Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS Negl Trop Dis ; 5(11): e1384, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22132246

RESUMO

BACKGROUND: Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. METHODOLOGY: We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A and B are endemic for S. mansoni, whereas S. haematobium co-exists in setting C. Overall, 446 children, aged 8-12 years, submitted multiple stool and urine samples. For S. mansoni diagnosis, stool samples were examined with triplicate Kato-Katz, whereas urine samples were tested with CCA-A. The first stool and urine samples were additionally subjected to an ether-concentration technique and CCA-B, respectively. Urine samples were examined for S. haematobium using a filtration method, and for microhematuria using Hemastix dipsticks. PRINCIPAL FINDINGS: Considering nine Kato-Katz as diagnostic 'gold' standard, the prevalence of S. mansoni in setting A, B and C was 32.9%, 53.1% and 91.8%, respectively. The sensitivity of triplicate Kato-Katz from the first stool and a single CCA-A test was 47.9% and 56.3% (setting A), 73.9% and 69.6% (setting B), and 94.2% and 89.6% (setting C). The respective sensitivity of a single CCA-B was 10.4%, 29.9% and 75.0%. The ether-concentration technique showed a low sensitivity for S. mansoni diagnosis (8.3-41.0%). The specificity of CCA-A was moderate (76.9-84.2%); CCA-B was high (96.7-100%). The likelihood of a CCA-A color reaction increased with higher S. mansoni fecal egg counts (odds ratio: 1.07, p<0.001). A concurrent S. haematobium infection or the presence of microhematuria did not influence the CCA-A test results for S. mansoni diagnosis. CONCLUSION/SIGNIFICANCE: CCA-A showed similar sensitivity than triplicate Kato-Katz for S. mansoni diagnosis with no cross-reactivity to S. haematobium and microhematuria. The low sensitivity of CCA-B in our study area precludes its use for S. mansoni diagnosis.


Assuntos
Antígenos de Helmintos/urina , Técnicas de Laboratório Clínico/métodos , Glicoproteínas/urina , Proteínas de Helminto/urina , Parasitologia/métodos , Esquistossomose mansoni/diagnóstico , Animais , Criança , Côte d'Ivoire , Estudos Transversais , Fezes/química , Feminino , Humanos , Imunoensaio/métodos , Masculino , Prevalência , Sensibilidade e Especificidade , Urina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...