1.
Environ Sci Pollut Res Int ; 23(7): 6300-11, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26614451

RESUMO

This study investigates the influence of three environmental indoor parameters (i.e., temperature, relative humidity, and air exchange rate) on the emission of 13 volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) during incense burning. Experiments have been carried out using an environmental test chamber. Statistical results from a classical two-level full factorial design highlight the predominant effect of ventilation on emission factors. The higher the ventilation, the higher the emission factor. Moreover, thanks to these results, an estimation of the concentration range for the compounds under study can be calculated and allows a quick look of indoor pollution induced by incense combustion. Carcinogenic substances (i.e., benzene, benzo(a)pyrene, and formaldehyde) produced from the incense combustion would be predicted in typical living indoors conditions to reach instantaneous concentration levels close to or higher than air quality exposure threshold values.


Assuntos
Poluentes Atmosféricos/análise , Eliminação de Resíduos/instrumentação , Compostos Orgânicos Voláteis/análise , Gerenciamento de Resíduos/instrumentação , Benzeno/análise , Formaldeído/análise , Umidade , Temperatura , Ventilação