Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1232: 340442, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36257733

RESUMO

In the present work, we report an innovative approach for immunosensors construction. The experimental strategy is based on the anchoring of biological material at screen-printed carbon electrode (SPE) modified with electrodeposited Graphene Quantum Dots (GQD) and polyhydroxybutyric acid (PHB). It was used as functional substract basis for the recognition site receptor-binding domain (RBD) from coronavirus spike protein (SARS-CoV-2), for the detection of Anti-S antibodies (AbS). SEM images and EDS spectra suggest an interaction of the protein with GQD-PHB sites at the electrode surface. Differential pulse voltametric (DPV) measurements were performed before and after incubation, in presence of the target, shown a decrease in voltametric signal of an electrochemical probe ([Fe(CN)6]3/4-). Using the optimal experimental conditions, analytical curves were performed in PBS and human serum spiked with AbS showing a slight matrix effect and a relationship between voltametric signal and AbS concentration in the range of 100 ng mL-1 and 10 µg mL-1. The selectivity of the proposed sensor was tested against yellow fever antibodies (YF) and the selective layer on the electrode surface did not interact with these unspecific antibodies. Eight samples of blood serum were analyzed and 87.5% of these total investigated provided adequate results. In addition, the present approach showed better results against traditional EDC/NHS reaction with enhancements in time and the possibility to develop an immunosensor in a single drop, since the proteins can be anchored prior to the electrode modification step.


Assuntos
Técnicas Biossensoriais , COVID-19 , Grafite , Pontos Quânticos , Humanos , Grafite/química , Pontos Quânticos/química , SARS-CoV-2 , Técnicas Eletroquímicas/métodos , Glicoproteína da Espícula de Coronavírus , Limite de Detecção , Imunoensaio , Eletrodos , Carbono/química , Anticorpos
2.
Anal Chim Acta ; 1147: 30-37, 2021 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-33485583

RESUMO

Simple, low-cost, and sensitive new platforms for electrochemical immunosensors for virus detection have been attracted attention due to the recent pandemic caused by a new type of coronavirus (SARS-CoV-2). In the present work, we report for the first time the construction of an immunosensor using a commercial 3D conductive filament of carbon black and polylactic acid (PLA) to detect Hantavirus Araucaria nucleoprotein (Np) as a proof-of-concept. The recognition biomolecule was anchored directly at the filament surface by using N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride and N-Hydroxysuccinimide (EDC/NHS). Conductive and non-conductive composites of PLA were characterized using thermal gravimetric analysis (TGA), revealing around 30% w/w of carbon in the filament. Morphological features of composites were obtained from SEM and TEM measurements. FTIR measurement revealed that crosslinking agents were covalently bonded at the filament surface. Electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used for the evaluation of each step involved in the construction of the proposed immunosensor. The results showed the potentiality of the device for the quantitative detection of Hantavirus Araucaria nucleoprotein (Np) from 30 µg mL-1 to 240 µg mL-1 with a limit of detection of 22 µg mL-1. Also, the proposed immunosensor was applied with success for virus detection in 100x diluted human serum samples. Therefore, the PLA conductive filament with carbon black is a simple and excellent platform for immunosensing, which offers naturally carboxylic groups able to anchor covalently biomolecules.


Assuntos
Anticorpos Antivirais/imunologia , Imunoensaio/métodos , Proteínas do Nucleocapsídeo/imunologia , Impressão Tridimensional , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , COVID-19/diagnóstico , COVID-19/virologia , Espectroscopia Dielétrica , Eletrodos , Orthohantavírus/isolamento & purificação , Orthohantavírus/metabolismo , Infecções por Hantavirus/diagnóstico , Infecções por Hantavirus/virologia , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Proteínas do Nucleocapsídeo/sangue , SARS-CoV-2/isolamento & purificação , Fuligem/química