Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Alzheimers Res Ther ; 15(1): 215, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38093366

RESUMO

BACKGROUND: NeuroEPO plus is a recombinant human erythropoietin without erythropoietic activity and shorter plasma half-life due to its low sialic acid content. NeuroEPO plus prevents oxidative damage, neuroinflammation, apoptosis and cognitive deficit in an Alzheimer's disease (AD) models. The aim of this study was to assess efficacy and safety of neuroEPO plus. METHODS: This was a double-blind, randomized, placebo-controlled, phase 2-3 trial involving participants ≥ 50 years of age with mild-to-moderate AD clinical syndrome. Participants were randomized in a 1:1:1 ratio to receive 0.5 or 1.0 mg of neuroEPO plus or placebo intranasally 3 times/week for 48 weeks. The primary outcome was change in the 11-item cognitive subscale of the AD Assessment Scale (ADAS-Cog11) score from baseline to 48 weeks (range, 0 to 70; higher scores indicate greater impairment). Secondary outcomes included CIBIC+, GDS, MoCA, NPI, Activities of Daily Living Scales, cerebral perfusion, and hippocampal volume. RESULTS: A total of 174 participants were enrolled and 170 were treated (57 in neuroEPO plus 0.5 mg, 56 in neuroEPO plus 1.0 mg and 57 in placebo group). Mean age, 74.0 years; 121 (71.2%) women and 85% completed the trial. The median change in ADAS-Cog11 score at 48 weeks was -3.0 (95% CI, -4.3 to -1.7) in the 0.5 mg neuroEPO plus group, -4.0 (95% CI, -5.9 to -2.1) in the 1.0 mg neuroEPO plus group and 4.0 (95% CI, 1.9 to 6.1) in the placebo group. The difference of neuroEPO plus 0.5 mg vs. placebo was 7.0 points (95% CI, 4.5-9.5) P = 0.000 and between the neuroEPO plus 1.0 mg vs. placebo was 8.0 points (95% CI, 5.2-10.8) P = 0.000. NeuroEPO plus treatment induced a statistically significant improvement in some of clinical secondary outcomes vs. placebo including CIBIC+, GDS, MoCA, NPI, and the brain perfusion. CONCLUSIONS: Among participants with mild-moderate Alzheimer's disease clinical syndrome, neuroEPO plus improved the cognitive evaluation at 48 weeks, with a very good safety profile. Larger trials are warranted to determine the efficacy and safety of neuroEPO plus in Alzheimer's disease. TRIAL REGISTRATION: https://rpcec.sld.cu Identifier: RPCEC00000232.


Assuntos
Doença de Alzheimer , Transtornos Cognitivos , Disfunção Cognitiva , Idoso , Feminino , Humanos , Masculino , Atividades Cotidianas , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/psicologia , Transtornos Cognitivos/tratamento farmacológico , Método Duplo-Cego , Resultado do Tratamento
2.
J Alzheimers Dis ; 79(1): 85-94, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33216033

RESUMO

BACKGROUND: Rapid technological advances offer a possibility to develop cost-effective digital cognitive assessment tools. However, it is unclear whether these measures are suitable for application in populations from Low and middle-income countries (LMIC). OBJECTIVE: To examine the accuracy and validity of the Brain Health Assessment (BHA) in detecting cognitive impairment in a Cuban population. METHODS: In this cross-sectional study, 146 participants (cognitively healthy = 53, mild cognitive impairment (MCI) = 46, dementia = 47) were recruited at primary care and tertiary clinics. The main outcomes included: accuracy of the BHA and the Montreal Cognitive Assessment (MoCA) in discriminating between controls and cognitively impaired groups (MCI and dementia) and correlations between the BHA subtests of memory, executive functions, and visuospatial skills and criterion-standard paper-and-pencil tests in the same domains. RESULTS: The BHA had an AUC of 0.95 (95% CI: 0.91-0.98) in discriminating between controls and cognitively impaired groups (MCI and dementia, combined) with 0.91 sensitivity at 0.85 specificity. In discriminating between control and MCI groups only, the BHA tests had an AUC of 0.94 (95% CI: 0.90-0.99) with 0.71 sensitivity at 0.85 specificity. Performance was superior to the MoCA across all diagnostic groups. Concurrent and discriminant validity analyses showed moderate to strong correlations between the BHA tests and standard paper-and-pencil measures in the same domain and weak correlations with standard measures in unrelated domains. CONCLUSION: The BHA has excellent performance characteristics in detecting cognitive impairment including dementia and MCI in a Hispanic population in Cuba and outperformed the MoCA. These results support potential application of digital cognitive assessment for older adults in LMIC.


Assuntos
Disfunção Cognitiva/diagnóstico , Computadores de Mão , Demência/diagnóstico , Testes Neuropsicológicos , Idoso , Doença de Alzheimer/diagnóstico , Afasia Primária Progressiva/diagnóstico , Cuba , Demência Vascular/diagnóstico , Países em Desenvolvimento , Função Executiva , Demência Frontotemporal/diagnóstico , Humanos , Memória , Testes de Estado Mental e Demência , Pessoa de Meia-Idade , Processamento Espacial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...