Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 148: 106216, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37924665

RESUMO

A human aorta from a female donor affected by Klippel-Trenaunay syndrome was retrieved during a surgery for organ donation for transplant. The aorta was preserved in refrigerated Belzer UW organ preservation solution and tested within a few hours for mechanical characterization with and without vascular smooth muscle activation. KCl and Noradrenaline were used as vasoactive agents in bubbled Krebs-Henseleit buffer solution at 37 °C. A quasi-static and a dynamic mechanical characterization of the full wall and the three individual layers were carried out for strips taken in longitudinal and circumferential directions. The full wall in the descending portion of the aorta underwent mechanical tests with and without smooth muscle activation. Results were compared to data obtained from healthy aortas and show a reduced stiffness of the full wall in circumferential direction. Also, a significant reduction of the response to vasoactive agents in circumferential direction was observed, while the longitudinal response was similar to healthy cases.


Assuntos
Aorta Torácica , Síndrome de Klippel-Trenaunay-Weber , Humanos , Feminino , Aorta Torácica/fisiologia , Aorta , Norepinefrina , Músculo Liso Vascular
2.
Acta Biomater ; 160: 59-72, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36792047

RESUMO

Decellularized porcine aortas are proposed as scaffolds for revolutionary active aortic grafts. A change in the static and dynamic mechanical properties, associated with the microstructure of elastin and collagen fibers, corresponds to alteration in the cyclic expansion and perfusion, in addition to possible graft damage. Therefore, the present study thoroughly investigates the mechanical response of the decellularized scaffolds of human and porcine origin to static and dynamic mechanical loads. The responses of the native human and porcine aortas are also compared; this is unavailable in the literature. Because the aorta is subjected to pulsatile blood pressure, dynamical responses to cyclic loads and their associated viscoelastic properties are particularly relevant for advanced graft design. In parallel, this study examines the microstructure of the decellularized aorta. The resulting data are compared to the analogous data obtained for the native human and porcine tissues. The results indicate that by using an optimized decellularization protocol - based on sodium dodecyl sulfate (SDS) and DNase - that minimizes mechanical and structural changes of the tissue, layered scaffolds with static and dynamic properties very similar to natural human aortas are obtained. In particular, a decellularized porcine aorta is non-inferior to a decellularized human aorta. STATEMENT OF SIGNIFICANCE: About 55,000 patients undergo abdominal aortic aneurysm repair annually in the USA. The currently implanted grafts present a large mechanical mismatch with the native tissue. This increases the pulsatile nature of the blood flow with negative consequences to the organ perfusion. For this reason, biomimetic and mechanically compatible grafts for aortic repair are urgently needed and they can be obtained through tissue engineering. In this study, scaffolds from porcine and human aortas are obtained from an optimized decellularization protocol. They are accurately compared to the native tissue and present the ideal static and dynamic mechanical properties for developing innovative aortic grafts.


Assuntos
Aorta , Engenharia Tecidual , Suínos , Humanos , Animais , Engenharia Tecidual/métodos , Dodecilsulfato de Sódio/química , Alicerces Teciduais , Matriz Extracelular/química
3.
J Mech Behav Biomed Mater ; 138: 105647, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36610281

RESUMO

The authors have observed that a stress-strain curve for uniaxial tension of an aortic intact wall cannot be simply obtained by combining the strain energy functions of the three individual aortic layers - intima, media and adventitia - even taking into account the interaction among the three layers; the strain energy functions of the three layers are obtained fitting tensile tests on strips from the individual layers. Due to the layer separation, the residual stresses are released and thus they do not affect the stress-strain curves of the individual layers. The present study shows that it is instead possible to fit the intact wall experimental curves with the combination of the strain energy functions of the three individual layers if residual strains are added. The residual strains are used as optimization parameters with specific constraints and allowing for the buckling (wrinkling) of the intima under unpressurized condition of the aortic wall, as experimentally observed. By varying these parameters in the experimentally observed range of values, it is possible to find a solution with the combined responses of the individual layers matching the experimental stress-strain curves of the intact wall.


Assuntos
Aorta , Túnica Íntima , Estresse Mecânico , Fenômenos Biomecânicos , Aorta/fisiologia , Túnica Média
4.
Proc Natl Acad Sci U S A ; 119(3)2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35022244

RESUMO

Experimental data and a suitable material model for human aortas with smooth muscle activation are not available in the literature despite the need for developing advanced grafts; the present study closes this gap. Mechanical characterization of human descending thoracic aortas was performed with and without vascular smooth muscle (VSM) activation. Specimens were taken from 13 heart-beating donors. The aortic segments were cooled in Belzer UW solution during transport and tested within a few hours after explantation. VSM activation was achieved through the use of potassium depolarization and noradrenaline as vasoactive agents. In addition to isometric activation experiments, the quasistatic passive and active stress-strain curves were obtained for circumferential and longitudinal strips of the aortic material. This characterization made it possible to create an original mechanical model of the active aortic material that accurately fits the experimental data. The dynamic mechanical characterization was executed using cyclic strain at different frequencies of physiological interest. An initial prestretch, which corresponded to the physiological conditions, was applied before cyclic loading. Dynamic tests made it possible to identify the differences in the viscoelastic behavior of the passive and active tissue. This work illustrates the importance of VSM activation for the static and dynamic mechanical response of human aortas. Most importantly, this study provides material data and a material model for the development of a future generation of active aortic grafts that mimic natural behavior and help regulate blood pressure.


Assuntos
Aorta/fisiologia , Fenômenos Biomecânicos , Músculo Liso Vascular/fisiologia , Adenosina , Adulto , Idoso , Alopurinol , Glutationa , Humanos , Insulina , Pessoa de Meia-Idade , Modelos Biológicos , Músculo Liso Vascular/citologia , Soluções para Preservação de Órgãos , Rafinose , Estresse Mecânico
5.
Acta Biomater ; 134: 401-421, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34303867

RESUMO

The mechanical properties of human aortas are linked to the layered tissue and its microstructure at different length scales. Each layer has specific mechanical and structural properties. While the ground substance and the elastin play an important role in tissue stiffness at small strain, collagen fibers carry most of the load at larger strains, which corresponds to the physiological conditions of the aorta at maximum pulsatile blood pressure. In fact, collagen fibers are crimped in the unloaded state. Collagen fibers show different orientation distributions when they are observed in a plane that is tangent to the aortic wall (in-plane section) or along a direction orthogonal to it (out-of-plane section). This was systematically investigated using large images (2500 × 2500 µm) with high resolution obtained by second harmonic generation (SHG) in order to homogenize tissue heterogeneity after a convergence analysis, which is a main goal of the study. In addition, collagen fibers show lateral interactions due to entanglements and the presence of transverse elastin fibers, observed on varying length scales using atomic force microscopy and a three-dimensional rendering obtained by stacking a sequence of SHG and two-photon fluorescence images; this is another important contribution. Human descending thoracic aortas from 13 heartbeat donors aged 28 to 66 years were examined. Uniaxial tensile tests were carried out on the longitudinal and circumferential strips of the aortic wall and the three separated layers (intima, media and adventitia). A structurally-motivated material model with (i) a term to describe the combined response of ground substance and elastin and (ii) terms to consider four families of collagen fibers with different directions was applied. The exclusion of compressed fibers was implemented in the fitting process of the experimental data, which was optimized by a genetic algorithm. The results show that a single fiber family with directional and dispersion parameters measured from SHG images can describe the mechanical response of all 39 layers (3 layers for each of the 13 aortas) with very good accuracy when a second (auxiliary) family of aligned fibers is introduced in the orthogonal direction to account for lateral fiber interaction. Indeed, all observed distributions of collagen directions can be accurately fitted by a single bivariate von Mises distribution. Statistical analysis of in-plane and out-of-plane dispersion of fiber orientations reveals structural differences between the three layers and a change of collagen dispersion parameters with age. STATEMENT OF SIGNIFICANCE: The stiffness of healthy young aortas is adjusted so that a diameter expansion of about 10 % is possible during the heartbeat. This creates the Windkessel effect, which smooths out the pulsating nature of blood flow and benefits organ perfusion. The specific elastic properties of the aorta that are required to achieve this effect are related to the microstructure of the aortic tissue at different length scales. An increase in the aortic stiffness, in addition to reducing cyclic expansion and worsening perfusion, is a risk factor for clinical hypertension. The present study relates the microstructure of healthy human aortas to the mechanical response and examines the changes in microstructural parameters with age, which is a key factor in increasing stiffness.


Assuntos
Aorta Torácica , Elastina , Túnica Adventícia , Aorta , Fenômenos Biomecânicos , Humanos , Estresse Mecânico
6.
Acta Biomater ; 130: 291-307, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34082105

RESUMO

Experiments were carried out on 15 human descending thoracic aortas from heart-beating healthy donors who donated organs for transplant. The aortas were kept refrigerated in organ preservation solution and tested were completed within 48 hours from explant. Donors' age was comprised between 25 and 70 years, with an average of 51.7 ± 12.8 years. Quasi-static and dynamic uniaxial tensile test were carried out in thermally controlled physiological saline solution in order to characterize the viscoelastic behavior. Strips were tested under harmonic deformation of different frequency, between 1 and 11 Hz, at three initial pre-stretches. Cyclic deformations of two different amplitudes were used: a physiological one and a small one, the latter one for comparison purposes to understand the accuracy limits of viscoelastic models. Aortic strips in circumferential and longitudinal directions were cut from each aorta. Some strips were dissected to separate the three layers: intima, media and adventitia. They were tested individually in order to obtain layer-specific data. However, strips of the intact wall were also tested. Therefore, 8 strips per donors were tested. Viscoelastic parameters are accurately evaluated from the hysteresis loops. Results show that small-amplitude cyclic strain over-estimate the storage modulus and under-estimate the loss-factor. Therefore, cyclic deformation of physiological amplitude is necessary to obtain correct viscoelastic data of aortic tissue. The value of the applied pre-stretch is significant on the dynamic stiffness ratio (storage modulus divided by the corresponding quasi-static stiffness), while it is less significant for the loss factor. The median of the dynamic stiffness ratios, in physiological conditions, varies between 1.14 and 1.33 for the different layers and the intact wall; the corresponding median of the loss factors varies between 0.050 and 0.066. The lowest dynamic stiffness ratios and loss factors were obtained from donors of the youngest age group. STATEMENT OF SIGNIFICANCE: There is an increasing interest in replacing traditional Dacron grafts used to repair thoracic aortas after acute dissection and aneurysm, with grafts in innovative biomaterials that mimic the mechanical properties and the dynamic behavior of the aorta. The human aorta is a complex laminated structure with hyperelastic and viscoelastic material properties and residual stresses. This study aims to characterize the nonlinear viscoelastic properties of ex-vivo human descending thoracic aortas by measuring hysteresis loops of physiological amplitude under harmonic strain. Results show the necessity to characterize the viscoelastic material properties of the aorta under physiological conditions, as well as the necessity to introduce improved models that take better into account the influence of the initial pre-stretch and amplitude of the cyclic load.


Assuntos
Aorta Torácica , Aorta , Adulto , Túnica Adventícia , Idoso , Fenômenos Biomecânicos , Elasticidade , Coração , Humanos , Pessoa de Meia-Idade , Estresse Mecânico
7.
J Biomech ; 110: 109978, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32827785

RESUMO

Aortic dissection is one of the most lethal cardiovascular diseases. A chronic Type A (Stanford) dissected aorta was retrieved for research from a 73-year-old male donor without diagnosed genetic disease. The aorta presented a dissection over the full length, and it reached a diameter of 7.7 cm in its ascending portion. The descending thoracic aorta underwent layer-specific quasi-static and dynamic mechanical characterizations after layer separation. Mechanical tests showed a physiological (healthy) behavior of the intima and some mechanical anomalies of the media and the adventitia. In particular, the static stiffness of both these layers at smaller strains was three times smaller than any one measured for twelve healthy aortas. When the viscoelastic properties were tested, adventitia presented a larger relative increase of the dynamic stiffness at 3 Hz with respect to most of the healthy aortas. The loss factor of the adventitia, which is associated with dissipation, was at the lower limit of those measured for healthy aortas. It seems reasonable to attribute these anomalies of the mechanical properties exhibited by the media and the adventitia to the severe remodeling secondary to the chronic nature of the dissection. However, it cannot be excluded that some of the mechanical anomalies were present before remodeling.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Túnica Adventícia , Idoso , Aorta , Aorta Torácica , Fenômenos Biomecânicos , Humanos , Masculino , Estresse Mecânico
8.
J Mech Behav Biomed Mater ; 99: 27-46, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31330442

RESUMO

A layer-specific hyperelastic and viscoelastic characterization of human descending thoracic aortas was experimentally performed. Healthy aortas from twelve beating heart donors with an average age of 49.4 years, were received from Transplant Québec. Axial and circumferential strips were prepared from the specimens. They were dissected into intima, media and adventitia layers. Measurements of the opening angles were used to identify the circumferential residual stresses. Uniaxial tensile tests on axial and circumferential strips, together with the Gasser-Ogden-Holzapfel material model, were used to characterize the hyperelastic behaviour of the three aortic layers for each donor. Uniaxial harmonic excitations at different frequency, superimposed to initial stretch values, were used to characterize the viscoelastic behaviour. The storage modulus and the loss tangent were obtained for each layer in both directions; comparison to intact aortic wall was also performed. The generalized Maxwell model, within the framework of nonlinear viscoelasticity with internal variables, was used to obtain the constitutive material parameters. Results showed a positive correlation (p < 0.05 for circumferential media and adventitia) between stiffness and donor age for the three layers of the aorta in both axial and circumferential directions. A significant increase (around 50%) of the storage modulus (i.e. dynamic stiffness) was observed between the quasi-static value and loading at 1 Hz frequency, while further increase in frequency marginally affected its value. The loss tangent was only slightly influenced by the stretch value, which justified the use of the viscoelastic model adopted. Finally, similar loss tangent values were found for the three aortic layers.


Assuntos
Aorta Torácica/fisiologia , Elasticidade , Viscosidade , Adulto , Túnica Adventícia/fisiologia , Idoso , Fenômenos Biomecânicos , Feminino , Coração/fisiologia , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Pressão , Estresse Mecânico , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...