1.
Front Bioeng Biotechnol ; 12: 1340653, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39170061

RESUMO

Cell-based therapies represent the current frontier of biomedical innovations, with the technologies required underpinning treatments as broad as CAR-T cell therapies, stem cell treatments, genetic therapies and mRNA manufacture. A key bottleneck in the manufacturing process for each of these lies in the expansion of cells within a bioreactor vessel, requiring by far the greatest share of time for what are often time-critical therapies. While various designs, culture feeding and mixing methods are employed in these bioreactors, a common concern among manufacturers and researchers lies in whether shear stresses generated by culture media flow will damage cells and inhibit expansion. This study develops an analytical tool to link macro-scale measures of flow to risk of cell death using relationships with eddy size and dissipation rates, from eddies generated off flat surfaces. This analytical tool was then employed using computational fluid dynamics (CFD) to replicate a range of generic bioreactor geometries and flow conditions. We found that no combination of flow condition or design parameter was predicted by the tool to cause cell death within eddies, indicating negligible risk of cell death due to eddy formation within cell culture systems. While this requires experimental validation, and does not apply when cells are expanded using microcarriers, this tool nonetheless provides reassurance and accessible prediction of bioreactor design parameters that could result in cell death. Finally, our findings show that bioreactor design can be tailored such that the shear stress stimulation of cells can be selectively altered through small changes in flow rate.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38763978

RESUMO

Haemarthrosis is an inherent clinical feature of haemophilia, a disease characterised by an absence or reduction in clotting proteins. Patients with severe haemophilia experience joint bleeding leading to blood-induced ankle arthropathy (haemarthropathy). Altered biomechanics of the ankle have been reported in people with haemophilia; however, the consequence of this on joint health is little understood. The aim of this study was to assess the changes in joint contact due to haemophilia disease-specific gait features using patient-specific modelling, to better understand the link between biomechanics and joint outcomes. Four, image-based, finite element models of haemophilic ankles were simulated through consecutive events in the stance phase of gait, using both patient-specific and healthy control group (n = 36) biomechanical inputs. One healthy control FE model was simulated through the healthy control stance phase of the gait cycle for a point of comparison. The method developed allowed cartilage contact mechanics to be assessed throughout the loading phase of the gait cycle. This showed areas of increased contact pressure in the medial and lateral regions of the talar dome, which may be linked to collapse in these regions. This method may allow the relationship between structure and function in the tibiotalar joint to be better understood.

3.
J Mech Behav Biomed Mater ; 150: 106279, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38007990

RESUMO

Diabetic foot ulceration is linked to high amputation and mortality rates, with the substantial associated annual spend on the at-risk diabetic foot reflecting the intensive time and labour involved in treatment. Assessing plantar interactions and developing improved understanding of the formation pathways of diabetic ulceration is important to orthotic interventions and patient outcomes. Plantar skin surrogates which emulate the mechanical and tribological characteristics can help improve physical models of ulceration, reduce reliance on cadaveric use and inform more complex computational modelling approaches. The information available from existing studies to characterise plantar skin is limited, typically featuring ex-vivo representations of skin and subcutaneous tissue combined and given focus to shear studies with time dependency. The aim of this study is to improve understanding of plantar tissue mechanics by assessing the mechanical characteristics of plantar skin in two groups; (1) non-diabetic and (2) diabetic donors without the subcutaneous tissue attachment of previous work in this field. Digital image correlation was used to assess inherent skin pre-tension of the plantar rearfoot prior to dissection. Young's modulus, storage and loss moduli were tested for using tensile stress-strain failure analysis and tensile and compressive dynamic mechanical analysis, which was conducted on excised plantar rearfoot donor specimens for both disease state cohorts at frequencies reflecting those achieved in activities of daily living. Plantar skin thickness for donor specimens were comparable to values obtained using ultrasound acquired in vivo values. Median tensile storage and loss moduli, along with Young's modulus, was higher in the diabetic cohort. With a mean Young's modulus of 0.83 ± 0.49 MPa and 1.33 ± 0.43 MPa for non-diabetic and diabetic specimens respectively. Compressive studies showed consistency between cohorts for median storage and loss moduli. The outcomes from this study show mechanical characteristics of plantar skin without the involvement of subcuteanous tissues under reflective daily achieved loading regimes, showing differences in the non-diabetic and diabetic specimens trialled to support improved understanding of plantar tissue response under tribological interactions.


Assuntos
Diabetes Mellitus , Pé Diabético , Humanos , Atividades Cotidianas , Pele , Tela Subcutânea , Módulo de Elasticidade
4.
Front Bioeng Biotechnol ; 11: 1187710, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37662427

RESUMO

Introduction: Under plantar loading regimes, it is accepted that both pressure and shear strain biomechanically contribute to formation and deterioration of diabetic foot ulceration (DFU). Plantar foot strain characteristics in the at-risk diabetic foot are little researched due to lack of measurement devices. Plantar pressure comparatively, is widely quantified and used in the characterisation of diabetic foot ulceration risk, with a range of clinically implemented pressure measurement devices on the market. With the development of novel strain quantification methods in its infancy, feasibility testing and validation of these measurement devices for use is required. Initial studies centre on normal walking speed, reflecting common activities of daily living, but evaluating response to differing gait loading regimes is needed to support the use of such technologies for potential clinical translation. This study evaluates the effects of speed and inclination on stance time, strain location and strain response using a low-cost novel strain measurement insole. Methods: The STrain Analysis and Mapping of the Plantar Aspect (STAMPS) insole has been developed, and feasibility tested under self-selected normal walking speeds to characterise plantar foot strain, with testing beyond this limited regime required. A treadmill was implemented to standardise speed and inclination for a range of daily plantar loading conditions. A small cohort, comprising of five non-diabetic participants, were examined at slow (0.75 m/s), normal (1.25 m/s) and brisk (2 m/s) walking speeds and normal speed at inclination (10% gradient). Results: Plantar strain active regions were seen to increase with increasing speed across all participants. With inclination, it was seen that strain active regions reduce in the hindfoot and show a tendency to forefoot with discretionary changes to strain seen. Stance time decreases with increasing speed, as expected, with reduced stance time with inclination. Discussion: Comparison of the strain response and stance time should be considered when evaluating foot biomechanics in diabetic populations to assess strain time interval effects. This study supports the evaluation of the STAMPS insole to successfully track strain changes under differing plantar loading conditions and warrants further investigation of healthy and diabetic cohorts to assess the implications for use as a risk assessment tool for DFU.

5.
Acta Biomater ; 159: 410-422, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36736850

RESUMO

Aseptic loosening and osteolysis continue to be a short- to mid-term problem for total ankle replacement (TAR) devices. The production of wear particles may contribute to poor performance, but their characteristics are not well understood. This study aimed to determine the chemical composition, size and morphology of wear particles surrounding failed TARs. A recently developed wear particle isolation method capable of isolating both high- and low-density materials was applied to 20 retrieved periprosthetic tissue samples from 15 failed TARs of three different brands. Isolated particles were imaged using ultra-high-resolution imaging and characterised manually to determine their chemical composition, size, and morphology. Six different materials were identified, which included: UHMWPE, calcium phosphate (CaP), cobalt chromium alloy (CoCr), commercially pure titanium, titanium alloy and stainless steel. Eighteen of the 20 samples contained three or more different wear particle material types. In addition to sub-micron UHMWPE particles, which were present in all samples, elongated micron-sized shards of CaP and flakes of CoCr were commonly isolated from tissues surrounding AES TARs. The mixed particles identified in this study demonstrate the existence of a complex periprosthetic environment surrounding TAR devices. The presence of such particles suggests that early failure of devices may be due in part to the multifaceted biological cascade that ensues after particle release. This study could be used to support the validation of clinically-relevant wear simulator testing, pre-clinical assessment of fixation wear and biological response studies to improve the performance of next generation ankle replacement devices. STATEMENT OF SIGNIFICANCE: Total ankle replacement devices do not perform as well as total hip and knee replacements, which is in part due to the relatively poor scientific understanding of how they fail. The excessive production of certain types of wear debris is known to contribute to joint replacement failure. This is the first study to successfully isolate and characterise high- and low-density wear particles from tissues collected from patients with a failed total ankle replacement. This article includes the chemical composition and characteristics of the wear debris generated by ankle devices, all of which may affect their performance. This research provides clinically relevant reference values and images to support the development of pre-clinical testing for future total ankle replacement designs.


Assuntos
Artroplastia de Substituição do Tornozelo , Prótese de Quadril , Humanos , Titânio , Polietilenos , Ligas , Falha de Prótese , Tamanho da Partícula
6.
J Mech Behav Biomed Mater ; 139: 105671, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36682172

RESUMO

Decellularised porcine superflexor tendon (pSFT) has been characterised as a suitable scaffold for anterior cruciate ligament replacement, with dimensions similar to hamstring tendon autograft. However, decellularisation of tissues may reduce or damage extracellular matrix components, leading to undesirable biomechanical changes at a whole tissue scale. Although the role of collagen in tendons is well established, the mechanical contribution of glycosaminoglycans (GAGs) is less evident and could be altered by the decellularisation process. In this study, the contribution of GAGs to the tensile and compressive mechanical properties of pSFT was determined and whether decellularisation affected these properties by reducing GAG content or functionality. PSFTs were either enzymatically treated using chondroitinase ABC to remove GAGs or decellularised using previously established methods. Native, GAG-depleted and decellularised pSFT groups were then subjected to quantitative assays and biomechanical characterisation. In tension, specimens underwent stress relaxation and strength testing. In compression, specimens underwent confined compression testing. The GAG-depleted group was found to have circa 86% reduction of GAG content compared to native and decellularised groups. There was no significant difference in GAG content between native (3.75 ± 0.58 µg/mg) and decellularised (3.40 ± 0.37 µg/mg) groups. Stress relaxation testing discovered the time-independent and time-dependent relaxation moduli of the decellularised group were reduced ≥50% compared to native and GAG-depleted groups. However, viscoelastic behaviour of native and GAG-depleted groups resulted similar. Strength testing discovered no differences between native and GAG-depleted group's properties, albeit a reduction ∼20% for decellularised specimens' linear modulus and tensile strength compared to native tissue. In compression testing, the aggregate modulus was found to be circa 74% lower in the GAG-depleted group than the native and decellularised groups, while the zero-strain permeability was significantly higher in the GAG-depleted group (0.86 ± 0.65 mm4/N) than the decellularised group (0.03 ± 0.04 mm4/N). The results indicate that GAGs may significantly contribute to the mechanical properties of pSFT in compression, but not in tension. Furthermore, the content and function of GAGs in pSFTs are unaffected by decellularisation and the mechanical properties of the tissue remain comparable to native tissue.


Assuntos
Glicosaminoglicanos , Tendões , Animais , Suínos , Ligamento Cruzado Anterior , Colágeno , Fenômenos Físicos , Fenômenos Biomecânicos
7.
J Foot Ankle Res ; 15(1): 88, 2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36503504

