Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Skeletal Radiol ; 53(7): 1269-1278, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38206356

RESUMO

PURPOSE: To evaluate the distribution of intra- and extraarticular MRI findings in children and adolescents with clinically suspected intraarticular cause of hip pain in order to assess the need for additional intraarticular contrast administration. MATERIAL AND METHODS: Database was searched over a period of 34 months retrospectively for consecutive hip MR arthrography in young patients (8-17 years) with suspected intraarticular cause of hip or groin pain. Exclusion criteria were prior hip surgery, follow-up examination due to known intraarticular pathology, incomplete examination, qualitatively non-diagnostic examinations, and missing informed consent. Reports of fellowship-trained MSK radiologists were searched for intraarticular versus extraarticular findings explaining hip or groin pain. RESULTS: Seventy patients (68% female; median age: 14.5 years; range:10.8-16.9 years) were analyzed. No reason for pain was found in 30 (42.9%) hips, extraarticular reasons in 20 (28.6%) cases, intraarticular in 14 (20.0%), and both (intra- and extraarticular) in 6 (8.6%) hips. Most common extraarticular reasons were apophysitis (14.3%), other bony stress reactions (12.9%), intramuscular edema (7%), tendinitis (5.7%), and trochanteric bursitis (4.3%). Labral pathology was the most common intraarticular finding (overall:34.3%; partial tear:15.7%, complete tear:15.7%), most frequent at the anterosuperior position (81.8%). Cartilage defects (1.4%), intraarticular neoplasia (1.4%), and tear of the femoral head ligament (2.8%) were rarely found. Synovitis and loose bodies were not observed. Cam-(37.1%) and pincer-configurations (47.1%) were common while hip dysplasia was rare (5.7%). CONCLUSION: MRI in children and adolescents with hip pain should be done primarily without intraarticular contrast administration since most cases show an extraarticular pain reason or no diagnosis detectable with MRI.


Assuntos
Artralgia , Meios de Contraste , Articulação do Quadril , Imageamento por Ressonância Magnética , Humanos , Adolescente , Feminino , Masculino , Criança , Imageamento por Ressonância Magnética/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Artralgia/diagnóstico por imagem , Artralgia/etiologia , Reprodutibilidade dos Testes , Artrografia/métodos , Sensibilidade e Especificidade , Estudos Retrospectivos , Artropatias/diagnóstico por imagem
2.
J Neurosurg Spine ; 36(1): 113-124, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34479191

RESUMO

OBJECTIVE: The aim of this study was to compare the ability of 1) CT-derived bone lesion quality (classification of vertebral bone metastases [BM]) and 2) computed CT-measured volumetric bone mineral density (vBMD) for evaluating the strength and stiffness of cadaver vertebrae from donors with metastatic spinal disease. METHODS: Forty-five thoracic and lumbar vertebrae were obtained from cadaver spines of 11 donors with breast, esophageal, kidney, lung, or prostate cancer. Each vertebra was imaged using microCT (21.4 µm), vBMD, and bone volume to total volume were computed, and compressive strength and stiffness experimentally measured. The microCT images were reconstructed at 1-mm voxel size to simulate axial and sagittal clinical CT images. Five expert clinicians blindly classified the images according to bone lesion quality (osteolytic, osteoblastic, mixed, or healthy). Fleiss' kappa test was used to test agreement among 5 clinical raters for classifying bone lesion quality. Kruskal-Wallis ANOVA was used to test the difference in vertebral strength and stiffness based on bone lesion quality. Multivariable regression analysis was used to test the independent contribution of bone lesion quality, computed vBMD, age, gender, and race for predicting vertebral strength and stiffness. RESULTS: A low interrater agreement was found for bone lesion quality (κ = 0.19). Although the osteoblastic vertebrae showed significantly higher strength than osteolytic vertebrae (p = 0.0148), the multivariable analysis showed that bone lesion quality explained 19% of the variability in vertebral strength and 13% in vertebral stiffness. The computed vBMD explained 75% of vertebral strength (p < 0.0001) and 48% of stiffness (p < 0.0001) variability. The type of BM affected vBMD-based estimates of vertebral strength, explaining 75% of strength variability in osteoblastic vertebrae (R2 = 0.75, p < 0.0001) but only 41% in vertebrae with mixed bone metastasis (R2 = 0.41, p = 0.0168), and 39% in osteolytic vertebrae (R2 = 0.39, p = 0.0381). For vertebral stiffness, vBMD was only associated with that of osteoblastic vertebrae (R2 = 0.44, p = 0.0024). Age and race inconsistently affected the model's strength and stiffness predictions. CONCLUSIONS: Pathologic vertebral fracture occurs when the metastatic lesion degrades vertebral strength, rendering it unable to carry daily loads. This study demonstrated the limitation of qualitative clinical classification of bone lesion quality for predicting pathologic vertebral strength and stiffness. Computed CT-derived vBMD more reliably estimated vertebral strength and stiffness. Replacing the qualitative clinical classification with computed vBMD estimates may improve the prediction of vertebral fracture risk.


Assuntos
Densidade Óssea , Vértebras Lombares/diagnóstico por imagem , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/secundário , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Cadáver , Feminino , Humanos , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Vértebras Torácicas/patologia
3.
BMC Musculoskelet Disord ; 22(1): 849, 2021 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-34610804

RESUMO

BACKGROUND: For optimal prosthetic anchoring in omarthritis surgery, a differentiated knowledge on the mineralisation distribution of the glenoid is important. However, database on the mineralisation of diseased joints and potential relations with glenoid angles is limited. METHODS: Shoulder specimens from ten female and nine male body donors with an average age of 81.5 years were investigated. Using 3D-CT-multiplanar reconstruction, glenoid inclination and retroversion angles were measured, and osteoarthritis signs graded. Computed Tomography-Osteoabsorptiometry (CT-OAM) is an established method to determine the subchondral bone plate mineralisation, which has been demonstrated to serve as marker for the long-term loading history of joints. Based on mineralisation distribution mappings of healthy shoulder specimens, physiological and different CT-OAM patterns were compared with glenoid angles. RESULTS: Osteoarthritis grades were 0-I in 52.6% of the 3D-CT-scans, grades II-III in 34.3%, and grade IV in 13.2%, with in females twice as frequently (45%) higher grades (III, IV) than in males (22%, III). The average inclination angle was 8.4°. In glenoids with inclination ≤10°, mineralisation was predominantly centrally distributed and tended to shift more cranially when the inclination raised to > 10°. The average retroversion angle was - 5.2°. A dorsally enhanced mineralisation distribution was found in glenoids with versions from - 15.9° to + 1.7°. A predominantly centrally distributed mineralisation was accompanied by a narrower range of retroversion angles between - 10° to - 0.4°. CONCLUSIONS: This study is one of the first to combine CT-based analyses of glenoid angles and mineralisation distribution in an elderly population. The data set is limited to 19 individuals, however, indicates that superior inclination between 0° and 10°-15°, and dorsal version ranging between - 9° to - 3° may be predominantly associated with anterior and central mineralisation patterns previously classified as physiological for the shoulder joint. The current basic research findings may serve as basic data set for future studies addressing the glenoid geometry for treatment planning in omarthritis.


Assuntos
Corpo Humano , Articulação do Ombro , Idoso , Idoso de 80 Anos ou mais , Calcificação Fisiológica , Feminino , Humanos , Masculino , Escápula , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Bone ; 141: 115598, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32829037

RESUMO

INTRODUCTION: Pathologic vertebral fractures are a major clinical concern in the management of cancer patients with metastatic spine disease. These fractures are a direct consequence of the effect of bone metastases on the anatomy and structure of the vertebral bone. The goals of this study were twofold. First, we evaluated the effect of lytic, blastic and mixed (both lytic and blastic) metastases on the bone structure, on its material properties, and on the overall vertebral strength. Second, we tested the ability of bone mineral content (BMC) measurements and standard FE methodologies to predict the strength of real metastatic vertebral bodies. METHODS: Fifty-seven vertebral bodies from eleven cadaver spines containing lytic, blastic, and mixed metastatic lesions from donors with breast, esophageal, kidney, lung, or prostate cancer were scanned using micro-computed tomography (µCT). Based on radiographic review, twelve vertebrae were selected for nanoindentation testing, while the remaining forty-five vertebrae were used for assessing their compressive strength. The µCT reconstruction was exploited to measure the vertebral BMC and to establish two finite element models. 1) a micro finite element (µFE) model derived at an image resolution of 24.5 µm and 2) homogenized FE (hFE) model derived at a resolution of 0.98 mm. Statistical analyses were conducted to measure the effect of the bone metastases on BV/TV, indentation modulus (Eit), ratio of plastic/total work (WPl/Wtot), and in vitro vertebral strength (Fexp). The predictive value of BMC, µFE stiffness, and hFE strength were evaluated against the in vitro measurements. RESULTS: Blastic vertebral bodies exhibit significantly higher BV/TV compared to the mixed (p = 0.0205) and lytic (p = 0.0216) vertebral bodies. No significant differences were found between lytic and mixed vertebrae (p = 0.7584). Blastic bone tissue exhibited a 5.8% lower median Eit (p< 0.001) and a 3.3% lower median Wpl/Wtot (p<0.001) compared to non-involved bone tissue. No significant differences were measured between lytic and non-involved bone tissues. Fexp ranged from 1.9 to 13.8 kN, was strongly associated with hFE strength (R2=0.78, p< 0.001) and moderately associated with BMC (R2=0.66, p< 0.001) and µFE stiffness (R2=0.66, p< 0.001), independently of the lesion type. DISCUSSION: Our findings show that tumour-induced osteoblastic metastases lead to slightly, but significantly lower bone tissue properties compared to controls, while osteolytic lesions appear to have a negligible impact. These effects may be attributed to the lower mineralization and woven nature of bone forming in blastic lesions whilst the material properties of bone in osteolytic vertebrae appeared little changed. The moderate association between BMC- and FE-based predictions to fracture strength suggest that vertebral strength is affected by the changes of bone mass induced by the metastatic lesions, rather than altered tissue properties. In a broader context, standard hFE approaches generated from CTs at clinical resolution are robust to the lesion type when predicting vertebral strength. These findings open the door for the development of FE-based prediction tools that overcomes the limitations of BMC in accounting for shape and size of the metastatic lesions. Such tools may help clinicians to decide whether a patient needs the prophylactic fixation of an impending fracture.


Assuntos
Neoplasias , Coluna Vertebral , Fenômenos Biomecânicos , Densidade Óssea , Análise de Elementos Finitos , Humanos , Masculino , Coluna Vertebral/diagnóstico por imagem , Microtomografia por Raio-X
5.
Skeletal Radiol ; 48(5): 707-712, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30353278

RESUMO

OBJECTIVE: To test a 3D-hindfoot alignment (HA) measurement technique based on low-dose biplanar radiographs (BPRs) in a clinical setting and compare the results with 2D-HA measurements on long axial view radiographs (LARs). MATERIALS AND METHODS: This prospective study was approved by the local institutional review board. HA measurements on 3D-BPR and 2D-LAR of 50 patients (29 female; mean age 47 ± 16.6 years) were compared (positive values = valgus; negative values = varus). Two independent musculoskeletal radiologists (readers 1 and 2) performed 3D-HA measurements on BPR using a custom-made MATLAB code and measured HA on LAR during two separate readout sessions. Descriptive statistics and intraclass correlation coefficients (ICC) were calculated, and Bland-Altman plots were used for intermethod comparison. RESULTS: Using BPRs, HA was 0.8° ± 9.°1 (range, -20.2 to 20.0) for reader 1, and 0.7° ± 9.5° (range, -21.2 to 18.3) for reader 2. HA on LARs was -2.0 ° ± 7.0° (range, -27.0° to 11.1°) for reader 1 and - 1.7° ± 7.0° (range, -24.1° to 14.3°) for reader 2. Interreader agreement for measurements was excellent, both for BPRs (ICC = 0.992; 95% CI:0.986-0.995) and LAR measurements (ICC = 0.962; 95% CI:0.932-0.978). Mean difference between the two methods was -2.43° (range, -29.4° to 25.6°) for reader 1 and -2.6° (range,-28.7° to 30.2°) for reader 2. On Bland-Altman plots, three measurements of reader 1 and six measurements of reader 2 were outside of the ±1.96 SD interval. CONCLUSION: Hindfoot alignment measurements on 3D-BPR have an excellent interreader agreement in a clinical setting. Large measurement errors can occur in individual patients using 2D-LAR alone. Therefore, we suggest using 3D-BPR measurements in daily routine for the assessment of HA, which are independent of rotational foot malpositioning.


Assuntos
Pé/diagnóstico por imagem , Imageamento Tridimensional , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
AJR Am J Roentgenol ; 211(6): 1306-1312, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30247978

RESUMO

OBJECTIVE: The objective of our study was to compare MRI findings in the sacroiliac joints of postpartum women (as a model of mechanical changes) and women with known axial spondyloarthritis (as an inflammatory model). SUBJECTS AND METHODS: For this prospective multicenter age-matched, case-control study, sacroiliac joint MRI examinations of 30 healthy women (mean age, 34.0 years) in the early postpartum period (mechanical group) and 30 age-matched women (mean age, 33.8 years) with known axial spondyloarthritis (retrospective inflammatory group) were compared. Blinded to clinical information, readers assessed MR images using the following scoring systems: Spondyloarthritis Research Consortium of Canada (SPARCC) MRI index, Berlin method, Assessment of Spondyloarthritis International Society (ASAS) criteria, and SPARCC MRI structural score. Descriptive statistics as percentages of the different findings (i.e., bone marrow edema [BME], erosion, fatty bone marrow replacement, backfill, ankylosis) and scores between groups and between delivery modes were compared. RESULTS: In the postpartum group, 63.3% (19/30) of women showed BME around the sacroiliac joints compared with 86.7% (26/30) of women in the spondyloarthritis group (based on ASAS criteria). Erosions were uncommon in the postpartum group (10.0% [3/30] postpartum vs 56.7% [17/30] spondyloarthritis). Fatty bone marrow replacement, backfill, and ankylosis were not seen in the postpartum group. In subjects with positive MRI findings for sacroiliitis based on ASAS criteria, the SPARCC MRI index (mean ± SD, 13.6 ± 14.5 vs 13.0 ± 10.7; p = 0.818) and Berlin method (4.5 ± 3.0 and 5.5 ± 3.5, p = 0.378) were not different between the postpartum and spondyloarthritis groups. Scores were not different between birth modalities. CONCLUSION: Pregnancy-induced BME at the sacroiliac joints, as a result of prolonged mechanical stress, was present in 63.3% of women who underwent MRI during the early postpartum period and may mimic sacroiliitis of axial spondyloarthritis.


Assuntos
Edema/diagnóstico por imagem , Imageamento por Ressonância Magnética , Transtornos Puerperais/diagnóstico por imagem , Articulação Sacroilíaca , Sacroileíte/diagnóstico por imagem , Espondilartrite/diagnóstico por imagem , Adulto , Doenças da Medula Óssea , Estudos de Casos e Controles , Diagnóstico Diferencial , Feminino , Humanos , Estudos Prospectivos , Adulto Jovem
7.
Skeletal Radiol ; 47(2): 279-287, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29110050

RESUMO

OBJECTIVE: To describe the frequency of inflammatory-like findings on MR imaging in asymptomatic volunteers and compare them with patients with known rheumatoid arthritis and psoriatic arthritis. MATERIALS AND METHODS: MR images of fingers in 42 asymptomatic volunteers and 33 patients with rheumatoid/psoriatic arthritis were analyzed. The Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid/Psoriatic Arthritis MRI Scoring System (RAMRIS/PsAMRIS) and tenosynovitis scoring system were used to assess: bone marrow edema (BME), erosions, tendon sheath fluid/tenosynovitis, joint effusion, and soft-tissue edema. Findings and scores were compared between volunteers and patients. Inter-reader agreement was calculated (intraclass correlation coefficients, ICC). RESULTS: In volunteers, tendon sheath fluid was very common in at least one location (42/42 volunteers for reader 1, 34/42 volunteers for reader 2). BME, erosions, joint effusion, and soft-tissue edema were absent (except one BME in the 3rd proximal phalanx for reader 1). Tendon sheath fluid scores in volunteers and tenosynovitis scores in patients were high (reader 1, 7.17 and 5.39; reader 2, 2.31 and 5.45). Overall, inter-reader agreement was substantial (ICC = 0.696-0.844), except for tendon sheath fluid (ICC = 0.258). CONCLUSION: Fluid in the finger flexor tendon sheaths may be a normal finding and without gadolinium administration should not be interpreted as tenosynovitis. Bone marrow edema, erosions, joint effusion, and soft-tissue edema in the fingers most likely reflect pathology if present.


Assuntos
Artrite Psoriásica/diagnóstico por imagem , Artrite Reumatoide/diagnóstico por imagem , Dedos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tenossinovite/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Edema/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Inquéritos e Questionários
8.
Eur J Radiol ; 92: 153-158, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28624013

RESUMO

OBJECTIVE: To assess whether the use of cartilaginous contours at the femoral condyles instead of bony contours significantly changes femoral torsion measurements in children. MATERIALS AND METHODS: Femoral torsion was measured in 32 girls (mean age 10.1 years±2.3 standard deviation) and 42 boys (10.9 years±2.5) on axial magnetic resonance (MR) images by two independent readers (R1,R2). The femoral condyle angle was measured using each the cartilaginous and bony contours of the distal femur. Cartilage thickness at femoral condyles was assessed. Intraclass-correlation-coefficient (ICC) and Pearson's correlation were used for statistical analysis. RESULTS: Mean difference between cartilaginous and bony femoral torsion in girls was -1.1°±1.75 (range, -5.4° to 3.1°) for R1 and -1.64°±1.67 (-6.3° to 2.1°) for R2, in boys -1.5°±1.87 (-8.4° to 1.1°) for R1 and -2.28°±1.48 (-4.3° to 9.7°) for R2. Weak-to-moderate correlations between difference of cartilaginous-versus-bony measurements and cartilage thickness (r=-0.15 to -0.55, P<0.001-0.46) or age (r=-0.33 to 0.46, P<0.001-0.006) were found for both genders. Intermethod-ICC for cartilaginous versus bony femoral torsion measurements was 0.99/0.99 for R1/R2 in girls, and 0.99/0.98 in boys. CONCLUSION: There is only a small difference when measuring femoral torsion through cartilaginous versus bony contours, and no major difference in this between boys and girls.


Assuntos
Doenças Ósseas/patologia , Fêmur/patologia , Anormalidade Torcional/patologia , Adolescente , Articulação do Tornozelo/patologia , Criança , Feminino , Humanos , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Masculino
9.
Clin Anat ; 30(5): 591-598, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28295578

RESUMO

To quantify acetabular version using 3 D reconstructions based on biplanar radiographs (BPR) with CT as reference standard. No institutional review board approval was needed. Nine dry-bone pelvises underwent BPR in five different positions (rotation/tilt). The 3 D models of each pelvis were reconstructed by two radiologists on the basis of anatomical landmarks using semi-automated software. Automated software was used to assess the 3 D models and to calculate acetabular versions perpendicular to the anterior pelvic plane on all levels in the craniocaudal direction in 1 mm steps. Transverse CT images perpendicular to the anterior pelvic plain were reconstructed through the acetabulum in 1 mm steps. Both readers measured acetabular version on each image. Inter-reader agreement was calculated. Measurements based on BPR and CT were compared. Inter-reader agreement was almost perfect for BPR-based acetabular version measurements (ICC (intraclass correlation coefficient) = 0.920, P < 0.0005) and CT (ICC = 0.990, P < 0.0005). Correlation of acetabular versions between the five BPR-positions was substantial/almost perfect (ICC = 0.722-0.887 and 0.749-0.872 for readers 1 and 2, respectively; most P < 0.0005). The acetabular version measurements between the ap-positioning from BPR and CT showed moderate agreement (mean CCC (concordance correlation coefficient) = 0.733 for reader 1, CCC = 0.755 for reader 2). Acetabular version on multiple levels can be measured using BPR and dedicated post-processing software and is relatively independent of pelvic rotation and tilt. Clin. Anat. 30:591-598, 2017. © 2017 Wiley Periodicals, Inc.


Assuntos
Acetábulo/diagnóstico por imagem , Impacto Femoroacetabular/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Masculino , Padrões de Referência , Tomografia Computadorizada por Raios X
10.
Skeletal Radiol ; 46(4): 469-476, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28154901

RESUMO

OBJECTIVE: The aim of our study was to evaluate the reliability and interchangeability of femoral (FT) and tibial torsion (TT) measurements in children using magnetic resonance (MR) imaging compared to measurements on 3D models based on biplanar radiographs (BPR). MATERIALS AND METHODS: FT and TT were measured in 60 children (mean age 10.1 years; range 6.2-16.2 years; 28 female) using axial MR images by two readers. MR measurements were compared to measurements based on BPR-3D models by two separate independent readers. Interreader and intermethod agreements were calculated using descriptive statistics, the intraclass correlation coefficient (ICC), and Bland-Altman analysis. RESULTS: FT/TT was -8.4°-54.1°/0°-45.9° on MR images and -13°-63°/4°-52° for measurements on BPR-3D models. The median of difference between the two methods was -0.18° (range -13.6°-19.1°) for FT and -0.20° (range -18.4°-9.5°) for TT, respectively. Interreader agreement (ICC) of FT/TT measurements was 0.98/0.96 on MR images and 0.98/0.94 on BPR 3D models. Intermethod agreement (ICC) for MR measurements was 0.95 [95% confidence interval (CI), 0.93-0.96] for FT and of 0.86 (CI, 0.24-0.95) for TT. Mean interreader differences at MR were 3.1° (0.0°-8.0°) for FT and 3.2° (0.1°-9.5°) for TT. On Bland-Altman plots all measurements were within the 95% limit of agreement (-10.8°; 11.5° for FT; -14.6°; 4.2°) for TT-except for five measurements of FT and six measurements of TT. CONCLUSION: FT measurements on MR images are comparable to measurements using BPR-3D models. TT measurements differ between the two modalities, but the discrepancy is comparable to measurement variations between CT and BPR.


Assuntos
Doenças Ósseas/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Radiografia/métodos , Tíbia/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , Adolescente , Criança , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
BMC Musculoskelet Disord ; 18(1): 9, 2017 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-28068966

RESUMO

BACKGROUND: Placement of the glenoid baseplate is of paramount importance for the outcome of anatomical and reverse total shoulder arthroplasty. However, the database around glenoid size is poor, particularly regarding small scapulae, for example, in women and smaller individuals, and is derived from different methodological approaches. In this multimodality cadaver study, we systematically examined the glenoid using morphological and 3D-CT measurements. METHODS: Measurements of the glenoid and drill hole tunnel length for superior baseplate screw placement were recorded to define size of the glenoid and the distance to the scapular notch on cadaveric specimens. Glenoid angles were determined on both, 3D-CT-scans of the thoraxes using the Friedman method and on subsequently isolated scapulae from 18 male and female donors (average 84 years, range 60-98 years). RESULTS: Mean glenoid height was 36.6 mm ± 3.6, and width 27.8 mm ± 3.1 with a significant sex dimorphism (p ≤ 0.001): in males, glenoid height 39.5 mm ± 3.5, and width 30.3 mm ± 3.3, and in females, glenoid height 34.8 mm ± 2.2, and width 26.2 mm ± 1.6. The average distance from the superior screw entry to its exit in the scapular notch measured by calliper was 27.2 mm ± 6.0 with a sex difference: in males, 29.4 mm ± 5.7, and in females, 25.8 mm ± 5.9 mm with a minimum recorded distance of 15 mm. Measured by CT, the mean inclination angle for male and female donors combined was 13.0° ± 7.0, and the ante-/retroversion angle -1.0° ± 4.0°. CONCLUSION: This study is one of the first to combine dissection, including drill holes, with anatomical measurements and radiological data. In some women and smaller individuals, smaller baseplates should be selected. The published safe zone of 20 mm is generally feasible for superior screw placement, however, in small patients this distance may be substantially shorter than expected and start as of 13 and 15 mm, respectively. No correlation between glenoid height or width with the length of our drilling canal towards the scapular notch was found. Preoperative CT-based treatment planning to determine version and inclination angles is recommended.


Assuntos
Artroplastia do Ombro/métodos , Dissecação/métodos , Cavidade Glenoide/anatomia & histologia , Cavidade Glenoide/diagnóstico por imagem , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Cavidade Glenoide/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/patologia
12.
Knee Surg Sports Traumatol Arthrosc ; 25(3): 853-862, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26537597

RESUMO

PURPOSE: To prospectively compare patellofemoral and tibiofemoral articulations in the upright weight-bearing position with different degrees of flexion using CT in order to gain a more thorough understanding of the development of diseases of the knee joint in a physiological position. MATERIALS AND METHODS: CT scans of the knee in 0°, 30°, 60° flexion in the upright weight-bearing position and in 120° flexion upright without weight-bearing were obtained of 10 volunteers (mean age 33.7 ± 6.1 years; range 24-41) using a cone-beam extremity-CT. Two independent readers quantified tibiofemoral and patellofemoral rotation, tibial tuberosity-trochlear groove distance (TTTG) and patellofemoral distance. Tibiofemoral contact points were assessed in relation to the anteroposterior distance of the tibial plateau. Significant differences between degrees of flexion were sought using Wilcoxon signed-rank test (P < 0.05). RESULTS: With higher degrees of flexion, internal tibiofemoral rotation increased (0°/120° flexion; mean, 0.5° ± 4.5/22.4° ± 7.6); external patellofemoral rotation decreased (10.6° ± 7.6/1.6° ± 4.2); TTTG decreased (11.1 mm ±3.7/-2.4 mm ±6.4) and patellofemoral distance decreased (38.7 mm ±3.0/21.0 mm ±7.0). The CP shifted posterior, more pronounced laterally. Significant differences were found for all measurements at all degrees of flexion (P = 0.005-0.037), except between 30° and 60°. ICC was almost perfect (0.80-0.99), except for the assessment of the CP (0.20-0.96). CONCLUSION: Knee joint articulations change significantly during flexion using upright weight-bearing CT. Progressive internal tibiofemoral rotation leads to a decrease in the TTTG and a posterior shift of the contact points in higher degrees of flexion. This elucidates patellar malalignment predominantly close to extension and meniscal tears commonly affecting the posterior horns.


Assuntos
Patela/fisiologia , Amplitude de Movimento Articular/fisiologia , Tomografia Computadorizada por Raios X , Suporte de Carga/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Joelho , Traumatismos do Joelho , Articulação do Joelho/fisiologia , Masculino , Estudos Prospectivos , Rotação , Tíbia/fisiologia , Tomografia Computadorizada por Raios X/instrumentação , Adulto Jovem
13.
Acta Radiol ; 58(5): 581-585, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27516606

RESUMO

Background Magnetic resonance imaging (MRI) is the diagnostic modality of choice in defining soft tissue compromise of the spinal canal. Purpose To evaluate the reliability of postoperative MRI in the determination of level and side of lumbar spinal decompression surgery, investigated by two reviewers, in different levels of training and specialization. Material and Methods Postoperative MR images of 86 patients who underwent spinal decompression (single level, n = 70; multilevel, n = 16; revision decompression, n = 9) were reviewed independently by an experienced musculoskeletal radiologist and a fourth-year orthopedic surgery resident. The level (single or multiple) and side of previous surgical decompression were determined and compared to the surgical notes. We examined factors that may have influenced the reliability, including demographics, type of surgical decompression, use of a drain, and time interval from surgery to MRI. Results Significantly fewer levels were correctly determined by the resident (77/86 cases, 89.5%) compared with the radiologist (84/86 cases, 97.7%) ( P = 0.014). The resident interpreted significantly more MR images incorrectly in cases where a drain was used (n = 8; P < 0.001). Re-decompression cases were interpreted incorrectly significantly more often by both the radiologist (n = 2, P = 0.032) and the resident (n = 4, P = 0.014). Conclusion Determination of the level and side operated on in previous lumbar spinal decompression surgery on MRI has a high reliability, especially when performed by a musculoskeletal radiologist. However, this reliability is decreased in cases involving surgical drainage and same-level revision surgery.


Assuntos
Descompressão Cirúrgica/métodos , Imageamento por Ressonância Magnética/métodos , Cuidados Pós-Operatórios/métodos , Reoperação/métodos , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Canal Medular/cirurgia , Resultado do Tratamento
14.
AJR Am J Roentgenol ; 208(2): 402-412, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27845853

RESUMO

OBJECTIVE: The objective of our study was to assess delayed-onset muscle soreness (DOMS) over time using quantitative MRI and shear-wave ultrasound (US) elastography. SUBJECTS AND METHODS: Five male (mean age ± SD, 39.6 ± 4.6 years) and five female (30.6 ± 13.5 years) volunteers underwent 1.5-T MRI before and after (15 minutes, 1 day, 3 days, 7 days) performing unilateral eccentric resistance exercise of the elbow flexor muscles. The MRI examinations included fluid-sensitive, DWI, and diffusion-tensor imaging sequences of the distal upper arm. Muscle edema, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) were assessed. US of the brachialis muscle was performed before and after (15 minutes, 12 hours, 1 day, 2 days, 3 days, 7 days) exercise to measure mean shear-wave velocity (SWV). Pain and muscle tightness were assessed. RESULTS: For men, muscle edema was moderate and peaked 3 days after exercise; for women, muscle edema was mild and peaked 1-3 days after exercise. ADC was highest 3 days after exercise in men (mean, 1809.22 × 10-6 mm2/s; before exercise, 1529.88 × 10-6 mm2/s) and women (1741.90 × 10-6 mm2/s; before exercise, 1475.80 × 10-6 mm2/s). FA dropped from 361.00 in men and 389.00 in women before exercise to a minimum of 252.12 and 321.28, respectively, 3 days after exercise. Mean SWV increased after exercise in men (before exercise, 3.00 ± 0.30 m/s; peak [15 minutes after exercise], 4.04 ± 0.90 m/s) and women (before, 2.82 ± 0.40 m/s; peak [1 day after exercise], 3.23 ± 0.40 m/s) and subsequently returned to normal. In men, the ADC values of the brachialis muscle positively correlated with mean SWV (r = 0.92, p = 0.028). FA negatively correlated with pain in men (r = -0.993, p = 0.001) Muscle edema outlasted clinical symptoms in most volunteers. CONCLUSION: FA inversely correlates with pain and may be a useful imaging parameter for assessment of DOMS. Shear-wave US elastography shows a temporary increase of muscle stiffness after DOMS-inducing exercise but does not correlate with quantitative MRI parameters or clinical symptoms.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Mialgia/diagnóstico por imagem , Mialgia/fisiopatologia , Adulto , Módulo de Elasticidade , Feminino , Humanos , Estudos Longitudinais , Masculino , Músculo Esquelético/patologia , Mialgia/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Estresse Mecânico , Adulto Jovem
15.
Skeletal Radiol ; 45(11): 1541-51, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27631078

RESUMO

OBJECTIVE: The purpose of this study is to compare the reliability of SW velocity measurements of two different ultrasound systems and their correlation with the tangent traction modulus in a non-static tendon strain model. MATERIALS AND METHODS: A bovine tendon was fixed in a custom-made stretching device. Force was applied increasing from 0 up to 18 Newton. During each strain state the tangent traction modulus was determined by the stretcher device, and SW velocity (m/s) measurements using a Siemens S3000 and a Supersonic Aixplorer US machine were done for shear modulus (kPa) calculation. RESULTS: A strong significant positive correlation was found between SW velocity assessed by the two ultrasound systems and the tangent traction modulus (r = 0.827-0.954, p < 0.001), yet all SW velocity-based calculations underestimated the reference tissue tangent modulus. Mean difference of SW velocities with the S3000 was 0.44 ± 0.3 m/s (p = 0.002) and with the Aixplorer 0.25 ± 0.3 m/s (p = 0.034). Mean difference of SW velocity between the two US-systems was 0.37 ± 0.3 m/s (p = 0.012). CONCLUSION: In conclusion, SW velocities are highly dependent on mechanical forces in the tendon tissue, but for controlled mechanical loads appear to yield reproducible and comparable measurements using different US systems.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imagens de Fantasmas , Tendões/diagnóstico por imagem , Tendões/fisiologia , Animais , Bovinos , Módulo de Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento/fisiologia , Estresse Mecânico , Resistência à Tração/fisiologia
16.
Radiology ; 280(2): 351-69, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27429142

RESUMO

Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.


Assuntos
Atletas , Traumatismos em Atletas/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Articulação do Quadril/diagnóstico por imagem , Humanos
17.
Eur Spine J ; 25(11): 3658-3665, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27206516

RESUMO

PURPOSE: Wearing high heels is associated with chronic pain of the neck, lower back and knees. The mechanisms behind this have not been fully understood. The purpose of this study was to investigate the influence of high-heeled shoes on the sagittal balance of the spine and the whole body in non-habitual wearers of high heels. METHODS: Lateral standing whole body low-dose radiographs were obtained from 23 female participants (age 29 ± 6 years) with and without high heels and radiological parameters describing the sagittal balance were quantified. These were analyzed for differences between both conditions in the total sample and in subgroups. RESULTS: Standing in high heels was associated with an increased femoral obliquity angle [difference (Δ) 3.0° ± 1.7°, p < 0.0001], and increased knee (Δ 2.4° ± 2.9°, p = 0.0009) and ankle flexion (Δ 38.7° ± 3.4°, p < 0.0001). The differences in C7 and meatus vertical axis, cervical and lumbar lordosis, thoracic kyphosis, spino-sacral angle, pelvic tilt, sacral slope, and spinal tilt were not significant. Individuals adapting with less-than-average knee flexion responded to high heels by an additional increase in cervical lordosis (Δ 5.8° ± 10.7° vs. 1.8° ± 5.3°). CONCLUSIONS: In all participants, wearing high heels led to increased flexion of the knees and to more ankle flexion. While some participants responded to high heels primarily through the lower extremities, others used increased cervical lordosis to adapt to the shift of the body's center of gravity. This could explain the different patterns of pain in the neck, lower back and knees seen in individuals wearing high heels frequently.


Assuntos
Equilíbrio Postural , Sapatos/efeitos adversos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/fisiopatologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/patologia , Extremidade Inferior/fisiopatologia , Postura , Radiografia , Coluna Vertebral/patologia
18.
Eur Radiol ; 26(9): 3054-62, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26738507

RESUMO

OBJECTIVE: To evaluate reliability of 2D and 3D lower limb measurements in adults using micro-dose compared to low-dose biplanar radiographs(BPR). MATERIALS AND METHODS: One hundred patients (mean 54.9 years) were examined twice using micro-dose and low-dose BPR. Length and mechanical axis of lower limbs were measured on the antero-posterior(ap) micro-dose and low-dose images by two independent readers. Femoral and tibial torsions of 50 patients were measured by two independent readers using reconstructed 3D-models based on the micro-dose and low-dose BPR. Intermethod and interreader agreements were calculated using descriptive statistics, intraclass-correlation-coefficient(ICC), and Bland-Altman analysis. RESULTS: Mean interreader-differences on micro-dose were 0.3 cm(range 0-1.0)/ 0.7°(0-2.9) for limb length/axis and 0.4 cm (0-1.0)/0.8°(0-3.3) on low-dose BPR. Mean intermethod-difference was 0.04 cm ± 0.2/0.04° ± 0.6 for limb length/axis. Interreader-ICC for limb length/axis was 0.999/0.991 on micro-dose and 0.999/0.987 on low-dose BPR. Interreader-ICC for micro-dose was 0.879/0.826 for femoral/ tibial torsion, for low-dose BPR was 0.924/0.909. Mean interreader-differences on micro-dose/low-dose BPR were 3°(0-13°)/2°(0°-12°) for femoral and 4°(0-18°)/3°(0°-10°) for tibial torsion. Mean intermethod-difference was -0.1° ± 5.0/-0.4° ± 2.9 for femoral/tibial torsion. Mean dose-area-product was significantly lower (9.9 times;p < 0.001) for micro-dose BPR. CONCLUSION: 2D-and 3D-measurements of lower limbs based on micro-dose BPR are reliable and provide a 10-times lower radiation dose. KEY POINTS: • Lower limb length and mechanical axis can be reliably measured with micro-dose. • Femoral and tibial torsion can be reliably assessed with micro-dose. • Micro-dose allows a huge reduction of radiation exposure.


Assuntos
Fêmur/anatomia & histologia , Tíbia/anatomia & histologia , Adulto , Idoso , Relação Dose-Resposta à Radiação , Feminino , Fêmur/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Extremidade Inferior/anatomia & histologia , Extremidade Inferior/diagnóstico por imagem , Masculino , Pelve , Doses de Radiação , Exposição à Radiação , Radiografia , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
19.
Acta Radiol ; 57(8): 971-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26508794

RESUMO

BACKGROUND: The coracoacromial ligament is part of the coracoacromial arch, which is considered to be involved in shoulder impingement. PURPOSE: To compare the coracoacromial ligament on ultrasound in asymptomatic volunteers and in patients with subacromial shoulder impingement. MATERIAL AND METHODS: Twenty-nine asymptomatic volunteers (mean age, 35.5 years) and 29 patients (mean age, 49.9 years) with shoulder impingement, diagnosed by experienced shoulder surgeons, were prospectively included. Two radiologists obtained and analyzed ultrasound images of the coracoacromial ligament in the longitudinal axis. RESULTS: The ligament thickness was 1.4 ± 0.2 mm at its midportion, 1.8 ± 0.4 mm at the coracoid, and 2.1 ± 0.6 mm at the acromion in asymptomatic volunteers compared with 1.3 ± 0.2 mm, 1.9 ± 0.5 mm, and 1.9 ± 0.5 mm in impingement patients for observer 1. The ligament length was 30.6 ± 2.4 mm in asymptomatic volunteers compared with 30.4 ± 3.6 mm in impingement patients for observer 1. An anteriorly convex shape of the superficial contour of the coracoacromial ligament was significantly more frequent in impingement patients compared with asymptomatic volunteers for both observers (observer 1: 10% (3/29) versus 45% (13/29), P value <0.01; observer 2: 10% (3/29) versus 38% (11/29), P value <0.03). The comparison of the remaining parameters of the coracoacromial ligament, such as the thickness, length, echogenicity, and fibrillation did not reveal significant differences between volunteers and patients. CONCLUSION: While thickness or length of the coracoacromial ligament were similar in volunteers and patients with shoulder impingement, an anteriorly convex shape of the superficial contour of the coracoacromial ligament was significantly more frequent in impingement patients compared with asymptomatic volunteers.


Assuntos
Articulação Acromioclavicular/diagnóstico por imagem , Ligamentos Articulares/diagnóstico por imagem , Síndrome de Colisão do Ombro/diagnóstico por imagem , Ultrassonografia/métodos , Articulação Acromioclavicular/fisiologia , Articulação Acromioclavicular/fisiopatologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Ligamentos Articulares/fisiologia , Ligamentos Articulares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Síndrome de Colisão do Ombro/fisiopatologia
20.
Radiology ; 278(2): 465-74, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26540450

RESUMO

PURPOSE: To evaluate the reliability of ultrasonographic (US) elastography of the supraspinatus (SSP) muscle, define normal shear-wave velocity (SWV) values, and correlate findings with tendon integrity and muscle quality. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained from all patients. SSP SWV (in meters per second) was prospectively assessed twice in 22 asymptomatic volunteers (mean age ± standard deviation, 53.8 years ± 15.3; 11 women and 11 men) by two independent examiners by using shear-wave elastography. Forty-four patients (mean age, 51.9 years ± 15.0; 22 women and 22 men) were prospectively included. SWV findings were compared with tendon integrity, tendon retraction (Patte classification), fatty muscle infiltration (Goutallier stages 0-IV), and muscle volume atrophy (tangent sign) on magnetic resonance (MR) images. Descriptive statistics, Spearman correlation, analysis of variance, two-sample t test, and intraclass correlation coefficient (ICC) were used. RESULTS: Test-retest reliability for mean total SWV (MTSWV) was good for examiner 1 (ICC = 0.70; 95% confidence interval [CI]: 0.30, 0.87; P = .003) and excellent for examiner 2 (ICC = 0.80; 95% CI: 0.53, 0.92; P < .001). Interexaminer reliability was excellent (ICC = 0.89; 95% CI: 0.64, 0.96; P < .001). MTSWV in volunteers (3.0 m/sec ± 0.5) was significantly higher than that in patients (2.5 m/sec ± 0.5; P = .001). For tendon integrity, no significant difference in MTSWV was found. For tendon retraction, MTSWV varies significantly between patients with different degrees of retraction (P = .047). No significant differences were found for Goutallier subgroups. MTSWV was significantly lower with a positive tangent sign (P = .015; n = 10). CONCLUSION: Shear-wave elastography is reproducible for assessment of the SSP muscle. Mean normal SSP SWV is 3.0 m/sec ± 0.5. SWV decreases with increasing fat content (Goutallier stage 0-III) and increases in the final stage of fatty infiltration (Goutallier stage IV).


Assuntos
Técnicas de Imagem por Elasticidade , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/patologia , Manguito Rotador/patologia , Tendinopatia/diagnóstico , Tecido Adiposo/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...