Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Curr Cardiol Rep ; 23(10): 138, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410510

RESUMO

PURPOSE OF THE REVIEW: Percutaneous closure of sinus venosus atrial septal defects (ASD) using covered stent implantation is a new and promising minimally invasive technique. New imaging tools are used to ensure preoperative anatomical characterization and preoperative guidance, which are key procedural success factors. Here we will describe and analyze these recent developments. RECENT FINDINGS: Sinus venosus ASDs present a wide variety of anatomical features which must be described and analyzed using various imaging tools, including 3D technology. Percutaneous closure is challenging, but can hasten clinical recovery compared to the gold-standard conventional open-heart surgery. The feasibility of percutaneous closure relies on precise preoperative anatomical study and on real-time guidance using a multimodal fusion imaging process. Three-dimensional modeling of sinus venosus ASD is essential to understand the large anatomical panel encountered in this pathology. Multimodal fusion imaging guidance is very useful for performing sinus venosus ASD percutaneous closure in selected patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interatrial , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Imagem Multimodal , Stents , Resultado do Tratamento
3.
Ann Cardiol Angeiol (Paris) ; 68(6): 453-461, 2019 Dec.
Artigo em Francês | MEDLINE | ID: mdl-31733689

RESUMO

Literature concerning transcutaneous symptomatic para valvular cardiac leaks closure (PVLC) after trans aortic valve implantation (TAVI) is relatively scarce. Hereby we present 2 clinical cases, one on an Edwards® Sapien 3 valve and the other one on a Medtronic® Evolut R valve. We present also the preliminary results of the 7 PVLC on TAVI included in our prospective FFPP registry during the 2 first years of enrolment (2017-2018), for a total of 158 inclusions for all valves. Seven procedures were performed on 8 leaks, using a majority of vascular plugs (3 Abbott® Amplatzer Vascular Plugs 2 (AVP2), 3 AVP3, 1 AVP4, and 1 muscular Ventricular Septal Defect (VSD) occluder). All procedures were successful without complication. At 1-month follow-up, all patients became asymptomatic. One-year follow-up was already available for 4 patients: 3 of them were symptoms free, and one-who had a second leak not suitable for PVLC-, underwent a « TAVI in TAVI ¼ procedure 2 months after PVLC. This short experience demonstrates the feasibility, the efficacy and the safety of PVLC on TAVI. We expect to be able to offer more in depth information at the end of our prospective ongoing study.


Assuntos
Fístula Anastomótica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Fístula Anastomótica/diagnóstico por imagem , Fístula Anastomótica/etiologia , Feminino , Humanos , Masculino , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Estudos Prospectivos , Desenho de Prótese , Dispositivo para Oclusão Septal
4.
Ann Cardiol Angeiol (Paris) ; 67(6): 482-488, 2018 Dec.
Artigo em Francês | MEDLINE | ID: mdl-30463686

RESUMO

AIM OF THE STUDY: To establish efficacy and security of invasive treatments for chronic thromboembolic pulmonary hypertension (CTEPH) in elderly patients (≥80 years old): pulmonary endarterectomy (PEA) and balloon pulmonary angioplasty (BPA). PATIENTS AND METHODS: Between 2014 and 2017, 549 CTEPH patients were addressed to our hospital for PEA (364 patients) or BPA (225). From this total, patients 80 years old and over were: 17 treated by PEA and 21 by BPA. Demographic characteristics as well as hemodynamic parameters, results and complications were compared for both groups (Young - Y - versus Old - O). RESULTS: Elderly BPA patients presented a higher functional class (mean O: 3,16 versus Y: 2,73; P=0,001), with similar hemodynamics parameters compared with the younger patients. Indication for BPA in the elderly was the presence of comorbidities contraindicating surgery in 33% of cases vs. 9,3% in the younger group (P=0,005). Response to treatment was comparable in both groups with significant reductions of mPAP, PVR and improvement of functional class. Complications rate was alike between groups for hemoptysis, reperfusion lesions or mortality, with the exception of a higher incidence of contrast-induced nephropathy, without need for dialysis, in the elderly group (O: 8,4% versus 2,6%; P=0,010). Elderly PEA patients were more often male (O: 76,5% versus Y: 50,1%; P=0,034) and with a lower creatinine clearance (O: 57,6±13,4 versus Y: 72,2±21,2mL/min/m2; P=0,004). Functional class, hemodynamics, surgical times and in-hospital stay was similar between groups. There is a non-significant trend towards higher in-hospital mortality in the elderly group, CONCLUSIONS: In our experience, treatment of CPC PE in elderly patients, either by PEA or BPA is effective with acceptable complication rates.


Assuntos
Angioplastia com Balão , Endarterectomia , Hipertensão Pulmonar/cirurgia , Embolia Pulmonar/cirurgia , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Feminino , Humanos , Hipertensão Pulmonar/complicações , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/complicações
5.
Ann Cardiol Angeiol (Paris) ; 66(6): 453-459, 2017 Dec.
Artigo em Francês | MEDLINE | ID: mdl-29122207

RESUMO

Emergency bedside veno-arterious ECMO implantation can be the only saving gesture in the suspicion of acute massive pulmonary embolism leading to haemodynamic failure, even before CT-scan imaging. Once the massive pulmonary embolism is confirmed it is possible to undergo surgical or percutaneous pulmonary thrombectomy, when thrombolytic therapy is contraindicated.


Assuntos
Testes Imediatos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Trombectomia , Terapia Trombolítica , Tomografia Computadorizada por Raios X , Emergências , Humanos , Embolia Pulmonar/diagnóstico , Índice de Gravidade de Doença , Trombectomia/métodos , Terapia Trombolítica/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Filtros de Veia Cava
6.
EuroIntervention ; 7: 1-2, 2011.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062728

RESUMO

Aims: We report the angiographic and clinical outcomes of patients with de novocoronary bifurcation lesions treated with the Nile PAX dedicated device.Methods and results: From Dec/08 to Mar/09, a total of 102 pts with singlebifurcation lesion were prospectively enrolled in this non-randomised, multicenter(10 sites in Europe/South America) study. Lesion criteria were vessel size 2.5-3.5mm in the parent vessel (PV) and 2.0-3.0 mm in the SB, and lesion length <14 mmin the PV. Clinical follow-up (FU) was scheduled at 1, 3, 6, 9 and 12 months, andyearly up to 5 years. Angiographic FU was scheduled at 9 months (primaryendpoint). Angiographic analysis was performed by an independent angiographiccore laboratory. Data analysis and management was performed by an independentdata coordinating center; also, all clinical events were independently adjudicatedby a clinical events committee. Mean age was 63 years, 29% had diabetes, 16previous MI, and 40% previous intervention. The LAD/Dg was the most prevalentlocation (75%), and 60% had significant involvement of both branches. In theprocedure, PV was predilated in 97%; the study stent was successfully attemptedand implanted in 99%. Overall, 25% of SB received an additional stent; and 94%of lesions had final kissing-balloon inflation. By quantitative coronary angiography,baseline mean lesion length, vessel diameter and% diameter stenosis were: 10.9mm, 2.99 mm and 72% in the PV, and 4.1 mm, 2.28 mm, and 38% in the SB, respectively. Angiographic success (residual stenosis <50%, final TIMI 3 flow, andabsence of dissection) was achieved in 98%. There was only 1 major adversecardiac event (MACE) during hospitalisation, which was adjudicated as a non-Qmyocardial infarction during hospitalisation, and no additional adverse events werereported up to 30 days...


Assuntos
Angiografia , Diabetes Mellitus , Revascularização Miocárdica
7.
Heart ; 95(8): 624-9, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19052025

RESUMO

OBJECTIVE: Recent experimental and limited clinical studies have demonstrated the usefulness of delayed enhancement multislice computed tomography (MSCT) for assessing myocardial infarct size (IS) and transmurality. The aim of this study is to compare MSCT enhancement patterns immediately after coronary angiography (CAG) in an acute myocardial infarction (AMI) setting with cardiac magnetic resonance (CMR) enhancement during the second week follow-up. METHODS: 26 patients admitted for an AMI were evaluated by MSCT immediately after CAG without iodine re-injection. All but three were reperfused. The same patients had delayed enhancement CMR imaging at 10 (SD 4)-day follow-up. Myocardial enhancement was considered transmural (non-viable) when involving >75% of myocardial thickness, subendocardial (1 - < or =75%) or normal (viable for the two latter). Two or more >75% enhanced segments were required to define transmurality on patient-level or culprit artery-level analysis. A semi-quantitative scale score was defined for the 17 left ventricular segments. IS was computed from these scores. RESULTS: On segment analysis, sensitivity, specificity, accuracy, positive and negative predictive values of MSCT for transmurality assessment were 84%, 96%, 94%, 85% and 96%, respectively, compared to CMR. On patient analysis, these respective values were 90%, 80%, 88%, 95% and 67%. IS assessed by the two methods were highly correlated (r = 0.94, p<0.0001) and the regression line did not statistically differ from the identity line. CONCLUSION: MSCT enhancement immediately following CAG without iodine re-injection for an AMI is a reliable method for evaluating transmurality and IS. This very early evaluation could be an interesting alternative to CMR.


Assuntos
Infarto do Miocárdio/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
8.
Arch Mal Coeur Vaiss ; 100(5): 373-9, 2007 May.
Artigo em Francês | MEDLINE | ID: mdl-17646760

RESUMO

The authors report their experience of endovascular treatment of coronary fistulae in 25 patients aged 2 to 77 years (median 29 years) who underwent 30 interventional catheterisation procedures. The origin of the fistulae was variable: left coronary (14 cases), right coronary (6 cases) and bilateral (5 cases) as were the sites of drainage: right atrium (5 cases), right ventricle (8 cases) pulmonary artery (7 cases) and bronchial artery (5 cases). Different materials were used: releasable balloons (9 cases), coils (17 cases), microparticles (5 cases) and Amplatzer occluder and plug (2 cases). The result, judged by occlusion or sub-occlusion of the given pedicle, was a success in 92% of cases. Total or sub-total occlusion of the fistula was obtained in 22 patients (88%); 2 patients had residual fistulae due to non-embolisation of the pedicle; in one patient, it was not possible to embolise the pedicle despite two attempts. A single serious complication, ventricular fibrillation during the catheterisation, was observed but without a sequel. Follow-up ranged from 6 to 176 months; 4 patients died of other causes, 3 were lost to follow-up; one coronaro-pulmonary fistula recurred but no other recurrence was observed in the other patients. The authors conclude that embolisation is the treatment of choice for coronary fistulae providing the cases are managed by teams trained in the use of different materials. The choice of material of embolisation should be adapted to the anatomical conditions which determine the success rate and the absence of complications.


Assuntos
Anomalias dos Vasos Coronários/terapia , Embolização Terapêutica/métodos , Adolescente , Adulto , Idoso , Fístula Artério-Arterial/terapia , Oclusão com Balão/instrumentação , Artérias Brônquicas/anormalidades , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Embolização Terapêutica/instrumentação , Feminino , Seguimentos , Átrios do Coração/anormalidades , Ventrículos do Coração/anormalidades , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/anormalidades , Recidiva , Estudos Retrospectivos , Resultado do Tratamento , Fibrilação Ventricular/etiologia
9.
Am Heart J ; 142(3): 544-8, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11526371

RESUMO

BACKGROUND: In adults with atrial septal defect (ASD) and large right-to-left shunt, closure of the defect is recommended. Percutaneous closure is still rarely used in this population. This study presents the results of transcatheter closure with the Amplatzer occluder in such patients. METHODS AND RESULTS: We studied 44 consecutive adult patients with a secundum ASD and 2 of the 3 following criteria: QP/QS >/=2 by oximetry, echocardiographic right ventricle overload, and ASD size >20 mm. Forty-two patients had a successful implantation. In 1 patient an unstable device was withdrawn; in another one, the device embolized in the pulmonary artery. At 6-month median follow-up, 95% had a complete closure; 2 patients with an additional defect had a small residual shunt. Major complications were the aforementioned embolization and a cerebrovascular accident in a patient with atrial fibrillation treated with aspirin. Others were minor and transitory: premature atrial beats in 3 patients, and paroxysmal atrial fibrillation and pulmonary edema in 1 patient each. CONCLUSIONS: Transcatheter closure of large ASDs with the Amplatzer device is efficient with less morbidity than surgical closure.


Assuntos
Cateterismo Cardíaco/métodos , Embolização Terapêutica/métodos , Comunicação Interatrial/cirurgia , Próteses Valvulares Cardíacas , Adolescente , Adulto , Idoso , Embolização Terapêutica/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias
11.
Catheter Cardiovasc Interv ; 52(3): 368-72, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11246255

RESUMO

The internal mammary artery (IMA) is currently the best graft for coronary bypass surgery and is therefore preferentially anastomosed to major arteries, usually the left anterior descending (LAD) artery. This graft may develop a stenosis, most often at the distal anastomosis. Ostial stenoses are rare and their pathophysiology uncertain. While angioplasty of distal anastomotic lesions provides adequate results, the very small number of published cases of angioplasty of ostial lesions explains the lack of knowledge on results of this type of procedure. The authors report six procedures of this type on five patients, including two with stenting. The primary success rate was 100%, with only one hospital complication in the form of pulmonary edema. Mean follow-up for 35 months revealed one sudden death due to probable restenosis, another death 3 years after angioplasty from rapid fatal shock without complementary investigation, and one case of unstable angina secondary to intrastent restenosis. These results suggest that this type of angioplasty is technically feasible with low risk, and that the restenosis rate seems relatively high, potentially presenting as sudden death, in the same way as unprotected dilatation of the native left main artery. A very close clinical follow-up of these patients is therefore necessary, with angiographic control in case of suspected ischemia.


Assuntos
Angina Instável/terapia , Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Oclusão de Enxerto Vascular/terapia , Anastomose de Artéria Torácica Interna-Coronária , Idoso , Angina Instável/diagnóstico por imagem , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Retratamento
12.
J Thorac Cardiovasc Surg ; 117(4): 787-93, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10096975

RESUMO

OBJECTIVE: The 2 main causes of death after thromboendarterectomy for chronic pulmonary thromboembolism are incomplete repermeabilization responsible for persistent pulmonary hypertension and acute high-permeability pulmonary edema. We wish to establish an experimental model of chronic pulmonary thromboembolism to replicate the conditions encountered during and after pulmonary thromboendarterectomy. METHODS: Multiple-curled coils and tissue adhesive were embolized in 6 piglets to induce complete obstruction of the left pulmonary artery, documented by angiography. After 5 weeks, the main pulmonary artery was repermeabilized by thromboendarterectomy during circulatory arrest. The left lung was reperfused ex vivo with autologous blood at constant flow, and patency of the pulmonary artery was evaluated on a barium angiogram. The endarterectomy-reperfusion procedure was also done in 6 nonembolized piglets that served as the controls. The severity of lung injury induced by 60 minutes of reperfusion was assessed on the basis of measurements of the lung filtration coefficient and of lung myeloperoxidase activity. RESULTS: Marked hypertrophy of the bronchial circulation was seen in the chronic pulmonary thromboembolism group. Thromboendarterectomy removed the organized obstructing thrombus that was incorporated into the arterial wall and restored patency of the pulmonary artery. Acute lung inflammation and high-permeability edema occurred after reperfusion, as indicated by a 1.5-fold increases in both lung filtration coefficient and lung myeloperoxidase values in the chronic pulmonary thromboembolism group; these 2 variables being correlated. CONCLUSIONS: Our model replicated the perioperative conditions of pulmonary thromboendarterectomy, suggesting that it may prove useful for improving the repermeabilization technique and for investigating the mechanisms and prevention of reperfusion injury.


Assuntos
Endarterectomia , Embolia Pulmonar/cirurgia , Animais , Doença Crônica , Hipertensão Pulmonar/etiologia , Pulmão/irrigação sanguínea , Edema Pulmonar/etiologia , Embolia Pulmonar/complicações , Distribuição Aleatória , Traumatismo por Reperfusão/prevenção & controle , Síndrome do Desconforto Respiratório/etiologia , Suínos , Grau de Desobstrução Vascular
13.
Arch Mal Coeur Vaiss ; 90(2): 245-51, 1997 Feb.
Artigo em Francês | MEDLINE | ID: mdl-9181034

RESUMO

Between June 1992 and January 1996, 27 patients aged 3.9 to 74 years with an ostium secundum (22 patients) or patent foramen ovale with right-to-left shunts (5 patients) underwent percutaneous closure of their atrial septal defects with the Sideris occluder. After a thromboembolic complication, transesophageal echocardiography was performed routinely after the procedure in 15 patients between 1 month and 2 years, and in 6 patients on the 15th day. Two patients died, on the 2nd day and 21st month, of non-related causes. After an average follow-up of 33 months, 59% of patients had complete occlusion of the atrial septal defects or only a minimal residual shunt. Displacement of the prosthesis was defects or only a minimal residual shunt. Displacement of the prosthesis was observed in 7 cases with no relationship to size: 4 parallel to the septum with reappearance or increase in shunt, 3 with tilting of the prosthesis. All of these patients had a large residual defect compared with 20% with a normally positioned prosthesis (p < 0.05). Tilting of the occluder was associated with left atrial thrombosis (present in 40% of these patients), complicated by systemic embolism in one case: there were no cases of left atrial thrombus in the 9 with complete occlusion and the 5 patients with an isolated residual defect (p < 0.05). Occlusion of atrial septal defect with the Sideris device is effective and a safe method in the majority of cases. However, a badly positioned prosthesis with a residual shunt should be extracted as seen as possible or within three weeks if displacement is observed at control echocardiography.


Assuntos
Cateterismo Cardíaco , Cateterismo/efeitos adversos , Comunicação Interatrial/terapia , Análise Atuarial , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Ecocardiografia Transesofagiana , Falha de Equipamento , Feminino , Seguimentos , Migração de Corpo Estranho/etiologia , Átrios do Coração/cirurgia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Radiologia Intervencionista , Tromboembolia/etiologia , Tromboembolia/terapia , Resultado do Tratamento
14.
Contracept Fertil Sex ; 23(11): 696-8, 1995 Nov.
Artigo em Francês | MEDLINE | ID: mdl-8520654

RESUMO

From a personal observation of a male fetus oro-genital contact we made a preliminary multicentric study which shows some rare similar cases. Others oral or manual behaviours, containing perhaps some sexual significance are frequently observed but not yet published.


Assuntos
Feto/fisiologia , Comportamento Sexual/fisiologia , Feminino , Humanos , Masculino , Gravidez , Comportamento de Sucção , Inquéritos e Questionários , Ultrassonografia Pré-Natal
15.
Presse Med ; 24(14): 665-70, 1995 Apr 08.
Artigo em Francês | MEDLINE | ID: mdl-7770413

RESUMO

OBJECTIVE: Loss or displacement of foreign material within the cardiovascular system is not an uncommon event. Foreign bodies include fragments of diagnosis equipment, ruptured catheters or malpositioned or displaced intravascular prostheses. The incidence has increased with the development of endovascular catheterism and raises the problem of extraction. METHODS: We report our experience with percutaneous extraction of intravascular foreign bodies. RESULTS: There were 56 cases. Percutaneous extraction was successful in 53. In 11 cases, the procedure was carried out during a catheterism procedure and in the others the initial event had occurred earlier. The delay to extraction varied from a few hours to several years. CONCLUSION: Percutaneous extraction of intravascular foreign bodies should be attempted before surgical removal, an often difficult high-risk procedure. The literature does not provide data on the frequency of intravascular foreign bodies.


Assuntos
Cateterismo Periférico/efeitos adversos , Cateterismo de Swan-Ganz/efeitos adversos , Corpos Estranhos/cirurgia , Filtros de Veia Cava/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Radiografia
17.
Arch Mal Coeur Vaiss ; 83(7): 983-8, 1990 Jun.
Artigo em Francês | MEDLINE | ID: mdl-2114859

RESUMO

After experiencing problems of catheterisation during coronary angioplasty, the authors tried using a 3.2 F ultraflexible catheter with a 2.2 F tapered tip. In 2 patients, initial attempts at coronary catheterisation were failures but when this new catheter was used, angioplasty could be performed without any difficulty. This catheter was then used in 4 other patients and in all cases the Tracker enabled the operators to catheterise the coronary arteries and to perform angioplasty in 3 of the 4 cases. Therefore, this new ultraflexible catheter would seem to be a valuable alternative for catheterising particularly sinuous coronary arteries in which angioplasty is often technically difficult.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Doença das Coronárias/terapia , Adulto , Idoso , Cateterismo Cardíaco/métodos , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
Pathol Biol (Paris) ; 36(4): 325-30, 1988 Apr.
Artigo em Francês | MEDLINE | ID: mdl-3287304

RESUMO

Intravenous digital angiography of the left ventricle (LV) was submitted to videodensitometric analysis in order to measure the ejection fraction (EF) and ventricular volumes. The video-densitometric method was first validated using an experimental model consisting of latex balloons filled with contrast medium. The correlation for ejection fraction measurements was satisfactory (r = 0.9449), with less than 10% errors. For ventricular volumes, the correlation was also good (r = 0.97 and 0.92 with the Chapman and Dodge methods respectively), but marked variations across individuals were found. Digital videodensitometry thus appears to be a feasible and reliable method for ejection fraction and ventricular volume measurements. Further studies are needed to determine the accuracy of measurements of ventricular volumes.


Assuntos
Volume Sistólico , Gravação em Vídeo/métodos , Densitometria , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Flebografia , Intensificação de Imagem Radiográfica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...