Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Clin Pathol ; 153(1): 58-65, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31415692

RESUMO

OBJECTIVES: Vacuum-assisted biopsy (VAB) of the breast seems unsuitable for rapid processing due to large size. We tested microwave-based acceleration. METHODS: As a proof-of-principle study, 9-gauge VAB specimens were taken from eight mastectomy specimens. Forty-two biopsy specimens were processed. Quality of H&E was evaluated in 84 slides, and estrogen receptor (ER), progesterone receptor (PR), E-cadherin, and human epidermal growth factor receptor 2 (HER2) stains were evaluated in six slides. Preoperative biopsy specimens were used as a control. RESULTS: Diagnostic quality of H&E slides was good in 87%, reasonable in 12%, and low in 1%. Quality of E-cadherin was good in 75% and reasonable in 25%. Quality of ER was good in 83% and reasonable in 17%. PR and both HER2 immunohistochemistry and fluorescence in situ hybridization were good in all slides. Quality of experimental slides was similar to control slides. CONCLUSIONS: Nine-gauge VAB specimens can be processed within 4 hours. Slides are suitable for all routine pathologic stains. This enables a same-day diagnosis.


Assuntos
Antígenos CD/metabolismo , Neoplasias da Mama/patologia , Caderinas/metabolismo , Receptor ErbB-2/metabolismo , Biópsia por Agulha , Mama/metabolismo , Mama/patologia , Neoplasias da Mama/metabolismo , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imuno-Histoquímica , Hibridização in Situ Fluorescente , Mastectomia , Receptores de Estrogênio/análise , Receptores de Progesterona/análise , Vácuo
2.
Histopathology ; 73(1): 81-89, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29495112

RESUMO

AIMS: To establish whether core needle biopsy (CNB) specimens processed with an accelerated processing method with short fixation time can be used to determine accurately the human epidermal growth factor receptor 2 (HER2) status of breast cancer. METHODS AND RESULTS: A consecutive case-series from two high-volume breast clinics was created. We compared routine HER2 immunohistochemistry (IHC) assessment between accelerated processing CNB specimens and routinely processed postoperative excision specimens. Additional amplification-based testing was performed in cases with equivocal results. The formalin fixation time was less than 2 h and between 6 and 72 h, respectively. Fluorescence in-situ hybridisation and multiplex ligation-dependent probe amplification were used for amplification testing. One hundred and forty-four cases were included, 15 of which were HER2-positive on the routinely processed excision specimens. On the CNB specimens, 44 were equivocal on IHC and required an amplification-based test. Correlation between the CNB specimens and the corresponding excision specimens was high for final HER2 status, with an accuracy of 97% and a kappa of 0.85. CONCLUSIONS: HER2 status can be determined reliably on CNB specimens with accelerated processing time using standard clinical testing methods. Using this accelerated technology the minimum 6 h of formalin fixation, which current guidelines consider necessary, can be decreased safely. This allows for a complete and expedited histology-based diagnosis of breast lesions in the setting of a one-stop-shop, same-day breast clinic.


Assuntos
Neoplasias da Mama/diagnóstico , Receptor ErbB-2/análise , Fixação de Tecidos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Biópsia com Agulha de Grande Calibre , Feminino , Humanos , Pessoa de Meia-Idade
3.
Histopathology ; 66(3): 380-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25234295

RESUMO

AIMS: Immunohistochemical assessment of Ki67 expression in core-needle biopsies (CNBs) is increasingly playing a role in therapeutic decision-making for breast cancer patients. Within the framework of same-day diagnosis of breast lesions, fixation times are markedly decreased. We therefore attempted to validate Ki67 analysis in briefly fixed breast cancer CNBs. METHODS AND RESULTS: CNBs of 136 consecutive patients with invasive breast cancer diagnosed through the same-day diagnosis programme of both the University Medical Centre Utrecht (UMCU) and the Radboud University Medical Centre (RUMC) were included. CNBs were fixed in formaldehyde for approximately 45 min at the UMCU and for between 60 and 90 min at the RUMC. Immunohistochemistry for Ki67 expression was compared between the briefly fixed CNBs and conventionally fixed resection specimens of the same tumour. The overall agreement between CNBs and resections was 122 of 142 (85.9%) (κ = 0.71; 95% CI 0.60-0.83). Positive and negative predictive values were 79.7% (95% CI 67-88%) and 91.0% (95% CI 82-96%), respectively. CONCLUSIONS: Overall agreement for Ki67 expression was good between briefly fixed CNBs and conventionally fixed resection specimens, and within the range of studies comparing conventionally fixed CNBs and resections.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/diagnóstico , Carcinoma/diagnóstico , Antígeno Ki-67/análise , Fixação de Tecidos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia com Agulha de Grande Calibre , Feminino , Humanos , Imuno-Histoquímica , Pessoa de Meia-Idade
4.
Breast Cancer Res Treat ; 137(2): 609-16, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23239152

RESUMO

Many attempts have been made to combine the high diagnostic accuracy and conclusive rate of core needle biopsy (CNB) with the speed of fine needle aspiration cytology in evaluation of solid breast lesions. Multiple hybrid techniques have been developed to achieve this. We describe a cohort of patients for whom we used a relatively new, accelerated method of CNB processing, allowing for a definitive diagnosis the same day. All patients visiting the Radboud University Nijmegen Medical Centre breast clinic during a 4-year period were reviewed to identify all CNBs in this period performed in a same-day diagnosis track. CNB result was compared to post-operative pathology reports when available, and to follow-up when patients were not surgically treated. 1,060 patients underwent CNB of 1,383 lesions, 898 of which in a same-day diagnosis track with a sensitivity of 96.9 % and a specificity of 99.4 %. The inconclusive rate was 9.2 %. For a same-day diagnosis for solid breast lesions, we could give a conclusive diagnosis with accelerated CNB processing in 65 % of our patients requiring CNB. This technique can be used reliably in a same-day diagnosis breast clinic with a very high sensitivity, specificity, and conclusive rate.


Assuntos
Biópsia com Agulha de Grande Calibre , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Seguimentos , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores de Tempo , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA