Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 710
Filtrar
1.
medRxiv ; 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38712176

RESUMO

Background: Recent data have demonstrated that in locally advanced rectal cancer (LARC), a total neoadjuvant therapy (TNT) approach improves compliance with chemotherapy and increases rates of tumor response compared to neoadjuvant chemoradiation (CRT) alone. They further indicate that the optimal sequencing of TNT involves consolidation (rather than induction) chemotherapy to optimize complete response rates. Data, largely from retrospective studies, have also shown that patients with clinical complete response (cCR) after neoadjuvant therapy may be managed safely with the watch and wait approach (WW) instead of preemptive total mesorectal resection (TME). However, the optimal consolidation chemotherapy regimen to achieve cCR has not been established, and a randomized clinical trial has not robustly evaluated cCR as a primary endpoint. Collaborating with a multidisciplinary oncology team and patient groups, we designed this NCI-sponsored study of chemotherapy intensification to address these issues and to drive up cCR rates, to provide opportunity for organ preservation, improve quality of life for patients and improve survival outcomes. Methods: In this NCI-sponsored multi-group randomized, seamless phase II/III trial (1:1), up to 760 patients with LARC, T4N0, any T with node positive disease (any T, N+) or T3N0 requiring abdominoperineal resection or coloanal anastomosis and distal margin within 12 cm of anal verge will be enrolled. Stratification factors include tumor stage (T4 vs T1-3), nodal stage (N+ vs N0) and distance from anal verge (0-4; 4-8; 8-12 cm). Patients will be randomized to receive neoadjuvant long course chemoradiation (LCRT) followed by consolidation doublet (mFOLFOX6 or CAPOX) or triplet chemotherapy (mFOLFIRINOX) for 3-4 months. LCRT in both arms involves 4500 cGy in 25 fractions over 5 weeks + 900 cGy boost in 5 fractions with a fluoropyrimidine (capecitabine preferred). Patients will undergo assessment 8-12 (+/- 4) weeks post-TNT completion. The primary endpoint for the phase II portion will compare cCR between treatment arms. A total number of 296 evaluable patients (148 per arm) will provide statistical power of 90.5% to detect an 17% increase in cCR rate, at a one-sided alpha=0.048. The primary endpoint for the phase III portion will compare disease-free survival (DFS) between treatment arms. A total of 285 DFS events will provide 85% power to detect an effect size of hazard ratio 0.70 at a one-sided alpha of 0.025, requiring enrollment of 760 patients (380 per arm). Secondary objectives include time-to event outcomes (overall survival, organ preservation time and time to distant metastasis) and adverse effects. Biospecimens including archival tumor tissue, plasma and buffy coat in EDTA tubes, and serial rectal MRIs will be collected for exploratory correlative research. This study, activated in late 2022, is open across the NCTN and has a current accrual of 312. Support: U10CA180821, U10CA180882, U24 CA196171; https://acknowledgments.alliancefound.org . Discussion: Building off of data from modern day rectal cancer trials and patient input from national advocacy groups, we have designed the current trial studying chemotherapy intensification via a consolidation chemotherapy approach with the intent to enhance cCR and DFS rates, increase organ preservation rates, and improve quality of life for patients with rectal cancer. Trial Registration: Clinicaltrials.gov ID: NCT05610163 ; Support includes U10CA180868 (NRG) and U10CA180888 (SWOG).

2.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081262

RESUMO

We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion-photon couplings above 10-13 Ge V-1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7-4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

3.
Phys Rev Lett ; 131(19): 191001, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000434

RESUMO

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10^{5}), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from -3.15 to -3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

4.
Phys Rev Lett ; 131(10): 101002, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37739367

RESUMO

We report the first result of a direct search for a cosmic axion background (CaB)-a relativistic background of axions that is not dark matter-performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the CaB will be broad. We introduce a novel analysis strategy, which searches for a CaB induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a CaB originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband rf signals, such as other forms of a CaB or even high-frequency gravitational waves.

6.
Phys Rev Lett ; 131(4): 041002, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37566836

RESUMO

The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60 live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c^{2}. The most stringent limit is set for spin-independent scattering at 36 GeV/c^{2}, rejecting cross sections above 9.2×10^{-48} cm at the 90% confidence level.

7.
Sci Total Environ ; 900: 165673, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37481083

RESUMO

Hospital acquired infections stemming from contaminated reusable medical devices are of increasing concern. This issue is exaggerated with the introduction of complex medical devices like endoscopes and robotic instrumentation. Although medical device manufacturers validate their cleaning instructions for use, evidence in the literature demonstrates that effective device processing is not being performed consistently within sterile processing departments in clinical settings. The result is increased risks to patient safety. As a solution to this problem, focused one-on-one training increases compliance to the medical device manufacturer's processing instruction. However, often this is not a practical solution for the volume of healthcare staff responsible for device processing activities. This constitutes the first paper to address the blended use of educational and digital technologies to address these challenges and as a result inform safety and sustainability for the medical device sector. Cognitive learning theory is an evidence-based framework for learning. It supports the use of immersive educational experiences using emerging extended reality technologies (e.g., virtual or augmented reality) to increase learning comprehension. The delivery of educational content via these technologies provides an innovative option for repeatable leaning and training outcomes. The motivation is to decrease patient risk of contaminated reusable medical devices. The proposed approach while primary motivated by safety can also enhance sustainability and efficiency enabled by artificial intelligence and robotic instrumentation.


Assuntos
Inteligência Artificial , Segurança do Paciente , Humanos , Aprendizagem , Tecnologia Educacional
8.
Phys Rev Lett ; 130(21): 211001, 2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37295105

RESUMO

We present the observation of a charge-sign dependent solar modulation of galactic cosmic rays (GCRs) with the Calorimetric Electron Telescope onboard the International Space Station over 6 yr, corresponding to the positive polarity of the solar magnetic field. The observed variation of proton count rate is consistent with the neutron monitor count rate, validating our methods for determining the proton count rate. It is observed by the Calorimetric Electron Telescope that both GCR electron and proton count rates at the same average rigidity vary in anticorrelation with the tilt angle of the heliospheric current sheet, while the amplitude of the variation is significantly larger in the electron count rate than in the proton count rate. We show that this observed charge-sign dependence is reproduced by a numerical "drift model" of the GCR transport in the heliosphere. This is a clear signature of the drift effect on the long-term solar modulation observed with a single detector.


Assuntos
Radiação Cósmica , Voo Espacial , Telescópios , Prótons , Elétrons
9.
Phys Rev Lett ; 130(17): 171002, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37172251

RESUMO

We present the results of a direct measurement of the cosmic-ray helium spectrum with the CALET instrument in operation on the International Space Station since 2015. The observation period covered by this analysis spans from October 13, 2015, to April 30, 2022 (2392 days). The very wide dynamic range of CALET allowed for the collection of helium data over a large energy interval, from ∼40 GeV to ∼250 TeV, for the first time with a single instrument in low Earth orbit. The measured spectrum shows evidence of a deviation of the flux from a single power law by more than 8σ with a progressive spectral hardening from a few hundred GeV to a few tens of TeV. This result is consistent with the data reported by space instruments including PAMELA, AMS-02, and DAMPE and balloon instruments including CREAM. At higher energy we report the onset of a softening of the helium spectrum around 30 TeV (total kinetic energy). Though affected by large uncertainties in the highest energy bins, the observation of a flux reduction turns out to be consistent with the most recent results of DAMPE. A double broken power law is found to fit simultaneously both spectral features: the hardening (at lower energy) and the softening (at higher energy). A measurement of the proton to helium flux ratio in the energy range from 60 GeV/n to about 60 TeV/n is also presented, using the CALET proton flux recently updated with higher statistics.

10.
Phys Rev Lett ; 129(10): 101102, 2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36112450

RESUMO

A precise measurement of the cosmic-ray proton spectrum with the Calorimetric Electron Telescope (CALET) is presented in the energy interval from 50 GeV to 60 TeV, and the observation of a softening of the spectrum above 10 TeV is reported. The analysis is based on the data collected during ∼6.2 years of smooth operations aboard the International Space Station and covers a broader energy range with respect to the previous proton flux measurement by CALET, with an increase of the available statistics by a factor of ∼2.2. Above a few hundred GeV we confirm our previous observation of a progressive spectral hardening with a higher significance (more than 20 sigma). In the multi-TeV region we observe a second spectral feature with a softening around 10 TeV and a spectral index change from -2.6 to -2.9 consistently, within the errors, with the shape of the spectrum reported by DAMPE. We apply a simultaneous fit of the proton differential spectrum which well reproduces the gradual change of the spectral index encompassing the lower energy power-law regime and the two spectral features observed at higher energies.

11.
Gait Posture ; 98: 153-159, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36126535

RESUMO

BACKGROUND: Individuals with lower-limb amputation can use running specific prostheses (RSP) that store and then return elastic energy during stance. However, it is unclear whether varying the stiffness category of the same RSP affects spring-mass behaviour during self-selected, submaximal speed running in individuals with unilateral transtibial amputation. RESEARCH QUESTION: The current study investigates how varying RSP stiffness affects limb stiffness, running performance, and associated joint kinetics in individuals with a unilateral transtibial amputation. METHODS: Kinematic and ground reaction force data were collected from eight males with unilateral transtibial amputation who ran at self-selected submaximal speeds along a 15 m runway in three RSP stiffness conditions; recommended habitual stiffness (HAB) and, following 10-minutes of familiarisation, stiffness categories above (+1) and below (-1) the HAB. Stance-phase centre of mass velocity, contact time, limb stiffness' and joint/RSP work were computed for each limb across RSP stiffness conditions. RESULTS: With increased RSP stiffness, prosthetic limb stiffness increased, whilst intact limb stiffness decreased slightly (p<0.03). Centre of mass forward velocity during stance-phase (p<0.02) and contact time (p<0.04) were higher in the intact limb and lower in the prosthetic limb but were unaffected by RSP stiffness. Intact limb hip joint positive work increased for both the +1 and -1 conditions but remained unchanged across conditions in the prosthetic limb (p<0.02). SIGNIFICANCE: In response to changes in RSP stiffness, there were acute increased mechanical demands on the intact limb, reflecting a reliance on the intact limb during running. However, overall running speed was unaffected, suggesting participants acutely adapted to an RSP of a non-prescribed stiffness.


Assuntos
Amputados , Membros Artificiais , Corrida , Masculino , Humanos , Comportamento de Massa , Corrida/fisiologia , Amputação Cirúrgica , Fenômenos Biomecânicos
12.
Phys Rev Lett ; 128(13): 131103, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35426700

RESUMO

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ∼3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The particle's energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [1O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).PRLTAO0031-900710.1103/PhysRevLett.126.241101], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51±0.07.

13.
Phys Rev Lett ; 129(25): 251103, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36608255

RESUMO

We present the measurement of the energy dependence of the boron flux in cosmic rays and its ratio to the carbon flux in an energy interval from 8.4 GeV/n to 3.8 TeV/n based on the data collected by the Calorimetric Electron Telescope (CALET) during ∼6.4 yr of operation on the International Space Station. An update of the energy spectrum of carbon is also presented with an increase in statistics over our previous measurement. The observed boron flux shows a spectral hardening at the same transition energy E_{0}∼200 GeV/n of the C spectrum, though B and C fluxes have different energy dependences. The spectral index of the B spectrum is found to be γ=-3.047±0.024 in the interval 25

14.
BMJ Open ; 11(12): e052091, 2021 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-34862289

RESUMO

INTRODUCTION: Achieving optimal diabetes control requires several daily self-management behaviours, especially adherence to medication. Evidence supports the use of text messages to support adherence, but there remains much opportunity to improve their effectiveness. One key limitation is that message content has been generic. By contrast, reinforcement learning is a machine learning method that can be used to identify individuals' patterns of responsiveness by observing their response to cues and then optimising them accordingly. Despite its demonstrated benefits outside of healthcare, its application to tailoring communication for patients has received limited attention. The objective of this trial is to test the impact of a reinforcement learning-based text messaging programme on adherence to medication for patients with type 2 diabetes. METHODS AND ANALYSIS: In the REinforcement learning to Improve Non-adherence For diabetes treatments by Optimising Response and Customising Engagement (REINFORCE) trial, we are randomising 60 patients with suboptimal diabetes control treated with oral diabetes medications to receive a reinforcement learning intervention or control. Subjects in both arms will receive electronic pill bottles to use, and those in the intervention arm will receive up to daily text messages. The messages will be individually adapted using a reinforcement learning prediction algorithm based on daily adherence measurements from the pill bottles. The trial's primary outcome is average adherence to medication over the 6-month follow-up period. Secondary outcomes include diabetes control, measured by glycated haemoglobin A1c, and self-reported adherence. In sum, the REINFORCE trial will evaluate the effect of personalising the framing of text messages for patients to support medication adherence and provide insight into how this could be adapted at scale to improve other self-management interventions. ETHICS AND DISSEMINATION: This study was approved by the Mass General Brigham Institutional Review Board (IRB) (USA). Findings will be disseminated through peer-reviewed journals, clinicaltrials.gov reporting and conferences. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov (NCT04473326).


Assuntos
Diabetes Mellitus Tipo 2 , Autogestão , Envio de Mensagens de Texto , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas , Humanos , Adesão à Medicação , Ensaios Clínicos Pragmáticos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
Phys Rev Lett ; 126(24): 241101, 2021 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-34213922

RESUMO

The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray iron over a wide energy interval. In this Letter a measurement of the iron spectrum is presented in the range of kinetic energy per nucleon from 10 GeV/n to 2.0 TeV/n allowing the inclusion of iron in the list of elements studied with unprecedented precision by space-borne instruments. The measurement is based on observations carried out from January 2016 to May 2020. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The energy is measured by a homogeneous calorimeter with a total equivalent thickness of 1.2 proton interaction lengths preceded by a thin (3 radiation lengths) imaging section providing tracking and energy sampling. The analysis of the data and the detailed assessment of systematic uncertainties are described and results are compared with the findings of previous experiments. The observed differential spectrum is consistent within the errors with previous experiments. In the region from 50 GeV/n to 2 TeV/n our present data are compatible with a single power law with spectral index -2.60±0.03.

16.
Urology ; 152: 117-122, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33556448

RESUMO

OBJECTIVE: To evaluate the outcomes of excision and primary anastomosis (EPA) for radiation-associated bulbomembranous stenoses using a multi-institutional analysis. The treatment of radiation-associated urethral stenosis is typically complex owing to the adverse impact of radiation on adjacent tissue. METHODS: An IRB-approved multi-institutional retrospective review was performed on patients who underwent EPA for bulbomembranous urethral stenosis following prostate radiotherapy. Preoperative patient demographics, operative technique, and postoperative outcomes were abstracted from 1/2007-6/2018. Success was defined as voiding per urethra without the need for endoscopic treatment and a minimum follow-up of 12 months. RESULTS: One hundred and thirty-seven patients from 10 centers met study criteria with a mean age of 69.3 years (50-86), stenosis length of 2.3 cm (1-5) and an 86.9% (119/137) success rate at a mean follow-up 32.3 months (12-118). Univariate Cox regression analysis identified increasing patient age (P = .02), stricture length (P <.0001) and combined modality radiotherapy (P = .004) as factors associated with stricture recurrence while body mass index (P = .79), diabetes (P = .93), smoking (P = .62), failed endoscopic treatment (P = .08) and gracilis muscle use (P = .25) were not. On multivariate analysis, increasing patient age (H.R.1.09, 95%CI 1.01-1.16; P = .02) and stenosis length (H.R.2.62, 95%CI 1.49-4.60; P = .001) remained associated with recurrence. Subsequent artificial urinary sphincter was performed in 30 men (21.9%), of which 25 required a transcorporal cuff and 5 developed cuff erosion. CONCLUSIONS: EPA for radiation-associated urethral stenosis effectively provides unobstructed instrumentation-free voiding. However, increasing stenosis length and age are independently associated with surgical failure. Patients should be counseled that further surgery for incontinence may be necessary.


Assuntos
Anastomose Cirúrgica , Lesões por Radiação/cirurgia , Estreitamento Uretral/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/radioterapia , Recidiva , Estudos Retrospectivos , Estreitamento Uretral/etiologia , Esfíncter Urinário Artificial/estatística & dados numéricos
17.
Phys Rev Lett ; 127(26): 261803, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35029490

RESUMO

We report the results from a haloscope search for axion dark matter in the 3.3-4.2 µeV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the Kim-Shifman-Vainshtein-Zakharov model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.

18.
Rev Sci Instrum ; 92(12): 124502, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34972408

RESUMO

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66-3.1 µeV mass range with Dine-Fischler-Srednicki-Zhitnisky sensitivity [Du et al., Phys. Rev. Lett. 120, 151301 (2018) and Braine et al., Phys. Rev. Lett. 124, 101303 (2020)]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

19.
Abdom Radiol (NY) ; 46(2): 506-516, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32761405

RESUMO

PURPOSE: Stool burden on abdominal radiographs is not reflective of constipation, perhaps because of variable fecal shadowing or limited inter-rater agreement. These limitations are hypothetically mitigated by computed tomography (CT). This research aimed (i) to evaluate whether bowel movement frequency, stool form, or a diagnosis of functional constipation correlate or associate with stool burden identified on CT, and (ii) to investigate whether physicians use CT in their assessment of a patients' bowel function. METHODS: Patients attending for non-emergent abdominal CT imaging were invited to participate by completing a bowel questionnaire. Stool burden identified on imaging was determined and inter-rater reliability was evaluated in a subgroup of patients (n = 20). Descriptive and comparative analyses were performed. An online questionnaire evaluated the use of abdominal imaging in assessing patients' bowel function in a cross-section of ordering physicians. RESULTS: The patient response rate was 19% (96/516). No clinically useful associations between fecal burden and stool form, bowel motion frequency, gastrointestinal symptoms or a diagnosis of constipation was identified. The physician response rate was 35% (33/94). Opportunistic use of data was more common than deliberate use. However, an abdominal radiograph or CT scan had been requested by 42% and 18% of physicians respectively to assess patient's chronic bowel habit. Approximately 30% of physicians believed evidence supported this practice. CONCLUSIONS: Physicians may use abdominal CT in their assessment of patients' chronic bowel habits. However, objective assessment does not support this practice. Colonic stool burden does not correlate with patient-reported symptoms or a criteria-based diagnosis of constipation.


Assuntos
Defecação , Tomografia Computadorizada por Raios X , Estudos Transversais , Hábitos , Humanos , Reprodutibilidade dos Testes
20.
Med Phys ; 48(1): 397-413, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33151543

RESUMO

PURPOSE: Gantry-free radiation therapy systems utilizing patient rotation would be simpler and more cost effective than the conventional gantry-based systems. Such a system could enable the expansion of radiation therapy to meet global demand and reduce capital costs. Recent advances in adaptive radiation therapy could potentially be applied to correct for gravitational deformation during horizontal patient rotation. This study aims to quantify the pelvic organ motion and the dosimetric implications of horizontal rotation for prostate intensity-modulated radiation therapy (IMRT) treatments. METHODS: Eight human participants who previously received prostate radiation therapy were imaged in a clinical magnetic resonance imaging (MRI) scanner using a bespoke patient rotation system (PRS). The patients were imaged every 45 degrees during a full roll rotation (0-360 degrees). Whole pelvic bone, prostate, rectum, and bladder motion were compared to the supine position using dice similarity coefficient (DSC) and mean absolute surface distance (MASD). Prostate centroid motion was compared in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) direction prior to and following pelvic bone-guided rigid registration. Seven-field prostate IMRT treatment plans were generated for each patient rotation angles under three adaption scenarios: No plan adaption, rigid planning target volume (PTV)-guided alignment to the prostate, and plan re-optimization. Prostate, rectum, and bladder doses were compared for each adaption scenario. RESULTS: Pelvic bone motion within the PRS of up to 53 mm relative to the supine position was observed for some participants. Internal organ motion was greatest at the 180-degree PRS couch angle (prone), with prostate centroid motion range < 2 mm LR, 0 mm to 14 mm SI, and -11 mm to 4 mm AP. Rotation with no adaption of the treatment plan resulted in an underdose to the PTV -- in some instances up to 75% (D95%: 78 ± 0.3 Gy at supine to 20 ± 15.0 Gy at the 225-degree PRS couch angle). Bladder dose was reduced during the rotation by up to 98% (V60 Gy: 15.0 ± 9.4% supine to 0.3 ± 0.5% at the 225-degree PRS couch angle). In some instances, the rectum dose increased during rotation (V60Gy: 20.0 ± 4.5% supine to 25.0 ± 15.0% at the 135-degree PRS couch angle). Rigid PTV-guided alignment resulted in PTV coverage which, though statistically lower (P < 0.05 for all D95% values), was within 1 Gy of the supine plans. Plan re-optimization resulted in a statistically equivalent PTV coverage compared to the supine plans (P > 0.05 for all D95% metrics and all within ±0.4 Gy). For both rigid PTV-guided alignment and plan re-optimization, rectum dose volume metrics were reduced compared to the supine position between the 90- and 225-degree PRS couch angles (P < 0.05). Bladder dose volume metrics were not impacted by rotation. CONCLUSION: Pelvic bone and internal organ motion are present during patient rotation. Rigid PTV-guided alignment to the prostate will be a requirement if prostate IMRT is to be safely delivered using patient rotation. Plan re-optimization for each PRS couch angle to account for anatomical deformations further improves the PTV coverage.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Movimentos dos Órgãos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...