Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Br J Anaesth ; 66(2): 228-31, 1991 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1817626

RESUMO

Twenty-two patients undergoing total knee arthroplasty received combined sciatic plus femoral "3 in 1" blocks as adjuncts to general anaesthesia. Eleven patients received 0.375% bupivacaine 45 ml (168.75 mg) with adrenaline 1 in 200,000 and the remaining 11 received plain solution according to a previously prepared, randomized list. The mean maximum plasma bupivacaine concentration was significantly greater with plain solution than when adrenaline was added (1.66 micrograms ml-1 compared with 0.98 micrograms ml-1) (P less than 0.05). Bupivacaine concentrations were greater at all times in the plain group compared with the group receiving adrenaline. These differences were statistically significant at 10, 15 and 20 min (P less than 0.05). The greatest peak concentration recorded was 3.13 micrograms ml-1 in one patient receiving plain bupivacaine. No patient developed signs of systemic toxic effects. Peak plasma concentrations were related inversely to body weight in patients receiving solution containing adrenaline (P less than 0.005), but no relationship existed in patients who received plain solution.


Assuntos
Anestesia Local , Bupivacaína/sangue , Epinefrina/farmacologia , Prótese do Joelho , Bloqueio Nervoso , Adulto , Idoso , Feminino , Nervo Femoral , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Nervo Isquiático
2.
Br J Anaesth ; 64(2): 183-5, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2317422

RESUMO

Adverse events associated with single-holed and multi-holed extradural catheters were compared in obstetric practice. Two hundred and forty-five patients were given an extradural block using a single-holed catheter and 229 received a block via a multi-holed catheter. There was no difference in the incidence of major side effects. Flow of fluid under gravity in the catheter was restricted significantly more often in the single-holed catheters. Blood was found significantly more often in the multi-holed catheters.


Assuntos
Anestesia Epidural/instrumentação , Anestesia Obstétrica/instrumentação , Cateterismo/instrumentação , Anestesia Epidural/efeitos adversos , Cateterismo/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA