Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 34(6): 900-9, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17216166

RESUMO

PURPOSE: The segmentation algorithm ESM based on an elastic surface model was validated for the assessment of left ventricular volumes and ejection fraction from ECG-gated myocardial perfusion SPECT. Additionally, it was compared with the commercially available quantification packages 4D-MSPECT and QGS. Cardiac MRI was used as the reference method. METHODS: SPECT and MRI were performed on 70 consecutive patients with suspected or proven coronary artery disease. End-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were derived from SPECT studies by using the segmentation algorithms ESM, 4D-MSPECT and QGS and from cardiac MRI. RESULTS: ESM-derived values for EDV and ESV correlated well with those from cardiac MRI (correlation coefficients R=0.90 and R=0.95, respectively), as did the measurements for LVEF (R=0.86). Both EDV and ESV were slightly overestimated for larger ventricles but not for smaller ventricles; LVEF was slightly overestimated irrespective of ventricle size. The above correlation coefficients are comparable to those for the 4D-MSPECT and QGS segmentation algorithms. However, results obtained with the three segmentation algorithms are not interchangeable. CONCLUSION: The ESM algorithm can be used to assess EDV, ESV and LVEF from gated perfusion SPECT images. Overall, the performance was similar to that of 4D-MSPECT and QGS when compared with cardiac MRI. Results obtained with the three tested segmentation methods are not interchangeable, so that the same algorithm should be used for follow-up studies and control subjects.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Elasticidade , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Ventrículos do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
3.
Eur J Intern Med ; 16(6): 429-31, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16198903

RESUMO

BACKGROUND: Fractional flow reserve (FFR) is a valid surrogate for hemodynamic significance in stenotic native coronary arteries. The aim of this study was to examine the value of FFR compared to stress perfusion myocardial scintigraphy (SPMS) in patients with coronary stent restenosis. METHODS: We studied 42 patients, aged 62+/-10 years, with stent restenosis 5.3+/-1.6 months after coronary stent implantation. All patients had a single coronary lesion of intermediate severity (diameter stenosis 40-70%). FFR measurement, SPMS, and quantitative angiography of the stent stenosis were performed in all patients. RESULTS: The mean percentage in stent diameter stenosis was 53+/-9%. FFR was 0.77+/-0.15. In 20 patients FFR was below 0.75. Nineteen patients had reversible perfusion defects in SPMS. FFR showed good diagnostic accuracy for the detection of reversible perfusion defects in SPMS (AUROC 0.86, 95% CI 0.74-0.98). The percentage of agreement of SPMS and FFR was 88%, with the best cutoff value of 0.75 for FFR. CONCLUSIONS: A FFR value of 0.75 is not only valid for diagnosing significant native coronary stenosis, but also for stent restenosis. Thus, FFR measurement should be taken into account when making decisions regarding patients with stent restenosis.

4.
J Nucl Med ; 46(8): 1256-63, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16085580

RESUMO

UNLABELLED: The goal of this study was to validate the accuracy of the Emory Cardiac Tool Box (ECTB) in assessing left ventricular end-diastolic or end-systolic volume (EDV, ESV) and ejection fraction (LVEF) from gated (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SPECT using cardiac MRI (cMRI) as a reference. Furthermore, software-specific characteristics of ECTB were analyzed in comparison with 4D-MSPECT and Quantitative Gated SPECT (QGS) results (all relative to cMRI). METHODS: Seventy patients with suspected or known coronary artery disease were examined using gated (99m)Tc-MIBI SPECT (8 gates/cardiac cycle) 60 min after tracer injection at rest. EDV, ESV, and LVEF were calculated from gated (99m)Tc-MIBI SPECT using ECTB, 4D-MSPECT, and QGS. Directly before or after gated SPECT, cMRI (20 gates/cardiac cycle) was performed as a reference. EDV, ESV, and LVEF were calculated using Simpson's rule. RESULTS: Correlation between results of gated (99m)Tc-MIBI SPECT and cMRI was high for EDV (R = 0.90 [ECTB], R = 0.88 [4D-MSPECT], R = 0.92 [QGS]), ESV (R = 0.94 [ECTB], R = 0.96 [4D-MSPECT], R = 0.96 [QGS]), and LVEF (R = 0.85 [ECTB], R = 0.87 [4D-MSPECT], R = 0.89 [QGS]). EDV (ECTB) did not differ significantly from cMRI, whereas 4D-MSPECT and QGS underestimated EDV significantly compared with cMRI (mean +/- SD: 131 +/- 43 mL [ECTB], 127 +/- 42 mL [4D-MSPECT], 120 +/- 38 mL [QGS], 137 +/- 36 mL [cMRI]). For ESV, only ECTB yielded values that were significantly lower than cMRI. For LVEF, ECTB and 4D-MSPECT values did not differ significantly from cMRI, whereas QGS values were significantly lower than cMRI (mean +/- SD: 62.7% +/- 13.7% [ECTB], 59.0% +/- 12.7% [4DM-SPECT], 53.2% +/- 11.5% [QGS], 60.6% +/- 13.9% [cMRI]). CONCLUSION: EDV, ESV, and LVEF as determined by ECTB, 4D-MSPECT, and QGS from gated (99m)Tc-MIBI SPECT agree over a wide range of clinically relevant values with cMRI. Nevertheless, any algorithm-inherent over- or underestimation of volumes and LVEF should be accounted for and an interchangeable use of different software packages should be avoided.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem do Acúmulo Cardíaco de Comporta/métodos , Imageamento Tridimensional/métodos , Software , Volume Sistólico , Tecnécio Tc 99m Sestamibi , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/etiologia
5.
J Am Soc Echocardiogr ; 18(4): 330-5, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15846160

RESUMO

Analysis of diastolic function for assessment of myocardial viability has not been evaluated. Strain rate (SR) analysis allows quantitative segmental analysis of myocardial function and has been used during dobutamine stimulation for assessment of systolic functional reserve. In 37 patients with ischemic left ventricular dysfunction diastolic function was evaluated at rest and during low-dose dobutamine stimulation (10 mug/kg/min) using SR imaging and related to F18-fluorodeoxyglucose positron emission tomography. Analysis of peak early (E waves) and late (A waves) diastolic myocardial SR was performed using apical views. In all, 317 segments had normal function at rest by 2-dimensional echocardiography. A total of 192 segments with dyssynergy at rest were classified by positron emission tomography as viable in 94 cases and nonviable in 98 cases. Dys-synergic segments had lower E and A waves SR compared with normal contracting segments. There were no significant differences in peak E and A waves SR at rest between dys-synergic viable and nonviable segments. With dobutamine stimulation peak E waves SR increased significantly for viable segments (0.89 +/- 0.51-1.06 +/- 0.51 L/s, P < .01) whereas it was unchanged for nonviable segments (0.77 +/- 0.49-0.78 +/- 0.48 L/s, P = .835). Peak A waves SR increased for viable (0.71 +/- 0.55-1.00 +/- 0.56 L/s, P < .01) and nonviable (0.57 +/- 0.47-0.71 +/- 0.58 L/s, P = .023) segments. However, during dobutamine stimulation peak A waves SR was larger ( P < .001) for viable than for nonviable segments. In conclusion, normal contracting segments at rest have higher E and A waves SR compared with dys-synergic segments. Dys-synergic viable myocardial segments demonstrate an increase in E and A waves SR with dobutamine stimulation whereas nonviable segments are less responsive to dobutamine.


Assuntos
Diástole/fisiologia , Contração Miocárdica/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Análise de Variância , Cardiotônicos/administração & dosagem , Distribuição de Qui-Quadrado , Angiografia Coronária , Dobutamina/administração & dosagem , Ecocardiografia , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão
6.
J Nucl Med ; 45(12): 2016-20, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15585475

RESUMO

UNLABELLED: Gated myocardial perfusion SPECT allows assessment of left ventricular end-diastolic volume (EDV), left ventricular end-systolic volume (ESV), left ventricular stroke volume (SV), and left ventricular ejection fraction (LVEF). Acquiring images with the patient both prone and supine is an approved method of identifying and reducing artifacts. Yet prone positioning alters physiologic conditions. This study investigated how prone versus supine patient positioning during gated SPECT affects EDV, ESV, SV, LVEF, and heart rate. METHODS: Forty-eight patients scheduled for routine myocardial perfusion imaging were examined with gated (99m)Tc-sestamibi SPECT (at rest) while positioned prone and supine (consecutively, in random order). All parameters for both acquisitions were calculated using the commercially available QGS algorithm. RESULTS: Whereas EDV and SV were significantly lower (P < 0.0004) for prone acquisitions (EDV, 110.5 +/- 39.1 mL; SV, 55.9 +/- 13.3 mL) than for supine acquisitions (EDV, 116.9 +/- 36.2 mL; SV, 61.0 +/- 14.5 mL), ESV and LVEF did not differ significantly. Heart rate was significantly higher (P < 0.0001) during prone acquisitions (69.1 +/- 10.5 min(-1)) than during supine acquisitions (66.5 +/- 10.0 min(-1)). CONCLUSION: The observed position-dependent effect on EDV, SV, and heart rate might be explained by decreased arterial filling and increased sympathetic nerve activity. Hence, supine reference data should not be used to classify the results of prone acquisitions.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Decúbito Ventral , Volume Sistólico/fisiologia , Decúbito Dorsal
7.
Nucl Med Commun ; 25(10): 987-97, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15381866

RESUMO

BACKGROUND: Two of the most widely accepted approaches to map eloquent cortical areas preoperatively are positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). As yet, no study has compared these two modalities within the same frame of reference in tumour patients. AIM: We employed [15O]-H2O-PET and fMRI in patients undergoing presurgical evaluation and compared the results with those obtained by direct electrical cortical stimulation (DECS). METHODS: Twenty-five patients with tumours of different aetiology near the central region were investigated. fMRI and PET were processed using the same methods, i.e. statistical parametric mapping (SPM) without anatomical normalization, and transformed into the same frame of reference. RESULTS: fMRI activity was found in more cranial and lateral sections, i.e. closer to the brain surface, in comparison with PET, which demonstrated parenchymal activation. The mean localization difference between fMRI and PET was 8.1 +/- 4.6 mm (range, 2-18 mm). fMRI and [15O]-H2O-PET could reliably identify the central sulcus, as demonstrated by DECS. CONCLUSIONS: fMRI and [15O]-H2O-PET demonstrate comparable results and are sensitive and reliable tools to map the central region, especially in cases of infiltrating brain tumours. However, fMRI is more prone to artefacts, such as the visualization of draining veins, which may explain the more cranial and lateral activation visualized by fMRI, whereas PET depicts capillary perfusion changes and therefore shows activation closer to the parenchyma.


Assuntos
Mapeamento Encefálico/métodos , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/cirurgia , Imageamento por Ressonância Magnética/métodos , Córtex Motor/diagnóstico por imagem , Córtex Motor/fisiopatologia , Técnica de Subtração , Adulto , Idoso , Idoso de 80 Anos ou mais , Potencial Evocado Motor , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Assistência Perioperatória/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Água
8.
Eur J Nucl Med Mol Imaging ; 31 Suppl 1: S118-24, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15146295

RESUMO

Breast cancer continues to be one of the most common cancers in North America and Western Europe. Positron emission tomography with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG PET) represents a non-invasive functional imaging modality that is based on metabolic characteristics of malignant tumours. In breast cancer, FDG PET is more accurate than conventional methods for staging of distant metastases or local recurrences and enables early assessment of treatment response in patients undergoing primary chemotherapy. Recent data indicate a rationale for the use of FDG PET in cases of asymptomatically elevated tumour marker levels in the presence of uncertain results of conventional imaging. Despite the fact that PET cannot rule out microscopic disease, it does have particular value in providing, in a single examination, a reliable assessment of the true extent of the disease. This technique is complementary to morphological imaging for primary diagnosis, staging and re-staging. It may become the method of choice for the assessment of asymptomatic patients with elevated tumour marker levels. This method, however, cannot replace invasive procedures if microscopic disease is of clinical relevance.


Assuntos
Biomarcadores Tumorais/sangue , Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18 , Recidiva Local de Neoplasia/sangue , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Mama/patologia , Ensaios Clínicos como Assunto , Feminino , Humanos , Metástase Linfática , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias/métodos , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/normas , Prognóstico , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade
9.
Eur J Nucl Med Mol Imaging ; 31(4): 482-90, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-14722679

