Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Oncogene ; 32(7): 849-60, 2013 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-22469976

RESUMO

Liver metastasis is the predominant cause of colorectal cancer (CRC)-related mortality in developed countries. Carcinoembryonic antigen-related cell adhesion molecule 1 (CEACAM1) is a cell adhesion molecule with reduced expression in early phases of CRC development and thus functions as a tumor growth inhibitor. However, CEACAM1 is upregulated in metastatic colon cancer, suggesting a bimodal role in CRC progression. To investigate the role of this protein in the host metastatic environment, Ceacam1(-/-) mice were injected intrasplenically with metastatic MC38 mouse CRC cells. A significant reduction in metastatic burden was observed in Ceacam1(-/-) compared with wild-type (WT) livers. Intravital microscopy showed decreased early survival of MC38 cells in Ceacam1(-/-) endothelial environment. Metastatic cell proliferation within the Ceacam1(-/-) livers was also diminished. Bone marrow-derived cell recruitment, attenuation of immune infiltrates and diminished CCL2, CCL3 and CCL5 chemokine production participated in the reduced Ceacam1(-/-) metastatic phenotype. Transplantations of WT bone marrow (BM) into Ceacam1(-/-) mice fully rescued metastatic development, whereas Ceacam1(-/-) BM transfer into WT mice showed reduced metastatic burden. Chimeric immune cell profiling revealed diminished recruitment of CD11b(+)Gr1(+) myeloid-derived suppressor cells (MDSCs) to Ceacam1(-/-) metastatic livers and adoptive transfer of MDSCs confirmed the involvement of these immune cells in reduction of liver metastasis. CEACAM1 may represent a novel metastatic CRC target for treatment.


Assuntos
Antígeno Carcinoembrionário/fisiologia , Carcinoma/patologia , Neoplasias Colorretais/patologia , Animais , Antígeno Carcinoembrionário/genética , Antígeno Carcinoembrionário/metabolismo , Carcinoma/irrigação sanguínea , Carcinoma/genética , Proliferação de Células , Sobrevivência Celular , Neoplasias Colorretais/irrigação sanguínea , Neoplasias Colorretais/genética , Fígado/metabolismo , Fígado/patologia , Camundongos , Camundongos Knockout , Modelos Biológicos , Metástase Neoplásica , Neovascularização Patológica/genética , Especificidade de Órgãos/genética , Células Tumorais Cultivadas
2.
Phys Med Biol ; 56(3): 811-27, 2011 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-21239846

RESUMO

The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices. Here, we explore its use for calculating electron dose distributions in water. Mono-energetic electron dose point kernels and pencil beam kernels in water are calculated for different energies between 15 keV and 20 MeV by means of GATE 6.0, which makes use of the GEANT4 version 9.2 Standard Electromagnetic Physics Package. The results are compared to the well-validated codes EGSnrc and MCNP4C. It is shown that recent improvements made to the GEANT4/GATE software result in significantly better agreement with the other codes. We furthermore illustrate several issues of general interest to GATE and GEANT4 users who wish to perform accurate simulations involving electrons. Provided that the electron step size is sufficiently restricted, GATE 6.0 and EGSnrc dose point kernels are shown to agree to within less than 3% of the maximum dose between 50 keV and 4 MeV, while pencil beam kernels are found to agree to within less than 4% of the maximum dose between 15 keV and 20 MeV.


Assuntos
Elétrons , Método de Monte Carlo , Tomografia por Emissão de Pósitrons , Radiometria , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único , Água
3.
Stud Health Technol Inform ; 138: 34-48, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18560106

RESUMO

The paper describes a platform developed for the secure management and analysis of medical data and images in a grid environment. Designed for telemedicine and built upon the EGEE gLite middleware and particularly the metadata catalogue AMGA as well as the GridSphere web portal, the platform provides to healthcare professionals the capacity to upload and query medical information stored over distributed servers. A job submission environment is also available for data analysis. Security features include authentication and authorization by grid certificates, anonymization of medical data and image encryption. The platform is currently deployed on several sites in Europe and Asia and is being customized for applications in the field of telemedicine and medical physics.


Assuntos
Segurança Computacional/instrumentação , Sistemas Computacionais , Computação em Informática Médica , Sistemas Computadorizados de Registros Médicos/organização & administração , Telemedicina/organização & administração , Acesso à Informação , Algoritmos , Bases de Dados como Assunto , França , Humanos , Método de Monte Carlo , Neurocirurgia/organização & administração , Software
4.
Stud Health Technol Inform ; 138: 238-78, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18560124

RESUMO

The HealthGrid White Paper was published at the third annual conference in Oxford in 2005. Starting from the conclusions of the White Paper, the EU funded SHARE project (http://www.eu-share.org) has aimed at identifying the most important steps and significant milestones towards wide deployment and adoption of healthgrids in Europe. The project has defined a strategy to address the issues identified in the action plan for European e-Health (COM(2004).356) and has devised a roadmap for the major technological and ethical and legal developments and social and economic investments needed for successful take up of healthgrids in the next 10 years. A "beta" version of the road map underwent full review by a panel of 25 prominent European experts at a workshop in December 2007. The present document is an executive policy summary of the final draft road map. It has sought to reconcile likely conflicts between technological developments and regulatory frameworks by bringing together the project's technical road map and conceptual map of ethical and legal issues and socio-economic prospects. A key tool in this process was a collection of case studies of healthgrid applications.


Assuntos
Pesquisa Biomédica , Redes de Comunicação de Computadores/organização & administração , Sistemas Computacionais , Computação em Informática Médica , Acesso à Informação , Segurança Computacional , Comportamento Cooperativo , Europa (Continente) , Humanos , Desenvolvimento de Programas
5.
Phys Med Biol ; 53(11): 3039-55, 2008 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-18490808

RESUMO

The GATE Monte Carlo simulation platform based on the Geant4 toolkit has now become a diffused tool for simulating PET and SPECT imaging devices. In this paper, we explore its relevance for dosimetry of low-energy 125I photon brachytherapy sources used to treat prostate cancers. To that end, three 125-iodine sources widely used in prostate cancer brachytherapy treatment have been modelled. GATE simulations reproducing dosimetric reference observables such as radial dose function g(r), anisotropy function F(r, theta) and dose-rate constant (Lambda) were performed in liquid water. The calculations were splitted on the EGEE grid infrastructure to reduce the computing time of the simulations. The results were compared to other relevant Monte Carlo results and to measurements published and fixed as recommended values by the AAPM Task Group 43. GATE results agree with consensus values published by AAPM Task Group 43 with an accuracy better than 2%, demonstrating that GATE is a relevant tool for the study of the dose induced by low-energy photons.


Assuntos
Simulação por Computador , Fótons/uso terapêutico , Neoplasias da Próstata/diagnóstico por imagem , Anisotropia , Braquiterapia/métodos , Humanos , Radioisótopos do Iodo , Masculino , Método de Monte Carlo , Cintilografia
6.
IEEE Trans Inf Technol Biomed ; 12(2): 173-81, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18348947

RESUMO

Through this paper, we call for a distributed, Internet-based collaboration to address one of the worst plagues of our present world, malaria. The spirit is a nonproprietary peer-production of information-embedding goods. And we propose to use the grid technology to enable such a worldwide "open-source" like collaboration. The first step toward this vision has been achieved during the summer 2005 on the enabling grids for E-scienceE (EGEE) grid infrastructure where 42 million ligands were docked for a total amount of 80 CPU years in 6 weeks in the quest for new drugs. The impact of this first deployment has significantly raised the interest of the research community so that several laboratories all around the world expressed interest to propose targets for a second large-scale deployment against malaria.


Assuntos
Antimaláricos/uso terapêutico , Sistemas de Gerenciamento de Base de Dados , Desenho de Fármacos , Métodos Epidemiológicos , Internet , Malária/epidemiologia , Malária/prevenção & controle , Biologia Computacional/métodos , Comportamento Cooperativo , Humanos , Disseminação de Informação/métodos , Internacionalidade
7.
IEEE Trans Nanobioscience ; 6(2): 131-5, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17695747

RESUMO

Update of molecular biology databases is a growing burden on the biomedical research community. As the grid allows to share and replicate data, we propose a service to automatically update the molecular biology databases from a single changing reference using Web services. In this paper we report the components, the architecture, and the deployment of the update service on the french RUGBI grid infrastructure. RUGBI is a computing grid infrastructure based on existing middleware and technologies for the community of scientists in bioinformatics.


Assuntos
Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Armazenamento e Recuperação da Informação/métodos , Internet , Biologia Molecular/métodos , Interface Usuário-Computador , França
9.
J Clin Monit Comput ; 19(4-5): 339-49, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16328948

RESUMO

Grids have emerged as a promising technology to handle the data and compute intensive requirements of many application areas. Digital medical image processing is a promising application area for grids. Given the volume of data, the sensitivity of medical information, and the joint complexity of medical datasets and computations expected in clinical practice, the challenge is to fill the gap between the grid middleware and the requirements of clinical applications. The research project AGIR (Grid Analysis of Radiological Data) presented in this paper addresses this challenge through a combined approach: on one hand, leveraging the grid middleware through core grid medical services which target the requirements of medical data processing applications; on the other hand, grid-enabling a panel of applications ranging from algorithmic research to clinical applications.


Assuntos
Redes de Comunicação de Computadores , Processamento de Imagem Assistida por Computador , Integração de Sistemas , Armazenamento e Recuperação da Informação
10.
Phys Med Biol ; 50(16): 3739-54, 2005 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-16077224

RESUMO

In single photon emission computed tomography (SPECT) with parallel hole collimation, image reconstruction is usually performed as a set of bidimensional (2D) analytical or iterative reconstructions. This approach ignores the tridimensional (3D) nature of scatter and detector response function that affects the detected signal. To deal with the 3D nature of the image formation process, iterative reconstruction can be used by considering a 3D projector modelling the 3D spread of photons. In this paper, we investigate the value of using accurate Monte Carlo simulations to determine the 3D projector used in a fully 3D Monte Carlo (F3DMC) reconstruction approach. Given the 3D projector modelling all physical effects affecting the imaging process, the reconstruction problem is solved using the maximum likelihood expectation maximization (MLEM) algorithm. To validate the concept, three data sets were simulated and F3DMC was compared with two other 3D reconstruction strategies using analytical corrections for attenuation, scatter and camera point spread function. Results suggest that F3DMC improves spatial resolution, relative and absolute quantitation and signal-to-noise ratio. The practical feasibility of the approach on real data sets is discussed.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/métodos , Algoritmos , Simulação por Computador , Estudos de Viabilidade , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Funções Verossimilhança , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Reprodutibilidade dos Testes , Espalhamento de Radiação , Estatística como Assunto , Tomografia Computadorizada de Emissão
12.
Methods Inf Med ; 44(2): 154-60, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15924166

RESUMO

OBJECTIVES: In this paper we study the impact of executing a medical image database query application on the grid. For lowering the total computation time, the image database is partitioned into subsets to be processed on different grid nodes. METHODS: A theoretical model of the application complexity and estimates of the grid execution overhead are used to efficiently partition the database. RESULTS: We show results demonstrating that smart partitioning of the database can lead to significant improvements in terms of total computation time. CONCLUSIONS: Grids are promising for content-based image retrieval in medical databases.


Assuntos
Armazenamento e Recuperação da Informação , Internacionalidade , Internet , Sistemas de Informação em Radiologia , Integração de Sistemas , Telerradiologia , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Humanos , Desenvolvimento de Programas
13.
Methods Inf Med ; 44(2): 186-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15924172

RESUMO

BACKGROUND: The training of local clinicians is the best way to raise the standard of medical knowledge in developing countries. This requires transferring skills, techniques and resources. OBJECTIVES: Grid technology opens new perspectives for preparation and follow-up of medical missions in developing countries as well as support to local medical centers in terms of teleconsulting, telediagnosis and patient follow-up. Indeed, grids allow to hide the complexity of handling distributed data in such a way that physicians will be able to access patient data while ignoring where these data are stored. METHODS: To meet requirements of a development project of the French NPO Chain of Hope in China, we propose to deploy a grid-based federation of databases. FIRST RESULTS AND CONCLUSIONS: A first protocol was established for describing the patients' pathologies and their pre- and post-surgery states through a web interface in a language-independent way. This protocol was evaluated by French and Chinese clinicians during medical missions in the fall of 2003. The first sets of medical patients recorded in the databases will be used to evaluate grid implementation of services.


Assuntos
Altruísmo , Países em Desenvolvimento , Educação Médica/métodos , Sistemas de Informação Hospitalar , Internacionalidade , Internet , Integração de Sistemas , Telemedicina , China , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , França , Humanos , Organizações sem Fins Lucrativos , Cuidados Pré-Operatórios , Desenvolvimento de Programas
14.
Phys Med Biol ; 49(19): 4543-61, 2004 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-15552416

RESUMO

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.


Assuntos
Simulação por Computador , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Método de Monte Carlo , Reprodutibilidade dos Testes , Termodinâmica
15.
Phys Rev Lett ; 93(12): 122001, 2004 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-15447252

RESUMO

We report a virtual Compton scattering study of the proton at low c.m. energies. We have determined the structure functions P(LL)-P(TT)/epsilon and P(LT), and the electric and magnetic generalized polarizabilities (GPs) alpha(E)(Q2) and beta(M)(Q2) at momentum transfer Q(2)=0.92 and 1.76 GeV2. The electric GP shows a strong falloff with Q2, and its global behavior does not follow a simple dipole form. The magnetic GP shows a rise and then a falloff; this can be interpreted as the dominance of a long-distance diamagnetic pion cloud at low Q2, compensated at higher Q2 by a paramagnetic contribution from piN intermediate states.

16.
Phys Med Biol ; 49(2): 271-85, 2004 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-15083671

RESUMO

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99mTc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 microns. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.


Assuntos
Câmaras gama , Animais , Simulação por Computador , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas , Espalhamento de Radiação , Sensibilidade e Especificidade , Software
17.
J Biomed Inform ; 37(1): 30-42, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15016384

RESUMO

In this paper, we review the results of BIOINFOMED, a study funded by the European Commission (EC) with the purpose to analyse the different issues and challenges in the area where Medical Informatics and Bioinformatics meet. Traditionally, Medical Informatics has been focused on the intersection between computer science and clinical medicine, whereas Bioinformatics have been predominantly centered on the intersection between computer science and biological research. Although researchers from both areas have occasionally collaborated, their training, objectives and interests have been quite different. The results of the Human Genome and related projects have attracted the interest of many professionals, and introduced new challenges that will transform biomedical research and health care. A characteristic of the 'post genomic' era will be to correlate essential genotypic information with expressed phenotypic information. In this context, Biomedical Informatics (BMI) has emerged to describe the technology that brings both disciplines (BI and MI) together to support genomic medicine. In recognition of the dynamic nature of BMI, institutions such as the EC have launched several initiatives in support of a research agenda, including the BIOINFOMED study.


Assuntos
Biologia Computacional/métodos , Atenção à Saúde/métodos , Testes Genéticos/métodos , Terapia Genética/métodos , Genômica/métodos , Informática Médica/métodos , Projetos de Pesquisa , Biotecnologia/métodos , Biotecnologia/tendências , Biologia Computacional/tendências , Atenção à Saúde/tendências , União Europeia , Previsões , Perfilação da Expressão Gênica/métodos , Perfilação da Expressão Gênica/tendências , Testes Genéticos/tendências , Terapia Genética/tendências , Genômica/instrumentação , Programas Governamentais , Informática Médica/tendências , Pesquisa/tendências , Avaliação da Tecnologia Biomédica
18.
Methods Inf Med ; 42(2): 143-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12743650

RESUMO

BACKGROUND: The availability of large amounts of data in heterogeneous formats and the rapid progress in fields such as computer based drug design, medical imaging and medical simulations have lead to a growing demand for large computational power and easy accessibility to heterogeneous data sources. OBJECTIVES: The goal is to address these needs by deploying computing grids. Grids provide both large scale and distributed storage facilities and an increased computing power. Moreover, Grids are a promising tool to foster the synergy between bioinformatics and computerised medical imaging. METHODS: A first biomedical grid is being deployed within the framework of the DataGrid IST project (http://www.edg.org). The goal of the project is to provide a novel environment to support globally distributed scientific exploration involving up to multi-Perabyte datasets. RESULTS AND CONCLUSIONS: The first biomedical applications deployed inside the project demonstrate the relevance of the grid paradigm for genomics and medical image processing. They also highlight the specific requirements of the biomedical community.


Assuntos
Pesquisa Biomédica , Biologia Computacional/organização & administração , Simulação por Computador , Genômica , Diagnóstico por Imagem , Europa (Continente) , Humanos
19.
J Viral Hepat ; 9(1): 29-35, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11851900

RESUMO

The role of hepatitis C virus (HCV) heterogeneity in the severity of chronic hepatitis C infection remains unclear. Our aim was to study the hypervariable region 1 (HVR1) heterogeneity in patients with chronic hepatitis C infected with genotype 1b or 3 and with normal or abnormal alanine aminotransferase (ALT). HVR1 quasispecies were assessed by single strand conformational polymorphism (SSCP) in 67 patients with chronic hepatitis C, including 35 with persistently normal ALT and 32 with abnormal ALT. Sixty-two patients underwent a liver biopsy. Among the 67 patients, 40 were infected with genotype 1b and 27 with genotype 3. In univariate analysis, low heterogeneity (

Assuntos
Alanina Transaminase/sangue , Hepatite C Crônica/enzimologia , Proteínas Virais/genética , Adulto , Heterogeneidade Genética , Genótipo , Hepacivirus/genética , Hepatite C Crônica/sangue , Hepatite C Crônica/virologia , Humanos , Análise Multivariada , Polimorfismo Conformacional de Fita Simples , RNA Viral/sangue , Carga Viral
20.
Hepatology ; 34(5): 1000-5, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11679971

RESUMO

A significant proportion of patients with detectable antibodies to hepatitis C virus have normal serum alanine transaminase levels. Our aim was to study the outcome of this group. Between 1992 and 1999, 135 consecutive anti-HCV-positive patients with persistently normal ALT were followed for 3.6 +/- 2.3 years (0.5 to 8.5 years), 108 had a liver biopsy at inclusion, and 24 had a second liver biopsy 3.5 +/- 1.0 years later. Serum HCV RNA was detectable with PCR in 94 patients (69%) and not detectable in 41 patients (31%). Patients with and without detectable serum HCV RNA had similar epidemiological characteristics. Serum ALT levels and anti-HCV ratio were lower (P =.001), and histological lesions had lower grade and stage in patients without detectable serum HCV RNA (P =.001). Liver HCV RNA was not detectable with PCR in the 12-serum HCV RNA-negative patients tested. During follow-up, all patients without detectable serum HCV RNA remained HCV RNA-negative and kept normal serum ALT; all patients with detectable serum HCV RNA remained HCV RNA-positive, 20 (21%) had a slight fluctuation of serum ALT above the upper limit of normal. No significant changes were observed in the liver lesions of the 24 patients who underwent a second liver biopsy. In anti-HCV-positive patients with persistently normal serum ALT, histological lesions are significantly lower in HCV RNA-negative than in HCV RNA-positive patients. During follow-up, the HCV RNA status of patients remained unchanged; 21% of the patients with detectable serum HCV RNA had slight increase in serum ALT levels, but histological lesions remained stable.


Assuntos
Alanina Transaminase/sangue , Hepacivirus/genética , Anticorpos Anti-Hepatite C/análise , RNA Viral/sangue , Adulto , Biópsia , Feminino , Humanos , Fígado/metabolismo , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , RNA Viral/metabolismo , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA