Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Biosens Bioelectron ; 78: 126-131, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-26599482

RESUMO

In this manuscript, a microfluidic detection module, which allows a sensitive readout of biological assays in point-of-care (POC) tests, is presented. The proposed detection module consists of a microfluidic flow cell with an integrated Complementary Metal-Oxide-Semiconductor (CMOS)-based single photon counting optical sensor. Due to the integrated sensor-based readout, the detection module could be implemented as the core technology in stand-alone POC tests, for use in mobile or rural settings. The performance of the detection module was demonstrated in three assays: a peptide, a protein and an antibody detection assay. The antibody detection assay with readout in the detection module proved to be 7-fold more sensitive that the traditional colorimetric plate-based ELISA. The protein and peptide assay showed a lower limit of detection (LLOD) of 200 fM and 460 fM respectively. Results demonstrate that the sensitivity of the immunoassays is comparable with lab-based immunoassays and at least equal or better than current mainstream POC devices. This sensitive readout holds the potential to develop POC tests, which are able to detect low concentrations of biomarkers. This will broaden the diagnostic capabilities at the clinician's office and at patient's home, where currently only the less sensitive lateral flow and dipstick POC tests are implemented.


Assuntos
Anticorpos/isolamento & purificação , Técnicas Biossensoriais , Técnicas Analíticas Microfluídicas/métodos , Peptídeos/isolamento & purificação , Proteínas/isolamento & purificação , Anticorpos/química , Bioensaio , Colorimetria/métodos , Humanos , Metais/química , Técnicas Analíticas Microfluídicas/instrumentação , Óxidos/química , Peptídeos/química , Testes Imediatos , Proteínas/química , Semicondutores
2.
Analyst ; 135(9): 2377-85, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20668755

RESUMO

We present an optimized procedure for freeze-drying and storing reagents for multiplex PCR followed by genotyping using a tag-array minisequencing assay with four color fluorescence detection which is suitable for microfluidic assay formats. A test panel was established for five cancer mutations in three codons (175, 248 and 273) of the tumor protein gene (TP53) and for 13 common single nucleotide polymorphisms (SNPs) in the TP53 gene. The activity of DNA polymerase was preserved for six months of storage after freeze-drying, and the half-life of activities of exonuclease I and shrimp alkaline phosphatase were estimated to 55 and 200 days, respectively. We conducted a systematic genotyping comparison using freeze-dried and liquid reagents. The accuracy of successful genotyping was 99.1% using freeze-dried reagents compared to liquid reagents. As a proof of concept, the genotyping protocol was carried out with freeze-dried reagents stored in reaction chambers fabricated by micromilling in a cyclic olefin copolymer substrate. The results reported in this study are a key step towards the development of an integrated microfluidic device for point-of-care DNA-based diagnostics.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Fosfatase Alcalina/metabolismo , Exodesoxirribonucleases/metabolismo , Corantes Fluorescentes/química , Liofilização , Genótipo , Análise de Sequência com Séries de Oligonucleotídeos , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase , Polimorfismo de Nucleotídeo Único , Fatores de Tempo , Proteína Supressora de Tumor p53/genética
3.
Biomed Microdevices ; 12(4): 673-81, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20336488

RESUMO

This report presents and describes a simple and scalable method for producing functional DNA microarrays within enclosed polymeric, PMMA, microfluidic devices. Brief (30 s) exposure to UV simultaneously immobilized poly(T)poly(C)-tagged DNA probes to the surface of unmodified PMMA and activated the surface for bonding below the glass transition temperature of the bulk PMMA. Functionality and validation of the enclosed PMMA microarrays was demonstrated as 18 patients were correctly genotyped for all eight mutation sites in the HBB gene interrogated. The fabrication process therefore produced probes with desired hybridization properties and sufficient bonding between PMMA layers to allow construction of microfluidic devices. The streamlined fabrication method is suited to the production of low-cost microfluidic microarray-based diagnostic devices and, as such, is equally applicable to the development of diagnostics for both resource rich and resource limited settings.


Assuntos
DNA/química , DNA/genética , Técnicas Analíticas Microfluídicas , Microtecnologia/métodos , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Polimetil Metacrilato , Raios Ultravioleta , Genótipo , Humanos , Desnaturação de Ácido Nucleico , Polimetil Metacrilato/química , Temperatura de Transição
4.
Lab Chip ; 6(3): 329-44, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16511615

RESUMO

This review offers an overview of the relatively young research area of continuous flow lab-on-a-chip for synthetic applications. A short introduction on the basic aspects of lab-on-a-chip is given in the first part. Subsequently, the effects of downscaling reaction vessels as well as the advantages of the continuous flow microfluidic approach over conventional chemical laboratory batch methodologies are illustrated by a number of examples of organic reactions carried out in microfluidic devices. The last part deals with a key issue of the lab-on-a-chip approach, viz. the integration of the microreactor with the analytical instrumentation to achieve high-throughput reaction monitoring.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Desenho de Equipamento , Estrutura Molecular , Compostos Orgânicos/síntese química , Compostos Orgânicos/química , Compostos Organometálicos/síntese química , Compostos Organometálicos/química , Sensibilidade e Especificidade
5.
Anal Chem ; 77(21): 6852-6, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16255582

RESUMO

The reaction of propyl isocyanate (2), benzyl isocyanate (3), and toluene-2,4-diisocyanate (4) with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (1) to yield the corresponding urea derivatives 5 was carried out in a continuous flow glass microfluidics chip. Real-time monitoring of the derivatization reactions was done by electrospray ionization mass spectrometry, making use of a recently reported modular chip-MS interface. Rate constants of 1.5 x 10(4), 5.2 x 10(4), and 2.4 x 10(4) M(-1) min(-1) were determined for 2, 3, and 4, respectively. Using macroscale batch conditions, the rate constants are 3-4 times lower. The faster on-chip kinetics is attributed to the more efficient molecular diffusion in the micrometer-sized channel.