RESUMO

BACKGROUND: End-stage ankle osteoarthritis typically causes severe pain and impaired function. Surgical treatment involves total ankle replacement (TAR) or ankle fusion. Definitive evidence about which procedure is optimal is lacking. No previous studies have thoroughly explored patients' experiences across the entire TAR/ankle fusion pathway. This study aimed to address this gap by exploring perceptions of surgery, education, rehabilitation and outcomes among patients who had undergone TAR or ankle fusion. METHODS: Seven participants were purposively selected from an orthopaedic centre in northern England (3 females, 4 males). Participants had undergone primary TAR without revision (n = 2), TAR requiring revision (n = 3) or ankle fusion (n = 2). Each participant completed a single semi-structured interview. Interviews were digitally recorded, transcribed verbatim and analysed thematically. RESULTS: Three themes, each with two subthemes, were identified: decision-making (seeking help; surgical options), perceptions of support (information/education; clinical support) and impact on the individual (personal circumstances and beliefs; post-operative outcomes). Pain affecting participants' valued activities was key to their decision to seek help. Participants' decision between TAR and ankle fusion was influenced by multiple factors. Concerns regarding the lack of joint flexibility following fusion were highlighted, with some participants perceiving TAR as a "proper ankle" that would enable them to avoid limping. Participants obtained information from various sources, with most feeling that the education from their care team was inadequate. Participants' individual circumstances and beliefs influenced their decision-making and perceptions of their post-operative outcomes. Finally, whilst most participants were pleased with their outcomes, some experienced substantial ongoing problems such as difficulty walking and chronic pain. CONCLUSIONS: This study demonstrates the importance of providing adequate education about TAR and ankle fusion to enable patients to make informed decisions. Most participants felt that the education and clinical support they received did not fully meet their needs. Participants' personal circumstances and beliefs had a strong influence on their decision-making and perceptions of their post-operative outcomes, highlighting the need to personally tailor education and clinical support. Future work with a larger sample of patients and other key stakeholders is required to develop consensus-based guidelines on pre- and post-operative support for patients undergoing TAR/ankle fusion.


Assuntos
Artroplastia de Substituição do Tornozelo , Osteoartrite , Masculino , Feminino , Humanos , Artroplastia de Substituição do Tornozelo/métodos , Artrodese/métodos , Articulação do Tornozelo/cirurgia , Osteoartrite/cirurgia , Dor
8.
J Mech Behav Biomed Mater ; 136: 105482, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36209589

RESUMO

The increase in the global diabetic population is leading to an increase in associated complications such as diabetic foot ulceration (DFU), associated amputations, morbidity, which substantial treatment costs. Early identification of DFU risk is therefore of great benefit. International guidelines recommend off-loading is the most important intervention for healing and prevention of DFU, with current research focused on pressure measurement techniques. The contribution of strain to DFU formation is not well understood due to challenges in measurement. The limited data available in the literature suggest that plantar strain is involved in ulcer formation. As a consequence, there is a need for plantar strain measurement systems to advance understanding and inform clinical treatment. A method was developed to determine plantar strain based on a Digital Image Correlation (DIC) approach. A speckle pattern is applied to the plantar aspect of the foot using a low ink transference method. A raised walkway with transparent panels is combined with a calibrated camera to capture images of the plantar aspect throughout a single stance phase. Plantar strain is then determined using 2D DIC and custom analysis summarises these data into clinically relevant metrics. A feasibility study involving six healthy participants was used to assess the efficacy of this new technique. The feasibility study successfully captured plantar surface strain characteristics continuously throughout the stance phase for all participants. Peak mean and averaged mean strains varied in location between participants when mapped into anatomical regions of plantar interest, ranging from the calcaneus to the metatarsal heads and hallux. This method provides the ability to measure plantar skin strain for use in both research and clinical environments. It has the potential to inform improved understanding of the role of strain in DFU formation. Further studies using this technique can support these ambitions and help differentiate between healthy and abnormal plantar strain regimes.


Assuntos
Pé Diabético , Ossos do Metatarso , Humanos , , Pele , Fenômenos Biomecânicos
9.
Clin Biomech (Bristol, Avon) ; 99: 105745, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36063743

RESUMO

BACKGROUND: Subchondral bone cysts are a common presentation in ankle haemarthropathy. The relationship with ankle joint health has however not previously been investigated. The aim of this study was to assess the influence of subchondral bone cysts of differing shapes, volumes and depths on joint health. METHODS: Chronologically sequential Magnetic Resonance imaging scans of four hemophilic ankles with subchondral bone cysts present (N = 18) were used to build patient specific finite element models under two cystic conditions to assess their influence on cartilage contact pressures. Variables such as location, volume and depth were considered individually, to investigate whether certain cystic conditions may be more detrimental to cartilage health. FINDINGS: Significant quantifiable contact redistribution was seen in the presence of subchondral bone cysts and this redistribution reflected the shape and size of the cysts, however, with the presence of cysts in both bones in 10 of the 18 cases a direct relationship to volume could not be correlated. INTERPRETATION: This work demonstrated a redistribution of contact pressures in the presence of subchondral bone cysts. This alteration to loading history could be linked to cartilage degeneration due to the biological response to abnormal loading.


Assuntos
Cistos Ósseos , Doenças das Cartilagens , Cartilagem Articular , Cistos Ósseos/diagnóstico por imagem , Osso e Ossos , Cartilagem/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Análise de Elementos Finitos , Humanos
10.
J Biomed Mater Res B Appl Biomater ; 110(10): 2276-2289, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35532138

RESUMO

Submicron-sized wear particles are generally accepted as a potential cause of aseptic loosening when produced in sufficient volumes. With the accelerating use of increasingly wear-resistant biomaterials, identifying such particles and evaluating their biological response is becoming more challenging. Highly sensitive wear particle isolation methods have been developed but these methods cannot isolate the complete spectrum of particle types present in individual tissue samples. Two established techniques were modified to create one novel method to isolate both high- and low-density materials from periprosthetic tissue samples. Ten total hip replacement and eight total knee replacement tissue samples were processed. All particle types were characterized using high resolution scanning electron microscopy. UHMWPE and a range of high-density materials were isolated from all tissue samples, including: polymethylmethacrylate, zirconium dioxide, titanium alloy, cobalt chromium alloy and stainless steel. This feasibility study demonstrates the coexistence of mixed particle types in periprosthetic tissues and provides researchers with high-resolution images of clinically relevant wear particles that could be used as a reference for future in vitro biological response studies.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese de Quadril , Ligas , Humanos , Tamanho da Partícula , Polietilenos , Falha de Prótese , Titânio
11.
Clin Anat ; 34(6): 941-947, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33998061

RESUMO

Flattening of the trochlear tali is clinically observed as structural and functional changes advance in patients with hemarthropathy of the ankle. However, the degree of this flattening has not yet been quantified, and distribution of the morphological changes across the talus not yet defined. Chronologically sequential MR images of both a hemophilic patient group (N = 5) and a single scan from a nondiseased, sex-matched, control group (N = 11) were used to take four measurements of the trochlear talus morphology at three locations (medial, central and lateral) along the sagittal plane. Three ratios of interest were defined from these to assess whether the talar dome flattens with disease. The control group MRI measurements were validated against literature data obtained from CT scans or planar X-Rays. The influence of disease on talar morphology was assessed by direct comparison of the hemophilic cases with the control group. The values for all three ratios, in all locations, differed between the control and the hemophilic group. Flattening was indicated in the hemophilic group in the medial and lateral talus, but differences in the central talus were not statistically significant. This work demonstrates that morphological assessment of the talus from MR images is similar to that from CT scans or planar X-Rays. Talar flattening does occur with hemarthropathy, especially at the medial and lateral edges of the joint surface. General flattening of the trochlear talus was confirmed in this small patient sample, however the degree and rate of change is unique to each ankle.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/patologia , Hemofilia A/complicações , Tálus/diagnóstico por imagem , Tálus/patologia , Adolescente , Adulto , Criança , Diagnóstico por Imagem , Humanos , Adulto Jovem
12.
Regen Med ; 2018 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-29553890

RESUMO

The ankle degeneration ranging from focal osteochondral lesions to osteoarthritis can cause a total joint function loss. With rising life expectancy and activity of the patients, various regenerative therapies were introduced aiming to preserve the joint function via the induction of cartilage and bone repair. Here, biological events and mechanical changes of the ankle degeneration were discussed. The regenerative therapies were reviewed versus the standard surgical treatment. We especially focused on the use of mesenchymal (multipotential) stromal cells (MSCs) highlighting their dual functions of regeneration and cell modulation with an emphasis on the emerging MSC-based clinical studies. Being at an early step, more basic and clinical research is needed to optimize the applications of all ankle regenerative therapies including MSC-based methods.

13.
Proc Inst Mech Eng H ; 232(2): 127-134, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29251167

RESUMO

Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection.


Assuntos
Artroplastia do Joelho , Fenômenos Mecânicos , Polietileno , Desenho de Prótese , Falha de Prótese
14.
Wear ; 374-375: 86-91, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-28316350

RESUMO

New bearing materials for total joint replacement have been explored as the need to improve longevity and enhance performance is driven by the changing demands of the patient demographic. Carbon-reinforced PEEK has demonstrated good wear characteristics in experimental wear simulation in both simple geometry pin-on-plate studies and in total hip joint replacement. Carbon reinforced PEEK CFR-PEEK has the potential to reduce tibial insert thickness and preserve bone in the knee. This study investigated the wear performance of PEEK and CFR-PEEK in a low conformity total knee replacement configuration. Custom-made flat inserts were tested against cobalt-chromium femoral bearings in a knee wear simulation for a period of three million cycles. Wear was assessed gravimetrically at intervals throughout the study. The wear rates of both PEEK and CFR-PEEK were very high and almost two orders of magnitude higher than the wear rate of UHMWPE under comparable conditions. Evidence of mechanical failure of the materials, including surface cracking and delamination was observed in both materials. This study highlights that these materials may not be suitable alternatives for UHMWPE in low-conformity designs.

15.
Orthop Trauma ; 30(3): 232-238, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27594929

RESUMO

This paper provides an introduction to the biomechanics of the ankle, introducing the bony anatomy involved in motion of the foot and ankle. The complexity of the ankle anatomy has a significant influence on the biomechanical performance of the joint, and this paper discusses the motions of the ankle joint complex, and the joints at which it is proposed they occur. It provides insight into the ligaments that are critical to the stability and function of the ankle joint. It describes the movements involved in a normal gait cycle, and also highlights how these may change as a result of surgical intervention such as total joint replacement or fusion.

16.
Clin Orthop Relat Res ; 474(11): 2394-2404, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27432420

RESUMO

BACKGROUND: Polyetheretherketone (PEEK) and its composites are polymers resistant to fatigue strain, radiologically transparent, and have mechanical properties suitable for a range of orthopaedic applications. In bulk form, PEEK composites are generally accepted as biocompatible. In particulate form, however, the biologic response relevant to joint replacement devices remains unclear. The biologic response to wear particles affects the longevity of total joint arthroplasties. Particles in the phagocytozable size range of 0.1 µm to 10 µm are considered the most biologically reactive, particularly particles with a mean size of < 1 µm. This systematic review aimed to identify the current evidence for the biologic response to PEEK-based wear debris from total joint arthroplasties. QUESTIONS/PURPOSES: (1) What are the quantitative characteristics of PEEK-based wear particles produced by total joint arthroplasties? (2) Do PEEK wear particles cause an adverse biologic response when compared with UHMWPE or a similar negative control biomaterial? (3) Is the biologic response affected by particle characteristics? METHODS: Embase and Ovid Medline databases were searched for studies that quantified PEEK-based particle characteristics and/or investigated the biologic response to PEEK-based particles relevant to total joint arthroplasties. The keyword search included brands of PEEK (eg, MITCH, MOTIS) or variations of PEEK types and nomenclature (eg, PAEK, CFR-PEEK) in combination with types of joint (eg, hip, knee) and synonyms for wear debris or immunologic response (eg, particles, cytotoxicity). Peer-reviewed studies, published in English, investigating total joint arthroplasty devices and cytotoxic effects of PEEK particulates were included. Studies investigating devices without articulating bearings (eg, spinal instrumentation devices) and bulk material or contact cytotoxicity were excluded. Of 129 studies, 15 were selected for analysis and interpretation. No studies were found that isolated and characterized PEEK wear particles from retrieved periprosthetic human tissue samples. RESULTS: In the four studies that quantified PEEK-based particles produced using hip, knee, and spinal joint replacement simulators, the mean particle size was 0.23 µm to 2.0 µm. The absolute range reported was approximately 0.01 µm to 50 µm. Rod-like carbon particulates and granular-shaped PEEK particles were identified in human tissue by histologic analysis. Ten studies, including six animal models (rat, mouse, and rabbit), three cell line experiments, and two human tissue retreival studies, investigated the biologic response to PEEK-based particles. Qualitative histologic assessments showed immunologic cell infiltration to be similar for PEEK particles when compared with UHMWPE particles in all six of the animal studies identified. However, increased inflammatory cytokine release (such as tumor necrosis factor-α) was identified in only one in vitro study, but without substantial suppression in macrophage viability. Only one study tested the effects of particle size on cytotoxicity and found the largest unfilled PEEK particles (approximately 13 µm) to have a toxic effect; UHMWPE particles in the same size range showed a similar cytotoxic effect. CONCLUSIONS: Wear particles produced by PEEK-based bearings were, in almost all cases, in the phagocytozable size range (0.1-10 µm). The studies that evaluated the biologic response to PEEK-based particles generally found cytotoxicity to be within acceptable limits relative to the UHMWPE control, but inconsistent when inflammatory cytokine release was considered. CLINICAL RELEVANCE: To translate new and advanced materials into clinical use more quickly, the clinical relevance and validity of preclinical tests need to be improved. To achieve this for PEEK-based devices, human tissue retrieval studies including subsequent particle isolation and characterization analyses are required. In vitro cell studies using isolated wear particles from tissue or validated joint replacement simulators, instead of manufactured particles, are also required.


Assuntos
Artroplastia de Substituição/efeitos adversos , Artroplastia de Substituição/instrumentação , Reação a Corpo Estranho/etiologia , Prótese Articular/efeitos adversos , Cetonas/efeitos adversos , Polietilenoglicóis/efeitos adversos , Animais , Benzofenonas , Citocinas/imunologia , Citocinas/metabolismo , Reação a Corpo Estranho/imunologia , Reação a Corpo Estranho/metabolismo , Humanos , Mediadores da Inflamação/imunologia , Mediadores da Inflamação/metabolismo , Cetonas/química , Tamanho da Partícula , Fagocitose , Polietilenoglicóis/química , Polietilenos/efeitos adversos , Polímeros , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Estresse Mecânico , Resultado do Tratamento
17.
Proc Inst Mech Eng H ; 230(5): 429-39, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27160561

RESUMO

Advancements in knee replacement design, material and sterilisation processes have provided improved clinical results. However, surface wear of the polyethylene leading to osteolysis is still considered the longer-term risk factor. Experimental wear simulation is an established method for evaluating the wear performance of total joint replacements. The aim of this study was to investigate the influence of simulation input conditions, specifically input kinematic magnitudes, waveforms and directions of motion and position of the femoral centre of rotation, on the wear performance of a fixed-bearing total knee replacement through a combined experimental and computational approach. Studies were completed using conventional and moderately cross-linked polyethylene to determine whether the influence of these simulation input conditions varied with material. The position of the femoral centre of rotation and the input kinematics were shown to have a significant influence on the wear rates. Similar trends were shown for both the conventional and moderately cross-linked polyethylene materials, although lower wear rates were found for the moderately cross-linked polyethylene due to the higher level of cross-linking. The most important factor influencing the wear was the position of the relative contact point at the femoral component and tibial insert interface. This was dependent on the combination of input displacement magnitudes, waveforms, direction of motion and femoral centre of rotation. This study provides further evidence that in order to study variables such as design and material in total knee replacement, it is important to carefully control knee simulation conditions. This can be more effectively achieved through the use of displacement control simulation.


Assuntos
Artroplastia do Joelho/instrumentação , Simulação por Computador , Análise de Falha de Equipamento/métodos , Prótese do Joelho , Fenômenos Biomecânicos , Fricção , Humanos , Modelos Biológicos
18.
Proc Inst Mech Eng H ; 228(1): 98-106, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24297773

RESUMO

The mean average life is increasing; therefore, there is a need to increase the lifetime of the prostheses. To fulfil this requirement, new prosthetic designs and materials are being introduced. Two of the design parameters that may affect wear of total knee replacements, and hence the expected lifetime, are the insert conformity and material. Computational models have been used extensively for wear prediction and optimisation of artificial knee designs. The objective of the present study was to use a previously validated non-dimensional wear coefficient-based computational wear model to investigate the effect of insert conformity and material on the predicted wear in total knee replacements. Four different inserts (curved, lipped, partial flat and custom flat), with different conformity levels, were tested against the same femoral and under two different kinematic inputs (intermediate and high), with different levels of cross-shear. The insert bearing materials were either conventional or moderately cross-linked ultra-high molecular weight polyethylene (UHMWPE). Wear predictions were validated against the experimental data from Leeds knee simulation tests. The predicted wear rates for the curved insert (most conformed) were more than three times those for the flat insert (least conformed). In addition, the computationally predicted average volumetric wear rates for moderately cross-linked UHMWPE bearings were less than half of their corresponding conventional UHMWPE bearings. Moreover, the wear of the moderately cross-linked UHMWPE was shown to be less dependent on the degree of cross-shear, compared to conventional UHMWPE. These results along with supporting experimental studies provide insight into the design variables, which may reduce wear in knee replacements.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Teste de Materiais , Desenho de Prótese , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Modelos Biológicos , Polietilenos
19.
Proc Inst Mech Eng H ; 227(1): 18-26, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23516952

RESUMO

Polyethylene wear is a great concern in total joint replacement. It is now considered a major limiting factor to the long life of such prostheses. Cross-linking has been introduced to reduce the wear of ultra-high-molecular-weight polyethylene (UHMWPE). Computational models have been used extensively for wear prediction and optimization of artificial knee designs. However, in order to be independent and have general applicability and predictability, computational wear models should be based on inputs from independent experimentally determined wear parameters (wear factors or wear coefficients). The objective of this study was to investigate moderately cross-linked UHMWPE, using a multidirectional pin-on-plate wear test machine, under a wide range of applied nominal contact pressure (from 1 to 11 MPa) and under five different kinematic inputs, varying from a purely linear track to a maximum rotation of +/- 55 degrees. A computational model, based on a direct simulation of the multidirectional pin-on-plate wear tester, was developed to quantify the degree of cross-shear (CS) of the polyethylene pins articulating against the metallic plates. The moderately cross-linked UHMWPE showed wear factors less than half of that reported in the literature for, the conventional UHMWPE, under the same loading and kinematic inputs. In addition, under high applied nominal contact stress, the moderately crosslinked UHMWPE wear showed lower dependence on the degree of CS compared to that under low applied nominal contact stress. The calculated wear coefficients were found to be independent of the applied nominal contact stress, in contrast to the wear factors that were shown to be highly pressure dependent. This study provided independent wear data for inputs into computational models for moderately cross-linked polyethylene and supported the application of wear coefficient-based computational wear models.


Assuntos
Materiais Biocompatíveis/química , Reagentes de Ligações Cruzadas/química , Polietilenos/química , Módulo de Elasticidade , Fricção , Dureza , Testes de Dureza , Humanos , Teste de Materiais , Pressão , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície
20.
Proc Inst Mech Eng H ; 227(2): 175-80, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23513988

RESUMO

Preparation of the proximal femur using incremental broaches to create the ideal cancellous bone envelope is an important technique to perfect in uncemented hip arthroplasty. To guide broaching adequacy and final implant position, the surgeon can use audible pitch changes produced by the femoral broach and definitive implant. The aim of this study was to characterise these pitch changes by analysing the sound spectra created by the first broach, last broach and implant using spectral analysis software. The last broach and implant introduction spectra demonstrated low-frequency (400-1200 Hz) spectral peaks that were not detected when using the first broach. These frequencies corresponded to the natural resonant frequency of a standing sound wave within the femoral bone canal (approximately 894 Hz) that was estimated using acoustic physics theory. The remaining spectral peaks were associated with transverse vibration modes produced by striking the metal broach handle and implant introducer and were a function of the constructs geometry and material properties.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/fisiopatologia , Fêmur/cirurgia , Prótese de Quadril , Osteotomia/métodos , Espectrografia do Som/métodos , Cirurgia Assistida por Computador/métodos , Artroplastia de Quadril/instrumentação , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade