Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 58(2): 373-80, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17654579

RESUMO

A new technique is demonstrated in six healthy human subjects that combines grid-tagging and hyperpolarized helium-3 MRI to assess regional lung biomechanical function and quantitative ventilation. 2D grid-tagging, achieved by applying sinc-modulated RF-pulse trains along the frequency- and phase-encoding directions, was followed by a multislice fast low-angle shot (FLASH)-based acquisition at inspiration and expiration. The displacement vectors, first and second principal strains, and quantitative ventilation were computed, and mean values were calculated for the upper, middle, and lower lung regions. Displacements in the lower region were significantly greater than those in either the middle or upper region (P < 0.005), while there were no significant differences between the three regions for the two principal strains and quantitative ventilation (P = 0.11-0.92). Variations in principal strains and ventilation were greater between subjects than between lung zones within individual subjects. This technique has the potential to provide insight into regional biomechanical alterations of lung function in a variety of lung diseases.


Assuntos
Hélio , Imageamento por Ressonância Magnética/métodos , Ventilação Pulmonar/fisiologia , Adulto , Algoritmos , Fenômenos Biomecânicos , Feminino , Humanos , Isótopos , Masculino , Testes de Função Respiratória , Mecânica Respiratória
2.
MAGMA ; 16(5): 218-26, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15108030

RESUMO

The signal-to-noise ratio (SNR) of hyperpolarized noble gas MR images is sensitive to the flip angle used. Variations in flip angle due to B1-inhomogeneity of the RF coil cause intensity variation artifacts in lung ventilation images which may mask or mimic disease. We show these artifacts can be minimized by using the optimal flip angle and corrected if the local flip angle is known. Hyperpolarized 3He lung images were obtained in ten healthy subjects using both a conventional gradient-echo sequence and a new hybrid pulse sequence designed to simultaneously acquire lung ventilation images and corresponding flip-angle maps in comparable imaging time. Flip-angle maps and corrected images were calculated from the hybrid scan and compared with conventional images. The qualitative theoretical dependence of flip angle on SNR was verified. Ventilation images and flip-angle maps were successfully obtained with the hybrid sequence. Corrections to image intensity calculated from the flip-angle maps appeared reasonable for images acquired using an average flip angle near optimal. Use of the optimal flip angle is crucial to the quality of lung ventilation images. Artifactual intensity variations due to RF-coil inhomogeneity may be identified and potentially corrected using our hybrid sequence.


Assuntos
Hélio , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pulmão/anatomia & histologia , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Ventilação Pulmonar/fisiologia , Administração por Inalação , Adolescente , Adulto , Criança , Feminino , Hélio/administração & dosagem , Humanos , Isótopos/administração & dosagem , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Magn Reson Med ; 46(4): 667-77, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11590642

RESUMO

An optimized interleaved-spiral pulse sequence, providing high spatial and temporal resolution, was developed for dynamic imaging of pulmonary ventilation with hyperpolarized (3)He, and tested in healthy volunteers and patients with lung disease. Off-resonance artifacts were minimized by using a short data-sampling period per interleaf, and gradient-fidelity errors were compensated for by using measured k-space trajectories for image reconstruction. A nonsequential acquisition order was implemented to improve image quality during periods of rapid signal change, such as early inspiration. Using a sliding-window reconstruction, cine-movies with a frame rate of 100 images per second were generated. Dynamic images demonstrating minimal susceptibility- and motion-induced artifacts were obtained in sagittal, coronal, and axial orientations. The pulse sequence had the flexibility to image multiple slices almost simultaneously. Our initial experience in healthy volunteers and subjects with lung pathology demonstrated the potential of this new tool for capturing the features of lung gas-flow dynamics.


Assuntos
Pneumopatias/patologia , Pneumopatias/fisiopatologia , Pulmão/anatomia & histologia , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Troca Gasosa Pulmonar , Hélio , Humanos , Isótopos
4.
J Magn Reson Imaging ; 13(3): 378-84, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11241810

RESUMO

Asthma is a disease characterized by chronic inflammation and reversible obstruction of the small airways resulting in impaired pulmonary ventilation. Hyperpolarized 3He magnetic resonance (MR) lung imaging is a new technology that provides a detailed image of lung ventilation. Hyperpolarized 3He lung imaging was performed in 10 asthmatics and 10 healthy subjects. Seven asthmatics had ventilation defects distributed throughout the lungs compared with none of the normal subjects. These ventilation defects were more numerous and larger in the two symptomatic asthmatics who had abnormal spirometry. Ventilation defects studied over time demonstrated no change in appearance over 30-60 minutes. One asthmatic subject was studied twice in a three-week period and had ventilation defects which resolved and appeared in that time. This same subject was studied before and after bronchodilator therapy, and all ventilation defects resolved after therapy. Hyperpolarized 3He lung imaging can detect the small, reversible ventilation defects that characterize asthma. The ability to visualize lung ventilation offers a direct method of assessing asthmatics and their response to therapy.


Assuntos
Asma/diagnóstico , Hélio , Aumento da Imagem , Imageamento por Ressonância Magnética , Troca Gasosa Pulmonar/fisiologia , Adulto , Asma/fisiopatologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Isótopos , Masculino , Variações Dependentes do Observador , Espirometria
5.
J Magn Reson Imaging ; 12(6): 1009-13, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11105043

RESUMO

Assessment of the uterine cavity and patency of the fallopian tubes remains a difficult goal with magnetic resonance imaging (MRI). The purpose of this paper is to describe the development of a new magnetic resonance hysterography (MR-HG) and hysterosalpingography (MR-HSG) technique employing hyperpolarized (3)He. Two-dimensional (2D) and 3D gradient-echo imaging sequences were developed and optimized using a phantom. An optimized sequence was then applied in swine cadavers. J. Magn. Reson. Imaging 2000;12:1009-1013.


Assuntos
Tubas Uterinas/anatomia & histologia , Histerossalpingografia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Útero/anatomia & histologia , Animais , Meios de Contraste , Feminino , Hélio , Humanos , Isótopos , Imagens de Fantasmas , Suínos
6.
Magn Reson Med ; 44(5): 813-6, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11064418

RESUMO

Hyperpolarized gas MR virtual colonography was performed in plastic phantoms and in the dog colon. (3)He was laser polarized in a prototype commercial system. 2D and 3D gradient echo sequences were used to image the noble gas-filled structures. The hyperpolarized (3)He within the plastic tube and colon lumen produced high signal, providing excellent contrast from the surrounding structures. The virtual colonoscopic analysis of the canine dataset allowed visualization of the colonic features and the colonic wall from inside the colon. (3)He colonoscopy is a novel technique to visualize the colon with MRI with the application of an inert gaseous endoluminal contrast agent.


Assuntos
Colo/anatomia & histologia , Meios de Contraste/metabolismo , Hélio/metabolismo , Imageamento por Ressonância Magnética/métodos , Animais , Neoplasias do Colo/diagnóstico , Cães , Estudos de Viabilidade
7.
Magn Reson Med ; 44(3): 349-57, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10975884

RESUMO

One of the major goals of hyperpolarized-gas MRI has been to obtain (129)Xe dissolved-phase images in humans. So far, this goal has remained elusive, mainly due to the low concentration of xenon that dissolves in tissue. A method is proposed and demonstrated in dogs that allows information about the dissolved phase to be obtained by imaging the gas phase following the application of a series of RF pulses that selectively destroy the longitudinal magnetization of xenon dissolved in the lung parenchyma. During the delay time between consecutive RF pulses, the depolarized xenon rapidly exchanges with the gas phase, thus lowering the gas polarization. It is demonstrated that the resulting contrast in the (129)Xe gas image provides information about the local tissue density. It is further argued that minor pulse-sequence modifications may provide information about the alveolar surface area or lung perfusion.


Assuntos
Processamento de Imagem Assistida por Computador , Pulmão/anatomia & histologia , Pulmão/metabolismo , Imageamento por Ressonância Magnética , Troca Gasosa Pulmonar/fisiologia , Xenônio/metabolismo , Animais , Compartimentos de Líquidos Corporais/fisiologia , Brônquios/anatomia & histologia , Brônquios/metabolismo , Cães , Feminino , Espectroscopia de Ressonância Magnética/métodos , Masculino , Ventilação Pulmonar/fisiologia , Ondas de Rádio , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Traqueia/anatomia & histologia , Traqueia/metabolismo , Xenônio/farmacocinética
8.
Radiology ; 216(3): 891-9, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10966728

RESUMO

The development and optimization of spin-echo-based, single-slab, three-dimensional techniques for magnetic resonance imaging of the whole brain are described. T1-weighted and T2-weighted image sets with a volume resolution of 1 mm(3) and fluid-attenuated inversion-recovery image sets with a volume resolution of 3 mm(3) were obtained in acquisition times of less than 10 minutes per image set.


Assuntos
Encéfalo/anatomia & histologia , Imagem Ecoplanar , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Artefatos , Simulação por Computador , Humanos , Software
9.
NMR Biomed ; 13(4): 220-8, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10867700

RESUMO

One of the major goals of hyperpolarized-gas MR imaging has been to obtain (129)Xe dissolved-phase images in humans. Since the dissolved-phase signal is much weaker than the gas-phase signal, highly optimized MR pulse sequences are required to obtain adequate images during a single breath-hold. In particular, a solid understanding of the temporal dynamics of xenon as it passes from the lung gas spaces into the parenchyma, the blood and other downstream compartments is absolutely essential. Spectroscopy experiments were performed in the canine chest to elucidate the behavior of xenon exchange in the lung. The experiments covered a time range from 1 ms to 9 s and therefore considerably extend the data currently available in the literature. It was found that the integrals of the dissolved-phase resonances approached plateau values within approximately 200 ms, and then increased again after approximately 1 s. This behavior suggests an early saturation of the parenchyma before xenon reaches downstream compartments. Mono-exponential recovery curves with time constants on the order of 100 ms were fit to the data. These results potentially provide information on several underlying physiological parameters of the lung, including the parenchymal and blood volumes as well as the diffusion properties of lung tissue.


Assuntos
Pulmão/fisiologia , Mecânica Respiratória , Radioisótopos de Xenônio , Animais , Cães , Feminino , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Masculino , Testes de Função Respiratória , Fatores de Tempo
10.
Magn Reson Imaging ; 17(8): 1203-10, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10499682

RESUMO

Lipid characterization of bone marrow in vivo with proton magnetic resonance spectroscopy was performed using Spin-Echo Planar Spectroscopic Imaging sequences. The methods are shown capable of rapidly generating two-dimensional chemical shift imaging data sets suitable for measuring lipid indices that reflect unsaturation levels among triglycerides, as demonstrated in oil phantoms and bone marrow from a healthy volunteer. The volume coverage, spatial resolution, acquisition speed, and spectral characteristics of Spin-Echo Planar Spectroscopic Imaging should make it attractive for clinical studies of diseases affecting normal lipid chemical composition.


Assuntos
Medula Óssea/química , Imagem Ecoplanar , Lipídeos/análise , Espectroscopia de Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/química , Imagens de Fantasmas , Valores de Referência , Marcadores de Spin , Triglicerídeos/análise
11.
J Magn Reson ; 139(2): 225-31, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10423359

RESUMO

We have investigated the transfer of polarization from (129)Xe to solute protons in aqueous solutions to determine the feasibility of using hyperpolarized xenon to enhance (1)H sensitivity in aqueous systems at or near room temperatures. Several solutes, each of different molecular weight, were dissolved in deuterium oxide and although large xenon polarizations were created, no significant proton signal enhancement was detected in l-tyrosine, alpha-cyclodextrin, beta-cyclodextrin, apomyoglobin, or myoglobin. Solute-induced enhancement of the (129)Xe spin-lattice relaxation rate was observed and depended on the size and structure of the solute molecule. The significant increase of the apparent spin-lattice relaxation rate of the solution phase (129)Xe by alpha-cyclodextrin and apomyoglobin indicates efficient cross relaxation. The slow relaxation of xenon in beta-cyclodextrin and l-tyrosine indicates weak coupling and inefficient cross relaxation. Despite the apparent cross-relaxation effects, all attempts to detect the proton enhancement directly were unsuccessful. Spin-lattice relaxation rates were also measured for Boltzmann (129)Xe in myoglobin. The cross-relaxation rates were determined from changes in (129)Xe relaxation rates in the alpha-cyclodextrin and myoglobin solutions. These cross-relaxation rates were then used to model (1)H signal gains for a range of (129)Xe to (1)H spin population ratios. These models suggest that in spite of very large (129)Xe polarizations, the (1)H gains will be less than 10% and often substantially smaller. In particular, dramatic (1)H signal enhancements in lung tissue signals are unlikely.


Assuntos
Espectroscopia de Ressonância Magnética , Isótopos de Xenônio/análise , Apoproteínas/química , Ciclodextrinas/química , Espectroscopia de Ressonância Magnética/métodos , Mioglobina/química , Prótons , Soluções/química , Tirosina/química , Água
12.
Radiology ; 210(3): 851-7, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10207491

RESUMO

Thirty-two magnetic resonance imaging examinations of the lungs were performed in 16 subjects after inhalation of 1-2 L of helium 3 gas that was laser polarized to 10%-25%. The distribution of the gas was generally uniform, with visualization of the fissures in most cases. Ventilation defects were demonstrated in smokers and in a subject with allergies. The technique has potential for evaluating small airways disease.


Assuntos
Hélio , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Administração por Inalação , Adulto , Idoso , Asma/patologia , Feminino , Hélio/administração & dosagem , Humanos , Processamento de Imagem Assistida por Computador , Isótopos , Lasers , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Oxigênio/sangue , Enfisema Pulmonar/patologia , Respiração , Rinite Alérgica Sazonal/patologia , Fumar/patologia
13.
Magn Reson Med ; 37(6): 809-15, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9178229

RESUMO

Using a new method of xenon laser-polarization that permits the generation of liter quantities of hyperpolarized 129Xe gas, the first 129Xe imaging results from the human chest and the first 129Xe spectroscopy results from the human chest and head have been obtained. With polarization levels of approximately 2%, cross-sectional images of the lung gas-spaces with a voxel volume of 0.9 cm3 (signal-to-noise ratio (SNR), 28) were acquired and three dissolved-phase resonances in spectra from the chest were detected. In spectra from the head, one prominent dissolved-phase resonance, presumably from brain parenchyma, was detected. With anticipated improvements in the 129Xe polarization system, pulse sequences, RF coils, and breathing maneuvers, these results suggest the possibility for 129Xe gas-phase imaging of the lungs with a resolution approaching that of current conventional thoracic proton imaging. Moreover, the results suggest the feasibility of dissolved-phase imaging of both the chest and brain with a resolution similar to that obtained with the gas-phase images.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Isótopos de Xenônio , Adulto , Encéfalo/anatomia & histologia , Feminino , Humanos , Pulmão/anatomia & histologia , Masculino
14.
Magn Reson Med ; 36(2): 306-13, 1996 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8843385

RESUMO

Echo-time shifting (ETS) is used in GRASE and interleaved-EPI sequences to improve the phase evolutions for off-resonance signal sources. However, even with ETS the phase evolutions still exhibit discontinuities. In this work, we extend previous studies of ETS by quantitatively evaluating the magnitude and form of the image artifacts that result from these phase discontinuities. The functional form of the phase evolution is used to derive the general conditions under which artifacts are expected. The artifacts for two sequence structures are then evaluated as a function of off-resonance frequency and data sampling period by calculating point spread functions and simulated images. It was found that even when ETS is used to improve the phase evolutions, periodic phase discontinuities may degrade image quality by producing ghosting artifacts of edges. These artifacts are similar to those that commonly occur with periodic motion. From our results recommendations are derived for limiting the ghosting artifacts.


Assuntos
Imageamento por Ressonância Magnética/métodos , Artefatos , Cabeça/anatomia & histologia , Humanos
15.
Magn Reson Med ; 35(2): 237-45, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8622589

RESUMO

The signal evolution behaviors and corresponding image appearances for different methods of spoiling or refocusing the transverse magnetization in short TR gradient-echo imaging during the approach to steady state were investigated experimentally and using computer simulations based on the Bloch equations. Specifically, ideally spoiled, gradient-spoiled, gradient-refocused, and RF-spoiled pulse sequence configurations were studied. This study showed that, for the gradient-spoiled configuration, the signal evolution is position and phase-encoding order-dependent and, under typical imaging conditions, can deviate substantially from the ideally spoiled signal evolution at some spatial positions, resulting in intensity banding image artifacts. For the gradient-refocused configuration, the signal evolution oscillates toward the steady state and, generally, does not closely approximate that of ideal spoiling, resulting in different image contrast or image blurring. Using RF spoiling, the signal evolution closely approximates the ideally spoiled case for flip angles less than approximately 20 degrees and T2 values of less than approximately 200 ms and results in relatively artifact-free images. Also, this study showed that, for RF spoiling, an RF-pulse phase-difference increment other than 117 degrees, such as 84 degrees may be optimal for gradient-echo imaging during the approach to steady state.


Assuntos
Imageamento por Ressonância Magnética/métodos , Abdome/patologia , Artefatos , Ascite/diagnóstico , Simulação por Computador , Humanos , Magnetismo , Imagens de Fantasmas
16.
J Magn Reson Imaging ; 5(4): 463-9, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7549212

RESUMO

Fluid-attenuated inversion recovery (FLAIR) is a pulse sequence used for acquiring T2-weighted images of the brain and spine in which the normally high signal intensity of CSF is greatly attenuated. The CSF-suppressed T2-weighted contrast of this technique may be more sensitive to a variety of disorders than that of conventional T2-weighted imaging. The primary disadvantage associated with conventional spin-echo implementations of FLAIR is the relatively limited anatomic coverage that can be achieved in a reasonable imaging time. We developed and optimized a three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) pulse sequence that combines CSF-suppressed T2-weighted contrast similar to existing FLAIR techniques with anatomic coverage characteristic of 3D imaging. A preliminary evaluation of the new sequence was performed by imaging healthy volunteers and patients with multiple sclerosis.


Assuntos
Encéfalo/anatomia & histologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Encéfalo/patologia , Líquido Cefalorraquidiano , Humanos , Imagens de Fantasmas , Medula Espinal/anatomia & histologia , Coluna Vertebral/anatomia & histologia
18.
Magn Reson Med ; 31(4): 414-22, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8208117

RESUMO

A three-dimensional (3D), ECG-triggered, selective inversion recovery (SIR) rapid gradient-echo (RAGE) technique is proposed to obtain MR angiograms of the main renal arteries. By using the selective inversion recovery and fat saturation, the background is significantly suppressed while blood maintains a high signal intensity as compared with conventional 3D time-of-flight (TOF) MR angiography. The sequence is ECG-triggered so that blood in-flow is maximized during systole, and intravoxel dephasing and pulsatile flow artifacts are minimized by collecting data during diastole. As a result, vessel boundary blurring and ghosting artifacts due to background motion are dramatically reduced, and the conspicuity and lumen definition of the arteries are significantly improved. High-quality MR angiograms of the main renal arteries with excellent blood/tissue contrast and suppression of motion artifacts have been consistently obtained for normal volunteers, with the length of visualization being 51 +/- 07 mm for the left, and 57 +/- 06 mm for the right renal arteries, significantly greater than using conventional 3D TOF pulse sequences. Statistical analysis was performed by using a one-sided Student's t test.


Assuntos
Angiografia/métodos , Imageamento por Ressonância Magnética/métodos , Artéria Renal/patologia , Humanos , Tecnologia Radiológica
19.
Magn Reson Med ; 31(2): 164-77, 1994 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8133752

RESUMO

A number of pulse sequence techniques, including magnetization-prepared gradient echo (MP-GRE), segmented GRE, and hybrid RARE, employ a relatively large number of variable pulse sequence parameters and acquire the image data during a transient signal evolution. These sequences have recently been proposed and/or used for clinical applications in the brain, spine, liver, and coronary arteries. Thus, the need for a method of deriving optimal pulse sequence parameter values for this class of sequences now exists. Due to the complexity of these sequences, conventional optimization approaches, such as applying differential calculus to signal difference equations, are inadequate. We have developed a general framework for adapting the simulated annealing algorithm to pulse sequence parameter value optimization, and applied this framework to the specific case of optimizing the white matter-gray matter signal difference for a T1-weighted variable flip angle 3D MP-RAGE sequence. Using our algorithm, the values of 35 sequence parameters, including the magnetization-preparation RF pulse flip angle and delay time, 32 flip angles in the variable flip angle gradient-echo acquisition sequence, and the magnetization recovery time, were derived. Optimized 3D MP-RAGE achieved up to a 130% increase in white matter-gray matter signal difference compared with optimized 3D RF-spoiled FLASH with the same total acquisition time. The simulated annealing approach was effective at deriving optimal parameter values for a specific 3D MP-RAGE imaging objective, and may be useful for other imaging objectives and sequences in this general class.


Assuntos
Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/anatomia & histologia , Algoritmos , Artefatos , Núcleo Caudado/anatomia & histologia , Ventrículos Cerebrais/anatomia & histologia , Líquido Cefalorraquidiano , Simulação por Computador , Humanos , Modelos Estruturais , Modelos Teóricos , Putamen/anatomia & histologia , Língua/anatomia & histologia
20.
J Magn Reson Imaging ; 4(1): 91-8, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-8148563

RESUMO

The recently introduced method of shaping the transient signal evolution in magnetization-prepared gradient-echo (MP-GRE) imaging with variable flip angles has been applied to two-dimensional (2D) MP-GRE imaging of the abdomen. The technique was analyzed by using theoretical models and was implemented on a standard 1.5-T whole-body imager with a segmented acquisition. Theoretical models predicted that the variable-flip-angle 2D MP-GRE sequence would increase liver-spleen signal difference--to-noise ratios by 290%, 110%, and 160% compared with a 2D MP-GRE sequence with a flip angle of 10 degrees and sequential phase encoding, a 2D MP-GRE sequence with a flip angle of 30 degrees and centric phase encoding, and the fast low-angle shot sequence, respectively. Experimental measurements supported the theoretical predictions.


Assuntos
Algoritmos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Baço/anatomia & histologia , Humanos , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...