6.
Lab Chip ; 5(10): 1111-22, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16175268

RESUMO

Two simple interfaces were designed and realized, enabling on-line coupling of microfluidics reactor chips to a nanoflow electrospray ionization (NESI) time-of-flight (TOF) mass spectrometer (MS). The interfaces are based on two different approaches: a monolithically integrated design, in which ionization is assisted by on-chip gas nebulization, and a modular approach implying the use of commercially available Picospray tips. Using reserpine as a reference compound in a 1ratio1 mixture of acetonitrile and water revealed that both interfaces provide a remarkably stable mass spectrometric signal (standard deviations lower than 8% and 1% for the monolithic and modular approaches, respectively). Glass microreactors, containing mixing zones, were fabricated and coupled to the modular interface with perfluoroelastomer Nanoport fluidics connectors, providing a tool to study chemical reactions on-line. Investigation of the mixing dynamics showed that complete on-chip reagents mixing is achieved within a few tens of milliseconds. Metal-ligand interactions of Zn-porphyrin with pyridine (2), 4-ethylpyridine (3), 4-phenylpyridine (4), N-methylimidazole (5), and N-butylimidazole (6) in acetonitrile as well as host-guest complexations of beta-cyclodextrin (7) with N-(1-adamantyl)acetamide (8) or 4-tert-butylacetanilide (9) in water were studied by mass spectrometry using the modular NESI-chip interface. From on-chip dilution-based mass spectrometric titrations of Zn-porphyrin 1 with pyridine (2) or 4-phenylpyridine (4) in acetonitrile Ka-values of 4.6 +/- 0.4 x 10(3) M(-1) and 6.5 +/- 1.2 x 10(3) M(-1), respectively, were calculated. The Ka-values are about four times larger than those obtained with UV/vis spectroscopy in solution, probably due to a higher ionization efficiency of complexed compared to uncomplexed Zn-porphyrin. For the complexation of N-(1-adamantyl)acetamide (8) with beta-cyclodextrin (7), a Ka-value of 3.6 +/- 0.3 x 10(4) M(-1) was obtained, which is in good agreement with that determined by microcalorimetry.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Análise Serial de Proteínas/métodos , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Acetanilidas/química , Acetonitrilas/química , Amantadina/química , Calorimetria , Eletroforese Capilar/métodos , Eletroforese em Microchip/métodos , Gases , Imidazóis/química , Íons , Cinética , Ligantes , Espectrometria de Massas , Metais/química , Microscopia de Fluorescência , Modelos Químicos , Nanotecnologia , Porfirinas/química , Piridinas/química , Reserpina/farmacologia , Software , Fatores de Tempo , Água/química , Zinco/química , beta-Ciclodextrinas/química
7.
Lab Chip ; 5(4): 378-81, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15791334

RESUMO

The integration of a monitoring port along the microfluidic path of a MALDI-chip integrated device is described. Optimization of the microreactor design allows longer reaction and measuring times. The Schiff base reaction between 4-tert-butylaniline (1) and 4-tert-butylbenzaldehyde (2) in ethanol was carried out on-chip in the MALDI ionization chamber and the formed imine 3 was detected in real time, demonstrating the feasibility of the "monitoring window" approach. This preliminary result opens the way to on-chip kinetic studies by MALDI-MS, by opening multiple monitoring windows along the microchannel.


Assuntos
Dispositivos Lab-On-A-Chip , Microfluídica/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Compostos de Anilina/química , Benzaldeídos/química , Estudos de Viabilidade , Iminas/análise , Iminas/síntese química , Procedimentos Analíticos em Microchip/métodos , Microfluídica/métodos , Estrutura Molecular , Bases de Schiff/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Propriedades de Superfície
8.
Chem Commun (Camb) ; (15): 1924-5, 2003 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-12932035

RESUMO

Surface phenomena are an important contribution to the "chip effect", leading to higher yields and shorter reaction times, as demonstrated for the acid-catalysed esterification of 9-pyrenebutyric acid within a glass fabricated micro reactor.

9.
Anal Chem ; 74(16): 3972-6, 2002 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-12199562

RESUMO

A continuous flow micro total analysis system (micro-TAS) consisting of an on-chip microfluidic device connected to a matrix assisted laser desorption ionization [MALDI] time-of-flight [TOF] mass spectrometer (MS) as an analytical screening system is presented. Reaction microchannels and inlet/outlet reservoirs were fabricated by powderblasting on glass wafers that were then bonded to silicon substrates. The novel lab-on-a-chip was realized by integrating the microdevice with a MALDI-TOFMS standard sample plate used as carrier to get the microfluidic device in the MALDI instrument. A novel pressure-driven pumping mechanism using the vacuum of the instrument as a driving force induces flow in the reaction microchannel in a self-activating way. Organic syntheses as well as biochemical reactions are carried out entirely inside the MALDI-MS ionization vacuum chamber and analyzed on-line by MALDI-TOFMS in real time. The effectiveness of the micro-TAS system has been successfully demonstrated with several examples of (bio)chemical reactions.


Assuntos
Microquímica/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Sequência de Aminoácidos , Sequência de Bases , Microquímica/métodos , Oligonucleotídeos/análise , Sistemas On-Line , Peptídeos/análise , Análise de Sequência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA