technical parameters using an equidistant Likert scale ranging from 1-5 with 5 being the highest score. Quantitative image quality was assessed using regions of interest in abdominal organs, muscles, and adipose tissue to analyze image noise and signal-to-noise ratios (SNR). Commercially available dosimetry software was used to determine and compare effective dose (ED) and size-specific dose estimates (SSDEmean). RESULTS: All seven renal calculi of the phantom could be detected with both protocols. There was no difference regarding calcluli size between the two protocols except for the smallest one. The smallest concretion measured 1.5 mm in LD and 1.0 mm in SP (ground truth 1.5 mm). CTDIvol was 3.36 mGy in LD (DLP: 119.3 mGycm) and 8.27 mGy in SP (DLP: 293.6 mGycm). The mean patient age in SP was 47 ±â€Š17 years and in LD 49 ±â€Š13 years. Ureterolithiasis was found in 33 cases in SP and 32 cases in LD. The median concretion size was 3 mm in SP and 4 mm in LD. The median ED in LD was 1.3 mSv (interquartile range (IQR) 0.3 mSv) compared to 2.3 mSv (IQR 0.9 mSv) in SP (p < 0.001). The SSDEmean of LD was also significantly lower compared to SP with 2.4 mGy (IQR 0.4 mGy) vs. 4.8 mGy (IQR 2.3 mGy) (p < 0.001). The SNR was significantly lower in LD compared to SP (p < 0.001). However, there was no significant difference between SP and LD regarding the qualitative assessment of image quality with a median of 4 (IQR 1) for both groups (p = 0.648). CONCLUSION: Tin-filtered unenhanced abdominal CT for the detection of renal calculi using high tube voltages leads to a significant reduction of radiation exposure and yields high diagnostic image quality without a significant difference compared to the institution's standard of care low-dose protocol without tin filtration. KEY POINTS: · Tin-filtered CT for the detection of renal calculi significantly reduces radiation dose.. · The application of tin filtration provides comparable diagnostic image quality to that of SP protocols.. · An increase in image noise does not hamper diagnostic image quality.. CITATION FORMAT: · Gassenmaier S, Winkelmann MT, Magnus J et al. Low-Dose CT for Renal Calculi Detection Using Spectral Shaping of High Tube Voltage. Fortschr Röntgenstr 2022; 194: 1012 - 1019.


Assuntos
Cálculos Renais , Tomografia Computadorizada por Raios X , Adulto , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Estanho
16.
Diagnostics (Basel) ; 12(1)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35054391

RESUMO

(1) Background: To evaluate the effects of an AI-based denoising post-processing software solution in low-dose whole-body computer tomography (WBCT) stagings; (2) Methods: From 1 January 2019 to 1 January 2021, we retrospectively included biometrically matching melanoma patients with clinically indicated WBCT staging from two scanners. The scans were reconstructed using weighted filtered back-projection (wFBP) and Advanced Modeled Iterative Reconstruction strength 2 (ADMIRE 2) at 100% and simulated 50%, 40%, and 30% radiation doses. Each dataset was post-processed using a novel denoising software solution. Five blinded radiologists independently scored subjective image quality twice with 6 weeks between readings. Inter-rater agreement and intra-rater reliability were determined with an intraclass correlation coefficient (ICC). An adequately corrected mixed-effects analysis was used to compare objective and subjective image quality. Multiple linear regression measured the contribution of "Radiation Dose", "Scanner", "Mode", "Rater", and "Timepoint" to image quality. Consistent regions of interest (ROI) measured noise for objective image quality; (3) Results: With good-excellent inter-rater agreement and intra-rater reliability (Timepoint 1: ICC ≥ 0.82, 95% CI 0.74-0.88; Timepoint 2: ICC ≥ 0.86, 95% CI 0.80-0.91; Timepoint 1 vs. 2: ICC ≥ 0.84, 95% CI 0.78-0.90; all p ≤ 0.001), subjective image quality deteriorated significantly below 100% for wFBP and ADMIRE 2 but remained good-excellent for the post-processed images, regardless of input (p ≤ 0.002). In regression analysis, significant increases in subjective image quality were only observed for higher radiation doses (≥0.78, 95%CI 0.63-0.93; p < 0.001), as well as for the post-processed images (≥2.88, 95%CI 2.72-3.03, p < 0.001). All post-processed images had significantly lower image noise than their standard counterparts (p < 0.001), with no differences between the post-processed images themselves. (4) Conclusions: The investigated AI post-processing software solution produces diagnostic images as low as 30% of the initial radiation dose (3.13 ± 0.75 mSv), regardless of scanner type or reconstruction method. Therefore, it might help limit patient radiation exposure, especially in the setting of repeated whole-body staging examinations.

17.
AJR Am J Roentgenol ; 218(2): 300-309, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34523951

RESUMO

BACKGROUND. Lower extremity external fixators have complex geometries that induce pronounced metal artifact on CT. Iterative metal artifact reduction (iMAR) algorithms help reduce such artifact, although no dedicated iMAR preset exists for external fixators. OBJECTIVE. The purpose of our study was to compare iMAR presets for CT examinations in terms of quantitative metal artifact burden and subjective image quality in patients with external fixators for complex lower extremity fractures. METHODS. This retrospective study included 72 CT examinations in 56 patients (20 women, 36 men; mean age, 56 ± 18 [SD] years) with lower extremity external fixators (regular, hybrid, or monotube). Examinations were reconstructed without iMAR (hereafter referred to as "noMAR") and with three iMAR presets (iMARspine, iMARhip, iMARextremity). A radiology resident quantified metal artifact burden using software. Two radiology residents independently assessed overall image quality and diagnostic confidence using 4-point scales (4 = excellent [highest quality or highest confidence]). Techniques were compared using Bonferroni-corrected post hoc tests. Interreader agreement was assessed by intraclass correlation coefficients (ICCs). A post hoc multinomial regression model was used for predicting overall image quality. RESULTS. Mean quantitative metal artifact burden was 100,816 ± 45,558 for noMAR, 88,889 ± 44,028 for iMARspine, 82,295 ± 41,983 for iMARhip, and 81,956 ± 41,890 for iMARextremity. Overall image quality yielded an ICC of 0.94 or greater. Using pooled reader data, median overall image quality score for the regular fixator was 2 (noMAR), 3 (iMARspine and iMARhip), and 4 (iMARextremity); for the hybrid fixator, 1 (noMAR), 2 (iMARspine), and 3 (iMARhip and iMARextremity); and for the monotube fixator, 2 (noMAR), 3 (iMARspine and iMARhip), and 4 (iMARextremity). Metal artifact burden was lower and overall image quality was higher (p < .05) for iMARhip and iMARextremity than noMAR and iMARspine for all fixators (aside from image quality of iMARhip and iMARextremity vs iMARspine for regular fixators) but were not different (all, p > .05) between iMARhip and iMARextremity. Median diagnostic confidence was 4 for all fixators and reconstructions. Independent predictors of overall quality relative to noMAR were iMARspine (odds ratio [OR] = 1.92-5.51), iMARhip (OR = 5.56-31.10), and iMARextremity (OR = 7.07-38.21). All iMAR presets introduced new reconstruction artifacts for all examinations for both readers. CONCLUSION. For the three fixator types, iMARhip and iMARextremity achieved greatest metal artifact burden reduction and highest subjective image quality, although both introduced new reconstruction artifacts. CLINICAL IMPACT. CT using the two identified iMAR presets may facilitate perioperative management of external fixators.


Assuntos
Artefatos , Fixadores Externos , Fixação de Fratura/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/terapia , Extremidade Inferior/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Extremidade Inferior/lesões , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
18.
Acad Radiol ; 29(4): 514-522, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34130924

RESUMO

RATIONALE AND OBJECTIVES: Early tumor size reduction (TSR) has been explored as a prognostic factor for survival in patients with advanced melanoma in clinical trials. The purpose of this analysis is to validate, in a routine clinical milieu, the predictive capacity of TSR by 10% for overall survival (OS) and progression-free survival (PFS) and to compare its predictive performance with the RECIST 1.1 criteria. MATERIALS AND METHODS: This retrospective study was approved by the local ethics committee. A total of 152 patients with both CT before immunotherapy initiation and at first response evaluation after immunotherapy initiation were included. Prior to statistical analysis, treatment response was trichotomized as follows: Complete response and/or partial response, stable disease and progressive disease. Furthermore, response was dichotomized regarding TSR (TSR ≥ 10% and TSR < 10%). Kaplan-Meier survival estimates, Cox regression and Harrel's concordance index (C-index) were computed for prediction of overall survival and progression-free survival. RESULTS: Tumor size reduction by at least 10% significantly differentiated between patients with increased survival from the ones with decreased survival (median OS: TSR ≥ 10%: 2137 days vs. TSR < 10%: 263 days) (p < 0.001) (median PFS: TSR ≥ 10%: 590 days vs. TSR < 10%: 11 days) (p < 0.001). RECIST 1.1. criteria had a slightly higher C-index for overall survival reflecting a slight superior predictive capacity (RECIST: 0.69 vs TSR: 0.64) but a similar predictive capacity regarding progression-free survival (both: 0. 63). CONCLUSION: Early tumor size reduction serves as a simple-to-use metric which can be implemented on the first follow-up CT. Tumor size reduction by at least 10% can be considered an additional biomarker predictive of overall survival and progression-free survival in routine clinical care and not only in the context of clinical trials in patients with advanced melanoma undergoing immunotherapy. Nevertheless, RECIST-based criteria should remain the main tool of treatment response assessment until results of prospective studies validating the TSR method are available.


Assuntos
Melanoma , Seguimentos , Humanos , Imunoterapia , Melanoma/tratamento farmacológico , Melanoma/terapia , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
19.
Diagnostics (Basel) ; 11(12)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34943604

RESUMO

Over the last decades, overall survival for most cancer types has increased due to earlier diagnosis and more effective treatments. Simultaneously, whole-body MRI-(WB-MRI) has gained importance as a radiation free staging alternative to computed tomography. The aim of this study was to evaluate the diagnostic confidence and reproducibility of a novel abbreviated 20-min WB-MRI for oncologic follow-up imaging in patients with melanoma. In total, 24 patients with melanoma were retrospectively included in this institutional review board-approved study. All patients underwent three consecutive staging examinations via WB-MRI in a clinical 3 T MR scanner with an abbreviated 20-min protocol. Three radiologists independently evaluated the images in a blinded, random order regarding image quality (overall image quality, organ-based image quality, sharpness, noise, and artifacts) and regarding its diagnostic confidence on a 5-point-Likert-Scale (5 = excellent). Inter-reader agreement and reproducibility were assessed. Overall image quality and diagnostic confidence were rated to be excellent (median 5, interquartile range [IQR] 5-5). The sharpness of anatomic structures, and the extent of noise and artifacts, as well as the assessment of lymph nodes, liver, bone, and the cutaneous system were rated to be excellent (median 5, IQR 4-5). The image quality of the lung was rated to be good (median 4, IQR 4-5). Therefore, our study demonstrated that the novel accelerated 20-min WB-MRI protocol is feasible, providing high image quality and diagnostic confidence with reliable reproducibility for oncologic follow-up imaging.

20.
J Immunother Cancer ; 9(11)2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34795006

RESUMO

BACKGROUND: To assess the additive value of dual-energy CT (DECT) over single-energy CT (SECT) to radiomics-based response prediction in patients with metastatic melanoma preceding immunotherapy. MATERIAL AND METHODS: A total of 140 consecutive patients with melanoma (58 female, 63±16 years) for whom baseline DECT tumor load assessment revealed stage IV and who were subsequently treated with immunotherapy were included. Best response was determined using the clinical reports (81 responders: 27 complete response, 45 partial response, 9 stable disease). Individual lesion response was classified manually analogous to RECIST 1.1 through 1291 follow-up examinations on a total of 776 lesions (6.7±7.2 per patient). The patients were sorted chronologically into a study and a validation cohort (each n=70). The baseline DECT was examined using specialized tumor segmentation prototype software, and radiomic features were analyzed for response predictors. Significant features were selected using univariate statistics with Bonferroni correction and multiple logistic regression. The area under the receiver operating characteristic curve of the best subset was computed (AUROC). For each combination (SECT/DECT and patient response/lesion response), an individual random forest classifier with 10-fold internal cross-validation was trained on the study cohort and tested on the validation cohort to confirm the predictive performance. RESULTS: We performed manual RECIST 1.1 response analysis on a total of 6533 lesions. Multivariate statistics selected significant features for patient response in SECT (min. brightness, R²=0.112, padj. ≤0.001) and DECT (textural coarseness, R²=0.121, padj. ≤0.001), as well as lesion response in SECT (mean absolute voxel intensity deviation, R²=0.115, padj. ≤0.001) and DECT (iodine uptake metrics, R²≥0.12, padj. ≤0.001). Applying the machine learning models to the validation cohort confirmed the additive predictive power of DECT (patient response AUROC SECT=0.5, DECT=0.75; lesion response AUROC SECT=0.61, DECT=0.85; p<0.001). CONCLUSION: The new method of DECT-specific radiomic analysis provides a significant additive value over SECT radiomics approaches for response prediction in patients with metastatic melanoma preceding immunotherapy, especially on a lesion-based level. As mixed tumor response is not uncommon in metastatic melanoma, this lends a powerful tool for clinical decision-making and may potentially be an essential step toward individualized medicine.


Assuntos
Aprendizado de Máquina/normas , Melanoma/tratamento farmacológico , Melanoma/radioterapia , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Melanoma/diagnóstico por imagem , Pessoa de Meia-Idade , Estadiamento de Neoplasias