RESUMO

The main aim of this study was to validate the accuracy of 4D-MSPECT in the assessment of left ventricular (LV) end-diastolic/end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) from gated technetium-99m methoxyisobutylisonitrile single-photon emission tomography ((99m)Tc-MIBI SPET), using cardiac magnetic resonance imaging (cMRI) as the reference method. By further comparing 4D-MSPECT and QGS with cMRI, the software-specific characteristics were analysed to elucidate clinical applicability. Fifty-four patients with suspected or proven coronary artery disease (CAD) were examined with gated (99m)Tc-MIBI SPET (8 gates/cardiac cycle) about 60 min after tracer injection at rest. LV EDV, ESV and LVEF were calculated from gated (99m)Tc-MIBI SPET using 4D-MSPECT and QGS. On the same day, cMRI (20 gates/cardiac cycle) was performed, with LV EDV, ESV and LVEF calculated using Simpson's rule. Both algorithms worked with all data sets. Correlation between the results of gated (99m)Tc-MIBI SPET and cMRI was high for EDV [ R=0.89 (4D-MSPECT), R=0.92 (QGS)], ESV [ R=0.96 (4D-MSPECT), R=0.96 (QGS)] and LVEF [ R=0.89 (4D-MSPECT), R=0.90 (QGS)]. In contrast to ESV, EDV was significantly underestimated by 4D-MSPECT and QGS compared to cMRI [130+/-45 ml (4D-MSPECT), 122+/-41 ml (QGS), 139+/-36 ml (cMRI)]. For LVEF, 4D-MSPECT and cMRI revealed no significant differences, whereas QGS yielded significantly lower values than cMRI [57.5%+/-13.7% (4D-MSPECT), 52.2%+/-12.4% (QGS), 60.0%+/-15.8% (cMRI)]. In conclusion, agreement between gated (99m)Tc-MIBI SPET and cMRI is good across a wide range of clinically relevant LV volume and LVEF values assessed by 4D-MSPECT and QGS. However, algorithm-varying underestimation of LVEF should be accounted for in the clinical context and limits interchangeable use of software.


Assuntos
Volume Cardíaco , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem do Acúmulo Cardíaco de Comporta/métodos , Interpretação de Imagem Assistida por Computador/métodos , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Doença da Artéria Coronariana/complicações , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Validação de Programas de Computador , Tecnécio Tc 99m Sestamibi , Disfunção Ventricular Esquerda/etiologia
10.
J Nucl Med ; 45(1): 74-9, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14734676

RESUMO

UNLABELLED: The aim of this study was to validate Quantitative Gated SPECT (QGS) and 4D-MSPECT for assessing left ventricular end-diastolic and systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF) from gated (18)F-FDG PET. METHODS: Forty-four patients with severe coronary artery disease were examined with gated (18)F-FDG PET (8 gates per cardiac cycle). EDV, ESV, and LVEF were calculated from gated (18)F-FDG PET using QGS and 4D-MSPECT. Within 2 d (median), cardiovascular cine MRI (cMRI) (20 gates per cardiac cycle) was done as a reference. RESULTS: QGS failed to accurately detect myocardial borders in 1 patient; 4D-MSPECT, in 2 patients. For the remaining 42 patients, correlation between the results of gated (18)F-FDG PET and cMRI was high for EDV (R = 0.94 for QGS and 0.94 for 4D-MSPECT), ESV (R = 0.95 for QGS and 0.95 for 4D-MSPECT), and LVEF (R = 0.94 for QGS and 0.90 for 4D-MSPECT). QGS significantly (P < 0.0001) underestimated LVEF, whereas no other parameter differed significantly between gated (18)F-FDG PET and cMRI for either algorithm. CONCLUSION: Despite small systematic differences that, among other aspects, limit interchangeability, agreement between gated (18)F-FDG PET and cMRI is good across a wide range of clinically relevant volumes and LVEF values assessed by QGS and 4D-MSPECT.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Fluordesoxiglucose F18 , Imagem do Acúmulo Cardíaco de Comporta/métodos , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Tomografia Computadorizada de Emissão/métodos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia
11.
Anticancer Res ; 23(2C): 1859-67, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12820470

RESUMO

BACKGROUND: The aim of this study was to investigate the diagnostic value of FDG PET in the follow-up for breast cancer in disease-free patients and patients suspected of having recurrent or metastatic disease. As a single imaging tool, PET can be compared with the conventional diagnostic means used for different examination sites. PATIENTS AND METHODS: A total of 73 PET studies were carried out on 57 patients who had been diagnosed as having breast cancer. Sixteen patients had two PET scans. Thirty-eight scans (52.%) were performed in a follow-up setting. Thirty-five PET scans were performed in patients suspected of having recurrent disease or elevated tumor marker. Depending on the region of suspicion, conventional imaging included computed tomography, magnetic resonance imaging, chest X-ray, ultrasound and X-ray. All the patients in our study were followed-up for a period of 12 months. RESULTS: PET correctly identified metastatic or recurrent disease in 25 out 27 cases of clinical suspicion. In patients examined because of elevated tumour marker CA 15-3, PET was able to detect recurrence or metastatic disease in six of the eight patients. The absence of disease was correctly diagnosed by PET in 35 out of 38 scans in 24 patients in the follow-up for breast cancer. The overall sensitivity and specificity for PET was 80.6% and 97.6%, respectively. On the basis of a yearly rate of disease progression of 5-8%, the mean positive predictive value was 74.5% and the mean negative predictive value 98.3%. CONCLUSION: PET has been shown to have impact on the staging and management of recurrent or metastatic breast cancer in cases of suspicion and in a follow-up setting. The current oncological situation can be clarified with a single basic imaging modality.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/secundário , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/secundário , Intervalo Livre de Doença , Feminino , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Seguimentos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Metástase Linfática , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão
12.
J Am Coll Cardiol ; 41(9): 1523-8, 2003 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-12742293

RESUMO

OBJECTIVES: We investigated whether cardiac resynchronization therapy (CRT) affects myocardial glucose metabolism and perfusion in dilated cardiomyopathy (DCM) and left bundle branch block (LBBB). BACKGROUND: Patients with DCM and LBBB present with asynchronous left ventricular (LV) activation, leading to reduced septal glucose metabolism. Cardiac resynchronization therapy recoordinates LV activation, but its effects on myocardial glucose metabolism and perfusion remain unknown. METHODS: In 15 patients (10 females; 61 +/- 13 years) with DCM and LBBB (QRS width 165 +/- 15 ms), gated (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography were performed before and after two weeks of CRT. Uptake of FDG and (99m)Tc-sestamibi was determined in four LV wall areas. Ejection fraction and volumes were calculated from gated PET. RESULTS: Baseline FDG uptake was heterogeneous (p < 0.0001), with lowest uptake in the septal region (56 +/- 12%) and highest uptake in the lateral region (89 +/- 6%). During CRT, septal and anterior increases (p < 0.01) and lateral decreases (p < 0.01) resulted in homogeneously distributed glucose metabolism. Baseline heterogeneity (p < 0.0001) in (99m)Tc-sestamibi uptake was modest (lowest septal 65 +/- 10%; maximum lateral 84 +/- 5%) and also reduced with CRT, although some heterogeneity (p < 0.05) remained. The septal-to-lateral ratio increased with CRT for FDG (0.62 +/- 0.12 to 0.91 +/- 0.26, p < 0.001) and (99m)Tc-sestamibi uptake (0.77 +/- 0.13 to 0.85 +/- 0.16, p < 0.01). The LV end-diastolic and end-systolic volumes decreased from 293 +/- 160 to 272 +/- 158 ml (p < 0.05) and from 244 +/- 164 to 220 +/- 160 ml (p < 0.01), respectively. Ejection fraction increased from 22 +/- 12% to 25 +/- 13% (p < 0.01). CONCLUSIONS: Glucose metabolism is reduced more than perfusion in the septal compared with LV lateral wall in patients with DCM and LBBB. Cardiac resynchronization therapy restores homogeneous myocardial glucose metabolism with less influence on perfusion.


Assuntos
Bloqueio de Ramo/metabolismo , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Cardiomiopatia Dilatada/metabolismo , Cardiomiopatia Dilatada/terapia , Circulação Coronária/fisiologia , Glucose/metabolismo , Miocárdio/metabolismo , Idoso , Bloqueio de Ramo/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico por imagem , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/metabolismo , Átrios do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/metabolismo , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão , Tomografia Computadorizada de Emissão de Fóton Único
13.
Eur J Nucl Med Mol Imaging ; 30(7): 951-60, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12748833

RESUMO

In patients scheduled for the resection of perisylvian brain tumours, knowledge of the cortical topography of language functions is crucial in order to avoid neurological deficits. We investigated the applicability of statistical parametric mapping (SPM) without stereotactic normalisation for individual preoperative language function brain mapping using positron emission tomography (PET). Seven right-handed adult patients with left-sided brain tumours (six frontal and one temporal) underwent 12 oxygen-15 labelled water PET scans during overt verb generation and rest. Individual activation maps were calculated for P<0.005 and P<0.001 without anatomical normalisation and overlaid onto the individuals' magnetic resonance images for preoperative planning. Activations corresponding to Broca's and Wernicke's areas were found in five and six cases, respectively, for P<0.005 and in three and six cases, respectively, for P<0.001. One patient with a glioma located in the classical Broca's area without aphasic symptoms presented an activation of the adjacent inferior frontal cortex and of a right-sided area homologous to Broca's area. Four additional patients with left frontal tumours also presented activations of the right-sided Broca's homologue; two of these showed aphasic symptoms and two only a weak or no activation of Broca's area. Other frequently observed activations included bilaterally the superior temporal gyri, prefrontal cortices, anterior insulae, motor areas and the cerebellum. The middle and inferior temporal gyri were activated predominantly on the left. An SPM group analysis ( P<0.05, corrected) in patients with left frontal tumours confirmed the activation pattern shown by the individual analyses. We conclude that SPM analyses without stereotactic normalisation offer a promising alternative for analysing individual preoperative language function brain mapping studies. The observed right frontal activations agree with proposed reorganisation processes, but they may also reflect an unspecific recruitment of the right-sided Broca's homologue in the effort to perform the task.


Assuntos
Mapeamento Encefálico/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Córtex Cerebral/diagnóstico por imagem , Idioma , Cuidados Pré-Operatórios/métodos , Tomografia Computadorizada de Emissão/métodos , Adulto , Neoplasias Encefálicas/fisiopatologia , Córtex Cerebral/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Fala
14.
Eur Radiol ; 13(4): 740-7, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12664112

RESUMO

The aims of the present study were (a) to evaluate mediastinal staging in patients with lung cancer with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) using a coincidence gamma camera (hybrid PET) in comparison with dedicated positron emission tomography (PET) and computed tomography (CT), and (b) to assess the feasibility to determine standardized uptake values (SUV) with hybrid PET. Forty patients were included in the study. Hybrid PET was performed without and with attenuation correction. Data were rebinned with single-slice (SSRB) or Fourier rebinning (FORE). The SUVs of primary tumors were calculated with hybrid PET and compared with SUVs determined by dedicated PET. Diagnostic accuracy for hybrid with or without attenuation correction was 80 or 74% compared with 82% for dedicated PET, and 63% for CT. Attenuation-corrected hybrid PET revealed a higher specificity than CT (83 vs 52%; p<0.05). The SUVs of primary tumors were similar to those of hybrid PET and dedicated PET with a mean relative difference of 20.8+/-16.4%. The FORE improved the agreement of SUVs with a mean relative difference of 13.8+/-9.9 vs 36.0+/-17.9% for SSRB ( p<0.001). Hybrid PET with attenuation correction is more specific than CT for mediastinal staging in patients with lung cancer ( p<0.05). It reveals similar results in comparison with dedicated PET. Calculation of SUVs with hybrid PET is feasible.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Tomografia Computadorizada de Emissão , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Carcinoma de Células Grandes/diagnóstico por imagem , Carcinoma de Células Grandes/patologia , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Estudos de Viabilidade , Câmaras gama , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Mediastino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão/métodos , Tomografia Computadorizada por Raios X
15.
J Nucl Cardiol ; 10(1): 34-45, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12569329

RESUMO

BACKGROUND: There is controversy about the role of decreased resting blood flow as the pathophysiologic correlate of hibernating myocardium. The aim of this study was an absolute quantification of volumetric myocardial blood flow (MBFvol) in dysfunctional myocardium with different viability conditions as defined by fluorine 18 deoxyglucose (FDG) positron emission tomography (PET) while taking into consideration the functional recovery after revascularization. The impact of MBFvol in the diagnosis of functional recovery was also investigated. METHODS AND RESULTS: Forty-two patients with severe coronary artery disease and dysfunctional myocardium underwent resting oxygen 15 water PET, as well as FDG PET and technetium 99m tetrofosmin single photon emission computed tomography, all attenuation-corrected. Relative FDG and Tc-99m tetrofosmin uptake (normalized to the segment with 100% Tc-99m tetrofosmin uptake), as well as MBFvol (myocardial blood flow multiplied by the water-perfusable tissue fraction to account for the flow to the entire segment volume), were determined in 18 myocardial segments per patient. Viability in dysfunctional segments (estimated by ventriculography) with reduced Tc-99m tetrofosmin uptake of 70% or lower was classified as viable (FDG >70%, mismatch) or nonviable (FDG < or =70%, match). Fifteen patients underwent revascularization and were followed up. Mismatch segments with improved function were classified as hibernating myocardium. Mean MBFvol in viable myocardium was slightly reduced (0.60 +/- 0.02 mL x min(-1) x mL(-1)) compared with that in normokinetic myocardium (0.64 +/- 0.01 mL x min(-1) x mL(-1)) (P = .036) and was significantly higher than in nonviable myocardium (0.36 +/- 0.01 mL x min(-1) x mL(-1)) (P < .001). Receiver operating characteristic analysis confirmed an FDG uptake greater than 70% as the optimal threshold to predict functional recovery (diagnostic accuracy [ACC], 76%). MBFvol in hibernating myocardium (0.62 +/- 0.04 mL x min(-1) x mL(-1)) was not significantly reduced compared with that in normokinetic myocardium (0.66 +/- 0.02 mL x min(-1) x mL(-1)) and was significantly higher than in persistently dysfunctional myocardium (0.51 +/- 0.04 mL x min(-1) x mL(-1)) (P < .05). The ACC of MBFvol greater than 0.40 mL x min(-1) x mL(-1) as the threshold to predict functional recovery was 61% but did not improve the accuracy of FDG PET by itself. CONCLUSIONS: In patients with severe coronary artery disease and dysfunctional myocardium, MBFvol as determined with O-15 water differs significantly between viable and nonviable myocardium as determined by FDG PET and is not significantly reduced in hibernating compared with normokinetic myocardium. Therefore chronically reduced resting blood flow appears unlikely to be the pathophysiologic correlate of the functional state of hibernation. However, MBFvol does not improve the ACC of FDG PET by itself.


Assuntos
Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Fluordesoxiglucose F18 , Miocárdio Atordoado/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Adulto , Idoso , Angiografia Coronária , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica , Miocárdio Atordoado/fisiopatologia , Miocárdio Atordoado/terapia , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único , Água
16.
Eur J Nucl Med Mol Imaging ; 30(4): 545-53, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12589480

RESUMO

The aim of this study was to validate the estimation of left ventricular end-diastolic and end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) as well as wall motion analysis from gated fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) in patients with severe coronary artery disease (CAD) using software originally designed for gated single-photon emission tomography (SPET). Thirty patients with severe CAD referred for myocardial viability diagnostics were investigated using a standard FDG PET protocol enhanced with gated acquisition (8 gates per cardiac cycle). EDV, ESV and LVEF were calculated using standard software designed for gated SPET (QGS). Wall motion was analysed using a visual four-point wall motion score on a 17-segment model. As a reference, all patients were also examined within a median of 3 days with cardiovascular cine magnetic resonance imaging (cMRI) (20 gates per cardiac cycle). Furthermore, all gated FDG PET data sets were reoriented in a second run with deliberately misaligned axes to test the quantification procedure for robustness. Correlation between the results of gated FDG PET and cMRI was very high for EDV and ESV ( R=0.96 and R=0.97) and for LVEF ( R=0.95). With gated FDG PET, there was a non-significant tendency to underestimate EDV (174+/-61 ml vs 179+/-59 ml, P=0.21) and to overestimate ESV (124+/-58 ml vs 122+/-60 ml, P=0.65), resulting in underestimated LVEF values (31.5%+/-9.4% vs 34.2%+/-12.4%, P<0.003). The results of reorientations 1 and 2 showed very high correlations (for all R>/=0.99). Segmental wall motion analysis revealed good agreement between gated FDG PET data and cMRI (kappa =0.62+/-0.03). In conclusion, despite small systematic differences which contributed mainly to the lower temporal resolution of gated FDG PET, agreement between gated FDG PET and cMRI was good across a wide range of volumes and LVEF values as well as for wall motion analysis. Therefore, gated FDG PET provides clinically relevant information on function and volumes, using the commercially available software package QGS.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Fluordesoxiglucose F18 , Imagem do Acúmulo Cardíaco de Comporta/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Emissão/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico
19.
J Nucl Med ; 44(1): 33-9, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12515874

RESUMO

UNLABELLED: Myocardial perfusion imaging with (99m)Tc-tetrofosmin is based on the assumption of a linear correlation between myocardial blood flow (MBF) and tracer uptake. However, it is known that (99m)Tc-tetrofosmin uptake is directly related to energy-dependent transport processes, such as Na(+)/H(+) ion channel activity, as well as cellular and mitochondrial membrane potentials. Therefore, cellular alterations that affect these energy-dependent transport processes ought to influence (99m)Tc-tetrofosmin uptake independently of blood flow. Because metabolism ((18)F-FDG)-perfusion ((99m)Tc-tetrofosmin) mismatch myocardium (MPMM) reflects impaired but viable myocardium showing cellular alterations, MPMM was chosen to quantify the blood flow-independent effect of cellular alterations on (99m)Tc-tetrofosmin uptake. Therefore, we compared microsphere-equivalent MBF (MBF_micr; (15)O-water PET) and (99m)Tc-tetrofosmin uptake in MPMM and in "normal" myocardium. METHODS: Forty-two patients with severe coronary artery disease, referred for myocardial viability diagnostics, were examined using (18)F-FDG PET and (99m)Tc-tetrofosmin perfusion SPECT. Relative (18)F-FDG and (99m)Tc-tetrofosmin uptake values were calculated using 18 segments per patient. Normal myocardium and MPMM myocardium were classified using a previously validated (99m)Tc-tetrofosmin SPECT/(18)F-FDG PET score. In addition, (15)O-water PET was performed to assess kinetic-modeled MBF (MBF_kin), the water-perfusable tissue fraction (PTF), and the resulting MBF_micr (MBF_kin x PTF), which is comparable to tracer uptake values. (99m)Tc-tetrofosmin uptake and MBF_micr values were calculated for all normal and MPMM segments and averaged within their respective classifications. RESULTS: Mean relative (99m)Tc-tetrofosmin uptake was 86% +/- 1% in normal myocardium and 56% +/- 1% in MPMM, showing a significant difference (P < 0.001), as was expected from the classification. Contrary to these findings, mean MBF_micr in MPMM myocardium was 0.60 +/- 0.03 mL x min(-1) x mL(-1), which did not significantly differ from normal myocardium (0.64 +/- 0.01 mL x min(-1) x mL(-1)). All values are given as mean +/- SEM. CONCLUSION: Differences between reduced (99m)Tc-tetrofosmin uptake and the unchanged MBF_micr in MPMM myocardium suggest that the pathophysiologic basis of MPMM is not a blood flow reduction but cellular alterations that affect uptake and retention of (99m)Tc-tetrofosmin independently of blood flow. Therefore, it seems that perfusion deficits in MPMM myocardium are greatly overestimated by (99m)Tc-tetrofosmin and that it tends to give false-positive findings.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Miocárdio/metabolismo , Compostos Organofosforados/farmacocinética , Compostos de Organotecnécio/farmacocinética , Isótopos de Oxigênio/farmacocinética , Tomografia Computadorizada de Emissão , Água/metabolismo , Adulto , Idoso , Doença da Artéria Coronariana/classificação , Circulação Coronária , Feminino , Fluordesoxiglucose F18/farmacocinética , Coração/diagnóstico por imagem , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
20.
J Nucl Cardiol ; 9(3): 304-11, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12032478

RESUMO

BACKGROUND: Rotational atherectomy (rotablation) frequently results in transient myocardial hypoperfusion due to peripheral vessel obstruction. This study compares the incidence, extent, and severity of perfusion defects induced by rotablation of de novo coronary lesions with rotablation of in-stent restenosis. METHODS AND RESULTS: Twenty-five patients undergoing rotablation for restenosed stents (group A) were studied by technetium 99m sestamibi single photon emission computed scintigraphy at rest before rotablation, during rotablation, and 2 days after the procedure. For semiquantitative analysis, perfusion in 24 left ventricular regions was expressed as percentage of maximal sestamibi uptake. The results were compared with those of 25 patients treated for de novo coronary lesions (group B). Transient perfusion defects were observed in 22 (88%) of 25 patients in group A and, similarly, in 23 (92%) of 25 in group B. Perfusion was significantly reduced during rotablation in 3.1 +/- 2.6 (mean +/- SD) regions in group A and in 3.3 +/- 2.5 regions in group B. Perfusion in the region with maximal reduction during rotablation in groups A and B was 77% +/- 13% and 76% +/- 15% at baseline. Technetium uptake decreased to 59% +/- 19% and 54% +/- 14% during rotablation (P <.001 vs baseline, P = not significant for A vs B) and returned to 76% +/- 16% and 76% +/- 15% after rotablation. Intravascular ultrasonography indicated no correlation between the volume of ablated plaque and the extent and severity of perfusion defects in in-stent restenosis. CONCLUSIONS: Incidence, extent, and severity of rotablation-related transient hypoperfusion are influenced by neither the type nor the quantity of ablated plaque material. Thus embolization of ablated plaque may be less important compared with other factors such as microcavitation or platelet aggregation.


Assuntos
Aterectomia Coronária , Doença das Coronárias/cirurgia , Stents , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Estudos de Casos e Controles , Circulação Coronária , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Compostos Radiofarmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA