Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
2.
Plast Reconstr Surg Glob Open ; 9(10): e3888, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34712545

RESUMO

BACKGROUND: The zygomaticomaxillary complex (ZMC) can experience a multitude of deforming forces. There is limited understanding on which deformities alter patient outcomes. This study utilized an automated, three-dimensional analysis to elucidate which fracture patterns and rotational deformities are most prevalent and associated with postoperative complications. METHODS: This study was a 7-year retrospective review of patients with unilateral ZMC fractures who underwent surgical intervention. Patient demographics, injury mechanisms, presenting symptoms, and postoperative outcomes were collected. Segmentation was completed using Mimics software. The lateral-medial, superior-inferior, and anterior-posterior axes were manually identified on the zygoma and then displacement, rotational direction, and rotational degrees were automatically calculated using Geomagic software. Total displacement score was generated by summation of individual displacement scores at each of the five sutures. RESULTS: Eighty-one patients satisfied inclusion criteria. The most prevalent rotational pattern of the zygoma was medially-superiorly-posteriorly (P < 0.001). When comparing rotation along the three axes, the zygoma had the greatest rotation along the lateral-medial axis compared with the superior-inferior (P = 0.003) and anterior-posterior (P < 0.001) axes. Within each axis, the zygoma was more likely to rotate medially than laterally (P = 0.003) and posteriorly than anteriorly (P = 0.01). Multivariate analysis identified total displacement scores and degrees rotated along the lateral-medial axis as significant predictors of facial complications and reoperation. CONCLUSIONS: This study suggests that patients with unilateral ZMC fractures who undergo surgical intervention are at an increased risk for adverse outcomes with greater rotation along the lateral-medial axis and higher total displacement scores. Additionally, the automated analysis method described can provide objective data to better characterize ZMC fractures.

3.
Polymers (Basel) ; 13(7)2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33918135

RESUMO

Original perfluoropolyether (PFPE)-based oligomeric polyurethanes (FOPUs) with different macromolecular architecture were synthesized (in one step) as low-surface-energy materials. It is demonstrated that the oligomers, especially the ones terminated with CF3 moieties, can be employed as safer replacements to long-chain perfluoroalkyl substances/additives. The FOPU macromolecules, when added to an engineering thermoplastic (polyethylene terephthalate, PET) film, readily migrate to the film surface and bring significant water and oil repellency to the thermoplastic boundary. The best performing FOPU/PET films have reached the level of oil wettability and surface energy significantly lower than that of polytetrafluoroethylene, a fully perfluorinated polymer. Specifically, the highest level of the repellency is observed with an oligomeric additive, which was made using aromatic diisocyanate as a comonomer and has CF3 end-group. This semicrystalline oligomer has a glass transition temperature (Tg) well above room temperature, and we associate the superiority of the material in achieving low water and oil wettability with its ability to effectively retain CF3 and CF2 moieties in contact with the test wetting liquids.

4.
Int Health ; 13(6): 624-632, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33751057

RESUMO

BACKGROUND: The Medical Equipment Network Documentation System (MENDS) provides a simple communication network for equipment servicing from failure to restoration. It is a text messaging-based platform, designed to use existing technologies in place in low- and middle-income settings. The system gathers and relays information about equipment service requests and reports and automatically saves them to an online database. METHODS: MENDS was deployed at a high volume, rural, charity medical facility in Kijabe, Kenya for a 3-mo pilot test. RESULTS: The results show MENDS more than tripled documentation and enhanced ease and speed of communication. CONCLUSIONS: Comprehensive data provided by MENDS created more accurate measures of equipment performance, which can be used to decrease the time that equipment is out of service and improve the efficiency of repairs, equipment quality and procurement.


Assuntos
Hospitais Rurais , Envio de Mensagens de Texto , Documentação , Humanos , Renda , Quênia
5.
J Anat ; 238(6): 1472-1491, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33417250

RESUMO

The meaning of the term 'abdomen' has become increasingly ambiguous, as it has to satisfy the contemporary requirements of natural language discourse, literature, gross and radiological anatomy and its role in ontologies supporting electronic records and data modelling. It is critical that there is an agreed understanding of the semantics of the abdominopelvic cavity, its component volumes including the abdomen proper, true and false pelvic cavities, and its boundaries and regional contents. The expression of part-whole (meronymic) relationships is essential for inferences to be drawn by computer algorithms, but unless these are rigorously reviewed and tested incorrect assumptions are drawn. The SNOMED CT terminology descriptions and hierarchy of anatomical concepts relating to the trunk were scrutinised for ambiguity and sub-optimal relationships using a panel of reference sources. Any identified errors were corrected and the impact of any changes reviewed iteratively by evaluating their effect on dependant hierarchies (modelled with the associated anatomical concepts). Anatomical concepts are generally structured according to a traditional gross standpoint, but in clinical practice covert complex regional notions are frequently used and during the evaluation process a new viewpoint relating to projectional (transmissive) or emissive radiological perspective was identified. The subtle but important differences in the boundaries, volumes and contents of these distinctive perspectives of the 'abdomen' are presented. Three significant complex variants have been identified which relate to the most common uses of the word 'abdomen'. The merits and disadvantages of using 'abdomen' as common synonym to more than one concept (polysemy) are briefly discussed and the solution adopted by SNOMED International described. The review of existing ontologies and academic literature confirmed the frequent varied use of the word 'abdomen', which raises concerns when derived data are increasingly being used remotely from the point of clinical contact, potentially leading to incorrect inferences. The documented regional truncal volumes from an anatomical regional, segmental and cross-sectional perspective have been integrated into a logical and comprehensive model suitable for computer processing. The robust modelling of meronymic hierarchies has to be rigorous to avoid systematic errors and it is thus timely that a proposed standard description of these subtly related volumes and structures is made available for discussion and comment.


Assuntos
Abdome/anatomia & histologia , Algoritmos , Estudos Transversais , Humanos , Systematized Nomenclature of Medicine
6.
Ophthalmic Plast Reconstr Surg ; 37(1): 81-85, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32433352

RESUMO

PURPOSE: This study seeks to test a novel technique of custom-printed midface contour models with orbital floor "stamps" to guide reconstruction of orbital floor blowout fractures, with or without concomitant zygomaticomaxillary complex injury. METHODS: A series of 4 consecutive patients with orbital floor blowout fractures (including 3 with zygomatic maxillary complex fractures) were retrospectively examined for outcomes associated with orbital floor reconstruction using 3-dimensional-printed stamps and midface models. Data collected included demographics, pre- and postoperative visual globe malposition, motility, and visual field disturbances. Three-dimensional printing methodology is reported, as well as associated costs and time required to generate the models and stamps. RESULTS: The cost of producing a midface-contour model and orbital floor stamps was $131, inclusive of labor and materials. Cases averaged 170 minutes to segment, design, and print. Patients with preoperative diplopia and motility restrictions had resolution of their symptoms. Two patients had resolution of their enophthalmos, while one patient with a concomitant zygomaticomaxillary fracture had persistent mild enophthalmos. CONCLUSIONS: Midface contour models and orbital floor stamps may be produced in a timely and cost-effective manner. Use of these "homemade" stamps allows for patient-specific custom-contoured orbital floor reconstruction. Further studies are warranted to examine long-term visual and esthetic outcomes for these patients.


Assuntos
Enoftalmia , Fraturas Maxilares , Fraturas Orbitárias , Implantes Orbitários , Procedimentos de Cirurgia Plástica , Fraturas Zigomáticas , Enoftalmia/etiologia , Enoftalmia/cirurgia , Humanos , Fraturas Orbitárias/cirurgia , Impressão Tridimensional , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
Plast Reconstr Surg Glob Open ; 8(5): e2831, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-33154873

RESUMO

Industry-printed (IP) 3-dimensional (3D) models are commonly used for secondary midfacial reconstructive cases but not for acute cases due to their high cost and long turnaround time. We have begun using in-house (IH) printed models for complex unilateral midface trauma. We hypothesized that IH models would decrease cost and turnaround time, compared with IP models. METHODS: We retrospectively examined cost and turnaround time data from midface trauma cases performed in 2017-2019 using 3D models (total, n = 15; IH, n = 10; IP, n = 5). Data for IH models were obtained through itemized cost reports from our Biomedical Engineering Department, where the models were printed. Data associated with IP models were obtained through itemized cost reports from our industry vendor. Perioperative data were collected from electronic medical records. RESULTS: The average cost for IH models ($236.38 ± 26.17) was significantly less (P < 0.001) than that for IP models ($1677.82 ± 488.43). Minimal possible time from planning to model delivery was determined. IH models could be produced in as little as 4.65 hours, whereas the IP models required a minimum of 5 days (120 hours) from order placement. There were no significant differences in average operating room time (P = 0.34), surgical complications, or subjective outcomes, but there was a significant difference in estimated blood loss (P = 0.04). CONCLUSION: Utilization of IH 3D skull models is a creative and practical adjunct to complex unilateral midfacial trauma that also reduces cost and turnaround time compared with IP 3D models.

8.
Ann Biomed Eng ; 48(1): 258-270, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31520331

RESUMO

Head injury is a growing concern within contact sports, including American football. Computational tools such as finite element (FE) models provide an avenue for researchers to study, and potentially optimize safety tools, such as helmets. The goal of this study was to develop an accurate representative helmet model that could be used in further study of head injury to mitigate the toll of concussions in contact sports. An FE model of a Schutt Air XP Pro football helmet was developed through three major steps: geometry development, material characterization, and model validation. The fully assembled helmet model was fit onto a Hybrid III dummy head-neck model and National Operating Committee on Standards for Athletic Equipment (NOCSAE) head model and validated through a series of 67 representative impacts similar to those experienced by a football player. The kinematic and kinetic response of the model was compared to the response of the physical experiments, which included force, head linear acceleration, head angular velocity, and carriage acceleration. The outputs between the model and the physical tests were quantitatively evaluated using CORelation and Analysis (CORA), amounting to an overall averaged score of 0.76. The model described in this study has been extensively validated and can function as a building block for innovation in player safety.


Assuntos
Traumatismos em Atletas/prevenção & controle , Traumatismos Craniocerebrais/prevenção & controle , Futebol Americano/lesões , Dispositivos de Proteção da Cabeça , Modelos Teóricos , Análise de Falha de Equipamento , Análise de Elementos Finitos , Equipamentos Esportivos
9.
Ann Biomed Eng ; 48(2): 903, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31845126

RESUMO

This correction is to add the middle initials of all authors, which were inadvertently omitted from the original article.

10.
Langmuir ; 34(43): 12934-12946, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30272982

RESUMO

For decades, water and oil repellency of engineering thermoplastics has been achieved with introduction of long-chain perfluoroalkyl substances and moieties (C nF2 n+1, n ≥ 7). However, their bioaccumulative and toxicological impact is now widely recognized and, consequently, the substances have been phased out of industrial production and applications. To this end, we have synthesized fluorinated oligomeric triblock polyesters (FOPBs), which do not possess the long-chain perfluoroalkyl segments and serve as effective low-surface-energy additives to engineering thermoplastics. More specifically, we obtained original perfluoropolyether (PFPE)-based triblock copolymers, in which two identical fluorinated blocks were separated by a short nonfluorinated polyester block made of poly(ethylene isophthalate) (PEI). It was found that when FOPBs were added to poly(ethylene terephthalate), nylon-6, and poly(methyl methacrylate) films they readily migrate to the film surface and in doing so imparted significant water and oil repellency to the thermoplastic boundary. The water/oil wettability of the films modified with FOPB is considerably lower than the wettability of the films modified with an analogous PFPE-based polyester, which differs from FOPB only by the absence of the short nonfluorinated PEI middle block. We associate the superiority of the triblock copolymers in terms of water and oil repellency with their ability to form brushlike structures on polymer film surfaces.

11.
J Orthop Trauma ; 31(11): 570-576, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29053542

RESUMO

OBJECTIVES: Elderly patients represent the fastest growing and most difficult to treat population sustaining acetabular fractures. When treated surgically, isolated extrapelvic or combined intrapelvic-extrapelvic constructs may be used. No biomechanical or clinical study has compared the merits of these 2 techniques in cadaveric models. This research aims to biomechanically quantify the additional benefit of intrapelvic fixation to a standard extrapelvic fixation construct. METHODS: Ten cadaveric pelves underwent standardized anterior column and quadrilateral plate fracture creation. One hemipelvis from each subject received isolated extrapelvic fixation, whereas the other received adjunctive intrapelvic fixation. Specimens were then subjected to a 50% of body weight (BW) nondestructive stiffness test followed by loading to failure. For the 50% BW test, displacement at 50% BW and stiffness were calculated. For the load to failure test, stiffness, elastic energy, and plastic energy were calculated. Yield point, force at clinical failure (defined at 2 mm of displacement), and maximum force were also identified. A Wilcoxon matched-pairs t test was used to compare fixation groups. RESULTS: The addition of an intrapelvic plate improved construct performance for all test parameters. A statistically significant difference (P < 0.05) was reached for yield force, maximum force, and plastic energy. CONCLUSIONS: These findings demonstrate that the addition of intrapelvic plating may offer distinct advantages in prevention of catastrophic construct failure in situations in which significant lateral to medial force is applied to the greater trochanter such as patient falling.


Assuntos
Acetábulo/cirurgia , Placas Ósseas , Força Compressiva/fisiologia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Acetábulo/lesões , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Densidade Óssea , Cadáver , Dissecação , Feminino , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Tomografia Computadorizada por Raios X/métodos
12.
ACS Appl Mater Interfaces ; 9(28): 24318-24330, 2017 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-28658580

RESUMO

Original perfluoropolyethers (PFPE)-based oligomeric polyesters (FOPs) of different macromolecular architecture were synthesized via polycondensation as low surface energy additives to engineering thermoplastics. The oligomers do not contain long-chain perfluoroalkyl segments, which are known to yield environmentally unsafe perfluoroalkyl carboxylic acids. To improve the compatibility of the materials with polyethylene terephthalate (PET) we introduced isophthalate segments into the polyesters and targeted the synthesis of lower molecular weight oligomeric macromolecules. The surface properties such as morphology, composition, and wettability of PET/FOP films fabricated from solution were investigated using atomic force microscopy, X-ray photoelectron spectroscopy, and contact angle measurements. It was demonstrated that FOPs, when added to PET film, readily migrate to the film surface and bring significant water and oil repellency to the thermoplastic boundary. We have established that the wettability of PET/FOP films depends on three main parameters: (i) end-groups of fluorinated polyesters, (ii) the concentration of fluorinated polyesters in the films, and (iii) equilibration via annealing. The most effective water/oil repellency FOP has two C4F9-PFPE-tails. The addition of this oligomeric polyester to PET allows (even at relatively low concentrations) reaching a level of oil repellency and surface energy comparable to that of polytetrafluorethylene (PTFE/Teflon). Therefore, the materials can be considered suitable replacements for additives containing long-chain perfluoroalkyl substances.

13.
J Biomech Eng ; 139(5)2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28291867

RESUMO

Tissue cooling has been proven as a viable therapy for multiple conditions and injuries and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a potassium-neutralized, superabsorbent copolymer hydrogel. The phantom was tested in a series of cooling trials using a cooling block and 37 deg water representing nondirectional blood flow ranging up to 6 gph, a physiologically representative range based on the prototype volume. Results were compared against a validated finite difference (FD) model. Two sets of parameters were used in the FD model: one set to represent the phantom itself and a second set to represent brain parenchyma. The model was then used to calculate steady-state cooling at a depth of 5 mm for all flow rates, for both the phantom and a model of the brain. This effort was undertaken to (1) validate the FD model against the phantom results and (2) evaluate how similar the thermal response of the phantom is to that of a perfused brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally mediated therapies applied to the cerebral cortex.


Assuntos
Encéfalo , Hipotermia Induzida/instrumentação , Imagens de Fantasmas
14.
Surg Technol Int ; 29: 247-254, 2016 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-27466872

RESUMO

Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (p< 0.05). The 8mm single bore technique removed a significantly larger volume of bone compared to the 3mm multiple drilling technique (p< 0.001). However, total fracture energy was similar between the two core decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.


Assuntos
Descompressão Cirúrgica , Necrose da Cabeça do Fêmur/cirurgia , Cadáver , Fêmur , Cabeça do Fêmur/patologia , Colo do Fêmur/patologia , Humanos
15.
Haematologica ; 101(7): 861-71, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27056922

RESUMO

Strong FOXP1 protein expression is a poor risk factor in diffuse large B-cell lymphoma and has been linked to an activated B-cell-like subtype, which preferentially expresses short FOXP1 (FOXP1S) proteins. However, both short isoform generation and function are incompletely understood. Here we prove by mass spectrometry and N-terminal antibody staining that FOXP1S proteins in activated B-cell-like diffuse large B-cell lymphoma are N-terminally truncated. Furthermore, a rare strongly FOXP1-expressing population of normal germinal center B cells lacking the N-terminus of the regular long protein (FOXP1L) was identified. Exon-targeted silencing and transcript analyses identified three alternate 5' non-coding exons [FOXP1-Ex6b(s), FOXP1-Ex7b and FOXP1-Ex7c], downstream of at least two predicted promoters, giving rise to FOXP1S proteins. These were differentially controlled by B-cell activation and methylation, conserved in murine lymphoma cells, and significantly correlated with FOXP1S protein expression in primary diffuse large B-cell lymphoma samples. Alternatively spliced isoforms lacking exon 9 (e.g. isoform 3) did not encode FOXP1S, and an alternate long human FOXP1 protein (FOXP1AL) likely generated from a FOXP1-Ex6b(L) transcript was detected. The ratio of FOXP1L:FOXP1S isoforms correlated with differential expression of plasmacytic differentiation markers in U-2932 subpopulations, and altering this ratio was sufficient to modulate CD19 expression in diffuse large B-cell lymphoma cell lines. Thus, the activity of multiple alternate FOXP1 promoters to produce multiple protein isoforms is likely to regulate B-cell maturation.


Assuntos
Linfócitos B/metabolismo , Fatores de Transcrição Forkhead/genética , Fatores de Transcrição Forkhead/metabolismo , Regulação Neoplásica da Expressão Gênica , Linfoma Difuso de Grandes Células B/genética , Regiões Promotoras Genéticas , Domínios e Motivos de Interação entre Proteínas/genética , Proteínas Repressoras/genética , Proteínas Repressoras/metabolismo , Processamento Alternativo , Animais , Antígenos CD19/genética , Antígenos CD19/metabolismo , Linhagem Celular Tumoral , Éxons , Fatores de Transcrição Forkhead/química , Humanos , Ativação Linfocitária/genética , Ativação Linfocitária/imunologia , Linfoma Difuso de Grandes Células B/patologia , Camundongos , Isoformas de Proteínas , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Proteínas Repressoras/química
16.
Spine J ; 14(9): 2195-207, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24614252

RESUMO

BACKGROUND CONTEXT: Whereas arthrodesis is the most common surgical intervention for the treatment of symptomatic cervical degenerative disc disease, arthroplasty has become increasingly more popular over the past decade. Although literature exists comparing the effects of anterior cervical discectomy and fusion and cervical total disc replacement (CTDR) on neck kinematics and loading, the vast majority of these studies apply only quasi-static, noninjurious loading conditions to a segment of the cervical spine. PURPOSE: The objective of this study was to investigate the effects of arthrodesis and arthroplasty on biomechanical neck response during a simulated frontal automobile collision with air bag deployment. STUDY DESIGN: This study used a full-body, 50th percentile seated male finite element (FE) model to evaluate neck response during a dynamic impact event. The cervical spine was modified to simulate either an arthrodesis or arthroplasty procedure at C5-C6. METHODS: Five simulations of a belted driver, subjected to a 13.3 m/s ΔV frontal impact with air bag deployment, were run in LS-DYNA with the Global Human Body Models Consortium full-body FE model. The first simulation used the original model, with no modifications to the neck, whereas the remaining four were modified to represent either interbody arthrodesis or arthroplasty of C5-C6. Cross-sectional forces and moments at the C5 and C6 cervical levels of the neck, along with interbody and facet forces between C5 and C6, were reported. RESULTS: Adjacent-level, cross-sectional neck loading was maintained in all simulations without exceeding any established injury thresholds. Interbody compression was greatest for the CTDRs, and interbody tension occurred only in the fused and nonmodified spines. Some interbody separation occurred between the superior and inferior components of the CTDRs during flexion-induced tension of the cervical spine, increasing the facet loads. CONCLUSIONS: This study evaluated the effects of C5-C6 cervical arthrodesis and arthroplasty on neck response during a simulated frontal automobile impact. Although cervical arthrodesis and arthroplasty at C5-C6 did not appear to significantly alter the adjacent-level, cross-sectional neck responses during a simulated frontal automobile impact, key differences were noted in the interbody and facet loading.


Assuntos
Acidentes de Trânsito , Vértebras Cervicais/cirurgia , Discotomia , Manequins , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral , Substituição Total de Disco , Air Bags , Artroplastia , Automóveis , Fenômenos Biomecânicos , Estudos Transversais , Humanos , Masculino , Pescoço , Amplitude de Movimento Articular
17.
Am J Sports Med ; 42(4): 859-68, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24500915

RESUMO

BACKGROUND: Advanced patient age is associated with recurrent tearing and failure of rotator cuff repairs clinically; however, basic science studies have not evaluated the influence of aging on tendon-to-bone healing after rotator cuff repair in an animal model. Hypothesis/ PURPOSE: This study examined the effect of aging on tendon-to-bone healing in an established rat model of rotator cuff repair using the aged animal colony from the National Institute on Aging of the National Institutes of Health. The authors hypothesized that normal aging decreases biomechanical strength and histologic organization at the tendon-to-bone junction after acute repair. STUDY DESIGN: Controlled laboratory study. METHODS: In 56 F344xBN rats, 28 old and 28 young (24 and 8 months of age, respectively), the supraspinatus tendon was transected and repaired. At 2 or 8 weeks after surgery, shoulder specimens underwent biomechanical testing to compare load-to-failure and load-relaxation response between age groups. Histologic sections of the tendon-to-bone interface were assessed with hematoxylin and eosin staining, and collagen fiber organization was assessed by semiquantitative analysis of picrosirius red birefringence under polarized light. RESULTS: Peak failure load was similar between young and old animals at 2 weeks after repair (31% vs 26% of age-matched uninjured controls, respectively; P > .05) but significantly higher in young animals compared with old animals 8 weeks after repair (86% vs 65% of age-matched uninjured controls, respectively; P < .01). Eight weeks after repair, fibroblasts appeared more organized and uniformly aligned in young animals on hematoxylin and eosin slides compared with old animals. Collagen birefringence analysis of the tendon-to-bone junction demonstrated that young animals had increased collagen fiber organization and similar histologic structure compared with age-matched controls (53.7 ± 2.4 gray scales; P > .05). In contrast, old animals had decreased collagen fiber organization and altered structure compared with age-matched controls (49.8 ± 3.1 gray scales; P < .01). DISCUSSION: In a rat model of aging, old animals demonstrated diminished tendon-to-bone healing after rotator cuff injury and repair. Old animals had significantly decreased failure strength and collagen fiber organization at the tendon-to-bone junction compared with young animals. This study implies that animal age may need to be considered in future studies of rotator cuff repair in animal models. CLINICAL RELEVANCE: With increasing age and activity level of the population, the incidence of rotator cuff tears is predicted to rise. Despite advances in rotator cuff repair technique, the retear rate remains specifically high in elderly patients. The findings of this research suggest that aging negatively influences tendon-to-bone healing after rotator cuff repair in a validated animal model.


Assuntos
Úmero/cirurgia , Manguito Rotador/cirurgia , Cicatrização/fisiologia , Fatores Etários , Animais , Artroplastia , Fenômenos Biomecânicos , Colágeno/fisiologia , Modelos Animais de Doenças , Úmero/fisiopatologia , Ratos , Ratos Endogâmicos F344 , Manguito Rotador/fisiopatologia , Estresse Mecânico
18.
J Hand Surg Am ; 38(12): 2329-34, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24275055

RESUMO

PURPOSE: To compare the gliding resistance, repair gapping, and ultimate strength of a common suture construct with a modified construct with fibrin glue augmentation. METHODS: Twelve human cadaveric flexor digitorum profundus tendons were transected and repaired with a 4-strand core suture. Specimens were divided into 2 groups and augmented with epitendinous suture (n = 6) or fibrin glue (n = 6). We compared gliding resistance, 2-mm gapping, and ultimate strength of the repaired tendon between groups. RESULTS: The linear stiffness, force to produce a 2-mm gap, and ultimate failure were similar in both repair methods. However, the 4-strand suture repair with fibrin glue augmentation displayed significantly higher gliding resistance compared with the 4-strand suture with a running epitendinous suture. CONCLUSIONS: The significantly increased gliding resistance associated with fibrin glue raises questions regarding the use of this material for flexor tendon repair augmentation. CLINICAL RELEVANCE: In a human cadaveric study, fibrin glue augmentation to zone II flexor tendon repairs significantly increased friction in the tendon sheath compared with an epitendinous suture.


Assuntos
Força Compressiva , Adesivo Tecidual de Fibrina/farmacologia , Procedimentos de Cirurgia Plástica/métodos , Traumatismos dos Tendões/cirurgia , Fenômenos Biomecânicos , Cadáver , Dedos/cirurgia , Fricção , Humanos , Estresse Mecânico , Técnicas de Sutura , Tendões/cirurgia
19.
Biometrics ; 68(4): 1260-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22670567

RESUMO

This article introduces new methods for performing classification of complex, high-dimensional functional data using the functional mixed model (FMM) framework. The FMM relates a functional response to a set of predictors through functional fixed and random effects, which allows it to account for various factors and between-function correlations. The methods include training and prediction steps. In the training steps we train the FMM model by treating class designation as one of the fixed effects, and in the prediction steps we classify the new objects using posterior predictive probabilities of class. Through a Bayesian scheme, we are able to adjust for factors affecting both the functions and the class designations. While the methods can be used in any FMM framework, we provide details for two specific Bayesian approaches: the Gaussian, wavelet-based FMM (G-WFMM) and the robust, wavelet-based FMM (R-WFMM). Both methods perform modeling in the wavelet space, which yields parsimonious representations for the functions, and can naturally adapt to local features and complex nonstationarities in the functions. The R-WFMM allows potentially heavier tails for features of the functions indexed by particular wavelet coefficients, leading to a down-weighting of outliers that makes the method robust to outlying functions or regions of functions. The models are applied to a pancreatic cancer mass spectroscopy data set and compared with other recently developed functional classification methods.


Assuntos
Algoritmos , Teorema de Bayes , Modelos Estatísticos , Reconhecimento Automatizado de Padrão/métodos , Simulação por Computador
20.
Genome Biol ; 13(3): R24, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22458515

RESUMO

Here we present the Transcription Factor Encyclopedia (TFe), a new web-based compendium of mini review articles on transcription factors (TFs) that is founded on the principles of open access and collaboration. Our consortium of over 100 researchers has collectively contributed over 130 mini review articles on pertinent human, mouse and rat TFs. Notable features of the TFe website include a high-quality PDF generator and web API for programmatic data retrieval. TFe aims to rapidly educate scientists about the TFs they encounter through the delivery of succinct summaries written and vetted by experts in the field. TFe is available at http://www.cisreg.ca/tfe.


Assuntos
Biologia Computacional , Bases de Dados de Proteínas/provisão & distribuição , Fatores de Transcrição/genética , Acesso à Informação , Animais , Enciclopédias como Assunto , Humanos , Internet , Camundongos , Ratos , Transcrição Gênica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...