Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113502, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461505

RESUMO

During inertial confinement fusion experiments at the National Ignition Facility (NIF), a capsule filled with deuterium and tritium (DT) gas, surrounded by a DT ice layer and a high-density carbon ablator, is driven to the temperature and densities required to initiate fusion. In the indirect method, 2 MJ of NIF laser light heats the inside of a gold hohlraum to a radiation temperature of 300 eV; thermal x rays from the hohlraum interior couple to the capsule and create a central hotspot at tens of millions degrees Kelvin and a density of 100-200 g/cm3. During the laser interaction with the gold wall, m-band x rays are produced at ∼2.5 keV; these can penetrate into the capsule and preheat the ablator and DT fuel. Preheat can impact instability growth rates in the ablation front and at the fuel-ablator interface. Monitoring the hohlraum x-ray spectrum throughout the implosion is, therefore, critical; for this purpose, a Multilayer Mirror (MLM) with flat response in the 2-4 keV range has been installed in the NIF 37° Dante calorimeter. Precision engineering and x-ray calibration of components mean the channel will report 2-4 keV spectral power with an uncertainty of ±8.7%.

2.
Rev Sci Instrum ; 85(1): 013503, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24517761

RESUMO

CEA implemented an absolutely calibrated broadband soft X-ray spectrometer called DMX on the Omega laser facility at the Laboratory for Laser Energetics (LLE) in 1999 to measure radiant power and spectral distribution of the radiation of the Au plasma. The DMX spectrometer is composed of 20 channels covering the spectral range from 50 eV to 20 keV. The channels for energies below 1.5 keV combine a mirror and a filter with a coaxial photo-emissive detector. For the channels above 5 keV the photoemissive detector is replaced by a conductive detector. The intermediate energy channels (1.5 keV < photon energy < 5 keV) use only a filter and a coaxial detector. A further improvement of DMX consists in flat-response X-ray channels for a precise absolute measurement of the photon flux in the photon energy range from 0.1 keV to 6 keV. Such channels are equipped with a filter, a Multilayer Mirror (MLM), and a coaxial detector. We present as an example the development of channel for the gold M emission lines in the photon energy range from 2 keV to 4 keV which has been successfully used on the OMEGA laser facility. The results of the radiant power measurements with the new MLM channel and with the usual channel composed of a thin titanium filter and a coaxial detector (without mirror) are compared. All elements of the channel have been calibrated in the laboratory of the Physikalisch-Technische Bundesanstalt, Germany's National Metrology Institute, at the synchrotron radiation facility BESSY II in Berlin using dedicated well established and validated methods.

3.
J Xray Sci Technol ; 4(3): 200-16, 1994 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21307493

RESUMO

Grazing x-ray reflectometry allows analysis of thin-layer stacks. The fitting of the reflectivity curve by a trial and error method can determine the parameters of the films. The Fourier analysis of the experimental reflectivity curve can directly give a rough determination of the profile index. Such results can be useful in choosing a starting model. With the choice of an appropriate model a fit to the reflectivity curve can be undertaken to determine the parameters of the stack. The Fourier analysis method can only be used if the reflectivity data undergo a transformation to produce a periodic curve. Associated artifacts are studied and discussed. Each Fourier peak is associated with two interfaces. The interface roughness spreads the Fourier peaks, adding the squared roughness values. The sample's absorption of the x-rays does not limit the Fourier analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...